Records from 1998 to 2017. Most recent: inspection, 13 June 2017.
Inspection history · 30
13 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6175036
13 June 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6175666
19 September 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6004083
27 August 2015
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5232287
8 August 2011
Hull Examination · Administrative Inspection · MTSA Verification · Annual Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check · Examination of Repairs · Cargo Tank Internal
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4110577
21 August 2008
Ballast Water Examination · Deficiency Check · Administrative Inspection · Periodic Inspection · Hull Examination · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3304579
28 February 2007
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2879478
26 January 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2887770
23 October 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806564
23 October 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2806570
31 July 2006
MTSA Verification · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2731134
7 January 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2562633
10 October 2005
Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2511342
15 September 2005
MTSA Verification · COI Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2492954
25 February 2005
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2299232
18 February 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2295332
16 December 2004
MTSA Verification · Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2261151
14 August 2003
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1875846
15 January 2003
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1730789
14 January 2003
Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1729958
19 December 2002
Periodic Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1721246
2 August 2001
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405241
26 March 2001
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 769364
24 March 2001
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 202306
22 September 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1361784
26 November 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468097
9 March 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803042
23 February 1999
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 692816
18 December 1998
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 202307
30 September 1998
Inclining Experiment · Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434787
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 13 June 2017
Resolved
Any certificate required by the convention must be kept available in its original form on board the ship on which the holder is serving. First officer, Vemal Hymeanus Black, does not have original national certificate on board the vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 July 2017
Resolved 15 June 2017
Resolution: Vessel received original national license for 1st officer. Verified by attending Coast Guard inspector.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 18 August 2011
Resolved
During man overboard drill the motor on the rescue boat failed to operate properly. Once started, the motor would idle but then died as the throttle was advanced and it was hard to restart. Vessel owner is to present a fully operable rescue boat and motor to the attending MI for examination.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2011
Resolution: Rescue boat motor was replaced with another motor. Attending MI witnessed operational test of rescue boat.
Engineering › Freshwater System (jacketwater cooling) › Valve, Control
Issued 15 September 2005
Resolved
Replace keel cooler valve assembly located in port bilge.
Action required: 705 - Other - as specified
Due 15 October 2005
Resolved 29 September 2005
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 15 September 2005
Resolved
Double nut shaft packing bolts and tighten shaft packings.
Action required: 705 - Other - as specified
Due 15 October 2005
Resolved 15 September 2005
Lifesaving › Lifebuoys › Approval
Issued 15 September 2005
Resolved
Add retro tape to port side life ring.
Action required: 705 - Other - as specified
Due 15 October 2005
Resolved 15 September 2005
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 15 September 2005
Resolved
Remove excessive oily water from bilge.
Action required: 705 - Other - as specified
Due 15 October 2005
Resolved 28 September 2005
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 December 2002
Resolved
Determin/resolve problem w/24V DC emergency lighting system.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 20 December 2002
Documentation › Safety/Response Plans/Programs
Issued 19 December 2002
Resolved
Update fire/lifesaving plan. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 January 2003
Resolved 13 January 2003
Resolution: Recieved faxed documentation of completion.
Construction/Loadline › Markings › Load Line Mark
Issued 19 December 2002
Resolved
Re-paint load lines
Due 19 January 2003
Resolved 20 December 2002
Engineering › Steering Gear System
Issued 19 December 2002
Resolved
Install steering limit switch to prevent steering from hitting stops.
Condition: Improper Installation
Due 19 January 2003
Resolved 13 January 2003
Resolution: Recieved verification from Master of vessel switches were adjusted.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 19 December 2002
Resolved
Replace plugs in containment.
Due 19 December 2002
Resolved 19 December 2002
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 December 2002
Resolved
Replace expired meds/eyewash solutions.
Condition: Improper/Lack of Maintenance
Due 19 December 2002
Resolved 20 December 2002
Documentation
Issued 26 November 1999
Resolved
PROVIDE COAST GUARD APPROVED AUTOMATION TEST PROCEDURES TO THE SATISFACTIONOF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 26 December 1999
Resolved 1 December 1999
Electrical
Issued 26 November 1999
Resolved
DEMONSTRATE PROPER OPERATION OF PORT GENERATOR OVERSPEED TRIP TO THE SATISFACTON OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 26 December 1999
Resolved 15 December 1999
Documentation
Issued 30 September 1998
Resolved
SUBMIT SOPEP FOR APPROVAL AND PROVIDE ON BOARD NO LATER THAN 01JAN99.
Condition: Unknown
Due 30 September 1998
Resolved 30 September 1998