BAY PRINCESS II

BAY PRINCESS II is a 1972 passenger vessel (inspected). The Coast Guard has recorded 99 inspections since 1984, most recently in April 2026, along with 174 deficiencies and 1 casualty investigation in 2021.

Records from 1984 to 2026. Most recent: inspection, 28 April 2026.

Built
1972
Last inspected
28 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG 7383
Flag
UNITED STATES
367566720
Maury page id
psix-47350

Inspections, by type

…with no type recorded14
Years with a record 41 calendar years (1984–2026)
The 99 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)58.2 ft × 20.7 ft × 5.8 ft
Registered tonnagegross 64 / net 43
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGILLIKIN CRAFT INC · BEAUFORT · built 1972
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 6 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Net Ton
64 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG7383MMSI 367566720 · active · compulsorily equipped · granted 1 March 2023, expires 19 March 2033
WCW5612MMSI not assigned · expired · voluntarily equipped · granted 8 May 1996, cancelled 8 July 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 99

28 April 2026 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8357650
3 November 2025 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8262266
25 April 2025 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8118014
30 April 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7903907
7 November 2023 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7820757
2 May 2023 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7678556
27 April 2022 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7433608
15 November 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7331039
28 August 2021 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7300531
30 March 2021 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7165297
31 March 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6912809
18 November 2019 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6832035
29 March 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6638628
20 March 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6358245
20 November 2017 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6294046
21 March 2017 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6106440
22 March 2016 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5830504
22 March 2016 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5839675
27 October 2015 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5751662
20 March 2014 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4819439
1 June 2012 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4330769
24 May 2012 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4320337
25 January 2012 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4231516
6 September 2010 Type not recorded
No type recorded · Station Fire Island · USCG Northeast District (CGD-NE) · Activity 3843680
6 May 2009 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3469019
26 March 2008 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3171497
9 November 2007 Plan Review "T" Boat
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3095998
29 October 2007 Plan Review "T" Boat
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3089275
9 October 2007 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3075889
9 May 2007 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2926331
2 May 2006 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2638428
23 September 2005 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2498850
20 April 2005 Deficiency Check · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2338095
22 June 2004 Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2097687
25 March 2004 Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2031285
30 September 2003 Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1916712
24 March 2003 Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1758237
1 April 2002 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1599511
18 October 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1073911
25 September 2001 Deficiency Check · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1376754
9 August 2001 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1473388
13 March 2001 MARPOL Annex V Examination · Re-Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1395690
7 June 2000 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1403163
13 March 2000 Deficiency Check · Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1415319
4 November 1999 Deficiency Check · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1361183
30 September 1999 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1039110
22 May 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 214361
10 May 1999 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 797259
22 March 1999 Deficiency Check · MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 787202
1 May 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1428948
17 March 1998 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1423046
9 March 1998 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1423047
8 October 1997 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1109128
8 October 1997 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1111168
15 September 1997 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1122436
19 March 1997 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1456523
24 January 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1428615
17 January 1996 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1185478
16 January 1996 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1392595
26 October 1995 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 880831
21 June 1995 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1189571
26 April 1995 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1435621
13 May 1994 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1020500
21 March 1994 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 856255
10 November 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1159919
17 June 1993 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 963096
13 May 1993 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 829944
21 April 1993 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 962209
24 March 1993 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 837837
30 November 1992 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1140724
9 October 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 948615
15 April 1992 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 953797
12 April 1992 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 76443
20 December 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1256379
15 March 1991 Re-Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 924481
27 April 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1215708
6 April 1990 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1219519
23 March 1990 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 911930
6 November 1989 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1020111
19 June 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1044775
13 June 1989 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 894470
5 May 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1036916
5 May 1989 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1200932
5 May 1989 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1206749
10 April 1989 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 897025
23 March 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 897024
2 June 1988 Plan Review "T" Boat · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 888646
26 April 1988 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1036810
7 April 1988 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 994223
26 February 1988 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1332531
20 May 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1310235
29 April 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1022971
23 April 1987 COI Inspection · Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1310231
22 April 1987 Deficiency Check · Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1006619
17 April 1986 Credit Drydock · Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1304158
27 March 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1303792
18 April 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1293562
5 February 1985 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 980018
11 December 1984 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 977722

Deficiency record · 174

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 April 2025 Resolved
Fixed fire system had loose fittings at the top of the bottles which needed repair
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2025
Resolved 30 April 2025
Resolution: Repaired
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 April 2025 Resolved
Need 3 red hand flares
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 30 April 2025
Resolution: purchased
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 April 2025 Resolved
Recharge/replace hand fire extinguisher in accommodation space
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2025
Resolved 30 April 2025
Resolution: repaired
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 April 2025 Resolved
condemned 1 adult lifejacket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 30 April 2025
Resolution: purchased new
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 25 April 2025 Resolved
Crop and renew stbd side aft bulkhead iwo hull in #2 compartment
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2025
Resolved 20 May 2025
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 25 April 2025 Resolved
Crop and renew forward bulkhead in engine room on starboard side iwo hull
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2025
Resolved 20 May 2025
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 25 April 2025 Resolved
Crop and renew aft bulkhead in engine room on starboard side iwo hull
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2025
Resolved 20 May 2025
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 25 April 2025 Resolved
Crop and renew aft bulkhead in engine room on port side iwo hull
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2025
Resolved 20 May 2025
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 25 April 2025 Resolved
Crop and renew forward bulkhead in tank compartment on starboard side iwo hull
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2025
Resolved 20 May 2025
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 25 April 2025 Resolved
Crop and renew aft bulkhead in tank compartment on port side iwo hull
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2025
Resolved 20 May 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 April 2025 Resolved
Treat angel hair in engine room above starboard engine, aft
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2025
Resolved 20 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 May 2023 Resolved
Retroreflective Tape was found to be in a worn condition on 09 PFDs aboard. The vessel owner replaced the retroreflective tape in kind and resolved the deficiency before inspection completion.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 May 2023
Resolved 2 May 2023
Resolution: The vessel owner replaced the retroreflective tape in kind.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 28 April 2022 Resolved
Prove proper operation of engine room bilge alarm. Visual indicator is not illumination on the bridge.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2022
Resolved 29 April 2022
Resolution: Proved proper op.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 April 2022 Resolved
Conducted underway drills and sea trials.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 29 April 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 March 2020 Resolved
Condemned 12 Kapok type I PFDs where closed cell was compromised.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 August 2020
Resolved 11 August 2020
Resolution: Vessel representative replaced the 12 adult PFDs and labled
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 31 March 2020 Resolved
High water/ bilge alarm in the aft steering space was identified inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2020
Resolved 11 August 2020
Resolution: Replaced high water float switch and crew demonstrated proper operation.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 20 March 2018 Resolved
Provide a copy of covered employes under drug and alcohol program. 46CFR16
Action required: 705 - Other - as specified
Due 20 April 2018
Resolved 20 March 2018
Resolution: Provided list.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 20 March 2014 Resolved
Replace waterlight on life float. Light was found to be inoperable.
Due 20 April 2014
Resolved 26 March 2014
Resolution: New waterlight installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 20 March 2014 Resolved
Repair STB engine exhaust leak in fuel tank comp. Exhaust piping was found to have a small leak; wet exhaust leaking water.
Due 20 April 2014
Resolved 26 March 2014
Resolution: Exhaust leak was repaired with in kind fiberglass pipe.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 20 March 2014 Resolved
Post lifejacket donning placard on upper deck. Discussed with o/o to place in lid of bins.
Due 20 April 2014
Resolved 26 March 2014
Resolution: Placards installed in all upper deck life jacket bins.
Engineering › Gasoline Engine (propulsion) › Alternator (4 cycle)
Issued 20 March 2014 Resolved
Repair port side alternator belt. Belt was loose during testing.
Due 20 April 2014
Resolved 26 March 2014
Resolution: Alternators were not in working order and were removed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 20 March 2014 Resolved
Repair collision bulkhead in collision compartment. Bulkhead has rot spots and signs of wharf borers.
Due 20 April 2014
Resolved 26 March 2014
Resolution: Part of affected bulkhead was removed and repaired.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 1 June 2012 Resolved
Provide a valid copy of MIS submission by consortium
Condition: Invalid
Due 5 June 2012
Resolved 5 June 2012
Resolution: O/O provided copy via FAX
Documentation › Markings/Placards › Capacity Marking
Issued 1 June 2012 Resolved
Relabel maximum persons allowed on upper deck to 43
Condition: Placed in Improper Service
Due 5 June 2012
Resolved 1 June 2012
Resolution: corrected on the spot
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 6 May 2009 Resolved
Provide servicing certificate prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2009
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 6 May 2009 Resolved
Provide proof of enrollment in drug testing consortium for all employees.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2009
Lifesaving › Lifefloat › Painter
Issued 6 May 2009 Resolved
Splice painter around body of one lifefloat and provide grouping line to/around body of second. Provide 18 foot lanyards on each waterlight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2009
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 26 March 2008 Resolved
During last Drydock vessel was written a rquirement to submit long term plans for maintenance and repair to numberous areas in engine room with significant wood rot. Satisfactory temporary repairs had been made as necessary, however plan was never submitted to Coast Gaurd for long term repair and maintenance plans. Operator must submit plans for long term maintentance proposal.
Due 20 April 2008
Resolved 20 April 2008
Resolution: Vessel was visited by Coast Guard inspector who wrote requirement on drydock exam. Checked on repairs that had been made to wood rot in engine room. All was found to be satisfactory
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 26 March 2008 Resolved
Hydralic tank in engine room in aft starboard corner, has several wasted hydraulic lines coming off of it that need to be replaced.
Due 20 April 2008
Resolved 20 April 2008
Resolution: Wasted hydraulic lines coming of hydralic tank in aft corner of enginroom were replaced to the satisfaction of attending Coast Guard Marine inspector.
Communications › Radio Communications › EPIRB
Issued 26 March 2008 Resolved
Vessels EPIRB had expired battery. Required operator to replace battery prior to carrying passengers beyond three nautical miles from shore.
Due 20 April 2008
Resolved 20 April 2008
Resolution: Vessel provided new EPIRB battery upon deficiency check.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 9 October 2007 Resolved
Provide detailed plans of fuel tank installation to local OCMI for approval, prior to installation
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2007
Resolved 15 November 2007
Resolution: Approved. See activity # 3095998.
Construction/Loadline › Structures › Deck Plating
Issued 9 October 2007 Resolved
Provide detailed written long term maintenance plan to arrest and treat all surface rotted areas in engineroom, including entire overhead and some plank/frame joints (specifically on port side). Plan is to be submitted prior to 31 Oct 07 and all rot to be arrested and treated prior to next annual inspection in spring 08.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 15 November 2007
Resolution: In lieu of above requirement, O/O has aggressively been scraping and treating all areas. Enough progress has been made to satisfy this requirement but a special note has been written.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 October 2007 Resolved
Conduct general electrical maintenance/housekeeping in and throughout engineroom. Bring all wiring installations into compliance with 46 CFR part 183; such as approved cable, metal clamps, overcurrent protection, dead ends, etc.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2007
Resolved 15 November 2007
Resolution: O/O has made good progress in this area.
Engineering › Fuel Oil Service System › Valve, Control
Issued 9 October 2007 Resolved
Provide fuel shut off valves at, or as close as practicable to, each engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 15 November 2007
Engineering › Bilge Water Management System › Manifold
Issued 9 October 2007 Resolved
Provide metal isolation valve where bait pump PVC piping takes suction from bilge manifold.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2007
Resolved 15 November 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 9 October 2007 Resolved
All watertight bulkheads need repairs, from treating surface rot to patching holes, to re-fastening plywood. Inspect and repair as necessary and as discussed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2007
Resolved 15 November 2007
Resolution: O/O has conducted all repairs as discussed.
Lifesaving › Lifefloat › Retroreflective Material
Issued 9 May 2007 Resolved
Place new retroflective tape to lifefloats.
Due 17 May 2007
Resolved 17 May 2007
Resolution: Placed new retroflective tape to lifefloats.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 9 May 2007 Resolved
Place new retroflective tape on PFD's.
Due 17 May 2007
Resolved 17 May 2007
Resolution: Placed new retroflective tape on PFD''s.
Lifesaving › Hand Flares › Quantity
Issued 9 May 2007 Resolved
Provide three more orange smoke flares and three more red hand flares.
Due 17 May 2007
Resolved 17 May 2007
Resolution: Provided three more orange smoke flares and three more red hand flares.
Lifesaving › Hand Flares › Quantity
Issued 2 May 2006 Resolved
Provide 3 hand and 3 smoke flares.
Due 19 May 2006
Resolved 17 May 2006
Accommodation/Occupational Safety › Other Accommodation Spaces › Insect Screen
Issued 2 May 2006 Resolved
Replace cracked window in pilot house.
Due 19 May 2006
Resolved 31 May 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 2 May 2006 Resolved
Provide globes and cages for all lighting fixtures below deck.
Due 19 May 2006
Resolved 17 May 2006
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 20 April 2005 Resolved
Replace straps on 4 adult lifejackets, vessel restricted to 96 total adults until corrected, correct prior to 04 May 05.
Due 4 May 2005
Resolved 8 May 2005
Resolution: Per phoncon/faxed ltr fm O/O, one strap replaced, 3 new jackets purchased. Receipt for new jackets scanned into documents for this activity.
Communications › Radio Communications › EPIRB
Issued 22 June 2004 Resolved
Provide EPIRB hydrostatic release, until provided vessel is limited to no more than thre (3) miles on a coastwise voyage.
Due 2 July 2004
Resolved 6 July 2004
Construction/Loadline › Hull
Issued 30 September 2003 Resolved
Replace wasting keel bolts in the #2 compartment prior to next operating season. LEGACY COMPONENT DESC: Keel
Due 1 March 2004
Resolved 23 March 2004
Navigation
Issued 24 March 2003 Resolved
Prove proper operation of the stern light , until fixed vessel is limited to daylight or clear visibility sailing.
Due 24 March 2003
Resolved 6 June 2003
Fire Fighting › Fire Pumps
Issued 24 March 2003 Resolved
Prove proper operation of the fire pump prior to sailing.
Due 24 March 2003
Resolved 13 June 2003
Construction/Loadline
Issued 24 March 2003 Resolved
Repair fractured handrails port side forward.
Due 31 March 2003
Resolved 6 June 2003
Engineering
Issued 24 March 2003 Resolved
Prove proper operation of the engineroom and forward compt high water bilge alarms.
Due 31 March 2003
Resolved 6 June 2003
Lifesaving
Issued 24 March 2003 Resolved
Put vessel name on all lifesaving equipment.
Due 6 June 2003
Resolved 13 June 2003
Lifesaving
Issued 24 March 2003 Resolved
Replace rotted flooring on life float.
Due 6 June 2003
Resolved 13 June 2003
Lifesaving
Issued 24 March 2003 Resolved
Register EPIRB.
Due 6 June 2003
Resolved 13 June 2003
Documentation
Issued 24 March 2003 Resolved
Provide safety radio certificate.
Due 6 June 2003
Resolved 13 June 2003
Documentation
Issued 24 March 2003 Resolved
Provide proof of a drug testing program.
Due 6 June 2003
Resolved 13 June 2003
Documentation
Issued 24 March 2003 Resolved
Start logbook for drills, epirb testing, etc.
Due 6 June 2003
Resolved 13 June 2003
Navigation
Issued 24 March 2003 Resolved
Provide anchors onboard.
Due 6 June 2003
Resolved 13 June 2003
Electrical
Issued 24 March 2003 Resolved
Complete all electrical renewal work and test.
Due 6 June 2003
Resolved 13 June 2003
Documentation › Certificates/Documents
Issued 1 April 2002 Resolved
Provide proof of Master's license.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2002
Navigation › Piloting/Steering
Issued 1 April 2002 Resolved
Provide proof of Coast Guard Light List. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2002
Navigation › Piloting/Steering
Issued 1 April 2002 Resolved
Provide proof of current tide and tidal current tables. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2002
Navigation › Piloting/Steering
Issued 1 April 2002 Resolved
Provide proof of Inland Navigation Rules. LEGACY COMPONENT DESC: Inland Navigation Rules
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 1 April 2002 Resolved
Provide proof of complete first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 1 April 2002 Resolved
Provide proof of servicing of fixed firefighting CO2 bottle. LEGACY COMPONENT DESC: Tanks
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 1 April 2002 Resolved
Provide proof of servicing of portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2002
Accommodation/Occupational Safety
Issued 25 September 2001 Resolved
REPAIR CRACKED WELD ON FORWARD, PORTSIDE RAIL STANCHION.
Condition: Unknown
Due 25 September 2001
Resolved 25 September 2001
Construction/Loadline
Issued 25 September 2001 Resolved
REPAIR AND STRENGTHEN AS PROPOSED PLANKING ON STARBOARD BOW WHICH IS WORN FROM CONTACT WITH VESSEL'S ANCHOR.
Condition: Unknown
Due 25 September 2001
Resolved 25 September 2001
Construction/Loadline
Issued 25 September 2001 Resolved
REPAIR LOOSE OUTBOARD FITTING FOR MIDSHIP STARBOARD BILGE THROUGH HULL AS PROPOSED.
Condition: Unknown
Due 25 September 2001
Resolved 25 September 2001
Accommodation/Occupational Safety
Issued 25 September 2001 Resolved
REPAIR AS ORIGINAL CRACKED WOOD SUPPORT IN WAY OF PORT SIDE FORWARD RAIL STANCHION.
Condition: Unknown
Due 25 September 2001
Resolved 25 September 2001
Documentation
Issued 9 August 2001 Resolved
SHOW PROOF OF RADIO OPERATOR LICENSE TO ATTENDING MARINE INSPECTOR BY 09SEP01.
Condition: Unknown
Due 9 August 2001
Resolved 9 August 2001
Navigation
Issued 9 August 2001 Resolved
PROVIDE EVIDENCE OF TIDE TABLES, TIDAL CURRENT TABLES AND PROPER COAST PILOT TO ATTENDING MARINE INSPECTOR BY 09SEP01.
Condition: Unknown
Due 9 August 2001
Resolved 9 August 2001
Lifesaving
Issued 9 August 2001 Resolved
REPLACE RETROREFLECTIVE TAPE ON LIFERINGS AND BOTH LIFEFLOATS TO ATTENDING MARINE INSPECTOR BY 09SEP01.
Condition: Unknown
Due 9 August 2001
Resolved 9 August 2001
Electrical
Issued 13 March 2001 Resolved
PROVIDE PROTECTIVE LENS COVERING FOR LIGHT IN MAIN PASSENGER CABIN, PORT SIDE.
Condition: Unknown
Due 20 March 2001
Resolved 17 April 2001
Lifesaving
Issued 13 March 2001 Resolved
REPLACE SEA-PAINTER FOR ALL L/Fs.
Condition: Unknown
Due 20 March 2001
Resolved 17 April 2001
Fire Fighting
Issued 13 March 2001 Resolved
PROPERLY MOUNT B-I FIRE EXTINGUISHER IN THE PILOT HOUSE.
Condition: Unknown
Due 20 March 2001
Resolved 17 April 2001
Lifesaving
Issued 13 March 2001 Resolved
REPLACE ONE ADULT PFD.
Condition: Unknown
Due 20 March 2001
Resolved 17 April 2001
Documentation
Issued 13 March 2001 Resolved
COME INTO COMPLIANCE WITH USCG DRUG TESTING REGULATIONS.
Condition: Unknown
Due 20 March 2001
Resolved 17 April 2001
Lifesaving
Issued 13 March 2000 Resolved
PROVIDE OR REPAIR 9 ADULT PFDs. VESSEL CAPACITY REDUCED TO 91 ADULTS UNTILCLEARED.
Condition: Unknown
Due 13 March 2000
Resolved 13 March 2000
Construction/Loadline
Issued 13 March 2000 Resolved
MAKE REPAIRS TO BILGE PIPING IN E/R IWO MANIFOLD. SMALL LEAKS PRESENT. SYSTEM STILL DRAWS FROM BILGES, BUT HAS SMALL LEAKS.
Condition: Unknown
Due 24 March 2000
Resolved 23 March 2000
Construction/Loadline
Issued 13 March 2000 Resolved
INSTALL SCREEN ON BILGE SUCTION IN #4 COMPT.
Condition: Unknown
Due 24 March 2000
Resolved 23 March 2000
Construction/Loadline
Issued 13 March 2000 Resolved
USE METAL VICE PVC FITTINGS ON BILGE SUCTION SYSTEM THROUGHOUT VESSEL.
Condition: Unknown
Due 24 March 2000
Resolved 23 March 2000
Engineering
Issued 13 March 2000 Resolved
DOUBLE CLAMP ALL EXHAUST FITTINGS IN E/R AND #4 COMPT.
Condition: Unknown
Due 24 March 2000
Resolved 23 March 2000
Engineering
Issued 4 November 1999 Resolved
INSTALL 30 X 30 MESH SCREENS IN FUEL TANK VENTS.
Condition: Unknown
Due 15 November 1999
Resolved 4 November 1999
Navigation
Issued 4 November 1999 Resolved
PROPERLY SECURE STERN LIGHT.
Condition: Unknown
Due 15 November 1999
Resolved 4 November 1999
Construction/Loadline
Issued 4 November 1999 Resolved
ROT PRESENT THROUGHOUT UPPER AREAS OF FOREPEAK. FRESH AND RAIN WATER COMING THROUGH AREA IWO SIDESHELL/MAIN DECK CONNECTION. CORRECT LEAKING.
Condition: Unknown
Due 15 November 1999
Resolved 4 November 1999
Construction/Loadline
Issued 4 November 1999 Resolved
RENEW BALL VALVE SERVING MSD DISCHARGE.
Condition: Unknown
Due 15 November 1999
Resolved 4 November 1999
Construction/Loadline
Issued 4 November 1999 Resolved
ADD ADDITIONAL OR RENEW EXISTING BUTT BLOCK BOLTS IN ALL BUTT BLOCKS THROUGHOUT VESSEL. ELECTROLYSIS PRESENT.
Condition: Unknown
Due 15 November 1999
Resolved 4 November 1999
Engineering
Issued 4 November 1999 Resolved
DOUBLE CLAMP ALL EXHAUST FITTINGS IN E/R, FUEL TANK SPACE, AND LAZ.
Condition: Unknown
Due 15 November 1999
Resolved 4 November 1999
Construction/Loadline
Issued 4 November 1999 Resolved
MAKE BULKHEADS BETWEEN E/R AND FUEL TANK SPACE AND ALSO BETWEEN FUEL TANK SPACE AND LAZ WATERTIGHT. SPECIFICALLY THE AREAS IWO SHELF/CLAMPS P & S SIDES AND AROUND EXHAUST AND BILGE PIPING PENETRATIONS.
Condition: Unknown
Due 15 November 1999
Resolved 4 November 1999
Construction/Loadline
Issued 4 November 1999 Resolved
ADD ADDITIONAL BOLTS IN TRANSOM WHERE BOTTOM CLAMP MEETS HULL PLANKING.
Condition: Unknown
Due 15 November 1999
Resolved 4 November 1999
Construction/Loadline
Issued 4 November 1999 Resolved
PULL HULL FASTENERS IWO AREAS MARKED BY MARINE INSPECTOR. A MINIMUM OF 8 FROM BOTH THE PORT AND STBD SIDES AND SOME FROM THE TRANSOM AREA.
Condition: Unknown
Due 15 November 1999
Resolved 4 November 1999
Construction/Loadline
Issued 4 November 1999 Resolved
REMOVE PLYWOOD BRACES IN FOREPEAK TO FACILITATE INSPECTION.
Condition: Unknown
Due 15 November 1999
Resolved 4 November 1999
Construction/Loadline
Issued 4 November 1999 Resolved
FOREPEAK, #4 FRAME, STBD SIDE, CRACKED. SISTER IT.
Condition: Unknown
Due 4 November 1999
Resolved 4 November 1999
Construction/Loadline
Issued 4 November 1999 Resolved
FOREPEAK, #3 FRAME HEAD, PORTSIDE, ROTTED OFF. SISTER FRAME UPTO AND INCLUDING FRAME HEAD.
Condition: Unknown
Due 4 November 1999
Resolved 4 November 1999
Construction/Loadline
Issued 4 November 1999 Resolved
CROP OUT TO GOOD WOOD THE STEM AND ALL AREAS OF THE KEEL IWO WORM INFESTED AREAS. DO NOT INSTALL GRAVING PIECES UNTIL CONDICTION OF WOOD IS WITNESSEDBY ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 November 1999
Resolved 4 November 1999
Construction/Loadline
Issued 4 November 1999 Resolved
REMOVE ALL DEBRIS IN ALL BILGES AND IWO ALL BUTT BLOCKS AND STERN TUBES.
Condition: Unknown
Due 15 November 1999
Resolved 4 November 1999
Fire Fighting
Issued 10 May 1999 Resolved
CONDUCT INSTALLATION INSPECTION AND TEST OF FIXED CO2/FIRE DETECTION SYSTEM/PIPING.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Lifesaving
Issued 22 March 1999 Resolved
PROVIDE 1 CHILD AND 32 ADULT PFDs. VESSELS CAPACITY REDUCED TO 68 ADULTS AND 9 CHILDREN UNTIL CLEARED.
Condition: Unknown
Due 29 March 2000
Resolved 25 May 1999
Lifesaving
Issued 22 March 1999 Resolved
RECONFIGURE UPPER DECK RAILS TO COMPLY W/ 46 CFR 177.900 FOR EXCURSION VESSELS.
Condition: Unknown
Due 22 March 1999
Resolved 22 March 1999
Engineering
Issued 22 March 1999 Resolved
RENEW PORT FUEL SHUT OFF VALVE.
Condition: Unknown
Due 13 April 1999
Resolved 30 March 1999
Engineering
Issued 22 March 1999 Resolved
DOUBLE CLAMP ALL EXHAUST FITTINGS IN #4 COMPT.
Condition: Unknown
Due 13 April 1999
Resolved 30 March 1999
Lifesaving
Issued 22 March 1999 Resolved
ADD ADDITIONAL LAGS TO ALL LIFE RAIL MOUNTS.
Condition: Unknown
Due 13 April 1999
Resolved 30 March 1999
Fire Fighting
Issued 22 March 1999 Resolved
HYDROSTATICALLY TEST THE 3 B-II EXTINGUSHERS REQUIRING IT. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 29 March 1999
Resolved 30 March 1999
Electrical
Issued 22 March 1999 Resolved
LABEL ALL BREAKERS THROUGHOUT VESSEL.
Condition: Unknown
Due 13 April 1999
Resolved 30 March 1999
Lifesaving
Issued 22 March 1999 Resolved
RENEW WEBBING ON BOTH L/FS. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 29 March 1999
Resolved 30 March 1999
Accommodation/Occupational Safety
Issued 1 May 1998 Resolved
RECONFIGURE UPPER DECK RAIL TO BE IN COMPLIANCE WITH 46 CFR 177.900 FOR VESSELS ENGAGED IN EXCURSION TRIPS.
Condition: Unknown
Due 1 May 1998
Resolved 1 May 1998
Fire Fighting
Issued 16 January 1996 Resolved
RENEW PLASTIC FIRE HOSE NOZZLE W/METALLIC ONE.
Condition: Unknown
Due 16 January 1996
Resolved 16 January 1996
Construction/Loadline
Issued 16 January 1996 Resolved
CLOSE HOLES IN MAIN DECK IN FORE PEAK AND LAZERETTE, PORT SIDE.
Condition: Unknown
Due 16 January 1996
Resolved 16 January 1996
Lifesaving
Issued 16 January 1996 Resolved
PROVIDE 406 MHZ EPIRB._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 January 1996
Resolved 16 January 1996
Navigation
Issued 16 January 1996 Resolved
PROVIDE/POST EMERGENCY BROADCAST INSTRUCTIONS.
Condition: Unknown
Due 16 January 1996
Resolved 16 January 1996
Engineering
Issued 26 April 1995 Resolved
EFFECT REPAIRS TO THE CRACKED WELD ON THE STBD MAIN DIESEL ENGINE OUTBOARD EXHAUST PIPE IN WAY OF THE COOLING WATER NOZZEL.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Fire Fighting
Issued 26 April 1995 Resolved
RENEW THE STBD SIDE FIREHOSE.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Lifesaving
Issued 26 April 1995 Resolved
RELOCATE THE UPPER DECK ADULT LIFE PRESERVER BOX TO AFT OF THE PILOT HOUSE.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Lifesaving
Issued 26 April 1995 Resolved
PROVIDE A LADDER TO THE PILOT HOUSE ROOF FOR ACCESS TO THE PRIMARY LIFESAVING EQUIPMENT.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Lifesaving
Issued 26 April 1995 Resolved
REPLACE LIFE PRESERVER RETROREFLECTIVE TAPE AS NEEDED.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Electrical
Issued 26 April 1995 Resolved
PROVIDE METAL ELECTRICAL WIRING TIES THROUGH OUT THE VESSEL.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Engineering
Issued 26 April 1995 Resolved
RENEW THE AFTER RUBBER HOSE METAL HOSE CLAMP, LOCATED ON THE PROPELLER SHAFT STUFFING BOXES ON THE PORT AND STBD SIDES.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Accommodation/Occupational Safety
Issued 21 March 1994 Resolved
ATTACH THE UPPER HAND RAILS PORT AND STARBOARD SIDES OF THE 01 DECK TO THE BULWARKS FORWARD ALONGSIDE THE WHEEL HOUSE.
Condition: Unknown
Due 21 March 1994
Resolved 21 March 1994
Electrical
Issued 21 March 1994 Resolved
PROVIDE OVERSPEED PROTECTION FOR THE GENERATOR PRIME MOVER, SET LESS THAN 15% ABOVE RATED SPEED FOR GENERATOR BELL. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 March 1994
Resolved 21 March 1994
Documentation
Issued 24 March 1993 Resolved
PROVIDE COPY OF 46CFR PARTS 166-199.
Condition: Unknown
Due 24 April 1993
Resolved 22 April 1993
Fire Fighting
Issued 24 March 1993 Resolved
MARK LOCATION OF FIRE EXTINGUISHERS
Condition: Unknown
Due 24 April 1993
Resolved 22 April 1993
Construction/Loadline
Issued 24 March 1993 Resolved
REPLACE IN KIND MAIN DECK FRAMING IN WAY OF THE OUTBOARD SIDE OF BOTH ENGINES.
Condition: Unknown
Due 31 October 1993
Resolved 22 April 1993
Electrical
Issued 24 March 1993 Resolved
INSTALL COVER FOR ELECTRICAL SWITCH/RECEPTICAL ON BRIDGE CONSOLE.
Condition: Unknown
Due 24 April 1993
Resolved 22 April 1993
Engineering
Issued 24 March 1993 Resolved
PROPERLY SECURE AND PREVENT FROM DAMAGE FLEX. FUEL LINES FROM FILTERS TO ENGINES.
Condition: Unknown
Due 24 May 1993
Resolved 22 April 1993
Lifesaving
Issued 24 March 1993 Resolved
PROVIDE RESCUE PLATFORM/LADDER OR OTHER MEAMS TO RECOVER A PERSON OVERBOARD.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Construction/Loadline
Issued 24 March 1993 Resolved
LABEL STOP VALVES AND PROVIDE DIRECTIONS FOR OPERATION OF BILGE PUMPING SYSTEM AT THE MANIFOLD
Condition: Unknown
Due 24 April 1993
Resolved 22 April 1993
Engineering
Issued 24 March 1993 Resolved
INSTALL MACHINERY GUARDS FOR STARBOARD ENGINE AND GENERATOR.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Construction/Loadline
Issued 24 March 1993 Resolved
REMOVE THE ENGINE ROOM BILGE SUCTION THAT FEEDS INTO THE MSD HOLDING TANK.
Condition: Unknown
Due 24 April 1993
Resolved 22 April 1993
Engineering
Issued 24 March 1993 Resolved
REMOVE OR MAKE PROPER THE SIGHT GLASS FOR THE LUBE OIL HOLDING TANK.
Condition: Unknown
Due 24 April 1993
Resolved 22 April 1993
Construction/Loadline
Issued 9 October 1992 Resolved
RENEW BACKING BLOCK FOR STBD MAIN ENGINE SEA WATER OVBD THRU HULL.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Lifesaving
Issued 9 October 1992 Resolved
PROVE PROPER OPERATION OF STBD B/A WATERLIGHT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Engineering
Issued 9 October 1992 Resolved
RENEW GENERATOR FUEL HOSE WITH PROPER WIRE INSERTED, FIRE RETARDENT TYPE WITH CORRECT ENDS OR USE TUBING OF THE CORRECT TYPE.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Construction/Loadline
Issued 9 October 1992 Resolved
PROVE PROPER OPERATION AND WATERTIGHTNESS OF BOW AND STERN FLUSH DECK HATCHES.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Electrical
Issued 9 October 1992 Resolved
PROVIDE PROPER BONDING STRAPS FOR PORT AND STBD FUEL TANK FILL PIPES.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Engineering
Issued 9 October 1992 Resolved
PROVE PROPER OPERATION OF PORT AND STBD EMERGENCY FUEL SHUTOFFS.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Construction/Loadline
Issued 9 October 1992 Resolved
RENEW THREE STEM THRU HULL BOLTS WHERE STEM IS SCARFED TO KEEL.
Condition: Unknown
Due 9 October 1992
Resolved 9 October 1992
Documentation
Issued 15 April 1992 Resolved
PROVIDE PROOF OF DRUG TESTING PROGRAMS IN AFFECT IAW 46CFR 4 AND 16.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Accommodation/Occupational Safety
Issued 27 April 1990 Resolved
D1-PROVIDE CHAIN LINK FENCING/WIRE MESH OR AN EQUIVALENT BETWEEN THE RAILS ON THE SECOND DECK RAIL. SEE CFR46-177.35(C)
Condition: Unknown
Due 27 April 1990
Resolved 27 April 1990
Lifesaving
Issued 6 April 1990 Resolved
D1-PROVIDE (1) ADULT LIFE PRESERVERS THE TOTAL NUMBER OF PERSONS ALLOWED IS 86 UNTIL D1 IS COMPLETE.
Condition: Unknown
Due 6 April 1990
Resolved 6 April 1990
Engineering
Issued 6 April 1990 Resolved
E1-REPAIR OR REPLACE BILGE VALVE IN FWD COMPARTMENT.
Condition: Unknown
Due 6 April 1990
Resolved 6 April 1990
Documentation
Issued 10 April 1989 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Navigation
Issued 10 April 1989 Resolved
PROVIDE ONBOARD THE PROPER NAVIGATIONAL DAY SHAPES (3 BLACK BALLS).
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Lifesaving
Issued 10 April 1989 Resolved
STENCIL ALL LIFE FLOAT PADDELS AND RESTENCIL BOTH LIFE FLOATS.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Electrical
Issued 10 April 1989 Resolved
MAKE REPAIRS TO AND PROVE OPERATION OF THE AC AMP METER.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Accommodation/Occupational Safety
Issued 10 April 1989 Resolved
MAKE REPAIRS TO AND PROVE OPERATION OF THE TOILET.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Electrical
Issued 10 April 1989 Resolved
PROVIDE DOUBLE CLAMPS ON ALL GENERATOR WATER PUMP DISCHARGE HOSES.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Electrical
Issued 10 April 1989 Resolved
CLEAN ALL BATTERY TERMINALS.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Electrical
Issued 10 April 1989 Resolved
MARK ALL ELECTRICAL DISTRIBUTION PANELS.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Engineering
Issued 10 April 1989 Resolved
REPACK STARBOARD SHAFT GLAN.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Electrical
Issued 10 April 1989 Resolved
SUBMIT "AS BUILT" DRAWINGS ON THE FOLLOWING: A) MODIFICATIONS TO THE 12 VDC SYSTEM; B) MODIFICATIONS TO THE 120 VAC SYSTEM AND C) SHORE POWER LIGHTING CIRCUIT.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Navigation
Issued 10 April 1989 Resolved
PROVIDE ONBOARD AN UP TO DATE CHART OF THE AREA BETWEEN SANDY HOOK, NJ AND SEA GIRT, NJ.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Lifesaving
Issued 7 April 1988 Resolved
ATTACH APPROVED PLATES TO LIFEFLOATS UPON RECEIPT.
Condition: Unknown
Due 7 April 1988
Resolved 7 April 1988
Lifesaving
Issued 7 April 1988 Resolved
PROVIDE FIFTEEN (15) ADDITIONAL ADULT PFD'S. PASSENGER CAPACITY REDUCED BYFIFTEEN (15) UNDER ALL OPERATING CONDITIONS.
Condition: Unknown
Due 7 April 1988
Resolved 7 April 1988
Engineering
Issued 7 April 1988 Resolved
REMOVE OIL FROM ENGINE ROOM BILGES.
Condition: Unknown
Due 7 April 1988
Resolved 7 April 1988
Lifesaving
Issued 29 April 1987 Resolved
RENEW TO ORIGINAL THE LIFE FLOAT PLATFORM ON THE STBD LIFE FLOAT. PLATFORMMUST BE GRADE A OR B MARINE OR EXTERIOR 5/8" PLYWOOD. HOLES TO BE SIZED SPACED AS PER 46 CFR 160.027.3(B)(3). FINISH TO BE TWO COATS OF MARINE PAINT TO BE COMPLETED BY 23MAY87.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Electrical
Issued 23 April 1987 Resolved
PROVIDE REPAIRS TO THE BROKEN LATCH ELECTRIC DISTRIBUTION PANEL THAT IS LOCATED IN THE PASSAGEWAY.
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987
Lifesaving
Issued 23 April 1987 Resolved
PROVIDE MANUFACTURES CERTIFICATION LABELS FOR THE LIFEFLOAT.
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987
Lifesaving
Issued 23 April 1987 Resolved
PROVIDE 18 ADULT TYPE I PERSONAL FLOATATION DEVICES WITH VESSEL NAME INSCRIBED AND WITH RETROREFLECTIVE TAPE. VESSEL IS RESTRICTED TO 69 PERSONS UNTIL THIS ITEM IS CLEARED.
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987
Navigation
Issued 23 April 1987 Resolved
PROVIDE A CURRENT PUBLICATION OF THE NAVIGATION RULES OF THE ROAD.
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987
Navigation
Issued 23 April 1987 Resolved
PROVIDE THREE BLACK BALL DAYSHAPES AS REQUIRED BY THE NAVIGATION RULES OF THE ROAD FOR A VESSEL OVER TWELVE METERS.
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987
Construction/Loadline
Issued 22 April 1987 Resolved
MAKE OPERABLE THE BOW & AFT COMPARTMENT SCUTTLE DOGGING MECHANISMS.
Condition: Unknown
Due 22 April 1987
Resolved 22 April 1987
Construction/Loadline
Issued 22 April 1987 Resolved
REFASTEN THE BULKHEAD TRANSVERSE STIFFENER MEMBER IN THE FORWARD COMPARTMENT AND RECAULK THE BULKHEAD TO HULL JOINTS.
Condition: Unknown
Due 22 April 1987
Resolved 22 April 1987
Construction/Loadline
Issued 22 April 1987 Resolved
PROVIDE A PLUG FOR THE 1" GATE VALVE FOR THE RAW WATER SERVICE TIE WHICH IS NO LONGER IN USE. SUBJECT VALVE IS LOCATED UNDER THE AUXILIARY GENERATOR.
Condition: Unknown
Due 22 April 1987
Resolved 22 April 1987
Electrical
Issued 22 April 1987 Resolved
PROVIDE A GROUND WIRE TO THE PORT ENGINES RAW WATER SUCTION VALVE ARRANGEMENT.
Condition: Unknown
Due 22 April 1987
Resolved 22 April 1987
Construction/Loadline
Issued 22 April 1987 Resolved
RENEW THE SHELF CLAMPING MEMBER IN THE AFTER COMPARTMENT STARBOARD SIDE. (THE OUTBOARD MEMBER IS FULLY ROTTED.).
Condition: Unknown
Due 22 April 1987
Resolved 22 April 1987
Construction/Loadline
Issued 22 April 1987 Resolved
RENEW SISTER OR ADD AN ADDITIONAL FRAMING MEMBER TO THE SECOND TRANSOM FRAME FROM THE STARBOARD SIDE.
Condition: Unknown
Due 22 April 1987
Resolved 22 April 1987
Construction/Loadline
Issued 22 April 1987 Resolved
IN THE FORWARD COMPARTMENT PROVIDE A SISTER FRAMING MEMBER TO THE #2 PORT SIDE HULL FRAME WHICH HAS SPLIT.
Condition: Unknown
Due 22 April 1987
Resolved 22 April 1987
Construction/Loadline
Issued 22 April 1987 Resolved
RENEW THE FASTENERS FOR THE INTERMEDIATE TRANSVERSE FRAMING MEMBERS WHERE THEY TIE INTO THE HULL FRAMES.
Condition: Unknown
Due 22 April 1987
Resolved 22 April 1987
Construction/Loadline
Issued 22 April 1987 Resolved
RENEW THE #5 PORT INTERMEDIATE FRAMING BRACKET.
Condition: Unknown
Due 22 April 1987
Resolved 22 April 1987
Engineering
Issued 17 April 1986 Resolved
STENCIL LOCATION OF EMERGENCY FUEL OIL SHUT OFF VALVES.
Condition: Unknown
Due 17 April 1986
Resolved 17 April 1986
Lifesaving
Issued 17 April 1986 Resolved
STENCIL LIFEJACKET LOCKERS AND SEPARATELY STOW CHILD PFD'S FROM THE ADULT PFD'S.
Condition: Unknown
Due 17 April 1986
Resolved 17 April 1986
Construction/Loadline
Issued 17 April 1986 Resolved
SECURE VESSEL'S HATCHES WITH A LANYARD OR PROPER RETAINING DEVICE.
Condition: Unknown
Due 17 April 1986
Resolved 17 April 1986
Fire Fighting
Issued 17 April 1986 Resolved
REMOVE FROM THE VESSEL AND HAVE HYDROSTATIC TESTED ONE 15LB CO2 EXTINGUISHER.
Condition: Unknown
Due 17 April 1986
Resolved 17 April 1986
Navigation
Issued 17 April 1986 Resolved
PROVIDE ON BOARD CURRENT EDITION OF COAST PILOT.
Condition: Unknown
Due 17 April 1986
Resolved 17 April 1986
Navigation
Issued 17 April 1986 Resolved
MAKE OPERATIVE AND PROVE OPERATION OF ANCHOR LIGHT.
Condition: Unknown
Due 17 April 1986
Resolved 17 April 1986

Casualty record · 1

28 August 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 7300531
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.