UFO

UFO is a 1998 passenger vessel (inspected). The Coast Guard has recorded 35 inspections since 1998, most recently in January 2026, along with 27 deficiencies and 1 casualty investigation in 2012.

Records from 1998 to 2026. Most recent: inspection, 21 January 2026.

Built
1998
Last inspected
21 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ3549
473255
Flag
UNITED STATES
367410510
Maury page id
psix-473255

Inspections, by type

…with no type recorded3
Years with a record 23 calendar years (1998–2026)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)28.0 ft × 10.0 ft × 8.0 ft
Registered tonnagegross 15 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPREMIUM PARASAIL BOATS · CAPE CORAL, FL, UNITED STATES · built 1998
Hull materialFRP (Fiberglass)
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portKAANAPALI, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Simplified, Gross Ton
12 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCZ3549MMSI 367410510 · active · compulsorily equipped · granted 10 May 2019, expires 28 June 2029
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 35

21 January 2026 Administrative Inspection
Administrative · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8299772
16 October 2025 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8253725
17 October 2024 Annual Inspection · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8020216
14 November 2023 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7824329
19 October 2022 COI Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7580129
5 October 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7596994
5 November 2020 COI Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7087490
23 April 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6668111
29 March 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6652234
17 November 2018 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6582392
13 March 2018 COI Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6371242
30 November 2016 Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6049653
13 May 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5923088
6 May 2014 Annual Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4897854
3 May 2012 Annual Inspection · DAPI Audit · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4301474
6 May 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3468796
15 May 2008 Hull Examination · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3206496
17 May 2007 Simplified Stability Test · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2933143
27 April 2006 COI Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2634990
5 May 2005 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2350373
14 May 2004 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2070629
29 April 2004 Annual Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2056417
2 June 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1807942
19 July 2002 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1649007
28 May 2002 Deficiency Check · Hull Examination · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1639739
18 May 2002 Type not recorded
No type recorded · Station Honolulu · USCG Oceania District (CGD-O) · Activity 1620228
16 March 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1064640
7 March 2001 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1382154
5 June 2000 Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1415389
2 March 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 33628
9 July 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1092786
10 May 1999 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1129243
28 April 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1381559
23 July 1998 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 797995
18 April 1998 Hull Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424601

Deficiency record · 27

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 October 2025 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). A submersible electric bilge pump may be used provided that: The pump is listed by an independent laboratory as meeting the requirements in UL 1113. Aft bilge pump not meeting the requirements of UL 1113. Pump requires renewal. 46CFR182.520
Action required: 10 - Deficiency Rectified
Resolved 16 October 2025
Resolution: UL Listed RULE 2000 pump installed during inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 October 2022 Resolved
Vessel must undergo an annual inspection within 3 months before or after each anniversary date. Anniversary date for UFO is November 5th. COI was initially issued on 5 Nov 2020. Vessel missed 2021 inspection which should have occurred from 5 Aug 2021 to 5 Feb 2022. On Oct 5 2022 it was found that the vessel missed the 2021 inspection. Vessel restricted from carrying passenger until inspection completed. 46 CFR 176.500(b)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2022
Resolution: Inspection completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 November 2020 Resolved
Damage to keel forward and damage to starboard strake forward requiring fiber glass repairs. Grind areas to good materiel and make proper repair in accordance with NVIC 8-87 chapter 6.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 28 December 2020
Resolution: Repairs made to hull.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 November 2020 Resolved
02 fire buckets cracked. Provide 02 new fire buckets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 17 December 2020
Resolution: New fire buckets provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 November 2020 Resolved
Life Ring Buoy secured to bracket by screw. Make life ring buoy ready to be rapidly cast loose at all times.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 17 December 2020
Resolution: Life Ring ready to cast loose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 November 2020 Resolved
High water bilge alarms visual/ audible indicators not functioning as designed. Bilge high water alarms shall have visual and audible indicators at operating station.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2020
Resolved 17 December 2020
Resolution: High water bilge alarm functioning.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 November 2020 Resolved
Dead end wire located in front of helm. Remove dead end wire and update electrical drawing once wire is removed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 17 December 2020
Resolution: Dead end wire removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 November 2020 Resolved
Machinery space boundary insulation on engine hatch is missing. Boundary must be lined with noncombustible panels or insulation approved IAW 164.009.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 17 December 2020
Resolution: New boundary insulation installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 November 2020 Resolved
Forward hatch under chain locker had standing water. U-bolt leaking water into space. Make repair to U-bolt.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2020
Resolved 17 December 2020
Resolution: Repair to U-bolt completed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 17 November 2018 Resolved
Engine compartment bilge alarm was inoperative. Repair in accordance with 46 CFR 182.530.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2018
Resolution: Alarm operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 November 2018 Resolved
Ring buoy was unsatisfactory. Renew in accordance with 46 CFR 176.808.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2019
Resolution: Ring buoy renewed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 November 2018 Resolved
Navigation lights were inoperative. Repair in accordance with 46 CFR 183.420. Vessel restricted to daylight operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 March 2019
Resolution: Navigation lights repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 17 November 2018 Resolved
Unauthorized penetration for a speaker was cut into engine compartment cover. Seal penetration in accordance with 46 CFR 176.700.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 March 2019
Resolution: Penetration sealed.
Communications › Radio Communications › VHF Radiotelephone
Issued 13 March 2018 Resolved
Vessel needs to show that its onboard FCC Radio is configured as Class D as required in 47 CFR 80.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 April 2018
Resolved 20 April 2018
Resolution: The company installed a programmed Class D radio onboard the vessel.
Engineering › Steering Gear System › Rudder
Issued 13 March 2018 Resolved
Vessel needs to provide an auxiliary means of steerage onboard in accordance with 46 CFR 182.620.
Action required: 705 - Other - as specified
Due 2 April 2018
Resolved 13 March 2018
Resolution: The company provided the vessel with oars as a means of auxiliary steering.
Lifesaving › Lifebuoys › Serviceable
Issued 13 May 2016 Resolved
Lifering was worn and would not make it tell next inspction.
Due 15 June 2016
Resolved 16 May 2016
Resolution: Vessel bought new lifering.
Engineering › Bilge Water Management System › Valve
Issued 6 May 2009 Resolved
PROVIDE POSITIVE ACTION SHUT OFF VALVE FOR EACH SUBMERSIBLE ELECTRIC BILGE PUMP IN WAY OF DISCHARGE HOSE AND HULL PENETRATION.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 12 May 2009
Engineering › Fuel Oil Service System › Piping
Issued 29 April 2004 Resolved
Provide SAE-J1942 fuel hoses and proper hose fittings.
Condition: Unknown
Due 20 May 2004
Resolved 27 April 2005
Engineering › Bilge Water Management System
Issued 29 April 2004 Resolved
Provide visual alarm for automatic bilge pump. LEGACY COMPONENT DESC: Interface Detector
Condition: Unknown
Due 20 May 2004
Resolved 14 May 2004
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 29 April 2004 Resolved
Vessel not allowed to carry passengers until fixed fire system tested and approved by qualified tech. LEGACY COMPONENT DESC: Tanks
Condition: Unknown
Due 29 April 2004
Resolved 14 May 2004
Operations/Management › Drug and Alcohol Testing
Issued 29 April 2004 Resolved
Provide proof of training given to all employees and supervisors. Provide hotline telephone number. LEGACY COMPONENT DESC: EAP Training Requirements
Condition: Improper/Lack of Maintenance
Due 29 April 2004
Resolved 14 May 2004
Construction/Loadline › Hull › Hull Plating
Issued 28 May 2002 Resolved
Repair hull scratches/gouges on the port & stbd sides underneath the trailer boards prior to carrying passengers.
Action required: 705 - Other - as specified
Due 1 July 2002
Resolved 1 July 2002
Documentation
Issued 7 March 2001 Resolved
Provide and post stability letter in accordance with 46 CFR 176.306.
Condition: Unknown
Due 14 March 2001
Resolved 26 March 2001
Lifesaving
Issued 7 March 2001 Resolved
Replace hydrostatic release in accordance with 46 CFR 185.740.
Condition: Unknown
Due 14 March 2001
Resolved 26 March 2001
Electrical
Issued 7 March 2001 Resolved
Provide (1) additional portable light in accordance with 46 CFR 183.430.
Condition: Unknown
Due 14 March 2001
Resolved 26 March 2001
Documentation
Issued 28 April 1999 Resolved
Provide proof of valid FCC Safety Certificate.
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999
Documentation
Issued 28 April 1999 Resolved
Provide proof of valid FCC Station License.
Condition: Unknown
Due 28 April 1999
Resolved 28 April 1999

Casualty record · 1

28 December 2012Routine · role: Involved in a Marine Casualty · activity 4510380
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.