Records from 1999 to 2026. Most recent: inspection, 20 February 2026.
Inspection history · 28
20 February 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8313538
13 August 2025
PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8207286
3 May 2025
PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8120307
27 March 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8100786
23 July 2024
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7959912
26 February 2024
PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7867426
25 October 2023
PSC A
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7813883
22 December 2021
Ballast Water Examination · PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7369322
17 October 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6836284
11 July 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6745529
8 November 2018
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6574996
3 May 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6399196
11 August 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6237179
29 November 2016
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6046162
21 June 2016
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5915255
19 April 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5853513
22 March 2014
Ballast Water Examination · Deficiency Check · ISPS III Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4820861
26 January 2012
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4229071
26 January 2012
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4233305
27 October 2010
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3874685
5 March 2008
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3158182
15 July 2005
PII Safety Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2427879
23 November 2004
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2246603
25 July 2003
Type not recorded
No type recorded · USCGC KISKA (WPB 1336) · USCG Oceania District (CGD-O) · Activity 1877285
7 July 2003
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1838495
7 August 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1657750
13 February 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 287042
15 August 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 431368
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 July 2019
Resolved
02101 - Indicators shall be provided for all hinged doors in water tight bulkheads and show whether the doors are open or closed on the navigation bridge. Indicator lights on the navigation bridge had five inoperable water tight door indicators including doors throughout the STBD stairway and doors to the PORT and STBD embarkation areas, failing to indicate complete water tight integrity of the vessel.
SOLAS 74 (2001) II-1/23-1.2
17ac
Extended to 30JUL19 by Class Surveyor
Action required: 705 - Other - as specified
Due 30 July 2019
Resolved 11 July 2019
Resolution: Resolved by class survey report
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 11 July 2019
Resolved
08110 - Where vehicle ramps are installed to give access below the bulkhead deck their openings shall be alarmed and indicated on the bridge. The navigation bridge indicator panel indicator for side ramp indicated open when side ramp was closed.
SOLAS 74 (2001) II-1/20-2.1.2
17 ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2019
Resolution: Received class report attesting to the repairs.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 11 July 2019
Resolved
07123 - Structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions shall be kept in good working order so as to ensure their required performance if a fire occurs. Navigation bridge indicating panel for fire doors in stairwells in zone boundaries of the car decks are inoperable for four doors.
SOLAS 74 (2014) II-2/2.1.1.1
17ac
Class extended until 30JUL2019
Action required: 705 - Other - as specified
Due 30 July 2019
Resolved 11 July 2019
Resolution: Resolved by Class survey report
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 July 2019
Resolved
07105 - Stairways which penetrate a single deck and more than a single deck shall be protected by a self-closing door. The doors on the bridge, car deck 6 port side and care deck 9 port side were not self-closing. Port car deck door 6 also could not latch in the closed position.
SOLAS 74 (2001) II-2/46.1
17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2019
Resolution: Received class report attesting to the repairs.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 11 July 2019
Resolved
07122 - General arrangement plans shall be permanently exhibited showing means of access to different compartments. Fire control plan does not include door type designation in accordance with IMO Resolution A.952(23).
SOLAS 74 (2014) II-2/15.2.4.1
50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 October 2019
Resolution: Received Class report attesting to the amendment of the fire control plan.
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 11 July 2019
Resolved
10101 - A pilot ladder shall be certified by the manufacturer as complying with this regulation or with an international standard acceptable to the organization. 12th step from the bottom of the STBD pilot ladder is split with repaired by the crew after ladder certification.
SOLAS 74 (2014) V/23.2.3
50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 October 2019
Resolution: Received class report attesting to the replacement of the pilots ladder.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 July 2019
Resolved
03107 - The means for securing doors weather tightness shall consist of gaskets and clamping devices. The STBD bunker area door was missing gasket in the lower right corner.
ILLC (88 Protocol) 12
10c
Action required: 10 - Deficiency Rectified
Resolved 11 July 2019
Resolution: Corrected on the spot.
Pollution Prevention/Response
Issued 7 August 2002
Resolved
Oil Transfer Procedures were on board, however they did not adequately comply with the requirements in 33 CFR 155.750. Vessel is not allowed to take on bunkers in U.S. waters until proper Transfer Procedures are provided and inspected by a U. S. Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Oil Transfer Procedures
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 August 2002
Resolution: Item cleared.