TAGGED FISH is a 1998 passenger vessel (inspected). The Coast Guard has recorded 42 inspections since 1998, most recently in October 2025, along with 52 deficiencies — 1 with no resolution recorded —.

Records from 1998 to 2025. Most recent: inspection, 8 October 2025.

Built
1998
Last inspected
8 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY3607
473342
Flag
UNITED STATES
367697520
Maury page id
psix-473342

Inspections, by type

…with no type recorded5
…past their stated due date1
Years with a record 25 calendar years (1998–2025)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.0 ft × 16.0 ft × 4.0 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCARMAN BOATS INC · MARION, MD, UNITED STATES · built 1998
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portHIGHLANDS, NJ
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 12 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI4324MMSI 367697520 · active · compulsorily equipped · granted 20 April 2026, expires 16 October 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 42

8 October 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8249039
7 October 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8015312
27 June 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7942178
29 August 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7775227
15 August 2023 Type not recorded
No type recorded · USCGC HAMMERHEAD (WPB 87302) · USCG Northeast District (CGD-NE) · Activity 7772124
8 July 2022 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7490832
29 June 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7490790
6 April 2021 Administrative Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7161909
24 June 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6986531
15 April 2020 Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6939567
18 July 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6753853
23 October 2018 Type not recorded
No type recorded · USCGC HAMMERHEAD (WPB 87302) · USCG Northeast District (CGD-NE) · Activity 6567645
9 July 2018 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6473475
2 April 2018 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6392364
20 April 2017 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6128731
5 April 2016 COI Inspection · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5847785
22 February 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5820709
22 January 2016 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5801724
26 June 2014 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4908097
10 February 2012 DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4242140
28 July 2011 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4097485
26 March 2009 DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3440651
13 March 2008 Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3165942
22 March 2007 Deficiency Check · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2892585
16 October 2006 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2798242
25 May 2006 Type not recorded
No type recorded · USCGC BELUGA (WPB 87325) · USCG Northeast District (CGD-NE) · Activity 2659512
13 April 2006 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2638491
30 March 2006 Type not recorded
No type recorded · USCGC SHEARWATER (WPB 87349) · USCG East District (CGD-E) · Activity 2617693
6 March 2006 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2597041
2 March 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2302873
2 March 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2331377
13 April 2004 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2043088
15 March 2004 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2024657
19 March 2003 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1760805
2 April 2002 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1493433
12 March 2002 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1486411
16 April 2001 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1376558
5 May 2000 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 818165
14 April 2000 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1379059
6 April 1999 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1375946
8 May 1998 Initial Certification · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1364972
3 May 1998 Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1464099

Deficiency record · 52

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 October 2025 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. Vessel’s visual alarms were not operational for the following spaces: Lazarette, Engine room, and Tank space. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2025
Resolved 15 October 2025
Resolution: All three high water alarms has been replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 October 2025 No resolution recorded
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible. Vessel’s paper charts were dated from 2018. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2025 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 October 2025 Resolved
The Rules concerning lights shall be complied with from sunset to sunrise. Port sidelight is not operational. Repair port sidelight prior to operating between sunset and sunrise. 33 CFR 83.20(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2025
Resolved 15 October 2025
Resolution: Recieved picture of newly installed port running light.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 August 2023 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. The water light attached to the life float had loose battery connections, upon further inspection the battery was not the appropriate type for the water light. Replace battery on the water light in accordance with manufacture instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2023
Resolved 22 September 2023
Resolution: Received objective evidence via photograhs that the batteries were replaced on both water lights
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 29 August 2023 Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter. All lights attached to the life jackets were not working. Replace defective lights on each life jacket required on the COI to the satisfaction of the attending marine inspector. Vessel is restricted to no more than 20 miles from a harbor of safe refuge.
Action required: 705 - Other - as specified
Resolved 22 September 2023
Resolution: Received objective evidence via photograph that the lights were replaced on each life jacket
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 29 August 2023 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places. Donning placards were not visible,place donning placard in a conspicuous place to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 September 2023
Resolved 22 September 2023
Resolution: Received objective evidence via photograph that the donning placard was placed in a conspicuous place
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 8 July 2022 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels who occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. Deckhands not enrolled in a DAPI Consortium.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 July 2022
Resolved 18 July 2022
Resolution: Operator sent proof of enrollement for deckhand. (see deficiencies documents tab for details)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 July 2022 Resolved
A pre-engineered fixed gas fire extinguishing system must have the following equipment at the operating station: a means to reset devices used to automatically shut down engines. Fireboy overide at operating station inoperable.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2022
Resolved 22 July 2022
Resolution: Attended vessel, verified proper installation
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 8 July 2022 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Hydrostatic release unit installed greater than two years prior.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2022
Resolved 18 July 2022
Resolution: Operator submitted photograph of and purchase reciept for hydrostatic release. (see deficiencies documents tab for details)
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 18 July 2019 Resolved
The portable fire extinguisher bracket is broken, located immediately outside the cabin on the starboard cabin bulkhead. Replace broken bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 August 2019
Resolution: Received photo of corrected deficiency. New brackets installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 July 2019 Resolved
Vessel did not provide annual DAPI report. Vessel must provide report (may be in the form a MIS report) showing number of individuals tested, number and type of chemcial tests and the number of positive results.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 August 2019
Resolution: Received copy of MIS report.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 9 July 2018 Resolved
The marine employer must provide means to conduct alcohol testing after a serious marine incident. Owner provided proof of purchase for alcohol testing strips. Deficiency cleared.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 July 2018
Resolved 9 July 2018
Resolution: Owner purchased alcohol testing strips in the presence of attending marine inspectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 July 2018 Resolved
Found bilge pumps in all spaces were replaced with non UL listed equipment. Replace all submersible electric bilge pumps as meeting the requirements in UL 1113. Owner provided proof of purchase of UL 1113 listed bilge pumps. However, inspectors shall witness proper operation of bilge pumps once installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 23 July 2018
Resolution: The bilge pumps were replaced with pumps meeting the UL1113 stamdards and installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 9 July 2018 Resolved
Found hatch leading to lazarette with corroded gasket compromising watertight integrity. A hatch exposed to the weather must be watertight. Repair/replace gasket to maintain watertight integrity of hatch.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 23 July 2018
Resolution: The damaged gasket has been replaced with a new watertight gasket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 July 2018 Resolved
A submersible electrical bilge pump may be used provided that a positive shut off valve is installed at the hull penetration. Vessel must provide a valve at each electrical submersible pump disharge penetration.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2018
Resolved 23 July 2018
Resolution: The vessel's Captain installed positive shut off valves at the hull penetration points of the bilge pump systems.
Electrical › Electric Generation Source (service) › Generator
Issued 26 June 2014 Resolved
Repair, replace or remove from service, generator.
Due 26 August 2014
Resolved 18 September 2014
Resolution: Attended vessel and cleared above deficiency.
Construction/Loadline › Structures › Manhole
Issued 26 June 2014 Resolved
Access to forepeak required, install access plate.
Due 26 June 2015
Resolved 18 June 2015
Resolution: Access plate installed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 10 February 2012 Resolved
PVC pipe penetrations from the E/R fwd. need to be made watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2012
Resolution: USCG Marine Inspector wittnessed proper repairs.
Engineering › Steering Gear System › Rudder
Issued 10 February 2012 Resolved
Strong rudder stop to be installed to prevent damage to steering system,
Action required: 705 - Other - as specified
Due 1 April 2012
Resolved 5 April 2012
Resolution: Attending USCG Marine Inspector wittnessed satisfactory rudder stop.
Communications › Audible Communications › Bell
Issued 10 February 2012 Resolved
Vessel needs a bell and mounting bracket of proper size inaccordenance with 33CFR86.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2012
Resolution: Atttending USCG Marine Inspector wittnessed satisfactory bell.
Stability › Unintentional Flooding › General
Issued 26 March 2009 Resolved
Install shut off valve at the thru-hull fitting of the bilge pump discharge.
Condition: Placed in Improper Service
Due 24 April 2009
Resolved 10 April 2009
Resolution: Shut off valve installed.
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 26 March 2009 Resolved
Place on board vessel updated 46 CFR Part 166 to 199.
Condition: Improper/Lack of Maintenance
Due 24 April 2009
Resolved 10 April 2009
Resolution: Publications installed onboard vessel.
Lifesaving › Hand Flares › Expired
Issued 26 March 2009 Resolved
Place onboard 3 red flares and 3 orange flares or as a substitute 6 red flares for signalling.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2009
Resolution: Flares procured and installed onboard vessel.
Lifesaving › Lifebuoys › Serviceable
Issued 26 March 2009 Resolved
Procure and place onboard a new life ring.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2009
Resolution: New lifering installed onboard.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 13 March 2008 Resolved
Engine box currently does not have structural fire protection on the inside cover of engine box. Vessel owner informed that he must place a fire retardant barrier on the inside of the engine box.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2008
Resolved 26 March 2008
Resolution: Vessel owner placed NFPA/USCG approved fire protection on the inside cover of engine box. Visually examined sat.
Lifesaving › Inflatable Liferafts › Servicing
Issued 13 March 2008 Resolved
Inflatable life raft currently has not been serviced and is past it's inspection date. Vessel owner informed that he must have an up-to-date servicing record of the life raft and/or remove from vessel
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2008
Resolved 26 March 2008
Resolution: Vessel owner removed life raft from vessel, due to life raft not have a current inspection date. Life raft needs to be serviced every year and hydrostatic release every five years. Both had expired. Vessel owner decided to remove life raft.
Engineering › Bilge Water Management System › Pump
Issued 13 March 2008 Resolved
Vessel currently has non- UL listed Rule 1500 bilge pumps. Vessel owner instructed to place 04 UL approved bilge pumps in vessel
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2008
Resolved 26 March 2008
Resolution: Vessel owner placed UL listed Rule 2000 bilge pumps on-board vessel.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 March 2007 Resolved
Show proper operation of ring buoy water light.
Due 27 March 2007
Resolved 27 March 2007
Resolution: Provided new battery, sat
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 22 March 2007 Resolved
Label all circuit bkrs in ac panal.
Due 27 April 2007
Resolved 27 March 2007
Resolution: labeled.
Engineering › Bilge Water Management System › Pump
Issued 22 March 2007 Resolved
Label all high water alarms and bilge pumpps.
Due 27 April 2007
Resolved 27 March 2007
Resolution: labeled.
Fire Fighting › Combustible Materials › Insulation
Issued 22 March 2007 Resolved
Provide CG approved structural fire protection in engine box.
Due 27 April 2007
Resolved 12 April 2007
Resolution: Purchased new SFP for engine box
Stability › Watertight Integrity › Coaming
Issued 22 March 2007 Resolved
Provide 6" coaming into cabin entry door
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 27 March 2007
Resolution: coaming installed
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 April 2005 Resolved
Show operation of high water alarm in 2nd compt.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2005
Resolved 12 April 2005
Resolution: operated properly.
Lifesaving › Buoyant Apparatus › Painter
Issued 11 April 2005 Resolved
Provide new 100' painter.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2005
Resolved 12 April 2005
Resolution: New painter installed.
Engineering › Bilge Water Management System › Pump
Issued 3 March 2005 Resolved
Show operation of bilge pump auto switch in 2nd compt.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2005
Resolved 27 September 2005
Resolution: operating sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 3 March 2005 Resolved
Show proof of service for all portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2005
Resolved 27 September 2005
Resolution: All fe''s serviced.
Lifesaving › Buoyant Apparatus › Painter
Issued 3 March 2005 Resolved
Renew 100' painter for life float.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2005
Resolved 27 September 2005
Resolution: New painter installed.
Lifesaving › Buoyant Apparatus › Float Free
Issued 3 March 2005 Resolved
Replace rotten paddle with a servicable one.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2005
Resolved 20 September 2005
Resolution: paddle replaced.
Lifesaving › Buoyant Apparatus › Capacity
Issued 2 March 2005 Resolved
Provide new 4' paddle.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2005
Resolved 12 April 2005
Resolution: Purchased new paddle.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 2 March 2005 Resolved
Show proof of service for all portable FE's.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2005
Resolved 12 April 2005
Resolution: serviced.
Personnel › Training › First Aid/CPR
Issued 19 March 2003 Resolved
RENEW RED CROSS FIRST AID/CPR CERTIFICATION.
Action required: 705 - Other - as specified
Due 19 April 2003
Resolved 20 August 2004
Engineering › Bilge Water Management System
Issued 12 March 2002 Resolved
LABEL HIGH WATER ALARMS AT OPERATING STATION.
Due 12 April 2002
Resolved 15 March 2002
Lifesaving
Issued 16 April 2001 Resolved
LABEL PFD STORAGE IN FWD COMPARTMENT.
Condition: Unknown
Due 16 May 2001
Resolved 15 May 2001
Engineering
Issued 16 April 2001 Resolved
REPAIR OIL AND WATER AUDIBLE ALARM ON STBD ENGINE.
Condition: Unknown
Due 16 May 2001
Resolved 15 May 2001
Lifesaving
Issued 14 April 2000 Resolved
TIE LIFE FLOAT PENNITS.
Condition: Unknown
Due 7 May 2000
Resolved 4 May 2000
Engineering
Issued 14 April 2000 Resolved
DOUBLE CLAMP ALL EXHAUST CONNECTIONS.
Condition: Unknown
Due 7 May 2000
Resolved 4 May 2000
Electrical
Issued 14 April 2000 Resolved
HANGER CABLES IN ENG COMP WITH METALIC HANGERS.
Condition: Unknown
Due 7 May 2000
Resolved 4 May 2000
Lifesaving
Issued 14 April 2000 Resolved
REPAIR LIFE FLOAT WATER LIGHT.
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Lifesaving
Issued 14 April 2000 Resolved
PROVIDE SPRING CLIP ON RING BUOY WATER LIGHT.
Condition: Unknown
Due 7 May 2000
Resolved 4 May 2000
Construction/Loadline
Issued 14 April 2000 Resolved
PROVIDE COAST GUARD APPROVED HOSES ON THRU HULL VALVES.
Condition: Unknown
Due 7 May 2000
Resolved 4 May 2000
Engineering
Issued 14 April 2000 Resolved
PROVIDE GROUND WIRE ON FUEL FILL TO TANK.
Condition: Unknown
Due 7 May 2000
Resolved 4 May 2000
Lifesaving
Issued 14 April 2000 Resolved
PROVIDE 2 PADDELS ON LIFE FLOATS.
Condition: Unknown
Due 7 May 2000
Resolved 4 May 2000