MAURY USCG vessel records Sign in
← All vessels

MISS VICKIE

MISS VICKIE is a 1998 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 1998, most recently in March 2006, along with 16 deficiencies and 1 casualty investigation in 2005.

Records from 1998 to 2006. Most recent: inspection, 6 March 2006.

Built
1998
Last inspected
6 March 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8964226 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCY4529
473554
Flag
UNITED STATES
369576000 (licence lapsed)
Maury page id
psix-473554

Inspections, by type

…with no type recorded1
Years with a record 8 calendar years (1998–2006)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it87 - Regulatory (Subpart C or D), Gross Ton
298 - Convention (Subpart B), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
89 - Convention (Subpart B), Net Ton
269 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCY4529MMSI 369576000 · cancelled · compulsorily equipped · granted 11 June 1998, cancelled 27 November 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 21

6 March 2006 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2596488
23 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2571562
13 September 2005 Administrative Inspection · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2490976
12 May 2005 Examination of Repairs · Annual Inspection · Damage Survey · Deficiency Check · MARPOL Annex V Examination · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2357381
12 May 2005 Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2482116
4 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2303742
10 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290191
1 November 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2232668
20 July 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2139344
20 May 2004 MARPOL Annex V Examination · Periodic Inspection · Deficiency Check · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2076065
20 April 2004 Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 2052463
23 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971736
14 November 2003 Hull Examination
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1946680
14 May 2003 Annual Inspection
Physical examination · Activities Europe · Activity 1784085
29 November 2001 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1373691
22 May 2001 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1366357
23 May 2000 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395446
8 July 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463488
27 July 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1129528
22 May 1998 Inclining Experiment · Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421504
30 January 1998 Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471499

Deficiency record · 16

Electrical › Electric Generation Source (service) › Generator
Issued 20 May 2005 Resolved
Prove proper operation of the port SSDG. Engine fails to start.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2005
Resolved 20 May 2005
Resolution: Witnessed proper operation of port SSDG.
Lifesaving › Buoyant Apparatus › Marking
Issued 20 May 2005 Resolved
Stencil vsl's name on all ring buoys.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 4 June 2005
Resolution: Rcvd email notification from master that item satisfactorily corrected.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 20 May 2005 Resolved
Remove all non DOT portable fire extinguishers and SCBA's from vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 25 July 2005
Resolution: Rcvd notification from vsl''s master that item was satisfactorily corrected. All sat
Fire Fighting › Fire Hoses › Material
Issued 20 May 2005 Resolved
Remove all non CG approved fire hoses.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 17 June 2005
Resolution: Rcvd email notification from master that item satisfactorily corrected.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 May 2005 Resolved
Provide vessel's original Certificate of Inspection and post in pilot house.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 17 June 2005
Resolution: Rcvd email notification from master that item satisfactorily corrected.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 20 May 2005 Resolved
Update fire control plan.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 17 June 2005
Resolution: Rcvd email notification from master that item satisfactorily corrected.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 20 May 2005 Resolved
Repair cracked exhaust piping, stbd MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 4 June 2005
Resolution: Rcvd email notification from master that item satisfactorily corrected.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 20 May 2005 Resolved
Install rudder angle indicator at both pilot stations.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 25 July 2005
Resolution: Rcvd notification from vsl''s master that item was satisfactorily corrected. All sat
Communications › Internal Communications System › Portable Radios
Issued 20 May 2005 Resolved
Provide communications btwn the pilot house and the engineroom.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 25 July 2005
Resolution: Rcvd notification from vsl''s master that portable radios onboard. All sat
Fire Fighting › Nozzles › Condition
Issued 20 May 2005 Resolved
Fix leaks and lubricate bails on fire nozzles.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 25 July 2005
Resolution: Rcvd notification from vsl''s master that new CG approved fire nozzles onboard. All sat
Lifesaving › Visual Distress Signals (General) › Approval
Issued 20 May 2005 Resolved
Provide CG approved parachute flares.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 4 July 2005
Resolution: Rcvd email notification from master that item satisfactorily corrected.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 May 2005 Resolved
Properly stow lead acid batteries located in the generator room. Batteries must be stored in approved boxes and properly secured to vsl.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2005
Resolved 20 May 2005
Resolution: Batteries placed in approved boxes and properly secured to vsl.
Lifesaving › Lifebuoys
Issued 14 May 2003 Resolved
Replace 3 lifebuoys due to cracking. Ensure life rings are stenciled with vessel name
Due 14 June 2003
Resolved 7 June 2003
Resolution: Received an email from the [name withheld], master [name withheld], stating the above items was corrected
Lifesaving
Issued 14 May 2003 Resolved
The vessel is limited to - Total persons allowed 75. This is due to the number that can be carried by the liferafts onboard
Action required: 705 - Other - as specified
Due 22 May 2004
Resolved 22 May 2004
Resolution: fouth 25 man raft installed.
Lifesaving
Issued 14 May 2003 Resolved
Install new hydrostatic release for EPIRB
Due 14 July 2003
Resolved 22 May 2004
Resolution: inspected new Hydro.
Accommodation/Occupational Safety
Issued 14 May 2003 Resolved
Emergency escape hatches from the engine room missing required stencil - Emergency Exit Keep Clear
Due 14 June 2003
Resolved 7 June 2003
Resolution: Received an email from the [name withheld], master [name withheld], stating the above items was corrected.

Casualty record · 1

12 May 2005Routine · role: Involved in a Marine Casualty · activity 2482116
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.