ATLANTIC STAR

ATLANTIC STAR is a 1972 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2016, most recently in April 2026, along with 126 deficiencies and 4 casualty investigations between 2009 and 2016.

Records from 2009 to 2026. Most recent: inspection, 24 April 2026.

Built
1972
Last inspected
24 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDQ9576
Flag
UNITED STATES
Maury page id
psix-47378

Documentation record

Registered dimensions (L × B × D)85.1 ft × 21.0 ft × 8.8 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAMCRAFT INC · CROWN POINT, LA, UNITED STATES · built 1972
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCALABASH, NC
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 30 July 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

24 inspections, each with its date, unit and type; 126 deficiencies with the resolution recorded against each; 1 other recorded name, with years; 4 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 24

24 April 2026 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8357824
8 December 2025 Drydock Exam · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8278907
28 August 2025 In-Service Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8220398
11 April 2025 Internal Structural Exam · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8111644
15 August 2024 In-Service Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7982724
22 April 2024 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7899450
8 January 2024 Examination of Repairs · Drydock Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7846282
11 December 2023 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7837787
29 March 2023 Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7659563
4 January 2023 Examination of Repairs · Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7616353
28 February 2022 COI Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7403468
18 February 2022 Plan Review "T" Boat
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7398463
29 January 2021 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7132927
14 February 2020 DAPI Audit · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6909082
1 April 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6653339
17 January 2019 Examination of Repairs · Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6611570
7 November 2018 Drydock Extension
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6577144
9 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6505705
14 May 2018 Deficiency Check · Administrative Inspection · Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6413767
23 February 2017 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6093097
3 November 2016 Examination of Repairs · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6034699
10 August 2016 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5968638
18 May 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5885435
26 April 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5867471

Deficiency record · 126

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 April 2026 Resolved
A vessel that has a power driven fire pump must have piping, valves, and fittings in a fire main system must comply with subpart G, part 182. The fire pump pipe directly above the fire pump on the port side of the engine space had a pinhole leak when energized. Replace wasted piping.
Action required: 10 - Deficiency Rectified
Resolved 24 April 2026
Resolution: The piping was replaced with new fire main piping before the inspection was finished. Fire main was satisfactorily tested.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 24 April 2026 Resolved
Vertical or horizontal surfaces within 910 millimeters (3 feet) of cooking appliances must have an ASTM E-84 (incorporated by reference, see 46 CFR 175.600) flame spread rating of not more than 75. Galleys must be surrounded by B-15 Class fire boundaries near flat plate griddles, and open ranges with heating surfaces exceeding 121 °C (250 °F). The cooking appliance installed on the vessel is rated to 450 degrees F. Derate the cooking appliance so it does not exceed 250 °F or provide surfaces within 3 ' of the ccoking area that meet B-15 Class fire boundaries.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2026
Resolved 21 May 2026
Resolution: All surfaces adjacent to the cooking surfaces were covered with stainless panels.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 8 January 2024 Resolved
The replacement deck lights that have been installed are not properly wired/spliced; install junction boxes or proper watertight splices and hang the cable with metal ties every 24 inches prior to completion of dry dock.
Action required: 705 - Other - as specified
Resolved 22 March 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 December 2023 Resolved
The owner or managing operator shall make a vessel available for drydock examinations for a vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. The last Drydock Examination was conducted on 29NOV21. Vessel must undergo a credit Drydock Exam prior to carrying passengers for hire.
Action required: 705 - Other - as specified
Resolved 22 March 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 March 2023 Resolved
Move the lifering from behind the boarding ladder aft of the bridge so that it is available for immediate use.
Action required: 10 - Deficiency Rectified
Resolved 29 March 2023
Resolution: Lifering moved to the side of the house.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 29 March 2023 Resolved
Provide alcohol testing equipment for all crew.
Action required: 10 - Deficiency Rectified
Resolved 29 March 2023
Resolution: Alcohol test strips provided
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 29 March 2023 Resolved
Provide fuel screen for fuel vent.
Action required: 10 - Deficiency Rectified
Resolved 29 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 March 2023 Resolved
Provide battery covers for battery boxes in the engine room
Action required: 10 - Deficiency Rectified
Resolved 29 March 2023
Resolution: Battery covers installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 March 2023 Resolved
Provide a proper bilge pump with the required capacity to dewater the vessel bilges.
Action required: 10 - Deficiency Rectified
Resolved 29 March 2023
Resolution: New electric bilge pump installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 February 2022 Resolved
A lifejacket must be provided for each person the vessel is authorized to carry as indicated on the COI; (9) lifejackets were condemned due to deterioration, the vessel is restricted to the carriage of 125 total person until the full compliment of lifejackets are provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2022
Resolution: Owner procured new PFD's
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 28 February 2022 Resolved
Each life float must meet the specifications in accordance with the approval number 160.027; the life floats are not the approved color due to fading and the reflective tape is worn.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2022
Resolution: LF's have been repainted w/ [name withheld] approved paint
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 February 2022 Resolved
Nonconductive mats must be provided on the deck in front of each switchboard; there is no nonconductive mat in place.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2022
Resolution: Mat was added in front of SWBD
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 28 February 2022 Resolved
All hatches and openings in the hull must be kept tightly closed except when being used; the watertight door to the generator compartment is not fully operational and cannot be tightly closed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 March 2022
Resolution: Original door was re-worked
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 February 2022 Resolved
A voltage, amperage, and frequency meter shall be provided for each alternating current generator; the voltage meter for the #2 generator and the frequency meter for the switchboard are not operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 March 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 February 2022 Resolved
All electrical equipment and circuit must be clearly marked and identified; each individual circuit in the breaker panels in the galley and the generator compartment are not properly labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 February 2022 Resolved
A vessel must carry a first aid kit, approval number 160.041, or a kit with an equivalent contents; the existing kit is not of an approved type nor does it contain the equivalent inventory.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2022
Resolution: Missing items were added
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 28 February 2022 Resolved
The Master shall instruct each crew member as to the duties the crew member is expected to perform in an emergency and conduct drills at least once every three months; the normal crew for the vessel was not onboard at the time of the inspection, drill must be conducted in the presence of attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2022
Resolved 11 April 2022
Resolution: Fire and MOB drills conducted sat
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 28 February 2022 Resolved
Each watertight bulkhead must be capable of remaining watertight with a head of water to the top of the bulkhead; the aft bulkhead in the #1 void is not watertight due to improperly sealed cableway and a hole in the bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 28 February 2022 Resolved
Each pipe penetration in the hull below a line drawn parallel to at least 6 inches above the deepest load waterline must have a means to prevent water from entering the vessel if the pipe fractures or otherwise fails; a abandoned pipe penetration on the stbd side in the #1 void does not have a valve nor is it capped.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2022
Resolved 11 April 2022
Resolution: Pipe was inserted and welded shut
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 February 2022 Resolved
Each individual bilge line must be equipped with a check valve at some accessible point; the forepeak and the #1 void bilge lines are not so equipped.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2022
Resolution: Check valves were added to suction lines
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 February 2020 Resolved
The life floats required by 46 CFR 180.200 (c) shall be approved and meet the specifications of 46 CFR 160.027. Two of the life floats have deteriorated life lines and pendants, all of the life floats have deteriorated coatings; repair/maintenance the life floats to meet specified standards.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 February 2020 Resolved
The contents of the first aid kit must be stowed in a watertight container, not all of the required inventory is in a watertight container; provide a watertight container for the remainder of the required contents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 14 February 2020 Resolved
The hull structures must comply with the appropriate design standards; the fuel fill fitting connection to the deck plating IWO the lazarette is deteriorated and must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 25 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 February 2020 Resolved
Exhaust piping which exceeds 150° F must be suitably insulated to prevent injuries; the exhaust piping elbow on the starboard generator is not properly insulated; install lagging.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 February 2020 Resolved
Conductors shall be provided with overcurrent protection in accordance with the current carrying capacity of the conductor; the conductor for the 12 volt emergency lighting system is not have overcurrent protection installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 February 2020 Resolved
Portable fire extinguishers must be inspected and maintained IAW NFPA 10; the fire extinguisher in the engine compartment, IWO the escape hatch,has a deteriorated hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 February 2020 Resolved
The fire pump is corroded and the extent of deterioration is unknown; clean the corrosion and make available for further inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 February 2020 Resolved
Electrical conductors shall be installed and maintained in a safe and proper operating condition for the service in which they are intended; there are numerous dead end wires located behind the starboard side paneling in the rod room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 February 2020 Resolved
All unsafe practices and hazardous situations shall be corrected; a 2"X4" wooden beam has been put in place to support the HVAC ducting in the rod room and it is wedged on top of an electrical box; remove the hazard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 February 2020 Resolved
Electrical conductors shall be installed and maintained in a safe operating condition for the service for which they are intended; the wires for the engine control modules, on the aft bulkhead of the rod room, are chaffing and the insulation is worn.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 14 February 2020 Resolved
All unsafe practices and hazardous situations shall be corrected; the bilges have debris which during the bilge pump test created an unsafe condition by clogging the bilge suction; clean bilges of all debris.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 25 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 February 2020 Resolved
Electrical systems shall be installed in accordance with standards that will result in a vessel that is reasonably safe; the electrical panel in the galley is not properly labeled; label all circuits.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 14 February 2020 Resolved
The vessel shall be maintained in a serviceable and sanitary condition; the sewage holding tank is deteriorated and no longer serviceable or sanitary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2020
Resolved 25 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2020 Resolved
The steering system shall be maintained in a suitable condition and fit for service; there is a hydraulic leak in the tubing IWO the rod room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 February 2020 Resolved
The main propulsion systems shall be maintained in a serviceable condition; the cooling water hose for the port main engine is chaffed and is no longer serviceable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 February 2020 Resolved
A life jacket must be provided for each passenger carried on board the vessel; the COI requires 132 life jackets, the vessel currently has 93, the vessel is restricted to the carriage of 93 total person (90 passengers & 3 crew) until the full compliment of life jackets have been provided.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2020
Resolved 2 March 2020
Resolution: Additional jackets purchased.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 April 2019 Resolved
One length of hose shall be provided for each fire hydrant. 02 fire hoses had leaks during operational testing, replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 April 2019 Resolved
All vessels shall be provided with satisfactory arrangement for draining watertight compartments. Bilge suction for #1 void beneath galley is unable to be obtained. Identify cause, prove proper suction.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2019
Resolution: Crew demonstrated proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 April 2019 Resolved
All vessels shall be provided with satisfactory arrangement for draining watertight compartments. Bilge suction for #1 void beneath galley is unable to be obtained. Properly label bilge pumping arrangements.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2019 Resolved
All electrical installations shall be to the satisfaction of the [name withheld] void breaker panels: remove wire nuts, secure face plate and properly and properly identify all breakers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 April 2019 Resolved
Placards containing instructions for the donning and use of life jackets aboard must be posted in conspicous places regularly accessible and visible to crew and passengers. Post instructions which are legible for each type of lifejacket carried aboard.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 April 2019 Resolved
A vessel must carry a first aid kit approved/equal to series 160.041. Provide first aid kit with required contents.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 April 2019 Resolved
Vessel on oceans route must carry 06 hand red distress signals. Vessel is missing one red, provide.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2019
Resolution: Crewmember found additional red distress signal stored in separate location.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 April 2019 Resolved
Provide FCC Safety Certificate
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 April 2019 Resolved
Provide Radiotelephone Bridge to Bridge Certificate
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 1 April 2019 Resolved
Update AIS to show correct vessel type.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 February 2020
Resolution: AIS verified.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 April 2019 Resolved
A vessel must carry adequate and up to date pubs. Update Coast Pilot [name withheld], Tide Table, Current Tables, and charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 April 2019 Resolved
Provide alcohol test swabs.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 1 April 2019 Resolved
Emergency instructions containing actions to be taken in the event of a fire, heavy weather, or man overboard shall be mounted at the operating station and the master and crew shall be familiar with their content. Provide.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 1 April 2019 Resolved
Post Oil Discharge Placard near bilge system.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 1 April 2019 Resolved
Post Garbage Discharge Placard in galley.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 April 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 February 2020
Resolution: Bracket has been varified as replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 April 2019 Resolved
Flexible hoses shall be fabricated of suitable material. Replace generator fuel oil return hoses - 01 port, 02 standby - with SAE J-1942 Hoses.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 April 2019 Resolved
Each fuel tank shall be fitted with a vent pipe. Stbd fuel vent screen is deteriorated. Replace with flame screen that is corrosion resistant of at least 30x30 mesh.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 April 2019 Resolved
Aux machinery shall be suitable in type and design for the purpose intended. Provide cap for oil drain lines.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2019 Resolved
Non-conducting mats or grating shall be provided on deck in front and read. Provide mats at main switchboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2019 Resolved
Conductors for lighting shall be protected from overcurrent. The emergency lighting circuit originating in the generator space is not protected. Provide overcurrent protection.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
Resolution: Emergency lights removed; not required item.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2019 Resolved
All conductors shall be of the stranded type. Replace wire run from alarm to float switch in #2 void.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 April 2019 Resolved
Aux machinery shall be suitable in type and design for purpose intended. Secure alarm windlass filter housing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 1 April 2019 Resolved
Clean oil from generator space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 1 April 2019 Resolved
All enclosed spaces shall be ventilated. provide goose neck vent plugs throughout.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 1 April 2019 Resolved
Each life float must have name and capacity marked. Mark name and capacity on small life float.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2019 Resolved
All wiring and cables shall be suitable for marine environment. LED fixture on fantail is not secure and remove electric outlet spliced into light circuit in accommodation spaces.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 April 2019 Resolved
An adult life jacket must be provided for each person carried on board. Condemned 37 life jackets due to deteriorated conditions. Passenger count reduced to 95 until replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 February 2020
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018 Resolved
The vessel is currently not broadcasting a Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 18 February 2020
Resolution: Corrected
Communications › Radio Communications › EPIRB
Issued 14 May 2018 Resolved
The EPIRB hydrostatic release is expired and must be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: New hydro placed in service.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 May 2018 Resolved
The remote fuel shut off valve is binding; make repairs as necessary to insure proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: The valve was tested remotly and operates smoothly.
Lifesaving › Hand Flares › Expired
Issued 14 May 2018 Resolved
Numerous flares are expired; replace flares as necessary and insure proper amount are on hand.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: New in-date flares have been placed onboard.
Stability › Watertight Integrity › General
Issued 14 May 2018 Resolved
The gasket on the engine room escape hatch is deteriorated; replace the gasket and properly adjust hatch to insure water tight integrity.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: The slide pins at the hinged side for the hatch were stuck and not allowing the hatch to sit flush. This has been corrected, also the individual dog nuts are to be changed with ny-lock to prevent them from backing off.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 14 May 2018 Resolved
The are several holes in the collision bulkhead due to the replacement of a hydraulic tank; repair holes to insure water tight integrity.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: The holes have been sealed with 5200 and bolts with the exception of two which fall directly on a upright stiffener, these will be addressed at upcoming DD.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 14 May 2018 Resolved
The electrical breaker for the bilge pump trips during each use; determine the cause and make the necessary repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2018
Resolution: The pump motor has been replaced in kind with a 50 C motor.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 May 2018 Resolved
The COI is not posted; properly post the COI as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: COI posted.
Documentation › Certificates/Documents › Stability Letter
Issued 14 May 2018 Resolved
The stability letter is not posted; properly post the stability letter as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Stability letter posted.
Documentation › Logs/Records › Drug Test Records
Issued 14 May 2018 Resolved
The Master is not on the current list of employees for the drug program; have the Master added to the employers consortium prior to operating the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 14 May 2018 Resolved
The operator did not have emergency instructions for the vessel; provide and post emergency instructions as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Emergency instruction have been posted in the passenger compartment.
Documentation › Markings/Placards › Lifejacket Placard
Issued 14 May 2018 Resolved
The life jacket donning placard could not be found; provide and post as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: A lifejacket donning placard has been posted in the passenger compartment.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 14 May 2018 Resolved
The vessel is not equipped with an emergency broadcast placard at the radio station; provide the vessel with same and post as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Provided O/O with emergency broadcast placard decal.
Navigation › Piloting/Steering › Magnetic Compass
Issued 14 May 2018 Resolved
The compass light is not functioning; determine cause and repair as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Compass light bulb was changed and tested sat.
Lifesaving › Lifefloat › Serviceable
Issued 14 May 2018 Resolved
One of the small 8 person life floats is no longer serviceable due to deterioration; the life float must be replaced. The passenger count is reduced accordingly until a new float is installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 July 2018
Resolution: The operator took a reduction in passengers in lieu of replacing the float; COI to be amended accordingly.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 14 May 2018 Resolved
The water light batteries have not been changed in accordance with the manufacturers instructions; replace all batteries.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: The lights have been changed and tested sat.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 14 May 2018 Resolved
One of the life float water lights is deteriorated and the strobe lens is yellow; replace the subject light.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Float light has been renewed with a new light.
Lifesaving › Lifefloat › Painter
Issued 14 May 2018 Resolved
One sea painter is not the correct diameter for the required breaking strength; replace the sea painter with the correct size.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Sea painter changed out to line the same size as existing painters.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 May 2018 Resolved
Two of the ring buoys have multiple names on them; remove the improper markings and insure the vessel name is properly marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: The previous names have been made unreadable.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 14 May 2018 Resolved
The reflective material on numerous life jackets is deteriorated; renew with reflective tape as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Reflective material replaced with SOLAS tape as directed.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 14 May 2018 Resolved
Two life jacket lights do not have batteries; provide batteries as needed. The passenger count is reduced accordingly until the lights are operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Batteries placed in lifejacket lights.
Fire Fighting › Firemans Outfit › Axe
Issued 14 May 2018 Resolved
The fire axe is stowed in a storage locker; properly mount the fire axe in the vicinity of the operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Fire axe moved to operating station.
Engineering › Fuel Oil Service System › Hose
Issued 14 May 2018 Resolved
The fuel hoses for the generators are not SAE J1942 type hoses; install approved type hoses or provide fire sleeves of approved type.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 July 2018
Resolution: Hoses have been replaced with SAE J-1942 type hose and proper fittings.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2018 Resolved
A 12-volt circuit has been installed for electric reels without approval of the OCMI; provide plans to include amperage draw, cable size, and length of run.
Action required: 705 - Other - as specified
Due 30 November 2018
Resolved 18 February 2020
Resolution: Circuits have been removed from the power source and bulkhead penetrations sealed; permanent repairs shall be carried out during the next dry dock.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2018 Resolved
There are circuits originating at the stbd generator batteries which are unidentified; trace out and identify the wires and the equipment powered by said wiring. Provide detailed information regarding these circuits.
Action required: 705 - Other - as specified
Due 30 November 2018
Resolved 18 February 2020
Resolution: Circuit have been disconnected from the power source; permanent repairs are to be completed during the next dry dock.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2018 Resolved
The wire run powering the live well pump is not an approved type wire; replace wire with UL approved boat cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Wire run changed out with UL boat cable however it is not connected to the disconnect switch.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 14 May 2018 Resolved
The supply piping for the three shaft seals have plastic fitting incorporated into the installation; remove plastic fittings and replace with metallic fittings.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Corrected with brass fittings.
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 May 2018 Resolved
The battery installation in the engine compartment has wing nuts on the terminals; replace the wing nuts with standard nuts.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Wire nuts changed out.
Engineering › Fuel Oil Service System › Filter
Issued 14 May 2018 Resolved
The fuel filters for the main engines have plastic petcocks; remove and replace with metallic petcocks that will accept a plug.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 July 2018
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 May 2018 Resolved
The front cover of the electrical panel in the crew space is loose; properly fasten the panel cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Corrected as required.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 May 2018 Resolved
The breaker panel in the galley has open spaces were breakers are missing and the panel cover is loose; provide blanks for open slots and secure the panel cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Corrected as required.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 14 May 2018 Resolved
The bracket for the fire extinguisher in the passenger accommodation space does not have a proper fastening device; provide the extinguisher with a belly strap.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Deck/Cargo › Mooring/Anchoring › Winch
Issued 14 May 2018 Resolved
There is a hydraulic leak in the anchor winch supply line in the #2 void; make repairs as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: The fittings were tightened and no leak was present at time of def ck.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 14 May 2018 Resolved
Due to the installation of a new anchor windlass motor, provide documentation regarding the proper breaker size for the new motor.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 July 2018
Resolution: Documentation provided indicates that the breaker must be 30 Amps and the wire gauge must be 6 AWG.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 14 May 2018 Resolved
There are no markings on the air receiver to indicate an ASME certification; provide proof that the air receiver is ASME certified.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Air receiver has been removed.
Electrical › Electric Supply System (service) › Cable
Issued 27 February 2017 Resolved
Remove romex wire from the panel in the engine room and replace with approved boat cable.
Due 26 March 2017
Resolved 24 March 2017
Fire Fighting › Fire Main › Pressure
Issued 27 February 2017 Resolved
Replace the pressure gauge on the fire pump.
Due 26 March 2017
Resolved 24 March 2017
Engineering › Fuel Oil Service System › Valve
Issued 27 February 2017 Resolved
Provide new fuel valve handle on center main engine due to broken handle.
Due 26 March 2017
Resolved 24 March 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 February 2017 Resolved
Remove excess wires from the batteries in the engine room, install terminal bus as needed.
Due 26 March 2017
Resolved 24 March 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 February 2017 Resolved
Remove and replace wire nut with butt connector on stbd main engine alternator wire.
Due 26 March 2017
Resolved 24 March 2017
Construction/Loadline › Structures › Transverse Bulkhead
Issued 27 February 2017 Resolved
Make repairs to the hole in the fwd watertight bulkhead in the engine room. Plans for repairs must be submitted and approved before making repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2017
Resolution: A repair proposal was submitted and approved to soft patch the repair with a small aluminum plate and 5200. Repair will remain untill next scheduled drydock.
Engineering › Fuel Oil Service System › Valve
Issued 27 February 2017 Resolved
Provide fuel shut off for the generator fuel tank.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2017
Resolution: Valve installed and tested.
Engineering › Bilge Water Management System › Piping
Issued 27 February 2017 Resolved
Replace the piece of hose for the bilge/fire pump intake with approved hose (SAE J-1942).
Due 26 March 2017
Resolved 24 March 2017
Construction/Loadline › Structures › Transverse Bulkhead
Issued 27 February 2017 Resolved
Remove A/C drain line from bulkhead penetration and either valve or cap off pipe.
Due 26 March 2017
Resolved 24 March 2017
Resolution: Penetration capped off.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 February 2017 Resolved
Provide light covers and globes for lights as needed.
Due 26 March 2017
Resolved 24 March 2017
Electrical › Electrical Distribution System (service) › Cable
Issued 27 February 2017 Resolved
Remove all non approved wires in the generator room and replace with approved boat cable, noted two.
Due 26 March 2017
Resolved 24 March 2017
Electrical › Electric Generation Source (service) › Panelboard
Issued 27 February 2017 Resolved
Label breaker for the #1 generator on the main switchboard.
Due 26 March 2017
Resolved 24 March 2017
Electrical › Electric Generation Source (service) › Panelboard
Issued 27 February 2017 Resolved
Replace the power available light for the #1 generator on the switchboard.
Due 26 March 2017
Resolved 24 March 2017
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 27 February 2017 Resolved
Provide a flame screen (30 x 30 mesh)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2017
Resolution: Flame screen properly installed.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 27 February 2017 Resolved
Provide two (2) additional adult life jackets, the vessel is restricted to 130 total persons until corrected.
Due 26 March 2017
Resolved 24 March 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 23 February 2017 Resolved
Program VHF radio with MMSI number.
Due 26 March 2017
Resolved 24 March 2017
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 23 February 2017 Resolved
Prove operation of single side band radio.
Due 26 March 2017
Resolved 24 March 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 February 2017 Resolved
Repair bilge alarm in below deck storage compartment. Install bilge alarm in the steering compartment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2017
Resolution: Proper repairs affected and tested.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 February 2017 Resolved
Replace forward masthead light bulb with proper type of bulb.
Due 26 March 2017
Resolved 24 March 2017
Engineering › Bilge Water Management System › Piping
Issued 23 February 2017 Resolved
Replace the piece of hose in the bilge pipe located in the forward storage compartment with approved type hose (SAE J-1942).
Due 26 March 2017
Resolved 24 March 2017
Engineering › Bilge Water Management System › Not Operational
Issued 10 August 2016 Resolved
Prove proper operation of high level alarm in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2016
Resolved 10 August 2016
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 August 2016 Resolved
At next dry-dock, renew the strainer for the port main diesel engine.
Condition: Improper/Lack of Maintenance
Due 31 December 2016
Resolved 7 November 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 26 April 2016 Resolved
B-I fire extinguisher on bridge not properly mounted.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 10 August 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 26 April 2016 Resolved
Vessel did not have a DSC equipped radio installed.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 10 August 2016
Electrical › Electrical Distribution System (service) › Panelboard
Issued 26 April 2016 Resolved
Electrical panel in lazarette, port side, needs to be remounted.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 10 August 2016
Engineering › Bilge Water Management System › Not Operational
Issued 26 April 2016 Resolved
Bilge suction to forepeak was inoperable.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 10 August 2016
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 26 April 2016 Resolved
Excessive diesel fuel noted in vessels bilges beneath racor's.
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 26 April 2016

Casualty record · 4

2 August 2009Routine · role: Involved in a Marine Casualty · activity 3555193
14 April 2011Routine · role: Subject to Marine Inspection · 1 dead · activity 4003219
15 January 2013Routine · role: Involved in a Marine Casualty · activity 4517037
18 May 2016Routine · role: Involved in a Marine Casualty · activity 5885435
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

PASTIME PRINCESS (2009–2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.