Inspection history · 95
5 June 2026
Re-Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8392639
5 March 2026
COI Inspection · Vessel Attendance
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8312394
9 December 2025
Re-Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8280152
2 September 2025
Deficiency Check · Internal Structural Exam · Drydock Exam · Vessel Attendance
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8219069
31 August 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8225639
15 May 2025
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8130338
21 February 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8082668
17 January 2025
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8072594
16 September 2024
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8003706
20 June 2024
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7943922
12 May 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7910927
9 May 2024
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7905607
25 April 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7901885
25 April 2024
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7902115
24 April 2024
Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 7975723
2 April 2024
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7889021
30 January 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7857860
30 January 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7858595
6 January 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7845899
3 November 2023
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7821145
13 September 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7791238
24 May 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7695600
24 May 2023
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7695735
18 April 2023
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7671674
21 March 2023
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7654320
12 December 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7607951
8 November 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7591750
10 October 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7574717
13 September 2022
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7559022
19 August 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7538233
1 August 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7522524
10 July 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7503492
27 June 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7489312
19 May 2022
COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7445613
15 April 2022
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7431909
3 April 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7424615
2 February 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7389501
22 December 2021
Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7371679
18 November 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7353724
20 September 2021
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7318875
3 August 2021
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7276672
24 June 2021
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7232159
15 June 2021
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7226378
18 May 2021
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7201496
30 March 2021
Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7162948
17 January 2021
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7148752
13 November 2020
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7101587
13 November 2020
Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7101654
9 October 2020
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7141403
18 September 2020
Internal Structural Exam · Examination of Repairs · Drydock Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7054715
29 June 2020
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6990883
2 June 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6966710
27 January 2020
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6897932
29 December 2019
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6880647
17 December 2019
Re-Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6875791
7 December 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6872525
29 October 2019
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6873428
14 October 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6852448
19 September 2019
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6816179
16 September 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6813060
26 August 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6795393
5 June 2019
Deficiency Check · COI Inspection · MTSA Verification · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6704459
28 May 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6710938
29 April 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6703424
22 April 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6667967
26 March 2019
MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6649421
9 March 2019
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6712050
2 January 2019
Re-Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6604761
3 October 2018
Security Breach, Potential · Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6569112
24 September 2018
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6547615
24 September 2018
Re-Inspection · Security Plan Review - ASP
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6547814
14 September 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6545792
19 August 2018
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6518094
19 August 2018
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6527502
12 June 2018
COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6442694
4 June 2018
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6533287
16 April 2018
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6436753
29 March 2018
Security Breach, Potential · Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6381254
16 March 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6373223
5 February 2018
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6349876
22 November 2017
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6373366
10 October 2017
MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6285084
13 July 2017
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6208341
20 April 2017
In-Service Inspection · MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6129568
12 January 2017
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6066536
15 December 2016
Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6058034
28 October 2016
Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6031523
26 July 2016
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5955053
1 July 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5931439
3 June 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5896697
3 June 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5995386
18 April 2016
Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5863350
3 April 2016
Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5846692
1 March 2016
COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5825060
19 January 2016
Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5801005
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 December 2025
Resolved
Oil hoses leading to and from the PT pump on the No. 1 Cummins Diesel Generator are not fire rated. Provide fire sleeve with band clamps or renew hose with material listed as fire rated in SAE J1942.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2026
Resolved 14 July 2026
Resolution: Hoses replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 November 2025
Resolved
Aux steam boilers are only equipped with one low water cut off device. ASME/ANSI CSD-1 (incorporated by reference) requires two such devices. Install a second low water cut off device in accordance with all code requirements by 19JAN2026.
46 cfr 63.05-40 (Ca.1970)
Action required: 705 - Other - as specified
Due 19 January 2026
Resolved 9 June 2026
Resolution: Redundant control installed and tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2025
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Self-igniting lights on 02 lifebouys- number 2 end forward of pilot house, were not able to be activated due to battery source needing replacement.
46CFR199.190(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 May 2025
Resolved 15 May 2025
Resolution: Crew replaced batteries in 02 self igniting lights, tested. All Sat
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 May 2025
Resolved
Lifejackets must be stowed as follows: The lifejackets must be readily accessible. During testing of the life jacket drop bin on the number 1 end, starboard side, the release mechanism failed to release stowed lifejackets making them inaccessible.
46CFR199.70(b)(2)(i)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 May 2025
Resolved 15 May 2025
Resolution: Crew preformed maintenance on the lifejacket bin storage unit. Conducted drop test. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 September 2024
Resolved
Electrical wire must be in an enclosure. Flexible conduit has separated from the junction box on the #2 ships boiler blower motor. Examine wires for damage and restore conduit connection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2024
Resolved 17 September 2024
Resolution: Received photos of item correction.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 September 2024
Resolved
In all ventilation systems, manually operated dampers or other suitable means shall be provided for shutting off the passage of air in the event of fire.
Vent closure for #1 steering gear space on starboard side unable to close.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2024
Resolved 17 September 2024
Resolution: Received photos of corrected item.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 May 2024
Resolved
Auxiliary machinery vital to the main propulsion system must be provided in duplicate unless the system served is provided in independent duplicate, or otherwise provides continued or restored propulsion capability in the event of a failure or malfunction of any single auxiliary component. One of the shaft thrust bearing oil pumps on #1 end is inoperable.
46 CFR 58.01-35
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 May 2024
Resolved 13 May 2024
Resolution: Received statement from Chief Engineer [name withheld], stating the #1 pump had been repaired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 May 2024
Resolved
The system shall be so designed and arranged that the overhead is effectively sprayed and all
portions of the deck are covered. Car deck sprinkler failed due to 08 sprinkler heads being clogged. Vessel is required to conduct quarterly sprinkler tests and provide reports to Sector Puget Sound.
46CFR76.23-10(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2024
Resolved 17 January 2025
Resolution: Defective heads had been replaced and vessel enrolled in quarterly sprinkler tests.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 May 2024
Resolved
Where extinguishing systems or equipment are not required, but are installed, the system or equipment
and its installation must meet the requirements of this part. Smoke detectors were removed from Porters SR, 2nd [name withheld], [name withheld], and Asst. Eng SR but detector mounts were still on the wall.
46CFR76.01-5(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 May 2024
Resolved 9 May 2024
Resolution: Detectors installed in all four crew berthing rooms missing them.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 May 2024
Resolved
Test and inspections of automatically fired auxiliary boilers are to include draft limit controls in case of loss of air pressure. Both auxiliary boilers have inoperative draft switches. Renew draft switches and demonstrate proper operation to the attending Marine Inspector.
46 CFR 61.35-3(a)(7)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2024
Resolved 9 September 2024
Resolution: Draft stop for both Aux boilers working with audible and visible alarms locally and in ECR.
12 - Dangerous Goods › N/A - No Subsystem › Personal protection
Issued 9 May 2024
Resolved
Fire tube boilers of less than 150psi shall be equipped with safety relief valves which shall be tested annually. The safety valve on the #1 boiler failed to reseat after testing. Renew safety valve and prove proper operation to the attending Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2024
Resolved 11 May 2024
Resolution: Safety valves operating properly
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 May 2024
Resolved
In the event of alterations involving the safety of the vessel, the applicable plans shall be submitted for approval. FR circuit for the main bank CO2 fixed fire extinguishing systems for main engine shutdowns has been modified and requires submission of plans for approval to the Marine Safety Center.
46 CFR 71.65-10
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2024
Resolved 5 August 2024
Resolution: MSC approval letter received 30Sep2025 (backdated resolution date to date of letter).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 November 2023
Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment shall be made without the knowledge of the OCMI. Vessel reported a faulty lube oil cooler on the #3 ME. Make permanent repairs w/in 7 days.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 November 2023
Resolved 4 November 2023
Resolution: Received notification that a new cooler was installed, performed tests. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 September 2023
Resolved
Auxiliary machinery vital to the main propulsion system must be provided in duplicate unless the system served is provided in independent duplicate, or otherwise provides continued or restored propulsion capability in the event of a failure or malfunction of any single auxiliary component. VSL reported unstable SSDG #1 resulting in fluctating frequency readings with an unknown cause. Complete troubleshooting to identify a root cause of the malfunction and return to the CG a repair plan and proof of restoring machinery back to normal operating conditions.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 September 2023
Resolved 15 September 2023
Resolution: VSL returned root cause analysis and technician report via email, see documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 April 2023
Resolved
#1 SSDG is not functioning.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 May 2023
Resolved 21 April 2023
Resolution: Generator governor was repaired, inspected generator under ships load and witnessed ast. PSTP; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 July 2022
Resolved
OPERATING GENERATORS MUST PROVIDE A CONTINUOUS AND UN-INTERRUPTED SOURCE OF POWER FOR THE SHIP'S SERVICE LOAD UNDER NORMAL OPERATIONAL CONDITIONS. VESSELS VITAL GENERATOR ENGINE CONTROL MODULE SYSTEM HAS BEEN PROVIDING ERRONEOUS ALARMS, NEGATIVELY IMPACTING RELIABILTY OF GENERATOR. CORRECT WITHIN 7 DAYS, 705C.
CITE: 46 CFR 111.10-4(d)
Action required: 705 - Other - as specified
Due 18 July 2022
Resolved 14 July 2022
Resolution: Vessel crew effected repairs to the satisfaction of the marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 June 2022
Resolved
Automatic propulsion systems, automated electric power management systems, and all associated subsystems and equipment must be capable of meeting load demands from standby to full system rated load, under steady state and maneuvering conditions, without need for manual adjustment or manipulation. #2 SSDG is currently inoperable.
46 CFR 62.35-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2022
Resolved 20 July 2022
Resolution: Replaced the failed coupling. Op-tested. No further CG action needed.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 3 April 2022
Resolved
The design, fabrication and erection of piping constructed under the regulations in 46 CFR Subchapter F (Marine Engineering) must demonstrate leak tightness. Emergency fire pump overboard discharge outboard of the isolation valve is weeping water from the piping.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022
Resolved 20 May 2022
Resolution: Piping renewed and tested. All sat.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 29 June 2020
Resolved
Implement WSF's periodic safety test procedure (PSTP) corrective action plan as indicated on the SIP submittal dated JUL2020 within 90 days.
Action required: 705 - Other - as specified
Resolved 3 August 2021
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 29 June 2020
Resolved
Doors installed in class A fire boundaries, except those which are normally locked shall be of a self-closing type. Remove all hold-back devices and prove doors are self-closing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 1 October 2020
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 29 June 2020
Resolved
Repair all loose cable transit penetrating the class "A" fire boundary and watertight subdivisions at the free-board deck and below.
Action required: 10 - Deficiency Rectified
Resolved 22 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 June 2020
Resolved
Repair all deteriorated electrical cable, missing/loose stuffing tubes, and provide proper cable support for the electrical installation on the main vehicle deck within 90 days.
Action required: 705 - Other - as specified
Due 30 October 2020
Resolved 3 August 2021
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 29 June 2020
Resolved
Replace the painted and delaminated steering gear room vent gasket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 3 August 2021
Resolution: Gaskets replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 29 June 2020
Resolved
Mark steering gear room hatch "keep clear". The current marking is illegible.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 3 August 2021
Resolution: Hatches marked.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 29 June 2020
Resolved
Mark general alarm bells throughout the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 3 August 2021
Resolution: Markings applied.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 June 2020
Resolved
Adjust the QAWTD to the crews locker room to achieve positive contact for each dog.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 3 August 2021
Resolution: Door adjusted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 June 2020
Resolved
Properly support the cable leading to the hazardous locker disconnect switch located in the E/R stores within 90 days.
Action required: 705 - Other - as specified
Due 30 October 2020
Resolved 3 August 2021
Resolution: Support provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 June 2020
Resolved
Re-qualify the explosion proof light installed in the paint locker. The globe does not properly seal.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2020
Resolved 3 August 2021
Resolution: Light replaced.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 29 June 2020
Resolved
Prove the proper operation of the vital generator's high L/O temperature alarm IAW PSTPs.
Action required: 705 - Other - as specified
Due 30 October 2020
Resolved 3 August 2021
Resolution: Item tested at annual COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 June 2020
Resolved
Qualify each bilge suction line from the main bilge pump, either through an operational test or pressure test within 90 days.
Action required: 705 - Other - as specified
Due 30 October 2020
Resolved 3 August 2021
Resolution: Item tested at annual COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 June 2020
Resolved
Repair the hydraulic steering system limit switches to prevent the rudder from contacting rudder stops and over rotating RAI creating an indicating error.
Action required: 10 - Deficiency Rectified
Resolved 22 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 June 2020
Resolved
Propulsion machinery essential to the propulsion and safety of the vessel must be designed to operate. The main diesel engine #3 is currently out of service for a lube oil cooling and associated piping replacement. Vessel permitted to operate with passengers until last run scheduled tie up 0015. Effect permanent replacement prior to carrying passengers for first run 03JUN2020.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2020
Resolved 3 June 2020
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 26 August 2019
Resolved
The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 13 September 2019
Resolution: Vital generator has been repaired and tested all sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 June 2019
Resolved
Each panelboard must meet 171 of IEEE 45-2002. Fire damage to the panel resulted in failure to control both. Fire screen door for both #1 end and #2 end of the vessel, no effective means of controlling at this time, rectify prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2019
Resolved 8 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 June 2019
Resolved
All doors except those that are normally closed shall be of type which are capable of release from the control station. Unable to exercise remote operation of fire screen doors, rectify prior to carrying passengers
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 July 2019
Resolved 8 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 June 2019
Resolved
All fire hoses must be subjected to a test pressure equivalenet to maximum pressure to which they be subjected to service. Pinhole leaks on fire stations #1, #14, #15, #17 and Y valve leaking on fire station #8. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 20 June 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 June 2019
Resolved
The system shall be so designed and arranged that the overhead is effectively sprayed. Sprinkler head was not carrying a full radius circumference and/ or clogged. Corrected on 21JUN2019.
Action required: 10 - Deficiency Rectified
Resolved 20 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 June 2019
Resolved
All lifesaving appliances and arragement on passenger vessels must be in accordance with Subchapter W. Water light gasket was detaching and broken. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 June 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 June 2019
Resolved
Deck penetration shall meet requirement of 46 CFR 72.05-10 (d) through (g). Cable wiring was not sealed by fire retardant material in deck penetration to maintaain structural fire protection integrity.
Action required: 10 - Deficiency Rectified
Resolved 20 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2019
Resolved
#2 MDE producing white smoke. Investigate and prove proper operation of the # 2 MDE.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 April 2019
Resolved 29 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 January 2019
Resolved
Machinery space decks must be constructed of A-0 of equivalent materials including cable penetrations. The multiple cable transit is incorrectly installed and missing hardware (nuts). Provide evidence that the transit is installed in accordance with manufactures specifications.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 January 2019
Resolved 7 January 2019
Resolution: Vessel provided photographs of the transit correctly installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 October 2018
Resolved
Vessel shall continue to operate #1 SSDG and #2 SSDG until Root Cause Analysis Report dated 22Oct18 short-term and long-term corrective actions with regards to phase balance relay (PBR) are approved and implemented.
Note: proposed corrective action to remove PBR from system (jumpered or permanent) is in abeyance until it can be confirmed that the removal of the PBR will not adversely affect system performance. Provide a written statement from the designer stating that the removal of the PBR will not adversely affect the system, or submit system design to MSC for review.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2018
Resolved 20 December 2018
Resolution: Satisfactory dockside trials
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 August 2018
Resolved
Vital switchboard is not operating as designed, causing intermediate losses to main propulsion auxiliary machinery. Effect permanent repairs to the system and replace breaker.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 August 2018
Resolved 24 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 August 2018
Resolved
Vessel is required to operate #1 SSDG and #2 SSDG until Vital switchboard functionality is verified by a CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 August 2018
Resolved 24 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 August 2018
Resolved
Conduct a root cause analysis of the failure of the Vital system and switchboard overcurrent protection coordination. The Vital switchboard bustie was found set to 360A and the Vital Generator breaker was found set to 400A. The approved one-line drawing indicates that the breakers should be set to 600A for the Vital switchboard bustie and to 475A for the Vital Generator bustie, which protects the Vital switchboard from any malfunction of the Vital Generator, ensuring continuous operation of vital loads.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 August 2018
Resolved 24 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 August 2018
Resolved
Issued verbal "no-sail" with passengers when received initial report of DIW incident.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 19 August 2018
Resolved 19 August 2018
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 15 June 2018
Resolved
Where ducts pass through main vertical zone (MVZ) bulkheads, automatic fire dampers shall be fitted adjacent to the bulkhead. The duct between the bulkhead and the damper shall meet the applicable bulkhead requirements. The damper shall be fitted on at least one side of the bulkhead with a visible indicator showing whether the damper is in the open or closed position. Position indicators were missing from the following locations: 2-15-4, 2-15-6, 2-15-1, 2-15-1, 2-15-3. This is not an exhaustive list, assess all MVZ dampers and correct as required.
Action required: 10 - Deficiency Rectified
Resolved 15 June 2018
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 15 June 2018
Resolved
...All automatic fire dampers shall be checked to determine that they are in an operable condition. 4 fire dampers were inoperable. 2-10-1(2), 2-15-4(2), 2-15-5(1), and 2-15-5(2) was zip-tied in the open position. The emergency generator damper did not close.
Action required: 10 - Deficiency Rectified
Resolved 15 June 2018
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 June 2018
Resolved
Vent outlets from all tanks which may emit flammable or combustible vapors...must be fitted with a single screen of corrosion resistant wire of 30x30 mesh. THe fuel vent for the emergency generator was wasted and not attached to vent.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2018
Resolved 2 January 2019
Resolution: Replaced missing screen with 30x30 screen.
07 - Fire Safety › N/A - No Subsystem › Main Vertical zone
Issued 15 June 2018
Resolved
All magnetically controlled fire doors shall be operated locally and by the remote control. Fire screen door FSD 14a did not close properly.
Action required: 10 - Deficiency Rectified
Resolved 15 June 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 June 2018
Resolved
All...fire extinguishing systems...shall be checked to ascertain that the system is in operable condition. Fire station 23 valve handle was difficult to operate; provide cheater bar to allow ease of opening; fire station 15 had a leaking valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2018
Resolved 20 June 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 June 2018
Resolved
All fire hose shall be subjected to a test pressure equivalent to the mazimum pressure. Fire station hose #34 failed.
Action required: 10 - Deficiency Rectified
Resolved 15 June 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 June 2018
Resolved
The life jacket stowage positions must be marked with the words "life jackets" or "child life jackets" as appropriate. The child life jacket sign on the #2 end port side was broken and unclear.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 January 2019
Resolution: Installed new signs identifying children and adult stowage locations.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 15 June 2018
Resolved
In all ventilation systems, manually operated dampers or other suitable means shall be provided in accessible locations, outside the spaces served by the system, for shutting of the passage of air in the event of fire. In Fan Room D, damper missing from galley exhaust duct.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 June 2019
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 15 June 2018
Resolved
Where automatic fire dampers are required, they shall be designed to operate at 165 def F. #1 end port side Fan Room A, a metal bar was found in place of the fusible link.
Action required: 10 - Deficiency Rectified
Resolved 15 June 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 June 2018
Resolved
Each fire hydrant must have at least...one spanner. Fire station 36 and 29 missing spanners.
Action required: 10 - Deficiency Rectified
Resolved 15 June 2018
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 15 June 2018
Resolved
General arrangement plans showing for each deck the fire control station, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means of access to different compartments, decks, etc., and the ventilating systems including particulars of the master fan controls, the position of dampers, the location of the remote means of stopping fans, and identification numbers of the ventilating fans serving each section. Multiple fire dampers on board the vessel were not marked on the fire control plan (FCP); the ends are not identified on the FCP.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 December 2019
Resolution: FCP examined and found corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 June 2018
Resolved
Life jackets must be stowed as follows: the life jackets must be readily accessible. The #1 end stbd side car deck life jacket pull cable for the remote release broke preventing life jackets from releasing.
Action required: 10 - Deficiency Rectified
Resolved 15 June 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 June 2018
Resolved
Vessels not subject to SOLAS...by October 1,1999...fit retroreflective material on all floating appliances. 03 ring buoys on the Sund Deck had wasted SOLAS retroreflective tape.
Action required: 10 - Deficiency Rectified
Resolved 15 June 2018
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 June 2018
Resolved
At least one-half the total number of lifebuoys on the vessel must each be fitted with a self-igniting light. Two of the lifebuoy lights were inoperable.
Action required: 10 - Deficiency Rectified
Resolved 15 June 2018
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 16 March 2018
Resolved
The programmable logic controller which interfaces between the switchboard and alarm and monitoring system uses operating programs that are not stored in volatile memory and do not automatically resume upon supply power resumption. The volatile memory on the switchboard to AMS PLC was wiped during a power reset. The system must be restored to operation and operating programs for alarm systems must be stored in non-volatile memory and automatically operate on supply power resumption.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 April 2018
Resolved 4 June 2018
Resolution: Power cycled to PLC which controlled the malfunctioning alarms. Op test sat.
Fire Fighting › Fire Hydrants › Condition
Issued 12 October 2017
Resolved
The following fire hydrants were found leaking at their respective fire stations: 2, 8, 14, 17, 21, 22, 28, 30. Station 21's hydrant valve would not close fully building pressure in the hose without the valve open. Hydrant drains 21, 28, 29 were leaking during pressure tests. Pressure test each station after repair. 46 CFR 76.17-80.
Action required: 705 - Other - as specified
Due 15 October 2017
Resolved 13 October 2017
Resolution: All leaking fire stations were repaired and found sat.
Fire Fighting › Fire Hydrants › Material
Issued 12 October 2017
Resolved
Spanner wrenches missing at some locations. Ensure each fire hydrant/hose station has required spanner. 46 CFR 76.10-10(g).
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 13 October 2017
Resolution: Missing spanner wrenches replaced. All sat
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 12 October 2017
Resolved
Sprinkler heads found not operating properly in the following zone locations: Zone 8: 2 heads; Zone 7: 1 head; Zone 6: 1 head; Zone 5: 1 head; Zone 4: 2 heads; Zone 3: 3 heads; Zone 2: 0 heads; Zone 1: 1 head. Operationally test each zone/head after repair. 46 CFR 76.17-80.
Action required: 705 - Other - as specified
Due 15 October 2017
Resolved 13 October 2017
Resolution: All sprinkler heads tested and found sat.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 12 October 2017
Resolved
Passenger Emergency Instructions shows donning of kapok-type life jackets which are no longer on board the vessel. Remove kapok section to eliminate confusion. 46 CFR 199.80(c).
Action required: 705 - Other - as specified
Due 11 November 2017
Resolved 13 October 2017
Resolution: Passenger emergency instructions updated and found sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 October 2017
Resolved
Ensure all ring life buoys and their lights meet the applicable standards. 46 CFR 199.211 & 199.70.
Action required: 705 - Other - as specified
Due 15 October 2017
Resolved 13 October 2017
Resolution: All ring life buiys and lights found sat.
Fire Fighting › Fire Hoses › Condition
Issued 12 October 2017
Resolved
Two hoses found leaking. Leaking hoses were destroyed and replaced with new. 46 CFR 76.17-80.
Action required: 705 - Other - as specified
Due 15 October 2017
Resolved 12 October 2017
Resolution: Corrected on the spot.
Fire Fighting › Nozzles › Condition
Issued 12 October 2017
Resolved
Nozzle for fire station 8 was difficult to open/close. Replaced with new. 46 CFR 76.17-80.
Action required: 705 - Other - as specified
Due 15 October 2017
Resolved 12 October 2017
Resolution: Corrected on spot.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 12 October 2017
Resolved
Repair heat activated device for CO2 activation on the #1 M/E alternator and em'cy generator. 46 CFR 76.15-20(b).
Action required: 60 - Rectify deficiencies prior to movement
Due 15 October 2017
Resolved 13 October 2017
Resolution: Heat activated device for CO2 activation on the #1 M/E alternator and em'cy generator replaced in kind and found sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 12 October 2017
Resolved
Repair Repair heat activated device for CO2 activation on the #1 M/E alternator and em'cy generator. 46 CFR 76.15.
Action required: 60 - Rectify deficiencies prior to movement
Due 15 October 2017
Resolved 13 October 2017
Resolution: All items found sat.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 12 October 2017
Resolved
Test #2 paint locker CO2 system, ensuring correction of dampers. 46 CFR 76.15.
Action required: 60 - Rectify deficiencies prior to movement
Due 15 October 2017
Resolved 13 October 2017
Resolution: #2 paint locker CO2 system, dampers repaired and operating sat.
Construction/Loadline › Structures › Door
Issued 12 October 2017
Resolved
Fill/fix holes in the #1 paint locker near and around door. 46 CFR 72.05.
Action required: 60 - Rectify deficiencies prior to movement
Due 15 October 2017
Resolved 13 October 2017
Resolution: All holes in the #1 paint locker near and around door repaired.
Electrical › Electric Generation Source (service) › Generator
Issued 12 October 2017
Resolved
Replace auto voltage regulator for vital generator. 46 CFR 111.12-7.
Action required: 705 - Other - as specified
Due 11 November 2017
Resolved 13 October 2017
Resolution: Auto voltage regulator for vital generator replaced in kind. All sat.
Engineering › Steam Boiler (auxiliary/waste heat) › Gauge Glass
Issued 12 October 2017
Resolved
#1 boiler furnace sight glass to prohibit the free flow of exhaust out. 46 CFR 53.01-3.
Action required: 705 - Other - as specified
Due 11 November 2017
Resolved 13 October 2017
Resolution: All items found sat.
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 12 October 2017
Resolved
Provide drain holes for boiler relief valve piping to ensure no standing water. 46 CFR 53.05-2.
Action required: 705 - Other - as specified
Due 11 November 2017
Resolved 13 October 2017
Resolution: All items found sat.
Electrical › Electric Generation Source (service) › Generator
Issued 12 October 2017
Resolved
#1 & 2 ship service generators do not shut down upon main bank CO2 activation. Ensure proper shutdown. 46 CFR 75.15.
Action required: 705 - Other - as specified
Due 9 February 2018
Resolved 17 December 2019
Resolution: Item issued in error.
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 July 2017
Resolved
Due to vessel in commercial shipyard it has past its due date for re-inspection per 46 cfr71.30. Conduct re-inspection prior to entering passenger service.
Action required: 705 - Other - as specified
Resolved 12 October 2017
Resolution: 2017 COI conducted.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 20 April 2017
Resolved
Repair damaged emergency embarkation light on #2 end upper vehicle ramp, stbd side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 20 April 2017
Resolution: Replaced bulb.
Engineering › Steam Boiler (auxiliary/waste heat) › Expansion Joint
Issued 20 April 2017
Resolved
Repair leak to boiler union metalic expansion joint.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: Replaced expansion joint.
Engineering › Fuel Oil Service System › Hose
Issued 12 January 2017
Resolved
Install manufacturer specific fire sleeves on all cloth jacketed fuel oil, lube oil and hydraulic flexible hoses.
Action required: 705 - Other - as specified
Due 19 February 2017
Resolved 23 February 2017
Resolution: All cloth jacketed fuel oil and lube oil flexible hoses have been replaced with approved SAE J1942 fire rated hoses. All sat.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 12 January 2017
Resolved
Two fire dampers did not fully close. 02-16-2(1) and 02-10-1(2)
Action required: 705 - Other - as specified
Due 26 January 2017
Resolved 12 January 2017
Resolution: Dampers fully operational prior to vessel going into service.
Fire Fighting › Fire Hydrants › Condition
Issued 12 January 2017
Resolved
FS #26 needs valve replaced.
Action required: 705 - Other - as specified
Due 26 January 2017
Resolved 12 January 2017
Resolution: Valve was replaced.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 12 January 2017
Resolved
Provide 04 lifejackets for Engine room crew.
Action required: 705 - Other - as specified
Due 12 January 2017
Resolved 12 January 2017
Resolution: Lifejackets were brought down from upper deck storage for Engine room crew.
Communications › Internal Communications System › Engine Order Telegraph System
Issued 12 January 2017
Resolved
Audible alarm for EOT power failure inoperable both PHs.
Action required: 705 - Other - as specified
Due 26 January 2017
Resolved 15 January 2017
Resolution: EOT audible alarm was repaired.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 26 July 2016
Resolved
Provide amperage labels for all circuit breaker panels for individual breakers, IAW 46CFR111.40-11(b)(2)(iii)
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 13 September 2016
Resolution: All circuit breaker panels have been labeled with amperages and posted on the breaker panels.
Construction/Loadline › Structures › Door
Issued 26 July 2016
Resolved
Provide proof of proper closure of fire screen doors #10 and #19.
Action required: 705 - Other - as specified
Due 2 August 2016
Resolved 4 August 2016
Resolution: Adjusted fire screen doors #10 and #19. Both fully close without assistance.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 1 July 2016
Resolved
Vessel lost AMS (engineering monitoring system) system.
Action required: 705 - Other - as specified
Due 8 July 2016
Resolved 1 July 2016
Resolution: Crew "reset" AMS system and it came back online.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 3 March 2016
Resolved
Repair car deck sprinkle system to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2016
Resolved 4 March 2016
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 3 March 2016
Resolved
Prove proper operation of rescue boat #2 and launching appliance to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2016
Resolved 3 March 2016
Engineering › Fuel Oil Service System › Hose
Issued 1 March 2016
Resolved
Lube oil and fuel oil hoses not fire rated on EDG. Provide fire sleeves IAW SAE J1942.
46 CFR 56.60-25(b)
Action required: 705 - Other - as specified
Due 4 March 2016
Resolved 4 March 2016
Resolution: Correct hoses and fire sleeves installed.