MAURY USCG vessel records Sign in
← All vessels

ROMANDA SUE

ROMANDA SUE is a 1972 offshore supply vessel. The Coast Guard has recorded 56 inspections since 1981, most recently in August 2024, along with 45 deficiencies.

Records from 1981 to 2024. Most recent: inspection, 6 August 2024.

Built
1972
Last inspected
6 August 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH6949
Flag
BAHAMAS, THE
366977210, 367643220 (licence lapsed)
Maury page id
psix-47366

Inspections, by type

…with no type recorded14
Years with a record 35 calendar years (1981–2024)
The 56 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it91 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDH6949MMSI 367643220 · expired · compulsorily equipped · granted 9 October 2014, cancelled 14 December 2024
WDB9492MMSI 366977210 · expired · compulsorily equipped · granted 10 September 2004, cancelled 15 November 2014
WCY8975MMSI not assigned · cancelled · compulsorily equipped · granted 23 February 1999, cancelled 9 September 2004
WBT9118MMSI not assigned · expired · compulsorily equipped · granted 13 February 1998, cancelled 26 July 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 56

6 August 2024 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7977721
4 October 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6281565
12 June 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6173553
16 February 2016 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5815532
14 May 2012 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4311555
1 May 2012 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4299849
24 February 2011 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3951986
19 February 2010 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3682088
9 February 2010 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3677631
2 April 2009 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3447495
8 May 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3201795
9 April 2008 Type not recorded
No type recorded · USCGC TEMPEST (WPC 2) · Activity 3183091
19 April 2007 Internal Structural Exam · Hull Examination · Examination of Repairs · Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2910374
30 May 2006 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2664922
3 March 2006 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2595163
24 March 2005 Hull Examination · Examination of Repairs · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2310801
20 September 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2200369
18 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978068
2 June 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1807796
19 April 2002 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1602080
9 March 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401427
8 March 2000 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1372950
12 March 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423144
29 December 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 16588
14 January 1998 Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446594
12 January 1998 Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1453444
11 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 24476
11 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1428884
1 May 1997 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419786
29 April 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1091698
7 July 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 764984
3 July 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 201388
22 May 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445090
29 April 1995 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431525
26 April 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1426901
21 April 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403619
21 April 1992 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417444
21 May 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1228492
12 April 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1212463
12 April 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1326751
13 April 1990 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 909941
31 August 1989 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1202645
13 April 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1203582
15 April 1988 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1341439
10 September 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002026
14 April 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1006074
8 December 1986 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332842
15 April 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309468
21 November 1985 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 994154
9 May 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 982945
9 April 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1289018
4 May 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281743
10 April 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 974140
14 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967304
6 May 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279543
22 May 1981 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 966617

Deficiency record · 45

Engineering › Lubricating Oil Service System › Tube
Issued 24 February 2011 Resolved
Provide "glass" sight glass for lube oil tank. Lube oil storage tank had plastic site glass.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2011
Communications › Public Address System › Loudspeaker
Issued 2 April 2009 Resolved
Provide Public Address System and Ensure Emergency power provided.
Due 9 May 2009
Resolved 9 April 2009
Resolution: Received faxed confirmation of installation of PA system.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 2 April 2009 Resolved
Vessel limited to one hundred (100) miles offshore until NAVTEX receiver installed.
Action required: 705 - Other - as specified
Resolved 9 April 2009
Resolution: Received fax confirmation that NAVTEX had been installed
Documentation › Markings/Placards › Hull Identification Number (HIN)
Issued 2 April 2009 Resolved
Provide permanent offical number on hull.
Due 9 May 2009
Resolved 2 April 2009
Resolution: Vessel official number permanently marked in engine room bulkhead.
Communications › Radio Communications › Emergency Source of Power
Issued 19 April 2007 Resolved
Re-establish reserve emergency power for VHF radio prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2007
Lifesaving › Lifebuoys › Serviceable
Issued 19 April 2007 Resolved
Replace two unserviceable lifebuoys prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2007
Engineering › Steering Gear System › Hydraulic Hose
Issued 3 March 2006 Resolved
Renew chaffed hose on port side hydraulic cylinder and protect renewed hose from chaffing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2006
Engineering › Steering Gear System › Linkage
Issued 3 March 2006 Resolved
Properly secure all pins in steering system linkage
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 3 March 2006 Resolved
Remove all boxes blocking access to stove electrical disconnect
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2006
Engineering › Bilge Water Management System › Valve
Issued 3 March 2006 Resolved
Label all bilge valves and provide means to operate valves (proper handles, properly affixed).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2006
Navigation › Piloting/Steering › Marine Charts
Issued 3 March 2006 Resolved
Provide updated charts and all required local notice to mariners
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2006
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 3 March 2006 Resolved
Hydrostatically test both engine room air receivers to 1.5 times MAWP due to inability to complete accurate visual internal inspection. Complete this test prior to 2007 reinspection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 July 2007
Resolved 7 May 2007
Resolution: Vsl had both air receivers hydrostatically tested to 300 psi on 16APR2007 by Galliano Safety Svc.
Engineering › Compressed Air System (start air) › Valve
Issued 3 March 2006 Resolved
Renew both engine room air receiver relief valves due to existing valves painted and unreliable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2006
Engineering › Fuel Oil Service System › Piping
Issued 3 March 2006 Resolved
Correct leaks on fuel oil transfer system piping and remove or cap off vent located on transfer pump housing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 3 March 2006 Resolved
Provided emergency lighting fixture to illuminate engine room access door and machinery space emergency escape ladder.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 3 March 2006 Resolved
Renew engine room light fixture cover
Due 17 March 2006
Resolved 6 March 2006
Lifesaving › Lifefloat › Pendant
Issued 3 March 2006 Resolved
Provide and install sufficient line between lifefloats to allow first lifefloat to be deployed to water prior to second lifefloat being disturbed, or provide additional weaklink and painter line for second lifefloat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2006
Resolution: Owner/operator chose to install longer penant between lifefloats.
Electrical › Electric Generation Source (service) › Generator
Issued 3 March 2006 Resolved
Professionally clean port and starboard generator armatures.
Due 17 March 2006
Resolved 6 March 2006
Stability › Watertight Integrity › General
Issued 3 March 2006 Resolved
Properly adjust all watertight doors throughout vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 March 2006
Lifesaving › Buoyant Apparatus
Issued 2 June 2003 Resolved
Replace lifefloat and sea painter.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2003
Resolution: Sea painter and float replaced.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 2 June 2003 Resolved
Label Main Engine stops in wheel house.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2003
Resolution: Stops labled.
Navigation › Piloting/Steering › Magnetic Compass
Issued 2 June 2003 Resolved
Repair compass light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2003
Resolution: Comass light repaired
Stability › Watertight Integrity
Issued 2 June 2003 Resolved
Adjust engine room escape hatch
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2003
Resolution: Engine room hatch adjusted.
Lifesaving
Issued 2 June 2003 Resolved
Replace wasted chains on rescue platform
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2003
Resolution: Chains replaced
Documentation › Logs/Records
Issued 19 April 2002 Resolved
RADIO LOG NOT PROVIDED. LEGACY COMPONENT DESC: RADIO LOG
Due 19 April 2002
Resolved 19 April 2002
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 19 April 2002 Resolved
ALL REQUIRED NAV PUBS NOT PROVIDED.
Due 19 April 2002
Resolved 19 April 2002
Communications › Internal Communications System
Issued 19 April 2002 Resolved
PUBLIC ADDRESS SYSTEM NOT INSTALLED. LEGACY COMPONENT DESC: PA SYSTEM
Due 19 April 2002
Resolved 19 April 2002
Navigation › Piloting/Steering
Issued 19 April 2002 Resolved
TWO NAV LIGHTS NOT WORKING. LEGACY COMPONENT DESC: NAV LIGHTS
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2002
Resolved 19 April 2002
Navigation
Issued 11 January 1998 Resolved
MAKE PROPER AND PERMENANT REPAIRS TO BOTH PORT AND STBD RUDDER SHAFT PACKING GLANDS, CURRENTLY LEAKING EXCESSIVELY.
Condition: Unknown
Due 11 January 1998
Resolved 11 January 1998
Navigation
Issued 11 January 1998 Resolved
RENEW GASKET TO STEERING ROOM HATCH.
Condition: Unknown
Due 11 January 1998
Resolved 11 January 1998
Engineering
Issued 11 January 1998 Resolved
MAKE PROPER AND PERMENANT REPAIRS TO THE HYD OIL TANK IN THE ENGINE ROOM PORT SIDE. CURRENTLY LEAKING L/O INTO BILGES.
Condition: Unknown
Due 11 January 1998
Resolved 11 January 1998
Construction/Loadline
Issued 11 January 1998 Resolved
CLEAN ENGINE ROOM BILGES TO REMOVE ALL OIL DUE TO TANK LEAKAGE.
Condition: Unknown
Due 11 January 1998
Resolved 11 January 1998
Engineering
Issued 11 January 1998 Resolved
PROPERLY AND PERMENANTLY MOUNT F/O PUMP CONTROL SWITCH STBD SIDE CURRENTLY HANGING FROM WIRES.
Condition: Unknown
Due 11 January 1998
Resolved 11 January 1998
Electrical
Issued 11 January 1998 Resolved
PROPERLY LABEL ALL BREAKERS IN THE ENGINE ROOM BREAKER PANEL, CURRENTLY NOTLABELED.
Condition: Unknown
Due 11 January 1998
Resolved 11 January 1998
Electrical
Issued 11 January 1998 Resolved
MAKE PROPER ELECTRICAL HOOK-UP FOR WELDING MACHINE IN AIR COMP ROOM, CURRENTLY IMPROPERLY HOOKED UP WITH EXTENSION CORD.
Condition: Unknown
Due 11 January 1998
Resolved 11 January 1998
Fire Fighting
Issued 11 January 1998 Resolved
FIRE STATION PORT SIDE INOP. NOZZEL FROZEN, REPAIR/REPLACE.
Condition: Unknown
Due 11 January 1998
Resolved 11 January 1998
Fire Fighting
Issued 11 January 1998 Resolved
FIRE STATION STBD SIDE INOP. NOZZEL FROZEN, REPAIR/REPLACE.
Condition: Unknown
Due 11 January 1998
Resolved 11 January 1998
Engineering
Issued 11 January 1998 Resolved
REPLACE F/O VENT FLAME SCREEN ON F/O VENT PORT SIDE CENTER VENT.
Condition: Unknown
Due 11 January 1998
Resolved 11 January 1998
Electrical
Issued 11 January 1998 Resolved
REMOVE MAKESHIFT EXTENSION CORD FROM BRIDGE GOING TO PORTABLE RADIO.
Condition: Unknown
Due 11 January 1998
Resolved 11 January 1998
Deck/Cargo
Issued 11 January 1998 Resolved
MAKE PROPER AND PERMENANT REPAIRS TO THE ANCHOR WINDLASS, FWD, CURRENTLY INOP, NO ANCHOR ATTCHED.
Condition: Unknown
Due 11 January 1998
Resolved 11 January 1998
Navigation
Issued 11 January 1998 Resolved
DE-WATER STEERING COMPARTMENT AND GAS FREE MAKE AVAILABLE FOR CG INSPECTION.
Condition: Unknown
Due 11 January 1998
Resolved 11 January 1998
Deck/Cargo
Issued 12 April 1991 Resolved
INSTALL MISSING ANCHOR WINCH ONCE REPAIRED. MAIL PROOF OF INSTALLATION TO: U.S. COAST GUARD_x001C_ P.O. BOX 989_x001C_ HOUMA, LA. 70361_x001C_
Condition: Unknown
Due 12 April 1991
Resolved 12 April 1991
Construction/Loadline
Issued 9 April 1985 Resolved
INSTALL PROPER GUARDS ON THE BILGE PUMP AND ON THE POTABLE WATER PUMP.
Condition: Unknown
Due 9 April 1985
Resolved 9 April 1985
Construction/Loadline
Issued 9 April 1985 Resolved
CROP AND RENEW #2 VERTICAL FRAME, PORT SIDE, FOREPEAK TANK.
Condition: Unknown
Due 9 April 1985
Resolved 9 April 1985
Lifesaving
Issued 9 April 1985 Resolved
PROVIDE A FLOAT-FREE LINK FOR THE INSTALLED LIFEFLOATS ON THE PORT SIDE.
Condition: Unknown
Due 9 April 1985
Resolved 9 April 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.