MAURY USCG vessel records Sign in
← All vessels

AMERICAN HIGHWAY

AMERICAN HIGHWAY is a 2000 freight ship. The Coast Guard has recorded 32 inspections since 2000, most recently in September 2023, along with 5 deficiencies.

Records from 2000 to 2023. Most recent: inspection, 26 September 2023.

Built
2000
Last inspected
26 September 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9205976 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-4732

Inspections, by type

…with no type recorded10
Years with a record 15 calendar years (2000–2023)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it30973 - Displacement, Ton
16750 - Dead Weight, Ton
49212 - Convention (Subpart B), Gross Ton
14764 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 32

26 September 2023 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7798580
11 March 2023 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7645687
9 September 2022 PSC A
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7549615
22 October 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6837424
17 February 2018 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6356797
1 February 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6347281
3 November 2017 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6299935
18 October 2017 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6289918
5 March 2017 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6099985
26 December 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6060967
10 December 2015 Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5779163
4 December 2015 COE-Dockside · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5772046
28 August 2011 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4128992
11 July 2011 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4073906
19 November 2007 Ballast Water Examination · MARPOL Annex I Examination · ISPS III Exam · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3098311
23 September 2007 ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3061109
27 July 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2726852
23 February 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2590931
17 November 2005 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2536727
17 August 2005 ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2466037
1 August 2005 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2448238
22 December 2004 PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2263421
26 July 2004 ISPS II Exam
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2146047
27 April 2004 Ballast Water Examination · MARPOL Annex I Examination · Annual Inspection · MTSA/ISPS Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2054001
27 April 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2076839
27 April 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2077900
17 December 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1720059
15 December 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1718764
25 November 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 295716
2 April 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 288649
2 April 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 289422
12 April 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 276663

Deficiency record · 5

Lifesaving › Lifeboat › Propulsion Transmission
Issued 1 February 2018 Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Port side lifeboat is inoperable due to defective reduction gear clutch. Lifeboat cannot move ahead or astern. SOLAS 74 (14 cons.) III/20.2
Action required: 705 - Other - as specified
Due 15 February 2018
Resolved 17 February 2018
Resolution: Class attended vessel and verified proper repairs and operation of the port side lifeboat. Class report received.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 December 2015 Resolved
MARPOL 73/78 ANNEX 1/11 ISM CODE PART A.7 50ac SEE NARRITIVE FOR COMPLETE DISCRIPTION OF DEFICIENCY.
Action required: 705 - Other - as specified
Due 4 January 2016
Resolved 10 December 2015
Resolution: Class (NKK) and a service tech attended the ship and made proper repairs to the OWS and OCM. Additionaly, training was given to the engineering officers.
Electrical › Electric Generation Source (emergency) › Panelboard
Issued 4 December 2015 Resolved
74 SOLAS (2004) II-1/43.2 DURING OPERATIONAL TEST OF EMERGENCY GENERATOR THE HERTZ WERE MAXED OUT. CREW MADE ADJUSTMENTS TO THE THROTTLE TO PRODUCE 60 HERTZ AS WITNESSED BY PSCO AND CLASS SURVEYOR. 10c
Due 4 December 2015
Resolved 4 December 2015
Resolution: CREW MADE ADJUSTMENTS TO THE THROTTLE TO PRODUCE 60 HERTZ AS WITNESSED BY PSCO AND CLASS SURVEYOR.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 11 July 2011 Resolved
BUNKERING LINE HAS NOT BEEN HYDROSTATICALLY TESTED WITHIN THE LAST YEAR. A SUCCESSFUL HYDROSTATIC TEST MUST BE PERFORMED PRIOR TO BUNKERING OPERATION IN U.S. WATERS. 33CFR156.170(C)(4)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 August 2011
Resolution: Received satisfactory test of bunkering lines that was conducted by ship’s crew. (See attached documents)
Accommodation/Occupational Safety › Potable Water System › General
Issued 4 August 2005 Resolved
Remove water faucet and piping from reefer space directly next to the switchboard to reduse risk of electrical shock and bodily harm to the crew IAW Solas 74/76 amended CH. II-1/45.2.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 August 2005
Resolution: Recieved email from the vessel''s captain via the agent attesting to the removal of the water faucet and piping in the reefer space next to the switchboard. Vessel sent color pics of removal process, all sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.