Records from 2016 to 2021. Most recent: inspection, 7 December 2021.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 3 February 2026
Resolved
A hydrostatic release unit must be approved under approval series 160.062. The hydrostatic release units on the liferafts are missing the expiry dates.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2026
Resolved 9 February 2026
Resolution: MI verified compliance
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 February 2026
Resolved
A vessel that operates on the high seas much have on board a FCC Type Accepted 1 406 MHZ EPRIB installed to automatically float free and activate. The hydrostatic release unit is missing expiry date.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2026
Resolved 9 February 2026
Resolution: MI verified compliance
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 February 2026
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Vessel was not equipped with 01 portable hand bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2026
Resolved 9 February 2026
Resolution: MI verified compliance
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 3 February 2026
Resolved
A vessel of not more than 65 feet in length is not required to carry a rescue boat unless… the cognizant OCMI determines that the vessel is designed, arranged, or involved in operations so that the vessel itself cannot serve as an adequate rescue craft. Vessel was not equipped with a boat hook to recover persons in the water and a tether on the rescue platform to secure rescued persons.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2026
Resolved 9 February 2026
Resolution: MI verified compliance
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 3 February 2026
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Complete and log abandon ship drill prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2026
Resolved 10 February 2026
Resolution: MI verified compliance
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 3 February 2026
Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Complete and log fire fighting drill prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2026
Resolved 10 February 2026
Resolution: MI verified compliance
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 February 2026
Resolved
Means of escape must be adequately marked on both sides in clearly legible letters at least 2 inches high: "EMERGENCY EXIT, KEEP CLEAR." Means of escape is missing from both side of hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2026
Resolved 10 February 2026
Resolution: MI verified compliance
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 February 2026
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and at the access to the propulsion machinery space. Portable lights were missing from operating station and propulsion machinery space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2026
Resolved 10 February 2026
Resolution: MI verified compliance
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 February 2026
Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.50 in subchapter Q. Each ring life buoys are missing retroreflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2026
Resolved 10 February 2026
Resolution: MI verified compliance
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 February 2026
Resolved
A vessel not required to have a power driven pump must have at least three 2.5 gallon buckets, with an attached lanyard. Missing one fire bucket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2026
Resolved 10 February 2026
Resolution: MI verified compliance
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 February 2026
Resolved
All electrical equipment and circuits must be clearly marked and identified. The distribution panel was missing labeling for each circuit breaker.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2026
Resolved 10 February 2026
Resolution: MI verified compliance
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 3 February 2026
Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. Vessel does not have an anchor on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2026
Resolved 10 February 2026
Resolution: MI verified compliance
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 April 2021
Resolved
Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. It shall be gas-tight throughout its length and shall be properly supported by non-combustible hangers or blocks. Vessel’s port side main diesel engine exhaust piping has deterioration and a one-eighth inch diameter hole. Vessel must replace exhaust piping and restore system as designed.
46 CFR 182.15-20(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 April 2021
Resolution: Crew fitted and installed new section of exhaust piping.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 April 2021
Resolved
All vessels except non-self propelled vessels shall be provided with suitable steering apparatus. Starboard side rudder packing gland flange is missing retainer bolts and is loose. Vessel must install hardware and restore steering system as designed.
46 CFR 182.30-1(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 April 2021
Resolution: Crew installed new hardware for the starboard side rudder packing gland flange and restored system as designed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 13 April 2021
Resolved
A hatch cover must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Hatch cover for the forepeak space is missing its securing device mechanism. Vessel must restore valve handle and securing device mechanism to restore hatch cover as designed.
46 CFR 179.360(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 April 2021
Resolution: Crew restored valve handle and associated securing device mechanism for the forepeak hatch cover.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 13 April 2021
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Vessel’s 12-person life float has a broken lifeline. Vessel must replace lifeline as per manufacturer specification.
46 CFR 180.175(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2021
Resolution: Crew replaced lifeline and restored life float.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 April 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Onboard first-aid kit has expired eye wash solution. Vessel must provide replacement eye wash solution.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 April 2021
Resolution: Crew provided new eye wash solution for the first-aid kit.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 April 2021
Resolved
All electrical installations shall be to the satisfaction of the officer in charge, marine inspection. Four-foot fluorescent light cover located on the starboard forward overhead accommodation space is damaged. Vessel must replace cover as designed.
46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 April 2021
Resolution: Crew installed new cover and restored four-foot fluorescent light.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 April 2021
Resolved
All electrical installations shall be to the satisfaction of the officer in charge, marine inspection. Battery box located on the port side engine room has excess electrolyte within the container. Vessel must ensure no spillage of electrolyte mixture and cleanliness of battery box.
46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 April 2021
Resolution: Crew completed clean-up and recovery of electrolyte mixture for the port side engine room battery box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2021
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Engine room switchboard has an empty slot exposing internals.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2021
Resolved 13 April 2021
Resolution: Crew installed cover plate over empty slot exposing switchboard interior.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 15 April 2020
Resolved
Each vessel must be equipped with at least two operable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Both portable lights were missing and vessel was unable to find two portable lights.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2020
Resolved 24 April 2020
Resolution: Portable lights replaced with fuctional battery powered portable lights.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 15 April 2020
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such manner as to afford adequate precaution against hazards that might endanger the vessel and persons being transported. Vessel's medium frequency radio inoperable and vessel is limited to 20nm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2020
Resolved 24 April 2020
Resolution: Letter requesting change of route was submitted. COI will be amended to show route change to 20nm instead of 100nm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2020
Resolved
Any cabinet, panel, or box containing more than one source of potential in excess of 24 volts shall be fitted with a permantent sign warning personnel of this condition and identify the circuits to be disconnected to remove all potentials in excess of 24 volts. #3 and #5 breakers missing in pilot house distribution panel.
46 CFR 183.10-10(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2020
Resolved 24 April 2020
Resolution: #3 and #5 breakers replaced with proper size and amperage breakers.
10 - Safety of Navigation › N/A - No Subsystem › Communication-SOLAS chap. 5
Issued 15 April 2020
Resolved
A durable placard must be posted next to all radios. Telephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Vessel's emergency broadcast placard was not updated with correct call sign and faded words.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 29 April 2020
Resolved 15 April 2020
Resolution: Vessel representative corrected call sign on emergency placard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 15 April 2020
Resolved
Gauges to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines. Port and starboard jacketwater gauges inoperable.
46 CFR 182.20-5(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2020
Resolved 28 April 2020
Resolution: Guages replaced in kind.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 May 2019
Resolved
Vessel that is issued a Certificate of Inspection must not be operated without a Valid Certificate Expiration Sticker affixed to the vessel. Certificate Inspection Sticker was missing. Install Certificate of Inspection Sticker IAW 46 CFR 176.310 (b) to the satisfaction of the cognizant OCMI.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 15 May 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 May 2019
Resolved
Each junction box must have a cover.
While conducting inspection of E/R observed junction box without cover in overhead aft centerline. Install cover IAW 46 CFR 111.81-1 (c) to the satisfaction of the cognizant OCMI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 16 May 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 May 2019
Resolved
Each battery installation must be located in a well ventilated space and protected from falling objects. Battery box was found with inoperable cover that did not protect batteries from falling objects. Install cover IAW 46 CFR 183.354 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 16 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 6 August 2018
Resolved
A space of less than 14 cubic meters (500 cubic feet) in volume must have a gooseneck vent of not less than 40 millimeters (1.5 inches) in diameter. Vessel's gooseneek vent for the lazarette space was removed and shall be properly reinstalled.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2018
Resolved 13 August 2018
Resolution: Vessel installed gooseneck vent for lazarette space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 August 2018
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a)provided that the pump is permanently mounted. Vessel has an electrical submersible bilge pump in the lazarette space that is not permanently mounted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2018
Resolved 13 August 2018
Resolution: Vessel permanently mounted the electrical submersible bilge pump in the lazarette space (bilge below lower passenger compartment).
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 6 August 2018
Resolved
Where rigid nonmetallic material is permitted for use in piping systems an acceptable metallic shutoff valve is installed adjacent to the through hull fitting. Vessels valve handle for the overboard from the sinks located in the Male Head is heavily corroded and inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 August 2018
Resolved 6 August 2018
Resolution: Vessel installed new valve handle.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 9 May 2017
Resolved
FCC Radio Safety Radiotelephony Certificate has incorrect call sign.
Action required: 705 - Other - as specified
Due 23 May 2017
Resolved 1 June 2017
Resolution: Vessel Rep had entire fleet scheduled and corrected all fleet call signs to vessel call signs. was granted an extension to due date due to FCC Inspector Schedule. Inspected all documents. All Information is correct and sat.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 20 April 2017
Resolved
propeller has excess pitting on blade and hub. Leading edge dented. 2 cracks visible on 2 seperate blades blades (1/4"). Marine inspector may require any part or all of the propeller shafting to be drawn for examination of the shafting and stern bearing of a vessel whenever the conditions of the shafting and bearings are in question.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 25 April 2017
Resolution: Installed new propellers port and starboard side.