MAURY USCG vessel records Sign in
← All vessels

SEACOR VANTAGE

SEACOR VANTAGE is a 1998 offshore supply vessel. The Coast Guard has recorded 37 inspections since 1998, most recently in June 2019, along with 38 deficiencies and 1 casualty investigation in 2005.

Records from 1998 to 2019. Most recent: inspection, 3 June 2019.

Built
1998
Last inspected
3 June 2019
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9196694 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCY5598
473247
Flag
UNITED STATES
366259000 (licence lapsed)
Maury page id
psix-473247

Inspections, by type

…with no type recorded5
Years with a record 16 calendar years (1998–2019)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)221.8 ft × 52.0 ft × 22.0 ft
Registered tonnagegross 2,283 / net 684
ITC dimensions (L × B × D)221.8 ft × 52.0 ft × 22.0 ft
ITC tonnagegross 2,283 / net 684
BuilderMOSS POINT MARINE INC · ESCATAWPA, MS, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2283 - Convention (Subpart B), Gross Ton
684 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY5598MMSI 366259000 · expired · compulsorily equipped · granted 20 May 2008, cancelled 15 September 2018
WDA5324MMSI 366259000 · cancelled · compulsorily equipped · granted 12 July 2001, cancelled 25 May 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

NOBLE JIM THOMPSON Mobile Offshore Drilling Unit · MISLE 53936 · 16 September 1999 · activity 64502

Inspection history · 37

3 June 2019 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6702058
5 April 2016 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5876508
19 August 2014 Administrative Inspection · MARPOL Annex II Examination · Annual Inspection · MARPOL Annex IV Survey · MARPOL Annex VI Survey · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4959983
19 July 2012 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4383159
22 January 2010 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3668284
9 September 2008 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3321103
1 July 2008 Plan Review (Other than "T")
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 3255922
17 June 2008 Internal Structural Exam · Deficiency Check · Periodic Inspection · MTSA/ISPS Verification · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3239409
4 September 2007 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3073671
31 July 2006 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2717965
23 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2571480
7 June 2005 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2382293
1 April 2005 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2323280
15 March 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2315657
4 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2303716
10 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290214
1 November 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2232683
29 August 2004 Annual Inspection · Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2189596
20 July 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2139609
20 June 2004 MTSA/ISPS Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2066498
17 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1966063
11 June 2003 Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1852740
5 September 2002 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1671035
27 August 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1666947
12 August 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1660075
6 September 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425204
20 April 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 142608
5 October 2000 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1424978
11 August 2000 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 821574
20 June 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381929
30 September 1999 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1347259
16 September 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 64502
27 August 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1420183
13 July 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1097196
8 November 1998 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 178107
26 October 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 809459
26 June 1998 Initial Certification · Hull Examination · Inclining Experiment · Construction Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1372521

Deficiency record · 38

Lifesaving › Rescue Boat › Propulsion Engine
Issued 19 August 2014 Resolved
Rescue boat would not start during man-overboard drill.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2014
Accommodation/Occupational Safety › Ventilation › General
Issued 19 August 2014 Resolved
Flame screens on several vents had holes in them. Ensure new flame screens are installed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 September 2014
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 19 July 2012 Resolved
Vsl does not comply with 74SOLAS(97 Cons) II-2/5.1.13 - The storage area for the CO2 bottles is NOT situated in a safe and readily accessible. When I walked into the CO2 area, the space was completely filled with clutter with objects hanging from the overhead banging on the CO2 piping. Additional clutter would prevent fast access to safely operate system. Vsl needs to remove all non-related CO2 eq
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 3 August 2012
Resolution: Vsl has cleared all clutter from CO2 room.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 19 July 2012 Resolved
The SCBA harness that are part of the fireman outfits are not NFPA approved and not suitable for fire. Vsl needs to replace prior to conducting coastwise trade.
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 3 August 2012
Resolution: Vsl has cleared all defs.
Engineering › Compressed Air System (start air) › Valve
Issued 19 July 2012 Resolved
Air receiver pressure relief valves are not suitable for MAWP of air receiver. The MAWP of air receiver and the pressure the relief valve was set were both 250 psi. Informed chief engineer to replace the valve with a relief valve no more than 200 psi (+/- 10% IAW Sub-F).
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 3 August 2012
Resolution: All defs have been cleared.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 July 2012 Resolved
The port inboard MDE exhaust lagging had excessive oil on it. Need to replace all oil soaked lagging.
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 3 August 2012
Resolution: All defs have been cleared.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 17 June 2008 Resolved
Provide life saving training manual as per SOLAS chapter III reg. 35 and fire fighting training manual as per SOLAS chapter II-2 reg. 14.
Due 25 August 2008
Resolved 9 September 2008
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 17 June 2008 Resolved
Provide for approval engineering automation test procedures and operations manual as per 46 CFR 130.480
Due 25 August 2008
Resolved 4 August 2008
Engineering › Fuel Oil Service System › Valve
Issued 4 September 2007 Resolved
Make operable three inoperable fuel shutoff rerach rods from the open deck.
Due 30 October 2007
Resolved 8 September 2007
Lifesaving › Inflatable Liferafts › Capacity
Issued 31 July 2006 Resolved
Provide extra liferafts to comply with SOLAS III/31.1.3 prior to sailing international or within 30 days.
Condition: Improper Installation
Due 31 August 2006
Resolved 30 August 2006
Resolution: Master faxed completed worklist item.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 31 July 2006 Resolved
Provide required steering failure alarm.
Condition: Improper Installation
Due 30 September 2006
Resolved 31 July 2006
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 31 July 2006 Resolved
Provide 2 floating leaders for line-throwing apparatus.
Condition: Improper Installation
Due 31 August 2006
Resolved 30 August 2006
Resolution: Master faxed completed worklist item.
Lifesaving › Rescue Boat › Propeller
Issued 31 July 2006 Resolved
Provide propeller guard for SOLAS rescue boat.
Condition: Improper Installation
Due 31 August 2006
Resolved 30 August 2006
Resolution: Master faxed completed work list item.
Lifesaving › Rescue Boat Equipment › First Aid Kit
Issued 31 July 2006 Resolved
Renew First Aid kit for Rescue Boat.
Condition: Improper/Lack of Maintenance
Due 31 August 2006
Resolved 30 August 2006
Resolution: Master faxed that a new kit was provided.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 31 July 2006 Resolved
Make all machinery space doors self-closing, remove all hold back arrangements.
Condition: Improper Installation
Due 31 August 2006
Resolved 30 August 2006
Resolution: Master faxed report that hold backs removed, and self-closing devices being installed.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 29 August 2004 Resolved
Prove proper operation of OWS system.
Due 29 September 2004
Resolved 27 September 2004
Stability › Watertight Integrity › General
Issued 29 August 2004 Resolved
Prove proper operation of all watertight doors.
Due 29 September 2004
Resolved 27 September 2004
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 29 August 2004 Resolved
Prove all transfer fuel hoses are properly tested and labeled.
Due 29 September 2004
Resolved 27 September 2004
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 29 August 2004 Resolved
Replace lagging near turbo on #2 main diesel engine.
Due 29 September 2004
Resolved 27 September 2004
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 29 August 2004 Resolved
Prove fuel leaks at fuel transfer station are fixed.
Due 29 September 2004
Resolved 27 September 2004
Engineering › Steering Gear System › Actuator
Issued 29 August 2004 Resolved
Prove hydraulic leak in steering compartment is fixed.
Due 29 September 2004
Resolved 27 September 2004
Engineering › Fuel Oil Service System › Valve, Control
Issued 29 August 2004 Resolved
Properly label emergency fuel reach rods.
Due 29 September 2004
Resolved 27 September 2004
Lifesaving › Visual Distress Signals (General) › Expired
Issued 29 August 2004 Resolved
Prove expiration dates on both smoke flares.
Due 29 September 2004
Resolved 27 September 2004
Communications › Radio Communications › Emergency Source of Power
Issued 29 August 2004 Resolved
Prove proper operation of GMDSS, without "Alarm Unit Error", and that unit "link" is maintained at all times.
Due 29 September 2004
Resolved 27 September 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 29 August 2004 Resolved
Replace fire extinguishers in rescue boat and galley.
Due 29 September 2004
Resolved 30 September 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 August 2002 Resolved
NOT STENCILED PROPERLY
Action required: 17 - Rectify deficiencies prior to departure
Due 12 September 2002
Resolved 12 August 2002
Documentation › Markings/Placards
Issued 12 August 2002 Resolved
MISSING SEVERAL IMO SYMBOLS THROUGHOUT VESSEL. LEGACY COMPONENT DESC: IMO SYMBOLS
Due 12 September 2002
Resolved 5 September 2002
Resolution: COMPLETED POSTING REQUIRED SYMBOLS.
Lifesaving › Lifebuoys
Issued 12 August 2002 Resolved
CONDEMNED 4 LIFERINGS DUE TO UNSERVICEABILITY. LEGACY COMPONENT DESC: CONDITION
Action required: 17 - Rectify deficiencies prior to departure
Due 12 September 2002
Resolved 12 August 2002
Navigation › Collision/Grounding Avoidance
Issued 12 August 2002 Resolved
DEPTH SOUNDER NOT ABLE TO RECORD CONTINOUSLY. LEGACY COMPONENT DESC: Echo-sounding Device Recorder
Due 12 September 2002
Resolved 12 August 2002
Fire Fighting › Ventilation Systems
Issued 12 August 2002 Resolved
NO MEANS OF SECURING VENTILATION ON ENGINEROOM VENTS.
Action required: 705 - Other - as specified
Due 12 August 2002
Resolved 5 September 2002
Resolution: VESSEL SUBMITTED PROOF OF INTERNAL VENTILATION CLOSURES THAT WILL CLOSE IN THE EVENT OF A ENGINEROOM FIRE.
Stability › Watertight Integrity
Issued 12 August 2002 Resolved
ADJUST ALL WATER TIGHT DOORS. LEGACY COMPONENT DESC: WATER TIGHT DOORS.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 September 2002
Resolved 12 August 2002
Navigation
Issued 20 June 2000 Resolved
PROVIDE MANEUVERING DATA IAW 33 CFR 164.35, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Deck/Cargo
Issued 20 June 2000 Resolved
DEMONSTRATE PROPER OPERATION OF THE REMOTE LIQUID MUD PUMP SHUT DOWNS, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Fire Fighting
Issued 27 August 1999 Resolved
PROVIDE NUMBERING OF FIRE STATIONS, SEVERAL TAGS MISSING.
Condition: Unknown
Due 27 August 1999
Resolved 27 August 1999
Electrical
Issued 27 August 1999 Resolved
REPLACE SHORE TIE W/ PROPER CAP.
Condition: Unknown
Due 27 August 1999
Resolved 27 August 1999
Deck/Cargo
Issued 26 June 1998 Resolved
PROVIDE ON VESSEL ABS APPROVED CARGO SECURING MANUAL.
Condition: Unknown
Due 18 August 1998
Resolved 13 May 1999
Engineering
Issued 26 June 1998 Resolved
PROVIDE ON BOARD VESSEL APPROVED PERIODIC SAFETY TEST PROCEDURES.
Condition: Unknown
Due 8 July 1998
Resolved 13 May 1999
Documentation
Issued 26 June 1998 Resolved
PROVIDE ON BOARD VESSEL CARGO RECORD BOOK._x001C_
Condition: Unknown
Due 26 June 1998
Resolved 15 May 1999

Casualty record · 1

15 March 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2315657
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.