OSPREY is a 1972 passenger vessel (inspected). The Coast Guard has recorded 75 inspections since 1982, most recently in October 2025, along with 92 deficiencies.

Records from 1982 to 2025. Most recent: inspection, 29 October 2025.

Built
1972
Last inspected
29 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM3791
Flag
UNITED STATES
338576000
Maury page id
psix-47338

Inspections, by type

…with no type recorded16
Years with a record 41 calendar years (1982–2025)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)75.0 ft × 21.7 ft × 6.9 ft
Registered tonnagegross 81 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1972
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFRIDAY HARBOR, WA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it55 - Regulatory (Subpart C or D), Net Ton
81 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM3791MMSI 338576000 · active · compulsorily equipped · granted 21 May 2021, expires 21 May 2031
WDH2774MMSI 338576000 · cancelled · compulsorily equipped · granted 8 January 2014, cancelled 17 May 2021 · licensed under a name not among this hull’s recorded names (not shown)
WL8825MMSI 366920190 · expired · compulsorily equipped · granted 16 January 2004, cancelled 12 April 2014 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 75

29 October 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8260468
7 October 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8244481
23 September 2024 Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8008166
12 October 2023 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7806082
6 October 2023 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7803846
16 November 2022 Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7596023
14 March 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7416641
16 February 2022 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7397580
29 November 2021 Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7360688
25 October 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7339384
2 November 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7088196
19 November 2019 Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6857699
17 November 2019 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6856974
16 October 2018 COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6561640
22 March 2018 Internal Structural Exam · DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6374858
23 October 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6293191
8 March 2017 Administrative Inspection · DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6100062
8 March 2016 Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5828779
27 October 2015 Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5756830
10 March 2014 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4797357
2 July 2012 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4364202
27 June 2012 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4358107
11 May 2009 Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3472610
24 March 2008 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3170603
10 April 2007 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3053353
20 March 2006 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2606118
1 June 2005 Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2375478
4 May 2004 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2056138
29 January 2004 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1996827
26 March 2003 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1763131
14 January 2003 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1730327
29 April 2002 Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1736955
16 March 2001 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1471038
9 March 2001 Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 1521658
4 March 2001 Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 1521654
2 February 2001 Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 1521645
30 January 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1064606
24 January 2001 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1422100
26 January 2000 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1361337
24 June 1999 Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 1509929
26 January 1999 Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1418460
12 February 1998 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1470933
28 January 1997 COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1435854
11 March 1996 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1083977
29 January 1996 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1452105
26 May 1995 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1442354
16 February 1995 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1470673
6 February 1995 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 855670
23 April 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 857886
15 February 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1163604
14 January 1994 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 852292
21 August 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 20116
1 February 1993 Inclining Experiment · COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357983
2 April 1992 Re-Inspection · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1263304
2 April 1991 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 914574
27 February 1991 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1212571
30 August 1990 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 917346
6 March 1990 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 899443
15 February 1990 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1215651
8 March 1989 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 891984
6 May 1988 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1198820
22 April 1988 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1034295
23 February 1988 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1336424
23 June 1987 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1314572
13 May 1987 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1028595
28 January 1987 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1011136
2 April 1986 Excursion Permit
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 998742
26 February 1986 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1304774
18 September 1985 Credit Drydock
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1302466
26 February 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 980108
11 April 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 973611
8 March 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1280799
5 April 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1275211
5 March 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1275527
8 February 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1275164

Deficiency record · 92

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 October 2025 Resolved
THE EQUIPMENT REQUIRED FOR LIFE FLOATS AND BUOYANT APPARATUS MUST MEET THE FOLLOWING SPECIFICATIONS:...THE LIGHT MUST BE A FLOATING WATER LIGHT APPROVED UNDER APPROVAL SERIES 161.010 OR OTHER STANDARD SPECIFIED BY THE COMMANDANT...THE STARBOARD MOST FLOATING WATER LIGHT FOR A LIFE FLOAT WAS UV DETERIORATED MISSING A PORTION OF THE SEALING AREA.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2025
Resolved 18 October 2025
Resolution: Light was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2025 Resolved
EACH DISTRIBUTION PANEL OR SWITCHBOARD MUST BE TOTALLY ENCLOSED AND OF THE DEAD FRONT TYPE. SWITCHBOARD IN ENGINE ROOM HAD 01 BLANKING PLATE MISSING AND 05 OPENINGS FROM 04 CUT WIRES ON THE BOTTOM AND 01 OPENING ON THE FORWARD SIDE OF THE SWITCHBOARD PANEL. Correct Prior to Credit Drydock
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2025
Resolved 29 October 2025
Resolution: Crew safely removed cut wires and covered openings in distribution panel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 October 2025 Resolved
ALL CABLE AND WIRE MUST: HAVE STRANDED COPPER CONDUCTORS WITH SUFFICIENT CURRENT CARRYING CAPACITY FOR THE CIRCUIT IN WHICH THEY ARE USED. THERE WAS A YELLOW, SOLID CORE HOUSEHOLD WIRE INSTALLED FOR USE OF THE SEWAGE PUMP. THE CIRCUIT FOR THIS IS REQUIRED TO BE SECURED INOPERABLE UNTIL REPLACED WITH MARINE GRADE STRANDED WIRE. Correct Prior to Credit Drydock
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 December 2025
Resolved 29 October 2025
Resolution: Crew replaced solid core wire to sewage pump with marine grade wire.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 October 2023 Resolved
Cables entering boxes or fittings shall be protected from abrasion; the cable armor shall be secured to the box. Inspector observed overhead mounted junction box with cable entering knockout not secured. Worklist item, completed during current drydock. Old T 46CFR183.10-20(f)(2)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 9 October 2023
Resolution: Rcvd photo of new installation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 November 2022 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, or injury. A valve on the fuel tank does not have a closing device and creates a fire risk.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 5 December 2022
Resolution: Operator capped the fuel valve.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 November 2022 Resolved
Each battery must be secured to protect from exposure to water splash or spray. There is liquid in the battery tray, which could be water or acid. Remove liquid from battery tray.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 5 December 2022
Resolution: Liquid was removed from battery boxes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 November 2022 Resolved
Penetrations of required watertight bulkheads must be accomplished using an acceptable metallic through bulkhead fitting and one or more shutoff valves must be installed adjacent to the fitting. There are through hull penetrations for nonmetallic hose that do not have shutoff valves.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 5 December 2022
Resolution: Deficiency was written in error.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Investigation after accident
Issued 16 November 2022 Resolved
Alcohol testing must be completed within two hours of a serious marine incident. The vessel does not have a means of alcohol testing within two hours.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 5 December 2022
Resolution: Alcohol swabs were ordered and placed on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 16 November 2022 Resolved
The vessel's hydrostatic release was improperly installed. Corrected on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 16 November 2022
Resolved 16 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 16 November 2022 Resolved
The vessel's life float was not installed in a float free arrangement. Corrected on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 16 November 2022
Resolved 16 November 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 November 2021 Resolved
MI found that watertight bulkhead penetrations were not watertight. Make penetrations and openings in all watertight bulkheads watertight and prove the same. cite: 46CFR171.114
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 December 2021
Resolution: MI observed watertight penetrations plugged and made watertight.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 29 November 2021 Resolved
Found 4 inch fracture of weld in way of generator exhaust on bulkhead forward in steering gear room. provide repair plan to address fracture in way of WTB between steering gear room and ER. cite: 46CFR177.10-1
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 December 2021
Resolution: Vessel operator conducted NDT, had welder repair the weld, and conducted NDT to prove that weld repair was sound.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 November 2021 Resolved
Reduction gear oil hose on stbd engine leaking. Replace hose with hose that meets SAEJ1942 standards and provide proof to sector puget sound.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2021
Resolution: Operator provided proof that hose installed was Parker 387TC-16 which is listed on SAE-J1942 approved list.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 November 2021 Resolved
Life line on ring buoy on main deck found dry-rotted. Replace lifeline on ring buoy. Cite: 46CFR180.70(c)
Action required: 705 - Other - as specified
Resolved 16 February 2022
Resolution: Received photograph showing new lifeline installed on ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 November 2021 Resolved
Lifering buoy on upper deck not marked with vessel name or CG approval number. Prove the ring buoy meets Subchapter Q standards or replace with ring buoy that meets Q standards. 46CFR180.70(b)(1) 46CFR185.604(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2021
Resolution: Vessel operator provided photograph showing new life ring buoy installed on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 November 2021 Resolved
IBA onboard has not been serviced by date on servicing sticker. Have IBA serviced by approved LR servicing facility and provide proof. Vessel restricted to LBS route until IBA is serviced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2021
Resolved 16 December 2021
Resolution: Operator provided photograph of new IBA installed on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 29 November 2021 Resolved
Life float paddles onboard marked with previous vessel name and not lashed properly. Life float paddles must be lashed to life float it belongs to and marked with vessel name. 46CFR180.175(f)(2) 46CFR185.604(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2021
Resolved 6 December 2021
Resolution: Operator provided photographs showing vessel's name and paddles properly lashed to life float.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 November 2021 Resolved
Each door in a deckhouse that give access into the hull must be fitted with permanent watertight coaming. 2 of 3 weathertight deckhouse doors have been modified with holes. Make each coaming watertight. Cite: 46CFR171.124(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2021
Resolved 20 December 2021
Resolution: Operator provided proof that coaming was made watertight.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 November 2021 Resolved
FCC Bridge to Bridge & Safety Radiotelephony Certificate onboard had previous vessel name and call sign. Provide proof of updated FCC Certificates. Cite: 47CFR80.1005
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2021
Resolved 11 January 2022
Resolution: Operator provided proof of corrected FCC Certificates and have placed them onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 November 2021 Resolved
An adult lifejackets must be provided for each person carried on board a vessel. Vessel did not have 129 lifejackets on board. Provide proof that vessel has 129 life jackets onboard. 46CFR180.71
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2021
Resolution: Vessel operator provided proof that 129 adult life jackets were onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 November 2021 Resolved
Life jacket stowage location not marked with correct # of life jackets. Mark stowage with correct # of life jackets stowed inside and provide proof.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2021
Resolved 10 December 2021
Resolution: Vessel operator provided proof that life jackets stowed in upper deck location matched life jacket stowage marking.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 29 November 2021 Resolved
Single side band radio not operating. Provide proof that SSB is properly operating. Vessel restricted to Coastwise route until proof received. 47CFR80.905(3)(iii)(A)
Action required: 705 - Other - as specified
Resolved 23 September 2024
Resolution: Witnessed satisfactory operational test of SSB.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 November 2021 Resolved
Non-metallic sewage pipes did not have two valves installed. Provide plan to our office to install 2nd valve on steering gear room side. 46CFR182.40-1(a)(1)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2021
Resolved 24 February 2022
Resolution: Operator provided photographs showing installed metallic valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 November 2021 Resolved
Corrosion & possible exhaust leak at exhaust pipe from stbd engine. Prove airtightness of exhaust pipe in steering gear room. 46CFR177.114
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 December 2021
Resolution: Witnessed operational testing of stbd engine to include exhaust, no leak observed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 16 October 2018 Resolved
03102/46 CFR 185.602(c)/17c - Each vessel must have permanent draft marks at each end of the vessel; or have permanent loading marks placed on each side of the vessel forward and aft to indicate the maximum allowable trim and amidships to indicate the maximum allowable draft. Vessel did not have forward draft or loading marks and aft draft marks exist only to 4 feet. Prior to the carriage of passengers, operator must affix temporary draft marks to permit maximum draft measurements as specified on the vessel's stability letter. Permanent draft marks will be accepted at vessel's next scheduled dry dock.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 November 2018
Resolved 6 November 2018
Resolution: Reeceived photograph evidence of temporary draft marks affixed in accordance with current stability letter.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 October 2018 Resolved
10109/33 CFR 83.21(c)/33 CFR 84.16(a)(i)/50c - A sternlight shall be placed as nearly as practicable at the stern and shall ensure that the required minimum intensity is maintained at all angles from 5 degrees above to 5 degrees below the horizontal. The current sternlight visibility below horizontal is restricted due to the aft extent of the vessel's canopy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2018
Resolved 8 November 2018
Resolution: Vessl representative provided photograph evidence of stern light relocation enabling visibility 5 degrees below horizontal.
Construction/Loadline › Structures › Deck Plating
Issued 27 October 2015 Resolved
Vessel to provide plans for repair of corrosion in the #3 void, including keel, transverse frames 1-4, and longitudinals in lazarette.
Action required: 705 - Other - as specified
Due 30 November 2015
Resolved 3 November 2015
Resolution: Operator provided plans to crop and renew the CVK, transvers frames, and lazarette longitudinals.
Documentation › Certificates/Documents › Stability Letter
Issued 2 July 2012 Resolved
Provide the stability letter.
Action required: 705 - Other - as specified
Resolved 25 July 2012
Resolution: Faxed copy received & scanned to MISLE.
Communications › Radio Communications › EPIRB
Issued 2 July 2012 Resolved
Provide EPIRB & proof of registration with NOAA.
Action required: 705 - Other - as specified
Resolved 25 July 2012
Resolution: Received fax copy of NOAA registration. Made data entry to MISLE>
Engineering › Bilge Water Management System › Pump
Issued 27 June 2012 Resolved
Crop and renew bilge pump base located in Pump Room. Currently the base is wasted .
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2012
Resolved 2 July 2012
Resolution: Base has been renewed to the satisfaction of the attending MI.
Engineering › Bilge Water Management System › Pump
Issued 27 June 2012 Resolved
Crop and Renew bilge pump #2 base in Pump Room. Currently base is wasted beyond repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2012
Resolved 2 July 2012
Resolution: Base has been renewed to the satisfaction of the attending MI.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 June 2012 Resolved
Install approved cover on Air Condition compressor controller located Stbd Side of pump room.
Due 28 July 2012
Resolved 2 July 2012
Resolution: Cover installed.
Accommodation/Occupational Safety › Ventilation › General
Issued 27 June 2012 Resolved
Repair/Replace or Remove fan motor located portside Pump Room. Fan housing is severely rusted.
Due 27 July 2012
Resolved 2 July 2012
Resolution: Fan motor removed from service.
Construction/Loadline › Structures › Deck Plating
Issued 27 June 2012 Resolved
Repair hole in over head located in steering compartment stbd side amid ship.
Action required: 705 - Other - as specified
Due 27 July 2012
Resolved 2 July 2012
Resolution: Hole has been repaired.
Construction/Loadline › Penetrations › Pipe Flange
Issued 27 June 2012 Resolved
Install clamp on STBD Exhaust muffler in rudder compartment.
Due 27 July 2012
Resolved 2 July 2012
Resolution: Clamp installed.
Engineering › Steering Gear System › Bracket/Clamp
Issued 27 June 2012 Resolved
Inspect PPP port steering bracket. Report if beyond service.
Due 27 July 2012
Resolved 2 July 2012
Resolution: Completed sat
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 11 May 2009 Resolved
Provide or renew retroreflective material on lifejackets where tape was deteriorated. Vessel is limited to 42 adults and 10 children until complete.
Action required: 705 - Other - as specified
Due 11 June 2009
Resolved 4 June 2009
Resolution: Retro provided.
Stability › Watertight Integrity › General
Issued 11 May 2009 Resolved
Survey and repair water tight bulkhead penetrations throughout the vessel as necessary.
Action required: 705 - Other - as specified
Due 11 June 2009
Resolved 30 June 2009
Fire Fighting › Fire Pumps › Pressure
Issued 11 May 2009 Resolved
Provide proper operation of fire pump prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2009
Personnel › Certificates/Documents/Licenses › License, Master
Issued 11 May 2009 Resolved
Provide licensed Master and conduct emergency drills.
Action required: 705 - Other - as specified
Due 23 May 2009
Resolved 4 June 2009
Resolution: Provided.
Documentation › Certificates/Documents › FCC SSL
Issued 11 May 2009 Resolved
Provide FCC safety certificate.
Action required: 705 - Other - as specified
Due 22 May 2009
Resolved 2 June 2009
Stability › Watertight Integrity › General
Issued 24 March 2008 Resolved
Make FWD bulkhead of engine room water tight.
Action required: 705 - Other - as specified
Due 3 April 2008
Resolved 25 March 2008
Resolution: Replaced rubber grommets in bulkhead.
Engineering › Fuel Oil Service System › Filter
Issued 24 March 2008 Resolved
Repair/Replace fuel filter drip bowl on STBD MDE.
Action required: 705 - Other - as specified
Due 3 April 2008
Resolved 25 March 2008
Resolution: Replaced Bowl.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 March 2008 Resolved
Repair/Replace port running light
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2008
Resolved 25 March 2008
Resolution: Repaired port running light.
Communications › Radio Communications › EPIRB
Issued 24 March 2008 Resolved
Install EPIRB in a float free location.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2008
Resolved 25 March 2008
Resolution: Installed EPIRB on mast in a float free location.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 24 March 2008 Resolved
Repair/Replace bilge alarm in crew quarters.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2008
Resolved 25 March 2008
Resolution: Replaced bilge sensor.
Navigation › Piloting/Steering › Marine Charts
Issued 24 March 2008 Resolved
Provide updated charts of local operating area.
Action required: 705 - Other - as specified
Due 3 April 2008
Resolved 25 March 2008
Resolution: Provide charts
Lifesaving › Visual Distress Signals (General) › Marking
Issued 26 March 2003 Resolved
Label all watertight lights IWO lifefloats and liferings within 30 days.
Due 26 April 2003
Resolved 26 March 2003
Resolution: Completed prior to inspectors departure.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 March 2003 Resolved
Properly attach new reflective tape IWO lifejackets and liferings within 30 days.
Due 26 April 2003
Resolved 26 March 2003
Resolution: Completed prior to inspectors departure.
Electrical › Electric Generation Source (service)
Issued 26 March 2003 Resolved
Install wire ties IWO engineroom within 30 days.
Due 26 April 2003
Resolved 28 March 2003
Stability › Watertight Integrity
Issued 26 March 2003 Resolved
Make permanent repairs to watertight doors IWO pilothouse, fix lower dogs within 7 days. LEGACY COMPONENT DESC: Doors
Due 2 April 2003
Resolved 28 March 2003
Navigation › Piloting/Steering › Compass Deviation Table
Issued 29 April 2002 Resolved
RENEW COMPASS DEVIATION CARD.
Due 29 May 2002
Resolved 15 January 2003
Construction/Loadline › Hull › Weld
Issued 29 April 2002 Resolved
RENEW THREE FRACTURED WELDS IN FOREPEAK.
Due 29 May 2002
Resolved 15 January 2003
Engineering › Bilge Water Management System › Valve
Issued 29 April 2002 Resolved
REPAIR FOREPEAK COLLISION BULKHEAD BILGE SUCTION VALVE REACH ROD.
Due 29 May 2002
Resolved 15 January 2003
Construction/Loadline › Structures › Door
Issued 29 April 2002 Resolved
ARREST AND RE-WELD FRACTURES IN WAY OF ALL CORNERS OF ALL MAIN DECK EXTERIOR DOORS.
Due 29 May 2002
Resolved 15 January 2003
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 April 2002 Resolved
LAG OR PROVIDE OTHER PERSONNEL GUARD ON GENERATOR HOT EXHAUST PIPING IN LAZERETTE.
Due 29 May 2002
Resolved 15 January 2003
Navigation › Piloting/Steering › Marine Charts
Issued 29 April 2002 Resolved
PROVIDE ON BOARD CURRENT NAVIGATIONSL CHART.
Due 29 May 2002
Resolved 15 January 2003
Lifesaving
Issued 16 March 2001 Resolved
EXPIRED FIRST AID KIT ITEMS (ASPRIN, EYE WASH) TO BE RENEWED.
Condition: Unknown
Due 15 May 2001
Resolved 17 May 2001
Construction/Loadline
Issued 16 March 2001 Resolved
PROVIDE MEANS TO SECURE DECK HOUSE SCUPPERS / DRAINAGE CUT OUTS WHILE UNDERWAY.
Condition: Unknown
Due 15 May 2001
Resolved 17 May 2001
Fire Fighting
Issued 16 March 2001 Resolved
ATTACH SPANNERS TO FIRE HYDRANTS.
Condition: Unknown
Due 15 May 2001
Resolved 17 May 2001
Lifesaving
Issued 16 March 2001 Resolved
PROVIDE ADDITIONAL MARKED LIFEJACKET STOWAGE TO RELFLECT NEW AUTHORIZED PASSENGER COUNT.
Condition: Unknown
Due 15 May 2001
Resolved 17 May 2001
Lifesaving
Issued 16 March 2001 Resolved
DOUBLE UP U-BOLT CLAMPS ON RESCUE PLATFORM WIRE CABLES.
Condition: Unknown
Due 15 May 2001
Resolved 17 May 2001
Fire Fighting
Issued 26 January 2000 Resolved
CROP AND RENEW FIRE MAIN PIPING IWO FIREPUMP.
Condition: Unknown
Due 26 February 2000
Resolved 1 March 2000
Construction/Loadline
Issued 26 January 2000 Resolved
PROVE PROPER OPERATION OF AUDIBLE BILGE ALARMS.
Condition: Unknown
Due 26 February 2000
Resolved 1 March 2000
Lifesaving
Issued 26 January 2000 Resolved
PROVIDE CURRENT TRAINING LOGBOOK IAW 46 CFR 185.420.
Condition: Unknown
Due 26 February 2000
Resolved 1 March 2000
Electrical
Issued 26 January 2000 Resolved
INSTALL LATCH ON PORT POWER PANEL IWO ENGINEROOM.
Condition: Unknown
Due 26 February 2000
Resolved 1 March 2000
Electrical
Issued 26 January 2000 Resolved
INSTALL PROTECTIVE MATTING IWO GENERATOR POWER PANEL.
Condition: Unknown
Due 26 February 2000
Resolved 1 March 2000
Lifesaving
Issued 26 January 2000 Resolved
CONDUCT MAN OVERBOARD DRILL IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 26 February 2000
Resolved 1 March 2000
Accommodation/Occupational Safety
Issued 29 January 1996 Resolved
MAKE PERMANENT REPAIR TO LEAKING WATER SUPPLY PIPE, STARBOARD HEAD.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Navigation
Issued 29 January 1996 Resolved
RENEW WASTED PIPING AND HOSES WITH CORROSION ON FITTINGS FOR STEERING SYSTEM.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Construction/Loadline
Issued 29 January 1996 Resolved
SEAL WIRE (PORTSIDE) AND PIPE (STBD) GOING THRU FORWARD BULKHEAD IN RUDDER ROOM.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Electrical
Issued 16 February 1995 Resolved
INSTALL LIGHT COVERS.
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Construction/Loadline
Issued 16 February 1995 Resolved
INSTALL METAL VALVE AND NIPPLE WERE PVC PIPE GOES THROUGH W/T BULKHEAD FOR MSD. 46CFR182.40
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Navigation
Issued 16 February 1995 Resolved
PLACE ONBOARD LIGHT LIST, CURRENT AND TIDE TABLES.
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Electrical
Issued 16 February 1995 Resolved
INSTALL MARINE CONNECTORS ON BILGE PUMP WIRES.
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Electrical
Issued 16 February 1995 Resolved
REMOVE DEAD END WIRES IN TANK ROOM.
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Construction/Loadline
Issued 15 February 1994 Resolved
SUBMIT PLANS FOR APPROVAL TO [name withheld] PRIOR TO 15MAR94.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Construction/Loadline
Issued 15 February 1994 Resolved
AT NEXT DRYDOCK REMOVE WATERTIGHT DOOR IN TRANSVERSE BULKHEAD, FRAME 9, AFTOF CREW BERTHING AND MAKE WATERTIGHT.
Condition: Unknown
Due 15 February 1994
Resolved 15 February 1994
Electrical
Issued 2 April 1992 Resolved
INSALL BLANK AND NUMBER/ LABEL BREAKERS IN CLEANING ROOM ELECTRICAL PANEL.
Condition: Unknown
Due 24 April 1992
Resolved 24 April 1992
Electrical
Issued 2 April 1992 Resolved
INSTALL GROMENT IN PRESSURE SWITCH FOR WASH DOWN TANK.
Condition: Unknown
Due 24 April 1992
Resolved 24 April 1992
Electrical
Issued 2 April 1992 Resolved
INSTALL JUCTION BOX FOR A.C. UNIT WIRES.
Condition: Unknown
Due 24 April 1992
Resolved 24 April 1992
Deck/Cargo
Issued 2 April 1992 Resolved
REMOVE 4 FOOT OF ANCHOR LINE WHERE IT CONNECTS TO ANCHOR DUE TO WEAR.
Condition: Unknown
Due 24 April 1992
Resolved 24 April 1992
Navigation
Issued 27 February 1991 Resolved
RENEW EPIRB BATTERY.
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Engineering
Issued 27 February 1991 Resolved
REPAIR LEAK IN GENERATOR EXHAUST PIPE LOCATED IN AFT STEERING COMPARTMENT.
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Documentation
Issued 27 February 1991 Resolved
OBTAIN VALID RADIO OPERATORS LICENSE.
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Navigation
Issued 27 February 1991 Resolved
OBTAIN UPDATED NAV-SAFETY PUBLICATIONS, IE. COAST PILOT, TIDE TABLES,.
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Construction/Loadline
Issued 13 May 1987 Resolved
REBUILD DOGS ON WATERTIGHT DOOR AT FORWARD TANK COMPARTMENT.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Lifesaving
Issued 13 May 1987 Resolved
LABEL TWO RING BOUYS.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Navigation
Issued 26 February 1985 Resolved
OBTAIN ADDITIONAL DAY SHAPE
Condition: Unknown
Due 26 February 1985
Resolved 26 February 1985
Navigation
Issued 26 February 1985 Resolved
OBTAIN NOT UNDER COMMAND LIGHTS RED OVER RED.
Condition: Unknown
Due 26 February 1985
Resolved 26 February 1985
Lifesaving
Issued 26 February 1985 Resolved
ATTACH FLOAT FREE LINK TO VESSEL AS IN ACCORDANCE WITH 46 CFR 180.20-1(A).
Condition: Unknown
Due 26 February 1985
Resolved 26 February 1985
Navigation
Issued 26 February 1985 Resolved
REPLACE LAMP TO BOW LIGHT.
Condition: Unknown
Due 26 February 1985
Resolved 26 February 1985

Ownership record