Records from 2016 to 2025. Most recent: inspection, 28 August 2025.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 August 2025
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high: “EMERGENCY EXIT, KEEP CLEAR”... Aft Engine room emergency escape scuttle not marked from above. 46 CFR 185.606
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2025
Resolved 11 September 2025
Resolution: Operator emailed photos of satisfactory correction. Photos uploaded to documents.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 28 August 2025
Resolved
A fire hose with a nozzle must be attached to each fire hydrant at all times. Forward fire hose not connected to hydrant when stowed in enclosure. 46 CFR 181.320(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2025
Resolved 29 August 2025
Resolution: Operator sent photos of modified fire station allowing connection to hydrant while stowed. Photos added to documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 August 2025
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Letters and numbers must be at least 2 inches high. Symbols must be at least 4 inches square. Life jacket quantities are not marked. 46 CFR 185.604(b)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2025
Resolved 11 September 2025
Resolution: Operator emailed photos of satisfactory correction. Photos uploaded to documents.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 28 August 2025
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Plastic waste receptacles were located in wheelhouse and on the main deck. 46 CFR 177.405(f)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2025
Resolved 29 August 2025
Resolution: Operator sent photos of non combustible waste receptacles onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 August 2025
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. The vessel name is not marked on the life float paddles. 46 CFR 185.604(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2025
Resolved 11 September 2025
Resolution: Operator emailed photos of satisfactory correction. Photos uploaded to documents.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 2 October 2024
Resolved
Survival craft requirements are provided in Table 180.200(c): Lakes, Bays, & Sounds (b) nonwood - 50% LF. 12 person life float in unserviceable and requires painting. Maximum passengers limited to 85. Repaint life life float.
46 CFR 180.200(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 November 2024
Resolution: Received photographs of new liferaft installed on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 October 2024
Resolved
The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. All 3 batteries for the life float light are expired and/or incorrect. Replace batteries.
46 CFR 180.175(f)(4)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2024
Resolution: Received photograph of correct battery installations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 October 2024
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Lifejackets onboard only have "BROWNLEE" marked. Mark lifejackets with full name of vessel.
46 CFR 185.604(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2024
Resolution: Received photograph of lifejackets marked with vessel's full name.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 2 October 2024
Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight: A hatch on a vessel that operates only on protected waters. Engine room stbd hatch is leaking from a hose test. Replace gasket material and clean sealing face.
46 CFR 179.360(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2024
Resolution: Received satisfactory evidence that hatch seals have been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Wiring under bridge console was soaked in hydraulic fluid from previous steering fluid reservoir. Wipe and clean off hydraulic fluid.
46 CFR 176.830
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 October 2024
Resolution: Received photograph of underside console cleaned and free of hydraulic fluid.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 August 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to prevent electrical ignition of flammable vapors. Found exposed conductor on wire connected to aft engine room battery. Repair wire insulation to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2023
Resolved 29 September 2023
Resolution: Vessel repiared wire insulation to the satisfaction of the marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 August 2023
Resolved
No more than 19 liters (five gallons) of flammable liquids may be stowed in any machinery space. The flammable liquids must be in containers of 3.8 (one gallon) or less. Found multiple containers of oil in engine room exceeding five gallons. Reduce amount of flammable liquids in the engine room to five or less gallons.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2023
Resolved 3 October 2023
Resolution: Vessel removed access oil to the satisfaction of the marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 August 2023
Resolved
Spanner wrenches must be provided where a 1.5 inch diameter firehose is required. Aft fire station missing spanner wrench. Provide a spanner wrench to the aft fire station to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2023
Resolved 3 October 2023
Resolution: Vessel added spanner wrench to fire station to the satisfaction of the marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Steering gear system on the bridge was leaking hydraulic fluid through the deck and into the upper accommodation space. Clean remainder of hydraulic fluid that had leaked to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2023
Resolved 15 October 2023
Resolution: Vessel cleaned and fixed source of leak.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 28 August 2023
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Multi-cable transit through from the lower accommodation space to the engine room has been installed incorrectly and is not watertight. Repair to the satisfaction of the attending marine inspector.
Prior to credit Dry Dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 October 2024
Resolution: Attending MI verified cable transit correctly installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 September 2022
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. The fixed carbon dioxide fire fighting system has not been serviced annually in accordance to the manufacturer's instruction manual & CG requirements.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 23 September 2022
Resolved 23 September 2022
Resolution: Received Global Fire report on inspection of fixed system. Attached to documents.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 September 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. There were excessive conductors attached to the battery terminals in engine room and loose electrical wires throughout the vessel with exposed wiring.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2022
Resolved 26 September 2022
Resolution: Received satisfactory photos of electrical wiring installation/removal.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 September 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. The vessel was missing 01 life jacket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2022
Resolved 28 September 2022
Resolution: Received photograph from operator of newly installed lifejacket onboard.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 21 September 2022
Resolved
The public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. The public address system was not operational.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2022
Resolved 26 September 2022
Resolution: Recieved satisfactory video of the PA system in operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 August 2021
Resolved
Battery chargers must have an ammeter connected in the
charging circuit. Charger was missing ammeter.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2021
Resolution: Operator provided photo evidence of ammeter. Photo located in documents tab.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 August 2021
Resolved
A vessel must be provided with a main steering gear
that is of adequate strength and capable of steering the
vessel at all service speeds. Secure cotter pin.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 October 2021
Resolution: Operator provided photo of cotter pin secured. Photo in the documents tab.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 August 2021
Resolved
All cables or wires must serve some piece of equipment
or system onboard the vessel. If no longer in service,
the cables/wires must be properly removed from power
supply.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2021
Resolution: Dead end wires removed. See documents tab for photo.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 27 August 2021
Resolved
Spaces storing carbon dioxide must be marked
conspicuously as followed "CARBON DIOXIDE GAS CAN CAUSE
INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A
HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE
SUFFOCATION." Label door leading to fixed CO2 system.
46 CFR 185.612(g)1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2021
Resolution: Operator provided signage outside of CO2 space.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 August 2021
Resolved
Each life float must be fitted with a lifeline,
pendants, a painter and a light. Remove zip tie and reconnect light.
46 CFR 180.175(d)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2021
Resolution: Zip tie removed, and light attached.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 27 August 2021
Resolved
Each life float must be individually attached to the
painter by a line long enough that each life float can
float without contacting any other life floats. Insufficient arrangement. Corrected on the spot.
46 CFR 180.137(e)
Action required: 10 - Deficiency Rectified
Resolved 7 September 2021
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 27 August 2021
Resolved
At least one ring life buoy must be fitted with a
lifeline. Secure the lifeline around the ring buoy.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2021
Resolution: Operator provided photo of buoy fitted with a lifeline. See documents tab for photo.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 August 2021
Resolved
An adult life jacket must be provided for each person
carried on board a vessel. Purchase eight USCG approved life jackets to meet COI manning requirements.
46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2021
Resolution: Operator provided 8 USCG adult lifejackets.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 August 2021
Resolved
AIS provides vessel information, vessel's identity,
type, position, course, speed, navigational status and
other safety-related information. IMO number to be deleted, AIS ship type to be added and update antenna
distance.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2021
Resolution: Vessel updated AIS information.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 August 2021
Resolved
Each ring life buoy must be marked with Type I retro
reflective material. Bow ring life buoy missing retro
reflective tape.
46 CFR 185.604(i)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2021
Resolution: Submitted photos of ring buoy with retroreflective tape. Photo in the documents tab.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 August 2021
Resolved
Connections must be made to battery terminals with
permanent type connectors. Wing nuts on batteries outside of wheel house are not sufficient.
46 CFR 183.350(d)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2021
Resolution: Battery nuts replaced. See documents tab for photograph.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 August 2021
Resolved
All electrical equipment and circuits must be clearly
marked and identified. Label distribution panel and schematics accordingly.
46 CFR 183.220(d)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2021
Resolution: Labeled distribution panel. See documents tab for photo.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 28 September 2020
Resolved
Electric installations on vessels must ensure maintenance of system integrity through compliance with applicable system requirements(NEC) to which plan review has been approved. The wiring space of enclosures for switches or over-current devices shall be permitted for conductors spliced off other enclosures, switches, or over-current devices. Fire pump remote electrical connection was not spliced from an enclosure, switch or over-current device.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2020
Resolved 12 October 2020
Resolution: MI verified on deficiency check to vessel.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 31 August 2020
Resolved
A vessel that has a power driven fire pump must have a sufficient number of fire hydrants to reach any part of the vessel using a single length of firehose. Piping, valves, and fittings in a fire main system must comply with subpart G, part 182, of this chapter. Fire hydrant on the bow of the vessel was inoperable during test of fire pump and fire hydrant.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 September 2020
Resolved 28 September 2020
Resolution: Operator replaced seized valve and deteriorated fire hose. Proper operation proven.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 31 August 2020
Resolved
A fire pump must be capable of both remote operation from the operation station and local operations at the pump. Vessel did not have the capability of remote operation of the fire pump from the operation station.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 30 September 2020
Resolved 28 September 2020
Resolution: Vessel installed approved remote start/stop on the bridge.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 August 2020
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. The vessel’s gauge was inoperable at the time of inspection and Marine inspectors were unable to determine the fire main pressure.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 September 2020
Resolved 28 September 2020
Resolution: Vessel installed new operable guage on the firemain.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 August 2020
Resolved
The materials and construction of fuel lines, including pipe, tube, and hose must comply with requirements of this section. Tubing connections and fittings must be of nonferrous drawn or forged metal of the flared type. Marine inspector found fuel line on the port main diesel engine had a hardened epoxy type material over a suspected damaged connection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 September 2020
Resolved 28 September 2020
Resolution: Fuel line with epoxy was replaced with new fuel line.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 31 August 2020
Resolved
A power ventilation system must be capable of being shut down from the pilot house. Vessel did not have a remote ventilation shutdown in the pilot house.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 September 2020
Resolved 28 September 2020
Resolution: Remote shutdown installed with approved switch in the pilot house.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 31 August 2020
Resolved
Flexible nonmetallic hose may be used in non-vital water and pneumatic systems, subject to limitations of paragraph (d)(1) through (d)(4) of this section. Unreinforced hoses are limited to maximum service pressure of 340 kPa (50 psig), reinforced hoses are limited to a maximum service pressure kPa (150 psig). Hose connected to the air compressor in the engine room had a inadequate splice.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 September 2020
Resolved 28 September 2020
Resolution: New hose with the proper connection installed on the compressor in the engineroom.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 31 August 2020
Resolved
Each buoyant apparatus on the vessel on March 11 1996, may be used to meet the requirements of this part for these survival craft as long as the survival craft is continued in use on the vessel, and is in good and serviceable condition. Both port and starboard buoyant apparatuses are unauthorized usage on board the vessel since the vessel was built after the qualifying date.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 14 September 2020
Resolved 28 September 2020
Resolution: BA's removed from the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 31 August 2020
Resolved
An independent rudder angle indicator at the operation station. Rudder angle indicator was disconnected and unable to transmit rudder angle to the pilot house.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 September 2020
Resolved 28 September 2020
Resolution: Rudder angle indicator connected and tested to satisfaction of the MI.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 31 August 2020
Resolved
Except as otherwise provided in this section every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station. Vessel’s magnetic compass heading was not accurate and Captain could not provide records of the last compass swing test.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 September 2020
Resolved 28 September 2020
Resolution: Magnetic compass displaying the correct heading.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 31 August 2020
Resolved
A vessel on a lakes, bays, and sounds route must carry: Three hand red flare distress signals approved in accordance with 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel three hand red flares were expired in 2019.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 September 2020
Resolved 28 September 2020
Resolution: Vessel has 03 red flares and 03 orange flares with expiration date of year 2022.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 31 August 2020
Resolved
A weathertight door must be provided for each opening located in a deck house or companion way. The port and aft weathertight door gaskets were missing and damaged.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 September 2020
Resolved 28 September 2020
Resolution: Gaskets replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 31 August 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible. Vessel’s chart was not up-to-date.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 September 2020
Resolved 28 September 2020
Resolution: Vessel has current charts and publications.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 31 August 2020
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First Aid Kit”. A first aid kit must easily visible and readily available to the crew. Vessel’s first aid kit was missing the required items or medicine was well beyond the expiration date.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 September 2020
Resolved 28 September 2020
Resolution: Vessel has up to date first aid kit.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 31 August 2020
Resolved
An enclosed or partially enclosed space within a vessel must be adequately ventilated in a manner suitable for the purpose of the vessel. Port and stbd gooseneck vents for void spaces found with weathertight covered seized in the open position.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 September 2020
Resolved 28 September 2020
Resolution: Vent covers are functional and move freely.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 31 August 2020
Resolved
Vent pipes terminating on the hull exterior must be installed or equipped to prevent the accidental contamination of the fuel by water under normal operating conditions. Fuel vent covers were seized open due to corrosion.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 September 2020
Resolved 28 September 2020
Resolution: Fuel vents are functional and freely moves.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 31 August 2020
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. The vessel’s name was missing from 01 ring life buoy and faded/illegible from 02 ring life buoys.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 September 2020
Resolved 28 September 2020
Resolution: 03 Ring life buoys have appropriate stenciling of vessel's name.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 31 August 2020
Resolved
All cable and wires must: Be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. The use of plastic wire tie wraps must be limited to bundling or retention of multiple cable installations and not as a means of support. Port salt water feed pump power supply wire had no metal support bracket and was multiple wire tie wraps used for support.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 14 September 2020
Resolved 28 September 2020
Resolution: Required wire supports were installed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 31 August 2020
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Port handrail above the bulwark opening is corroded and rusted.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 September 2020
Resolved 28 September 2020
Resolution: Bulwark repaired to USCG MI satifaction.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 31 August 2020
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Vessels placard had incorrect call sign and operator was not aware of the vessel's current call sign.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 14 September 2020
Resolved 28 September 2020
Resolution: Vessel's Call Sign updated.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 2 October 2019
Resolved
Each life float must be Secured to the painter at one end and to the vessel on the other end. If the life float or buoyant apparatus does not have a painter attachment fitting, a means for attaching the painter must be provided by a wire or line that encircles the body of the device. Three life floats were in a "daisy chain" arrangement, two were tethered by wrapping around the grab line, and the overall consists' painter was not attached.
46CFR180.137
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 2 October 2019
Resolved 2 October 2019
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 October 2019
Resolved
Survival craft equipment. Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. The floating waterlight must be attached around the body of the life float. Several paddles were found deteriorated beyond serviceability, and two life floats had the waterlight attached to its grabline.
46 CFR 180.175
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 October 2019
Resolved 2 October 2019
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 October 2019
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry three hand red flare distress signals approved and three hand orange smoke distress signals. Vessel flares had expired SEP 2019. (705c Restricted to daytime operations only.)
46CFR 180.68
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 October 2019
Resolved 2 October 2019
Resolution: New flares submitted via photo.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 October 2019
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Each life jacket must be approved in accordance with either §160.002, §160.005, or §160.055 in subchapter Q of this chapter. Several "kapoc" type life preservers were found unsat during squeeze test. All life jackets were removed from storage and checked. Approximately 12-16 adult and youth kapoc life preservers failed, and were removed from vessel. Vessel inventory still exceeds COI requirement, no restrictions issued to vessel this deficiency.
46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 October 2019
Resolved 2 October 2019
Resolution: Bad "kapoc" life preservers removed from vessel. Onboard inventory still exceeds COI requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 October 2019
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Diesel generator found with oil weeping from vicinity engine/powerhead.
46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2019
Resolved 4 October 2019
Resolution: Troubleshooting revealed oil leak was bad oil filter gasket. Replaced filter and gasket, photo submitted (no longer leaking).
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 October 2019
Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use. A lifeline must be securely attached around the outside festooned in bights no longer than 3 feet. One (1) 22 pax life float found with several broken lifeline attachments/festoons. Repair prior to returning this device to service. (capacity exceeds COI required capacity, no restriction issued, requirement is to notify USCG when repaired or if changing total quantity of life floats).
46 CFR 185.700
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 October 2019
Resolved 22 October 2019
Resolution: Vsl operator provided email receipt of new 22 pax lifefloat.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 September 2018
Resolved
IMO: Vsl is broadcasting invalid IMO #, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information, SHIP TYPE MISSING: Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 6 January 2021
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 22 August 2018
Resolved
On a vessel of at least 26 ft, a visual and audible alarm must be provided at the operating station to indicate high water. Vessel not outfitted with audible alarm at the operating station. Install audible alarm at the operating station.
46 CFR 182.530
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2018
Resolved 24 September 2018
Resolution: Received video of properly operating audible alarm at operating station.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 August 2018
Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box where the extinguishing agent cylinders are stored. Vessel does not have instructions for CO2 operation. Provide instructions for operation of CO2 near CO2 room.
46 CFR 185.612
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2018
Resolved 24 September 2018
Resolution: Received photo of posted CO2 instructions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 August 2018
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Strainer for bilge suction in lazarette holed and wasted. Replace strainer.
46 CFR 182.510(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2018
Resolved 24 September 2018
Resolution: Received photo of newly installed strainer.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 August 2018
Resolved
Each child size life jackets must be stowed in a location that is appropriately marked and separated from adult life jackets. Child lifej ackets are stowed in a net in the overhead next to adult life jackets with no indication of which are adult and which are child. Mark stowage locations to differentiate child and adult life jackets.
46 CFR 180.78(a)(5)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2018
Resolved 24 September 2018
Resolution: Received photo for proper PFD stowage markings.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 August 2018
Resolved
All vessels must have navigation lights that are in compliance with the international and Inland Navigation Rules. Mastlight, sternlight, and starboard light were not operational. Repair inoperable navigation lights. Vessel restricted to daytime operation only.
46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2018
Resolved 17 October 2018
Resolution: Received photos for properly operating navigation lights.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 August 2018
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. Charts onboard are not up-to-date. Update charts or provide current chart.
46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2018
Resolved 24 September 2018
Resolution: Vessel updated current charts with corrections.
Engineering › Bilge Water Management System › Strainer
Issued 23 April 2018
Resolved
Forepeak strainer is corroded and partly missing. Replace with new. 46 CFR 182.25-5 Old 'T'
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2018
Resolved 25 April 2018
Lifesaving › Lifefloat › Netting
Issued 31 August 2017
Resolved
Repair Life Float netting, and the metallic base. Label all oars with vessel name. 46CFR180.200
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 12 September 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 31 August 2017
Resolved
Replace line attached to water lights on the ring buoys with a line that is buoyant, at least 60ft long, non-kinking, and of a dark color if synthetic. Note: we recommend adding a quick disconnect from the ring buoy and floating flag, although it is not required. 46CFR180.70
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 12 September 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 August 2017
Resolved
Protect steering indicator wiring in the steering gear space so that it is weather and water tight as well as protected from damage. 46CFR183.200
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 12 September 2017
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 31 August 2017
Resolved
Replace paper chats with newer additions and maintain chart corrections. 46CFR184.420(a)(1)
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 12 September 2017
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 31 August 2017
Resolved
Provide updated portions of the Coast Pilot. 46CFR184.420(a)(2)
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 12 September 2017