MAURY USCG vessel records Sign in
← All vessels

REEF CHIEF

REEF CHIEF is a 1972 passenger vessel (inspected). The Coast Guard has recorded 51 inspections since 1985, most recently in February 2020, along with 45 deficiencies.

Records from 1985 to 2020. Most recent: inspection, 24 February 2020.

Built
1972
Last inspected
24 February 2020
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBC6742
Flag
UNITED STATES
367529000 (licence lapsed)
Maury page id
psix-47358

Inspections, by type

…with no type recorded6
Years with a record 27 calendar years (1985–2020)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.1 ft × 13.4 ft × 4.7 ft
Registered tonnagegross 16 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderC V PEDERSEN BOATYARD · DELTAVILLE, VA, UNITED STATES · built 1972
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 30 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Regulatory (Subpart C or D), Gross Ton
14 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WBC6742MMSI 367529000 · expired · compulsorily equipped · granted 15 September 2006, cancelled 11 February 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 51

24 February 2020 Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 6915486
21 December 2017 COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6339533
5 July 2012 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4368155
21 May 2008 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3212677
26 April 2007 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2915932
10 May 2006 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2643432
27 April 2006 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2632946
10 March 2005 Deficiency Check · Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2306448
21 July 2004 Annual Inspection · Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2130600
17 June 2003 MARPOL Annex V Examination · Deficiency Check · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1819983
10 December 2002 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1726966
13 August 2002 Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1661031
25 April 2002 Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1636398
24 April 2002 MARPOL Annex V Examination · COI Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1599110
22 May 2001 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1432511
27 June 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1403174
1 May 2000 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1455870
28 April 1999 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1378662
21 May 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 790786
4 May 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 790779
29 April 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1106422
13 April 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 16741
6 November 1996 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 859562
8 May 1996 Hull Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1446338
30 April 1996 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1088111
16 May 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 928669
6 December 1994 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1141331
9 May 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 861590
7 December 1993 Inclining Experiment
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1160515
11 May 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 836865
4 May 1993 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1146557
21 January 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1140933
2 June 1992 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 957707
2 June 1992 Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1266885
14 November 1991 Deficiency Check · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 938540
1 October 1991 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1248778
15 April 1991 Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 915498
15 October 1990 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 921394
16 May 1990 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 900828
13 September 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1344060
12 June 1989 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1351940
20 September 1988 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1202918
17 June 1988 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1202767
19 May 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1028539
12 May 1987 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1024074
12 May 1987 Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1331991
27 May 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 991014
5 May 1986 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1300703
3 April 1986 Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1003110
29 April 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1287668
1 April 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 982834

Deficiency record · 45

Navigation › Piloting/Steering › US Coast Pilot
Issued 10 May 2006 Resolved
Provide U.S. Coast Pilot onboard or equivalent onboard vessel.
Action required: 705 - Other - as specified
Due 10 June 2006
Resolved 12 May 2006
Lifesaving › Lifefloat › Markings
Issued 10 May 2006 Resolved
Mark lifefloat with vessels name.
Action required: 705 - Other - as specified
Due 10 June 2006
Resolved 10 May 2006
Lifesaving › Lifefloat › Paddle
Issued 10 May 2006 Resolved
Lash paddles to vessels lifefloat.
Action required: 705 - Other - as specified
Due 10 June 2006
Resolved 10 May 2006
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 10 May 2006 Resolved
Replace retroreflective material on 2 adult and 3 child PFD's.
Action required: 705 - Other - as specified
Due 10 June 2006
Resolved 10 May 2006
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 10 May 2006 Resolved
Make proper repairs to nylon strap in way of Adult Type I PFD as indicated by Marine Inspector.
Action required: 705 - Other - as specified
Due 10 June 2006
Resolved 10 May 2006
Lifesaving › Lifefloat › Float-free Link
Issued 10 May 2006 Resolved
Replace float free link in way of vessels lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2006
Lifesaving › Lifefloat › Painter
Issued 10 May 2006 Resolved
Properly attach buoyant apparatus to lifefloat painter in accordance with 46CFR180.137(e)(3).
Action required: 705 - Other - as specified
Due 10 June 2006
Resolved 10 May 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 May 2006 Resolved
Properly attach line in way of strobe light to ring life buoy.
Action required: 705 - Other - as specified
Due 10 June 2006
Resolved 10 May 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 May 2006 Resolved
Provide proper first aid kit.
Action required: 705 - Other - as specified
Due 10 June 2006
Resolved 12 May 2006
Fire Fighting › Fire Bucket › Stenciling
Issued 10 May 2006 Resolved
Properly mark vessels fire buckets.
Action required: 705 - Other - as specified
Due 10 June 2006
Resolved 10 May 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 10 May 2006 Resolved
Replace fire bracket for portable B-II fire extinguishering in main compartment.
Action required: 705 - Other - as specified
Due 10 June 2006
Resolved 12 May 2006
Engineering › Bilge Water Management System › Pump
Issued 10 May 2006 Resolved
Install indicator light at central location to indicate operation of submersible electrical bilge pumps.
Action required: 705 - Other - as specified
Due 10 June 2006
Resolved 12 May 2006
Engineering › Bilge Water Management System › Hose
Issued 10 May 2006 Resolved
Provide adequate length hose in way of portable bilge pump.
Action required: 705 - Other - as specified
Due 10 June 2006
Resolved 10 May 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 April 2006 Resolved
Make repairs to stbd aft side shell frame, prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2006
Construction/Loadline › Hull › Transverse Frame
Issued 27 April 2006 Resolved
Make repairs to cracked deck beam prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2006
Lifesaving › Buoyant Apparatus › Lifeline
Issued 10 March 2005 Resolved
Renew lifeline in way of 12 person Buoyant Apparatus.
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 10 March 2005
Engineering › Bilge Water Management System › Pump
Issued 10 March 2005 Resolved
Prove proper operation of automatic bilge pump in way of engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 21 July 2004 Resolved
Provide one (1) B-II portable fire extinguisher
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2004
Resolution: Installed additional BII portable fire extinguisher
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 July 2004 Resolved
Prove proper operation of forward compartment high level bilge alarm
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 July 2004
Resolution: Verified proper ops of HLBA
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 17 June 2003 Resolved
Provide proof of renewal for drug testing consortium.
Action required: 705 - Other - as specified
Due 24 June 2003
Resolved 18 June 2003
Resolution: Corrected. Received fax copy of renewal contract.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 June 2003 Resolved
Repair waterlight for ringbuoy.
Action required: 705 - Other - as specified
Due 24 June 2003
Resolved 18 June 2003
Resolution: Corrected. Received fax copy of invoice indicating new light was purchased.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 June 2003 Resolved
Repair forward bilge alarm audible signal.
Action required: 705 - Other - as specified
Due 24 June 2003
Resolved 18 June 2003
Resolution: Corrected. Received fax copy of invoice indicating new alarm was purchased.
Construction/Loadline › Structures
Issued 25 April 2002 Resolved
Replace elbows to seacock for a cockpit drains LEGACY COMPONENT DESC: Scupper
Condition: Improper/Lack of Maintenance
Due 24 May 2002
Resolved 16 July 2002
Resolution: Corrected.
Lifesaving › Lifebuoys
Issued 24 April 2002 Resolved
Renew Retro-reflective tape on life float not later than 24May02.
Condition: Improper/Lack of Maintenance
Due 24 May 2002
Resolved 16 July 2002
Resolution: Corrected.
Communications › Radio Communications
Issued 24 April 2002 Resolved
Place vessel's name on EPIRB not later than 24May02. LEGACY COMPONENT DESC: EPIRB
Condition: Unknown
Due 24 May 2002
Resolved 16 July 2002
Resolution: Corrected.
Documentation › Markings/Placards
Issued 24 April 2002 Resolved
Post PFD Donning placard not later than 24May02.
Condition: Unknown
Due 24 May 2002
Resolved 16 July 2002
Resolution: Corrected.
Communications › Alarms/Indicators
Issued 24 April 2002 Resolved
Renew Bilge high level alarm for engine compartment not later than 24May02. LEGACY COMPONENT DESC: High Water Alarm
Condition: Unknown
Due 24 May 2002
Resolved 16 July 2002
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety
Issued 24 April 2002 Resolved
Install mesh netting or courses between the top course rail and bulwark so that no opening exceeds 4 inches not later than 24Jun02. LEGACY COMPONENT DESC: Deck Rail
Due 24 June 2002
Resolved 16 July 2002
Resolution: Corrected.
Engineering › Bilge Water Management System
Issued 24 April 2002 Resolved
Replace Bilge hoses with reinforced hose and provide in line valves not later than 24May02. LEGACY COMPONENT DESC: Hose
Condition: Placed in Improper Service
Due 24 May 2002
Resolved 16 July 2002
Resolution: Corrected.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 24 April 2002 Resolved
Replace the fixed seating not later than 24May02. LEGACY COMPONENT DESC: Open Deck Space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 December 2002
Resolved 10 December 2002
Resolution: Corrected. Extended original due date upon owner''s request.
Lifesaving
Issued 27 June 2000 Resolved
Replace 6 orange smoke flares by 27JUN00.
Condition: Unknown
Due 27 June 2000
Resolved 28 June 2000
Lifesaving
Issued 30 April 1996 Resolved
INSTALL NEW RETRO-REFLECTIVE TAPE ON 5 ADULT PFD's AND CLEAN REMAINING PFD's.
Condition: Unknown
Due 6 May 1996
Resolved 9 May 1996
Lifesaving
Issued 30 April 1996 Resolved
INSTALL NEW BATTERY IN WATERLIGHT FOR BUOYANT APPARATUS.
Condition: Unknown
Due 6 May 1996
Resolved 9 May 1996
Fire Fighting
Issued 4 May 1993 Resolved
Service all fire extinguishers.
Condition: Unknown
Due 3 August 1993
Resolved 3 August 1993
Fire Fighting
Issued 4 May 1993 Resolved
Stencil "FIRE EXTINGUISHER INSIDE" on outside of door to compartment holding extinguisher so as to be easily visible to passangers.
Condition: Unknown
Due 3 August 1993
Resolved 3 August 1993
Lifesaving
Issued 2 June 1992 Resolved
REPAIR ALL COTTON STRAPS ON LIFE PRESERVERS
Condition: Unknown
Due 17 June 1992
Resolved 17 June 1992
Engineering
Issued 2 June 1992 Resolved
INSTALL FLAME SHIELD ON RACOR FUEL FILTER
Condition: Unknown
Due 17 June 1992
Resolved 17 June 1992
Engineering
Issued 2 June 1992 Resolved
REMOVE RUBBER HOSE FROM FUEL SUPPLY LINE AT TANK
Condition: Unknown
Due 17 June 1992
Resolved 17 June 1992
Electrical
Issued 2 June 1992 Resolved
INSTALL COVER ON LIGHT IN ENGINE ROOM.
Condition: Unknown
Due 17 June 1992
Resolved 17 June 1992
Lifesaving
Issued 2 June 1992 Resolved
REMOVE CROSS BAR ON BUOYANT APPARATUS STOWAGE AREA.
Condition: Unknown
Due 17 June 1992
Resolved 17 June 1992
Lifesaving
Issued 2 June 1992 Resolved
PROVIDE NEW WEAK LINK FOR BUOYANT APPARATUS
Condition: Unknown
Due 17 June 1992
Resolved 17 June 1992
Construction/Loadline
Issued 2 June 1992 Resolved
REPLACE AND DOUBLE CLAMP SEA WATER HOSE TO HEAD
Condition: Unknown
Due 17 June 1992
Resolved 17 June 1992
Construction/Loadline
Issued 15 April 1991 Resolved
INSTALL A COLLISION BULKHEAD THAT COMPLIES WITH SUBCHAPTER "S".
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Navigation
Issued 12 May 1987 Resolved
DEMONSTRATE THE LORAN AND DEPTH FINDER ELECTRONICS EQUIPMENT TO THE SATIS- FACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR PRIOR TO 30 MAY 1987.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Navigation
Issued 29 April 1985 Resolved
PROVIDE DAY SHAPES - 3 BLACK BALLS.
Condition: Unknown
Due 29 April 1985
Resolved 29 April 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.