MAURY USCG vessel records Sign in
← All vessels

OAKLAND

OAKLAND is a 1999 freight ship. The Coast Guard has recorded 37 inspections since 2000, most recently in December 2016, along with 13 deficiencies — 1 with no resolution recorded — and 5 operational controls.

Records from 2000 to 2016. Most recent: inspection, 17 December 2016.

Built
1999
Last inspected
17 December 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9205627 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-4736

Inspections, by type

…with no type recorded12
…past their stated due date1
Years with a record 13 calendar years (2000–2016)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it29128 - Displacement, Ton
23622 - Dead Weight, Ton
14527 - Convention (Subpart B), Gross Ton
8337 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 37

17 December 2016 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6055468
30 November 2016 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6050128
27 June 2016 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5921847
19 April 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5856741
12 October 2015 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5740817
9 May 2012 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4307112
18 February 2012 ISPS III Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4246333
4 December 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4201090
4 December 2011 PI Safety Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4201397
3 December 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4200742
3 December 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4510866
3 December 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4517173
19 January 2011 MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3929289
9 May 2008 ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3202220
22 September 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3063541
27 April 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2915519
27 April 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2916895
27 April 2007 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2916904
3 June 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2668996
13 March 2006 PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2597779
26 July 2005 Administrative Inspection
Administrative · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 2441043
20 July 2005 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2431294
15 July 2005 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2427937
17 February 2005 Ballast Water Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2291511
17 February 2005 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2294774
13 August 2004 ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2163548
15 June 2004 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2096712
29 October 2003 MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1935537
29 October 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1939022
17 March 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1757937
21 January 2003 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1733406
5 January 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1725885
15 July 2002 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1646773
9 February 2002 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1483521
27 August 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 146645
14 June 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 291066
25 April 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 277097

Deficiency record · 13

Engineering › Sea-water System (primary cooling) › Piping
Issued 17 December 2016 No resolution recorded
1499-Other (Prop. and Aux. machinery)-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. A temporary repair was found on a sea water pipe that supplies cooling water to the ship's main generators. 74SOLAS(14) I/11 - 40ac.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 January 2017 — due date passed with no resolution recorded
Engineering › Freshwater Generation System › Piping
Issued 19 April 2016 Resolved
After any survey of the ship has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. Modifications were made to drain lines in engine room and A/C room without Class approval. Crew was using a hose from the engine room shop to deliver drinking water to the cascade tank.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 June 2016
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 4 December 2011 Resolved
2535; The company should establish and implement procedures to ensure the ship is maintained in conformity with applicable rules and regulations. There has been a breakdown of the vessels safety management system.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2011
Resolved 5 December 2011
Resolution: Corrective Action Plan to prevent reoccurrence is to be made.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 4 December 2011 Resolved
2535; Company has not established guidance for securing bags of rice in cargo holds after loading.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2011
Resolved 5 December 2011
Resolution: Corrective Action Plan to prevent reoccurrence is to be made.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 4 December 2011 Resolved
2535; Company has provided risk assessment forms which include cargo hold inspections#TOKO-07-05A. However, only an initial form has been filled out dated 7/1/2010. No assessment form was filled out prior to the crewmembers entering cargo hold #2.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2011
Resolved 5 December 2011
Resolution: Corrective Action Plan to prevent reoccurrence is to be made.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 4 December 2011 Resolved
2535; The Company should establish procedures, plans and instructions for key shipboard operations for the safety of the crew and environment. Company form TOKO-SM-01-08 for safety meeting (Deck) was not carried out prior to the crewmembers entering cargo hold #2.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2011
Resolved 5 December 2011
Resolution: Corrective Action Plan to prevent reoccurrence is to be made.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 4 December 2011 Resolved
2535; Storage plan as per ships SMS section 7-4BC reference 4.3.1 is recommended to be made by Supercargo or [name withheld] plan has been made out by company. No guidance is mentioned by the company regarding the securing of bagged rice after loading cargo.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2011
Resolved 5 December 2011
Resolution: Corrective Action Plan to prevent reoccurrence is to be made.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 4 December 2011 Resolved
2535; Due to the objective evidence the Captain of the Port of San Francisco questions the adequacy of the implementation of the vessels Safety Management System. An external audit is recommended to be conducted prior to the vessels departure, by the Flag State or Recognized Organization to determine whether the ship is operating in accordance with the ISM code.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2011
Resolved 5 December 2011
Resolution: NKK Class Surveyor conducted a external Safety Management System audit.
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 9 May 2008 Resolved
Verify condition of emergency generator in all aspects of operation, to include but not limited to starting system, batteries, battery charger system, prime mover operation, and emergency switchboard. Prior to movement to the satisfaction of class. SOLAS 74 as amended Ch II-1 Reg 42 1.3.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2008
Resolution: Received NKK Report on 09MAY08. All 4 batteries were replaced. Conducted start test for the prime mover using both battery banks (6x). Auto power supply test for E-switchboard, 2x using ea. battery bank. Charging test for batteries. All tests sat.
Documentation › Certificates/Documents › IOPP Certificate
Issued 17 February 2005 Resolved
Update the IOPP certificate to include the S/B L.O. Drain tank and the S/B L.O. Sludge Tank. MARPOL 73/78 Annex I/17 To the satisfaction of the US Coast Guard.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 July 2005
Resolved 15 July 2005
Resolution: SECTOR LA/LB VERIFIED IOPP CERTICATE UPDATED.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 17 February 2005 Resolved
Update the bilge and sludge piping arrangements to correspond with the bilge piping diagram. There is a pipe directly connecting the sludge pump to the bilge system. MARPOL 73/78 Annex I/17. To the satisfaction of the US Coast Guard, prior to next US port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 July 2005
Resolved 15 July 2005
Resolution: SECTOR LA/LB VERIFIED REMOVAL OF PIPE FROM SLUDGE PUMP TO BILGE SYSTEM AND VERIFIED UPDATED SYSTEM DIAGRAM.
Documentation › Logs/Records
Issued 21 January 2003 Resolved
In the Oil Record Book, under the C-12-3 entries, include the name of the tank emptied and the quantity of contents retained. LEGACY COMPONENT DESC: Oil Record Book
Action required: 15 - Rectify deficiencies by next port
Due 21 January 2003
Resolved 17 March 2003
Resolution: Proper entries have been made in Oil Record Book.
Documentation › Logs/Records
Issued 21 January 2003 Resolved
Include the quantities of oil residue (sludge) retained on board in #1 and #2 W.O. TK's in the Oil Record Book entries under C-11. LEGACY COMPONENT DESC: Oil Record Book
Action required: 15 - Rectify deficiencies by next port
Due 21 January 2003
Resolved 17 March 2003
Resolution: Proper entries have been made in Oil Record Book.

Ownership record