CARIBE BULKER
CARIBE BULKER is a 1969 freight ship. The Coast Guard has recorded 55 inspections since 1998, most recently in November 2005, along with 105 deficiencies — 7 with no resolution recorded — and 5 operational controls.
Records from 1998 to 2005. Most recent: inspection, 26 November 2005.
- Built
- 1969
- Last inspected
- 26 November 2005
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 105 recorded · 7 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
6925185 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3ELF6
473713
Flag
PANAMA
—
Maury page id
psix-473713
Inspections, by type
…with no type recorded33
…past their stated due date2
Years with a record
8 calendar years (1998–2005)
The 55 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it4097 - Regulatory (Subpart C or D), Gross Ton
1533 - Regulatory (Subpart C or D), Net Ton
6657 - Dead Weight, Ton
1533 - Regulatory (Subpart C or D), Net Ton
6657 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 55
26 November 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2540846
19 October 2005
ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2512166
22 August 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2465927
23 June 2005
ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2394471
23 June 2005
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2400591
9 May 2005
Random ISPS/MTSA/PSC · Spot Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2352875
8 April 2005
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2326302
18 February 2005
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2295246
11 February 2005
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2293509
10 February 2005
MARPOL Annex I Examination · ISPS III Exam · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2288161
19 January 2005
ISPS II Exam · Spot Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2275765
28 December 2004
ISPS I Exam
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2263497
28 October 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2229803
27 October 2004
Random ISPS/MTSA/PSC · Spot Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2226416
6 October 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2216029
18 September 2004
PII Safety Exam · ISPS I Exam · Ballast Water Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2196609
29 August 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2180197
24 August 2004
PI Safety Exam · ISPS I Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2384900
11 July 2004
ISPS II Exam
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2129133
14 May 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2067759
18 March 2004
Periodic Inspection · MTSA/ISPS Verification
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2023560
30 July 2003
Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1862760
24 July 2003
Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1856217
2 April 2003
Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1767197
23 January 2003
Ballast Water Examination · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1734494
3 October 2002
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1681068
12 August 2002
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1660160
5 July 2002
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1639634
8 May 2002
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1614527
2 May 2002
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1610123
25 April 2002
Periodic Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1609463
5 March 2002
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1491448
2 January 2002
Periodic Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1474588
28 August 2001
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 293211
25 July 2001
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 292195
15 July 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 291914
26 March 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 288630
20 March 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 288307
7 August 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 638576
31 July 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 280734
28 June 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 211990
28 June 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 279627
6 March 2000
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 275510
14 January 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 273768
28 December 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 436004
17 November 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 434935
7 September 1999
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 432346
10 June 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 429477
13 March 1999
Type not recorded
No type recorded · USCGC VIGILANT (WMEC 617) · Activity 1496625
13 February 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 425581
10 January 1999
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 424359
24 December 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 423749
12 September 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 420248
13 July 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 417951
10 April 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 414797
Deficiency record · 105
Lifesaving › Thermal Protective Aids › General
Issued 19 October 2005
Resolved
Zippers on thermal protective aids are not in working order.
Construction/Loadline › Structures › Door
Issued 19 October 2005
No resolution recorded
Gaskets on the water tight door leading to the cargo control room have deteriorated. Must be rectified prior to next U.S. port after sailing foreign to the satisfaction of the attending class surveyor.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 October 2005
Resolved
Protective casing missing around light bulb on the starboard boat deck.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 19 October 2005
No resolution recorded
Non-conducting mats at feeder power panel missing. Must be rectified prior to next U.S. port after sailing foreign to the satisfaction of the attending class surveyor.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 19 October 2005
No resolution recorded
Fire extinguisher missing directly inside engine room.
Fire Fighting › Fire Main › Valves
Issued 19 October 2005
No resolution recorded
Forward firemain valve packing is excessivly leaking. Must be rectified prior to next U.S. port after sailing foreign to the satisfaction of the attending class surveyor.
Fire Fighting › Fire Hoses › Connections
Issued 19 October 2005
No resolution recorded
Forward fire hose is leaking at hydrant connection. Must be rectified prior to next U.S. port after sailing foreign to the satisfaction of the attending class surveyor.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 19 October 2005
Resolved
Deck scuppers missing.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 19 October 2005
Resolved
Containment drain plugs need to be replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 October 2005
No resolution recorded
Exposed wires at the remote temperature detector on the main engines cylinder head and low cylinder. Must be rectified prior to next U.S. port after sailing foreign to the satisfaction of the attending class surveyor.
Construction/Loadline › Structures › Door
Issued 10 February 2005
Resolved
weather tight doors gaskets and dogs worn, all doors.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 February 2005
Resolved
Safety railing in various locations main deck cargo area missing or wasted.
Fire Fighting › Fire Main › Condition
Issued 10 February 2005
Resolved
Fire main piping main deck various brackets missing and or wasted.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 February 2005
Resolved
safety railing in various locations main deck cargo area missing.
Construction/Loadline › Structures › Scuttle
Issued 10 February 2005
Resolved
hacth cargo generator room not weather tight.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 February 2005
Resolved
light cover winch pump room missing.
Construction/Loadline › Structures › Machinery Space Opening
Issued 10 February 2005
Resolved
elervator motor housing port side missing access cover.
Lifesaving › Lifefloat › Platform
Issued 10 February 2005
Resolved
davit boat deck portside not properly secured.
Construction/Loadline › Structures › Superstructure
Issued 10 February 2005
Resolved
Ladder and deck to exshaust stack wasted.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 February 2005
Resolved
light cover missing hospital.
Electrical › Lighting (service) › Outlet Box
Issued 10 February 2005
Resolved
electrical outlet shower room next to ships office/ exsposed not in a enclosed box.
Fire Fighting › Fire Hoses › Condition
Issued 10 February 2005
Resolved
various gaskets in hoses and nozzels worn and or wasted.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 February 2005
Resolved
light cover missing bath room portside main deck.
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 10 February 2005
Resolved
eebd expired engine control room.
Construction/Loadline › Hull › Hull Plating
Issued 10 February 2005
No resolution recorded
cement patchs starboard side engine room hull./ patchs to be remove and hull repaired in next drydock which is due in Dec '05 or Jan '06.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 February 2005
Resolved
main deck cargo area catwalks wasted.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 10 February 2005
Resolved
non-conducting mating missing rear of swicthboard.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 10 February 2005
Resolved
exshaust lagging wasted, main stack.
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 10 February 2005
Resolved
due to numerous deficiencies noted, reconized orginization to conduct external ism audit concerning maintenance procedures and reporting/record keeping.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 10 February 2005
Resolved
renew/replace ows and oil content meter to operative condition per regulation. vessel is to retain alloil slop/sludge on board and shall not pump anything overboard except at master's discrection due to an emergency.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 10 February 2005
Resolved
vessel must have licensed/ qualified crew members to fulfill its safe manning document. class to attend vessel to verify licences/training of replacements crew.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 24 August 2004
Resolved
Have class address and restify condition of ship's hospital space prior to next U.S. port to the satisfaction of class. PWSA 33USC1223(b)3
Construction/Loadline › Hull › Hull Plating
Issued 24 August 2004
Resolved
Make permanent repairs to soft patch breach in hull, port side #1 deep water ballast tank in way of #1 frame aft of collision bulkhead prior to next U.S. port.
Deck/Cargo › Ballast › Tank
Issued 24 August 2004
Resolved
Address use of #3 double bottom water ballast tanks for fuel storage, (Contradicts general arrangement plan) prior to next U.S. port.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 24 August 2004
Resolved
Make permanent repairs to gyrocompass in aft steering prior to next U.S. port.
Stability › Watertight Integrity › General
Issued 24 August 2004
Resolved
Have class conduct internal structural survey prior to next U.S. port after sailing foreign.
Construction/Loadline › Hull › Hull Plating
Issued 24 August 2004
Resolved
Make permanent repairs to hull shell plate on stern and address deep pitting prior to next U.S. port.
Stability › Water on Deck › General
Issued 24 August 2004
Resolved
Identify cause of port side listing (1+ degrees) prior to next U.S. port.
Construction/Loadline › Structures › Deck Plating
Issued 24 August 2004
Resolved
Make permanent repairs to forepeak breakwater bracing prior to next U.S. port.
Construction/Loadline › Structures › Deck Plating
Issued 24 August 2004
Resolved
Renew wasted anchor windlass platform prior to next U.S. port.
Construction/Loadline › Structures › Deck Plating
Issued 24 August 2004
Resolved
Renew wasted port fairlead pulley on focsle prior to next U.S. port.
Construction/Loadline › Structures › Deck Plating
Issued 24 August 2004
Resolved
Make permanent repairs to holed bulkhead aft of forepeak space prior to next U.S. port.
Lifesaving › Launching Appliances
Issued 24 July 2003
Resolved
Davit limit switch for port life boat inoperative,also port life boat davit brake not functioning properly.SOLAS 74 amend ch III reg 16 / SOLAS 60 reg 29 prior to departure, repair both and demonstrate operation to satisfaction of attending coast guard inspector.
Communications › Radio Communications
Issued 16 August 2002
Resolved
ONE OF TWO REQUIRED GMDSS RADIOS INOPERABLE. VESSEL IS EQUIPED WITH HF RADIO CAPABLE OF TRANSMITING/RECEIVING EMERGENCY SIGNALS AS REQUIRED PER SOLAS CHAPTER IX. LEGACY COMPONENT DESC: Satellite Communications Capability
Electrical › Lighting (emergency)
Issued 12 March 2002
Resolved
Emergency lighting in engine room not satisfactory. Lights in engine room lasted 20 minutes on emergency power. SOLAS 60 Reg 26. Provide class survey report of permanent repair and operation of emergency lighting. LEGACY COMPONENT DESC: Lighting Branch Circuit
Construction/Loadline › Penetrations
Issued 12 March 2002
Resolved
Improper penetrations (multiple) of A60 boundaries to engine room on poop deck and main deck. SOLAS 60 Reg 38. Provide class survey report of permanent repairs.
Electrical › Electrical Distribution System (service)
Issued 12 March 2002
Resolved
Multiple exposed wires throughout the vessel. SOLAS 60 Reg 27. Make permanent repairs to satisfaction of class. LEGACY COMPONENT DESC: Wiring
Accommodation/Occupational Safety › Occupational Safety
Issued 12 March 2002
Resolved
Emergency exit from engine room locked. SOLAS 60 CH II. Correct prior to ship's departure from port.
Operations/Management › Pollution
Issued 12 March 2002
Resolved
Excessive waste oil in engine room bilges. MARPOL 73/78 Annex I. Clean engine room bilges to satisfaction of attending USCG inspector. LEGACY COMPONENT DESC: Retention of Oily Mixture
Unknown
Issued 25 July 2001
Resolved
Provide OWS manual in the language of the ships crew.
Lifesaving
Issued 15 July 2001
Resolved
Clean and remove all oil from M/E and surrounding areas on deck and in bilges. To be cleande by 18 JUL 01 and checked prior to next U. S. port.
Engineering
Issued 15 July 2001
Resolved
Ensure to the satisfaction of class that the OWS has the ability to measurethe PPM of oil in the water discharged overboard prior to next U.S. port. OWS is not to be operated in U.S. waters. Retain all oily waste onboard until attended by class.
Fire Fighting
Issued 15 July 2001
Resolved
Firemain is holed anbd leaking near flange just FWD of superstructure and midway between superstructure and cargo control room. Repair to the satisfaction of class prior to 15 AUg 01.
Engineering
Issued 15 July 2001
Resolved
Fuel oil vent containments missing drain plugs in all areas. Provide new plugs and install prior to bunkering in U. S. waters. Fax invoice to MSO New Orleans [phone withheld].
Lifesaving
Issued 26 March 2001
Resolved
Vessel has excessive fuel and oil inbilges and has no where ro pump it due to the sldge tank being full. Sludge tank capicity 9.94 CM3, current level 8.00 CM3.
Lifesaving
Issued 20 March 2001
Resolved
INSTALL ELECTRICAL SAFETY MATTING FOR ALL SWITCHBOARDS THROUGHOUT VESSEL.
Construction/Loadline
Issued 20 March 2001
Resolved
REPLACE GASKETS ON WATERTIGHT DOORS.
Navigation
Issued 20 March 2001
Resolved
ARRANGE RUDDER ANGLE INDICATOR ON STEERING GEAR SO THAT IT CAN BE READ.
Lifesaving
Issued 20 March 2001
Resolved
REMOVE CHEMICALS AND PRESSURE BOTTLES FROM AFT STEERING, AND PROPERLY SECURE.
Lifesaving
Issued 20 March 2001
Resolved
MAKE REPAIRS TO DECK IN ENGINE CONTROL ROOM AFT OF SWITCHBOARD.
Engineering
Issued 20 March 2001
Resolved
REPAIR VENT HEAD PORT SIDE AFT MAIN DECK.
Engineering
Issued 20 March 2001
Resolved
INSTALL LOCK FOR OWS OVERBOARD DISCHARGE VALVE.
Lifesaving
Issued 20 March 2001
Resolved
REMOVE EXCESSIVE OIL FROM BILGES.
Electrical
Issued 20 March 2001
Resolved
REMOVE ALL FRAYED WIRE AND SECURE ALL EXPOSED JUNCTION BOXES AND BREAKERS.
Lifesaving
Issued 20 March 2001
Resolved
INSTALL PRIMARY BRACKETS FOR OXYGEN / ACTLENE BOTTLES.
Lifesaving
Issued 20 March 2001
Resolved
INSTALL LIMIT SWITCHES ON BOAT DAVITS.
Navigation
Issued 31 July 2000
Resolved
Provide tech report to Marine Safety Office for inoperable gyro compass prior to departure.
Navigation
Issued 28 June 2000
Resolved
PRIOR TO DEPARTURE, PROVIDE TECH REPORT FOR MASTER GYRO COMPASS.
Engineering
Issued 28 December 1999
Resolved
REPAIR FUEL OIL LEAK ON DECK COMPRESSOR._x001C_ SOLAS 74/78 11-1/26
Electrical
Issued 28 December 1999
Resolved
PROVIDE COVER TO #3 GENERATOR ELECTRICAL BOX. SOLAS 74 11-2/45.1.3
Fire Fighting
Issued 28 December 1999
Resolved
REPAIR SALT WATER LEAKS TO PIPING ON SUCTIONS TO BOTH FIREPUMPS.SOLAS 74 11/2-21
Engineering
Issued 28 December 1999
Resolved
REPAIR SALT WATER LEAK IN PIPING FOR X-CONNECT ON FIREPUMP AND MAIN ENGINE_x001C_SOLAS 74 11-2/21
Electrical
Issued 28 December 1999
Resolved
REPAIR SALT WATER LEAKS FOR SHIP SERVICE GENERATOR COOLING
Engineering
Issued 24 December 1998
Resolved
PROVIDE ON BOARD VESSEL ACCURATE SOUNDING TABLE/CHART TO THE SATISFACTION OF CLASS. MARPOL 73/78 ANNEX I/17.
Fire Fighting
Issued 24 December 1998
Resolved
PERFORM A FIRE DRILL TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR. SOLAS 74 (AMENDED) III/18.3.
Lifesaving
Issued 24 December 1998
Resolved
PERFORM AN ABANDON SHIP DRILL TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR. SOLAS 74 (AMENDED) III/18.3
Navigation
Issued 24 December 1998
Resolved
PROVIDE A REPORT FROM A COMPETENT SHORESIDE TECHNICIAN ATTESTING TO THE PROPER OPERATION OF THE ECHO DEPTH SOUNDER. SOLAS 74 9AMENDED) V/12(k).
Lifesaving
Issued 24 December 1998
Resolved
RENEW ALL LIFERING BUOYS AND LIFERING BUOY LIGHTS. SOLAS 74(AMENDED) III/19.2.
Documentation
Issued 24 December 1998
Resolved
PROVIDE ONBOARD VESSEL VALID IOPP CERTIFICATE FORM A. MARPOL73/78 ANNEX I/5.
Lifesaving
Issued 24 December 1998
Resolved
PROVIDE ON BOARD VESSEL PROPER LIFESAVING MAINTENANCE MANUAL IN ACCORDANCE WITH SOLAS 74 (AMENDED) III/19.3.1.
Fire Fighting
Issued 24 December 1998
Resolved
REPAIR/RENEW AS ORIGINAL DETERIORATED SECTION OF FIREMAIN PIPING AFT OF THEFORECASTLE BULKHEAD. SOLAS 74 (AMENDED) II-2/21.
Electrical
Issued 24 December 1998
Resolved
REPAIR/RENEW AS ORIGINAL SALTWATER DISCHARGE PIPING FOR THE GENERATORS IN WAY OF THE LOWER LEVEL ENGINEROOM STARBOARD SIDE. SOLAS 74 (AMENDED) I/11(a).
Engineering
Issued 24 December 1998
Resolved
REPAIR/RENEW AS ORIGINAL MISSING PIPE WHERE RUBBER HOSE IS CURRENTLY INSTALLED FROM THE PURIFIER DRAIN TANKS TO THE OWS MANIFOLD. PROVIDE CLASS REPORT APPROVING FINAL REPAIR. MARPOL 73/78 ANNEX I.
Fire Fighting
Issued 24 December 1998
Resolved
REPAIR/RENEW AS ORIGINAL THE FIREMAIN ISOLATION VALVE AND PROVE ITS PROPER OPERATION. SOLAS 74 (AMENDED) II-2/21.
Electrical
Issued 24 December 1998
Resolved
REPAIR/RENEW AS ORIGINAL DETERIORATED SALTWATER COOLING PIPING FOR THE GENERATORS IN WAY OF THE COOLING PUMP SUCTION. SOLAS 74 (AMENDED) I/11(a).
Fire Fighting
Issued 24 December 1998
Resolved
REPAIR/RENEW AS ORIGINAL DETERIORATED SECTION OF FIREMAIN IN WAY OF LOWER LEVEL ENGINEROOM, STARBOARD SIDE NEAR HYDRANT. SOLAS 74 (AMENDED) II-2/21.
Construction/Loadline
Issued 24 December 1998
Resolved
PROPERLY MARK LOADLINE ISSUING AUTHORITY ON THE PLIMSOLL MARK. ICLL 66 ANNEX I.
Fire Fighting
Issued 24 December 1998
Resolved
PROVIDE ON BOARD VESSEL THREE 2 1/2 HOSES AND TWO 1 1/2 HOSES TO REPLACE THE DETERIORATED ONES DISCOVERED DURING INSPECTION. SOLAS 74(AMENDED) II- 2/21.
Engineering
Issued 13 July 1998
Resolved
No oil transfer procedures on board. 33 CFR 155.750. vessel restricted from bunkering until completed.
Engineering
Issued 10 April 1998
Resolved
Affect permanent repairs to bunker piping soft patch on port side trim lineIAW 33 CFR 156.170(c)(4) prior to bunkering in next U.S. port.
Fire Fighting
Issued 10 April 1998
Resolved
Affect permanent repairs to fire main line soft patches (3) at stbd side_x001C_ lower engine room, main deck port side next to amidship house and center line forward of the amidship house IAW SOLAS II-2/4.
Documentation
Issued 10 April 1998
Resolved
Provide original Safe Manning document approved by flag state IAW SOLAS 74 V/13.
Lifesaving
Issued 10 April 1998
Resolved
Provide muster list for crew in both working languages IAW SOLAS 74 III/8.4prior to departure.
Lifesaving
Issued 10 April 1998
Resolved
Conduct satisfactory fire and abandon ship drills IAW SOLAS 74 III/18.3 prior to departure.
Lifesaving
Issued 10 April 1998
Resolved
Repair port side embarkation lighting at lifeboat station IAW SOLAS 60 III/19.
Lifesaving
Issued 10 April 1998
Resolved
Replace retroreflective tape on bottom of both lifeboats IAW SOLAS 74 III/30.2.7.
Documentation
Issued 10 April 1998
Resolved
Provide SOLAS training manual for crew in all mandatory locations IAW SOLAS74 III/51.
Documentation
Issued 10 April 1998
Resolved
Provide Company Action Plan to Master IAW STCW I/14 and A-I/14.
Lifesaving
Issued 10 April 1998
Resolved
Provide crew familiarization training with Company Action Plan IAW STCW VI/1 and A-VI/1.
Accommodation/Occupational Safety
Issued 10 April 1998
Resolved
Replace screws in overhead covers for galley vent dampers IAW SOLAS 74 II- 2/21.
Lifesaving
Issued 10 April 1998
Resolved
Repair hole in port lifeboat gunwale IAW SOLAS 74 III/19.2.
Fire Fighting
Issued 10 April 1998
Resolved
Replace smooth bore nozzles with dual purpose nozzles in engine room IAW SOLAS 60 65(iv).
Lifesaving
Issued 10 April 1998
Resolved
Provide flag state approval for fuel oil tank installation on starboard lifeboat IAW SOLAS 74 III/41.1.1 prior to next U.S. port entry.
Navigation
Issued 10 April 1998
Resolved
Provide complete Maneuvering Fact Sheet for bridge IAW 33 CFR 164.35 prior to next U.S. port entry.
Lifesaving
Issued 10 April 1998
Resolved
Install fire-retardant casing for starboard lifeboat engine IAW SOLAS 74 III/41.6.9 prior to next U.S. port entry.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National