MAURY USCG vessel records Sign in
← All vessels

ATLANTIC STAR

ATLANTIC STAR is a 1972 passenger vessel (inspected). The Coast Guard has recorded 98 inspections since 1981, most recently in April 2026, along with 297 deficiencies and 4 casualty investigations between 2009 and 2016.

Records from 1981 to 2026. Most recent: inspection, 24 April 2026.

Built
1972
Last inspected
24 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ9576
Flag
UNITED STATES
367772450
Maury page id
psix-47378

Inspections, by type

…with no type recorded14
Years with a record 40 calendar years (1981–2026)
The 98 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)85.1 ft × 21.0 ft × 8.8 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAMCRAFT INC · CROWN POINT, LA, UNITED STATES · built 1972
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCALABASH, NC
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 30 July 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

EX365MMSI 367772450 · active · exemption · granted 7 July 2026, expires 7 July 2030
WDQ9576MMSI 367772450 · active · compulsorily equipped · granted 7 May 2026, expires 7 May 2036
WDJ3896MMSI 367772450 · cancelled · compulsorily equipped · granted 10 February 2017, cancelled 30 April 2026
WDE7632MMSI 366711000 · expired · compulsorily equipped · granted 18 February 2009, cancelled 20 April 2019
WBT4670MMSI 366711000 · expired · compulsorily equipped · granted 17 February 1998, cancelled 19 July 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 98

24 April 2026 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8357824
8 December 2025 Drydock Exam · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8278907
28 August 2025 In-Service Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8220398
11 April 2025 Internal Structural Exam · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8111644
15 August 2024 In-Service Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7982724
22 April 2024 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7899450
8 January 2024 Examination of Repairs · Drydock Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7846282
11 December 2023 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7837787
29 March 2023 Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7659563
4 January 2023 Examination of Repairs · Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7616353
28 February 2022 COI Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7403468
18 February 2022 Plan Review "T" Boat
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7398463
29 January 2021 Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7132927
14 February 2020 DAPI Audit · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6909082
1 April 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6653339
17 January 2019 Examination of Repairs · Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6611570
7 November 2018 Drydock Extension
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6577144
9 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6505705
14 May 2018 Deficiency Check · Administrative Inspection · Periodic Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6413767
23 February 2017 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6093097
3 November 2016 Examination of Repairs · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6034699
10 August 2016 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5968638
18 May 2016 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5885435
26 April 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5867471
10 June 2014 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4885064
1 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4237026
1 December 2010 Examination of Repairs · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3901813
23 March 2010 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3693941
7 January 2010 Type not recorded
No type recorded · Station Ponce De Leon Inlet · USCG Southeast District (CGD-SE) · Activity 3684449
6 March 2009 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3428705
6 February 2009 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3414556
19 November 2008 Hull Examination · In-Service Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3366099
9 May 2008 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3204436
16 April 2008 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3185559
10 March 2008 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3161292
18 October 2007 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3082137
10 October 2007 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3077884
3 October 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3071854
25 June 2007 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2973363
24 May 2007 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2939265
16 April 2007 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2907266
6 September 2006 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2770854
4 May 2006 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2640185
3 April 2006 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2615176
8 December 2005 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2548258
4 October 2005 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2507760
13 September 2005 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2491036
22 March 2005 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2316804
9 April 2004 MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2040923
25 February 2004 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2012620
24 March 2003 Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1761823
10 September 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1674030
21 March 2002 Hull Examination · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1495442
28 March 2001 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1460504
31 July 2000 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 819898
10 April 2000 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1457774
7 April 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 817116
28 March 2000 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1063829
28 March 2000 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1423315
13 April 1999 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 789586
8 March 1999 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 801044
3 March 1999 Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1468902
3 December 1998 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1470191
16 March 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1108559
10 March 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 785575
5 March 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1096679
4 December 1996 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 876480
14 March 1996 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 885480
6 March 1996 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 885792
29 March 1995 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1146692
15 March 1995 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1140322
13 December 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1169610
4 May 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1024925
21 April 1994 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 112963
20 July 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1155152
25 May 1993 COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1156022
22 March 1993 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1147901
17 February 1993 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1359485
13 November 1992 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1137896
30 April 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 949836
13 November 1991 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1247968
29 July 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1243922
22 July 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 939618
7 June 1991 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 903061
5 November 1990 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1227665
13 June 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 916884
29 May 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1214426
5 February 1990 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1218662
15 December 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1243279
14 November 1989 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 910246
2 December 1988 Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1207683
17 October 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1198445
13 September 1988 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1043418
24 December 1987 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1316892
20 November 1987 Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1027591
3 April 1986 COI Inspection · Credit Drydock
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1308796
28 July 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 973896
2 June 1981 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1277134

Deficiency record · 297

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 April 2026 Resolved
A vessel that has a power driven fire pump must have piping, valves, and fittings in a fire main system must comply with subpart G, part 182. The fire pump pipe directly above the fire pump on the port side of the engine space had a pinhole leak when energized. Replace wasted piping.
Action required: 10 - Deficiency Rectified
Resolved 24 April 2026
Resolution: The piping was replaced with new fire main piping before the inspection was finished. Fire main was satisfactorily tested.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 24 April 2026 Resolved
Vertical or horizontal surfaces within 910 millimeters (3 feet) of cooking appliances must have an ASTM E-84 (incorporated by reference, see 46 CFR 175.600) flame spread rating of not more than 75. Galleys must be surrounded by B-15 Class fire boundaries near flat plate griddles, and open ranges with heating surfaces exceeding 121 °C (250 °F). The cooking appliance installed on the vessel is rated to 450 degrees F. Derate the cooking appliance so it does not exceed 250 °F or provide surfaces within 3 ' of the ccoking area that meet B-15 Class fire boundaries.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2026
Resolved 21 May 2026
Resolution: All surfaces adjacent to the cooking surfaces were covered with stainless panels.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 8 January 2024 Resolved
The replacement deck lights that have been installed are not properly wired/spliced; install junction boxes or proper watertight splices and hang the cable with metal ties every 24 inches prior to completion of dry dock.
Action required: 705 - Other - as specified
Resolved 22 March 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 December 2023 Resolved
The owner or managing operator shall make a vessel available for drydock examinations for a vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. The last Drydock Examination was conducted on 29NOV21. Vessel must undergo a credit Drydock Exam prior to carrying passengers for hire.
Action required: 705 - Other - as specified
Resolved 22 March 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 March 2023 Resolved
Move the lifering from behind the boarding ladder aft of the bridge so that it is available for immediate use.
Action required: 10 - Deficiency Rectified
Resolved 29 March 2023
Resolution: Lifering moved to the side of the house.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 29 March 2023 Resolved
Provide alcohol testing equipment for all crew.
Action required: 10 - Deficiency Rectified
Resolved 29 March 2023
Resolution: Alcohol test strips provided
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 29 March 2023 Resolved
Provide fuel screen for fuel vent.
Action required: 10 - Deficiency Rectified
Resolved 29 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 March 2023 Resolved
Provide battery covers for battery boxes in the engine room
Action required: 10 - Deficiency Rectified
Resolved 29 March 2023
Resolution: Battery covers installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 March 2023 Resolved
Provide a proper bilge pump with the required capacity to dewater the vessel bilges.
Action required: 10 - Deficiency Rectified
Resolved 29 March 2023
Resolution: New electric bilge pump installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 February 2022 Resolved
A lifejacket must be provided for each person the vessel is authorized to carry as indicated on the COI; (9) lifejackets were condemned due to deterioration, the vessel is restricted to the carriage of 125 total person until the full compliment of lifejackets are provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2022
Resolution: Owner procured new PFD's
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 28 February 2022 Resolved
Each life float must meet the specifications in accordance with the approval number 160.027; the life floats are not the approved color due to fading and the reflective tape is worn.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2022
Resolution: LF's have been repainted w/ [name withheld] approved paint
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 February 2022 Resolved
Nonconductive mats must be provided on the deck in front of each switchboard; there is no nonconductive mat in place.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2022
Resolution: Mat was added in front of SWBD
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 28 February 2022 Resolved
All hatches and openings in the hull must be kept tightly closed except when being used; the watertight door to the generator compartment is not fully operational and cannot be tightly closed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 March 2022
Resolution: Original door was re-worked
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 February 2022 Resolved
A voltage, amperage, and frequency meter shall be provided for each alternating current generator; the voltage meter for the #2 generator and the frequency meter for the switchboard are not operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 March 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 February 2022 Resolved
All electrical equipment and circuit must be clearly marked and identified; each individual circuit in the breaker panels in the galley and the generator compartment are not properly labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 February 2022 Resolved
A vessel must carry a first aid kit, approval number 160.041, or a kit with an equivalent contents; the existing kit is not of an approved type nor does it contain the equivalent inventory.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2022
Resolution: Missing items were added
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 28 February 2022 Resolved
The Master shall instruct each crew member as to the duties the crew member is expected to perform in an emergency and conduct drills at least once every three months; the normal crew for the vessel was not onboard at the time of the inspection, drill must be conducted in the presence of attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2022
Resolved 11 April 2022
Resolution: Fire and MOB drills conducted sat
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 28 February 2022 Resolved
Each watertight bulkhead must be capable of remaining watertight with a head of water to the top of the bulkhead; the aft bulkhead in the #1 void is not watertight due to improperly sealed cableway and a hole in the bulkhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 28 February 2022 Resolved
Each pipe penetration in the hull below a line drawn parallel to at least 6 inches above the deepest load waterline must have a means to prevent water from entering the vessel if the pipe fractures or otherwise fails; a abandoned pipe penetration on the stbd side in the #1 void does not have a valve nor is it capped.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2022
Resolved 11 April 2022
Resolution: Pipe was inserted and welded shut
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 February 2022 Resolved
Each individual bilge line must be equipped with a check valve at some accessible point; the forepeak and the #1 void bilge lines are not so equipped.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 March 2022
Resolution: Check valves were added to suction lines
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 February 2020 Resolved
The life floats required by 46 CFR 180.200 (c) shall be approved and meet the specifications of 46 CFR 160.027. Two of the life floats have deteriorated life lines and pendants, all of the life floats have deteriorated coatings; repair/maintenance the life floats to meet specified standards.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 February 2020 Resolved
The contents of the first aid kit must be stowed in a watertight container, not all of the required inventory is in a watertight container; provide a watertight container for the remainder of the required contents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 14 February 2020 Resolved
The hull structures must comply with the appropriate design standards; the fuel fill fitting connection to the deck plating IWO the lazarette is deteriorated and must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 25 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 February 2020 Resolved
Exhaust piping which exceeds 150° F must be suitably insulated to prevent injuries; the exhaust piping elbow on the starboard generator is not properly insulated; install lagging.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 February 2020 Resolved
Conductors shall be provided with overcurrent protection in accordance with the current carrying capacity of the conductor; the conductor for the 12 volt emergency lighting system is not have overcurrent protection installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 February 2020 Resolved
Portable fire extinguishers must be inspected and maintained IAW NFPA 10; the fire extinguisher in the engine compartment, IWO the escape hatch,has a deteriorated hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 February 2020 Resolved
The fire pump is corroded and the extent of deterioration is unknown; clean the corrosion and make available for further inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 February 2020 Resolved
Electrical conductors shall be installed and maintained in a safe and proper operating condition for the service in which they are intended; there are numerous dead end wires located behind the starboard side paneling in the rod room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 February 2020 Resolved
All unsafe practices and hazardous situations shall be corrected; a 2"X4" wooden beam has been put in place to support the HVAC ducting in the rod room and it is wedged on top of an electrical box; remove the hazard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 February 2020 Resolved
Electrical conductors shall be installed and maintained in a safe operating condition for the service for which they are intended; the wires for the engine control modules, on the aft bulkhead of the rod room, are chaffing and the insulation is worn.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 14 February 2020 Resolved
All unsafe practices and hazardous situations shall be corrected; the bilges have debris which during the bilge pump test created an unsafe condition by clogging the bilge suction; clean bilges of all debris.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 25 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 February 2020 Resolved
Electrical systems shall be installed in accordance with standards that will result in a vessel that is reasonably safe; the electrical panel in the galley is not properly labeled; label all circuits.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 14 February 2020 Resolved
The vessel shall be maintained in a serviceable and sanitary condition; the sewage holding tank is deteriorated and no longer serviceable or sanitary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2020
Resolved 25 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2020 Resolved
The steering system shall be maintained in a suitable condition and fit for service; there is a hydraulic leak in the tubing IWO the rod room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 February 2020 Resolved
The main propulsion systems shall be maintained in a serviceable condition; the cooling water hose for the port main engine is chaffed and is no longer serviceable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 2 March 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 February 2020 Resolved
A life jacket must be provided for each passenger carried on board the vessel; the COI requires 132 life jackets, the vessel currently has 93, the vessel is restricted to the carriage of 93 total person (90 passengers & 3 crew) until the full compliment of life jackets have been provided.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2020
Resolved 2 March 2020
Resolution: Additional jackets purchased.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 April 2019 Resolved
One length of hose shall be provided for each fire hydrant. 02 fire hoses had leaks during operational testing, replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 April 2019 Resolved
All vessels shall be provided with satisfactory arrangement for draining watertight compartments. Bilge suction for #1 void beneath galley is unable to be obtained. Identify cause, prove proper suction.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2019
Resolution: Crew demonstrated proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 April 2019 Resolved
All vessels shall be provided with satisfactory arrangement for draining watertight compartments. Bilge suction for #1 void beneath galley is unable to be obtained. Properly label bilge pumping arrangements.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2019 Resolved
All electrical installations shall be to the satisfaction of the [name withheld] void breaker panels: remove wire nuts, secure face plate and properly and properly identify all breakers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 April 2019 Resolved
Placards containing instructions for the donning and use of life jackets aboard must be posted in conspicous places regularly accessible and visible to crew and passengers. Post instructions which are legible for each type of lifejacket carried aboard.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 April 2019 Resolved
A vessel must carry a first aid kit approved/equal to series 160.041. Provide first aid kit with required contents.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 April 2019 Resolved
Vessel on oceans route must carry 06 hand red distress signals. Vessel is missing one red, provide.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2019
Resolution: Crewmember found additional red distress signal stored in separate location.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 April 2019 Resolved
Provide FCC Safety Certificate
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 April 2019 Resolved
Provide Radiotelephone Bridge to Bridge Certificate
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 1 April 2019 Resolved
Update AIS to show correct vessel type.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 February 2020
Resolution: AIS verified.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 April 2019 Resolved
A vessel must carry adequate and up to date pubs. Update Coast Pilot [name withheld], Tide Table, Current Tables, and charts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 April 2019 Resolved
Provide alcohol test swabs.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 1 April 2019 Resolved
Emergency instructions containing actions to be taken in the event of a fire, heavy weather, or man overboard shall be mounted at the operating station and the master and crew shall be familiar with their content. Provide.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 1 April 2019 Resolved
Post Oil Discharge Placard near bilge system.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 1 April 2019 Resolved
Post Garbage Discharge Placard in galley.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 April 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 February 2020
Resolution: Bracket has been varified as replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 April 2019 Resolved
Flexible hoses shall be fabricated of suitable material. Replace generator fuel oil return hoses - 01 port, 02 standby - with SAE J-1942 Hoses.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 April 2019 Resolved
Each fuel tank shall be fitted with a vent pipe. Stbd fuel vent screen is deteriorated. Replace with flame screen that is corrosion resistant of at least 30x30 mesh.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 April 2019 Resolved
Aux machinery shall be suitable in type and design for the purpose intended. Provide cap for oil drain lines.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2019 Resolved
Non-conducting mats or grating shall be provided on deck in front and read. Provide mats at main switchboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2019 Resolved
Conductors for lighting shall be protected from overcurrent. The emergency lighting circuit originating in the generator space is not protected. Provide overcurrent protection.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
Resolution: Emergency lights removed; not required item.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2019 Resolved
All conductors shall be of the stranded type. Replace wire run from alarm to float switch in #2 void.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 April 2019 Resolved
Aux machinery shall be suitable in type and design for purpose intended. Secure alarm windlass filter housing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 1 April 2019 Resolved
Clean oil from generator space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 1 April 2019 Resolved
All enclosed spaces shall be ventilated. provide goose neck vent plugs throughout.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 1 April 2019 Resolved
Each life float must have name and capacity marked. Mark name and capacity on small life float.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2019 Resolved
All wiring and cables shall be suitable for marine environment. LED fixture on fantail is not secure and remove electric outlet spliced into light circuit in accommodation spaces.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 April 2019 Resolved
An adult life jacket must be provided for each person carried on board. Condemned 37 life jackets due to deteriorated conditions. Passenger count reduced to 95 until replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 February 2020
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018 Resolved
The vessel is currently not broadcasting a Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 18 February 2020
Resolution: Corrected
Communications › Radio Communications › EPIRB
Issued 14 May 2018 Resolved
The EPIRB hydrostatic release is expired and must be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: New hydro placed in service.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 May 2018 Resolved
The remote fuel shut off valve is binding; make repairs as necessary to insure proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: The valve was tested remotly and operates smoothly.
Lifesaving › Hand Flares › Expired
Issued 14 May 2018 Resolved
Numerous flares are expired; replace flares as necessary and insure proper amount are on hand.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: New in-date flares have been placed onboard.
Stability › Watertight Integrity › General
Issued 14 May 2018 Resolved
The gasket on the engine room escape hatch is deteriorated; replace the gasket and properly adjust hatch to insure water tight integrity.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: The slide pins at the hinged side for the hatch were stuck and not allowing the hatch to sit flush. This has been corrected, also the individual dog nuts are to be changed with ny-lock to prevent them from backing off.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 14 May 2018 Resolved
The are several holes in the collision bulkhead due to the replacement of a hydraulic tank; repair holes to insure water tight integrity.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2018
Resolution: The holes have been sealed with 5200 and bolts with the exception of two which fall directly on a upright stiffener, these will be addressed at upcoming DD.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 14 May 2018 Resolved
The electrical breaker for the bilge pump trips during each use; determine the cause and make the necessary repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2018
Resolution: The pump motor has been replaced in kind with a 50 C motor.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 May 2018 Resolved
The COI is not posted; properly post the COI as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: COI posted.
Documentation › Certificates/Documents › Stability Letter
Issued 14 May 2018 Resolved
The stability letter is not posted; properly post the stability letter as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Stability letter posted.
Documentation › Logs/Records › Drug Test Records
Issued 14 May 2018 Resolved
The Master is not on the current list of employees for the drug program; have the Master added to the employers consortium prior to operating the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 14 May 2018 Resolved
The operator did not have emergency instructions for the vessel; provide and post emergency instructions as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Emergency instruction have been posted in the passenger compartment.
Documentation › Markings/Placards › Lifejacket Placard
Issued 14 May 2018 Resolved
The life jacket donning placard could not be found; provide and post as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: A lifejacket donning placard has been posted in the passenger compartment.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 14 May 2018 Resolved
The vessel is not equipped with an emergency broadcast placard at the radio station; provide the vessel with same and post as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Provided O/O with emergency broadcast placard decal.
Navigation › Piloting/Steering › Magnetic Compass
Issued 14 May 2018 Resolved
The compass light is not functioning; determine cause and repair as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Compass light bulb was changed and tested sat.
Lifesaving › Lifefloat › Serviceable
Issued 14 May 2018 Resolved
One of the small 8 person life floats is no longer serviceable due to deterioration; the life float must be replaced. The passenger count is reduced accordingly until a new float is installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 July 2018
Resolution: The operator took a reduction in passengers in lieu of replacing the float; COI to be amended accordingly.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 14 May 2018 Resolved
The water light batteries have not been changed in accordance with the manufacturers instructions; replace all batteries.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: The lights have been changed and tested sat.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 14 May 2018 Resolved
One of the life float water lights is deteriorated and the strobe lens is yellow; replace the subject light.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Float light has been renewed with a new light.
Lifesaving › Lifefloat › Painter
Issued 14 May 2018 Resolved
One sea painter is not the correct diameter for the required breaking strength; replace the sea painter with the correct size.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Sea painter changed out to line the same size as existing painters.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 May 2018 Resolved
Two of the ring buoys have multiple names on them; remove the improper markings and insure the vessel name is properly marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: The previous names have been made unreadable.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 14 May 2018 Resolved
The reflective material on numerous life jackets is deteriorated; renew with reflective tape as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Reflective material replaced with SOLAS tape as directed.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 14 May 2018 Resolved
Two life jacket lights do not have batteries; provide batteries as needed. The passenger count is reduced accordingly until the lights are operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Batteries placed in lifejacket lights.
Fire Fighting › Firemans Outfit › Axe
Issued 14 May 2018 Resolved
The fire axe is stowed in a storage locker; properly mount the fire axe in the vicinity of the operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Fire axe moved to operating station.
Engineering › Fuel Oil Service System › Hose
Issued 14 May 2018 Resolved
The fuel hoses for the generators are not SAE J1942 type hoses; install approved type hoses or provide fire sleeves of approved type.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 July 2018
Resolution: Hoses have been replaced with SAE J-1942 type hose and proper fittings.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2018 Resolved
A 12-volt circuit has been installed for electric reels without approval of the OCMI; provide plans to include amperage draw, cable size, and length of run.
Action required: 705 - Other - as specified
Due 30 November 2018
Resolved 18 February 2020
Resolution: Circuits have been removed from the power source and bulkhead penetrations sealed; permanent repairs shall be carried out during the next dry dock.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2018 Resolved
There are circuits originating at the stbd generator batteries which are unidentified; trace out and identify the wires and the equipment powered by said wiring. Provide detailed information regarding these circuits.
Action required: 705 - Other - as specified
Due 30 November 2018
Resolved 18 February 2020
Resolution: Circuit have been disconnected from the power source; permanent repairs are to be completed during the next dry dock.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 May 2018 Resolved
The wire run powering the live well pump is not an approved type wire; replace wire with UL approved boat cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Wire run changed out with UL boat cable however it is not connected to the disconnect switch.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 14 May 2018 Resolved
The supply piping for the three shaft seals have plastic fitting incorporated into the installation; remove plastic fittings and replace with metallic fittings.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Corrected with brass fittings.
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 May 2018 Resolved
The battery installation in the engine compartment has wing nuts on the terminals; replace the wing nuts with standard nuts.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Wire nuts changed out.
Engineering › Fuel Oil Service System › Filter
Issued 14 May 2018 Resolved
The fuel filters for the main engines have plastic petcocks; remove and replace with metallic petcocks that will accept a plug.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 July 2018
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 May 2018 Resolved
The front cover of the electrical panel in the crew space is loose; properly fasten the panel cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Corrected as required.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 May 2018 Resolved
The breaker panel in the galley has open spaces were breakers are missing and the panel cover is loose; provide blanks for open slots and secure the panel cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Corrected as required.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 14 May 2018 Resolved
The bracket for the fire extinguisher in the passenger accommodation space does not have a proper fastening device; provide the extinguisher with a belly strap.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Deck/Cargo › Mooring/Anchoring › Winch
Issued 14 May 2018 Resolved
There is a hydraulic leak in the anchor winch supply line in the #2 void; make repairs as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: The fittings were tightened and no leak was present at time of def ck.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 14 May 2018 Resolved
Due to the installation of a new anchor windlass motor, provide documentation regarding the proper breaker size for the new motor.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 July 2018
Resolution: Documentation provided indicates that the breaker must be 30 Amps and the wire gauge must be 6 AWG.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 14 May 2018 Resolved
There are no markings on the air receiver to indicate an ASME certification; provide proof that the air receiver is ASME certified.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 May 2018
Resolution: Air receiver has been removed.
Electrical › Electric Supply System (service) › Cable
Issued 27 February 2017 Resolved
Remove romex wire from the panel in the engine room and replace with approved boat cable.
Due 26 March 2017
Resolved 24 March 2017
Fire Fighting › Fire Main › Pressure
Issued 27 February 2017 Resolved
Replace the pressure gauge on the fire pump.
Due 26 March 2017
Resolved 24 March 2017
Engineering › Fuel Oil Service System › Valve
Issued 27 February 2017 Resolved
Provide new fuel valve handle on center main engine due to broken handle.
Due 26 March 2017
Resolved 24 March 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 February 2017 Resolved
Remove excess wires from the batteries in the engine room, install terminal bus as needed.
Due 26 March 2017
Resolved 24 March 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 February 2017 Resolved
Remove and replace wire nut with butt connector on stbd main engine alternator wire.
Due 26 March 2017
Resolved 24 March 2017
Construction/Loadline › Structures › Transverse Bulkhead
Issued 27 February 2017 Resolved
Make repairs to the hole in the fwd watertight bulkhead in the engine room. Plans for repairs must be submitted and approved before making repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2017
Resolution: A repair proposal was submitted and approved to soft patch the repair with a small aluminum plate and 5200. Repair will remain untill next scheduled drydock.
Engineering › Fuel Oil Service System › Valve
Issued 27 February 2017 Resolved
Provide fuel shut off for the generator fuel tank.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2017
Resolution: Valve installed and tested.
Engineering › Bilge Water Management System › Piping
Issued 27 February 2017 Resolved
Replace the piece of hose for the bilge/fire pump intake with approved hose (SAE J-1942).
Due 26 March 2017
Resolved 24 March 2017
Construction/Loadline › Structures › Transverse Bulkhead
Issued 27 February 2017 Resolved
Remove A/C drain line from bulkhead penetration and either valve or cap off pipe.
Due 26 March 2017
Resolved 24 March 2017
Resolution: Penetration capped off.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 February 2017 Resolved
Provide light covers and globes for lights as needed.
Due 26 March 2017
Resolved 24 March 2017
Electrical › Electrical Distribution System (service) › Cable
Issued 27 February 2017 Resolved
Remove all non approved wires in the generator room and replace with approved boat cable, noted two.
Due 26 March 2017
Resolved 24 March 2017
Electrical › Electric Generation Source (service) › Panelboard
Issued 27 February 2017 Resolved
Label breaker for the #1 generator on the main switchboard.
Due 26 March 2017
Resolved 24 March 2017
Electrical › Electric Generation Source (service) › Panelboard
Issued 27 February 2017 Resolved
Replace the power available light for the #1 generator on the switchboard.
Due 26 March 2017
Resolved 24 March 2017
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 27 February 2017 Resolved
Provide a flame screen (30 x 30 mesh)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2017
Resolution: Flame screen properly installed.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 27 February 2017 Resolved
Provide two (2) additional adult life jackets, the vessel is restricted to 130 total persons until corrected.
Due 26 March 2017
Resolved 24 March 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 23 February 2017 Resolved
Program VHF radio with MMSI number.
Due 26 March 2017
Resolved 24 March 2017
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 23 February 2017 Resolved
Prove operation of single side band radio.
Due 26 March 2017
Resolved 24 March 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 February 2017 Resolved
Repair bilge alarm in below deck storage compartment. Install bilge alarm in the steering compartment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2017
Resolution: Proper repairs affected and tested.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 February 2017 Resolved
Replace forward masthead light bulb with proper type of bulb.
Due 26 March 2017
Resolved 24 March 2017
Engineering › Bilge Water Management System › Piping
Issued 23 February 2017 Resolved
Replace the piece of hose in the bilge pipe located in the forward storage compartment with approved type hose (SAE J-1942).
Due 26 March 2017
Resolved 24 March 2017
Engineering › Bilge Water Management System › Not Operational
Issued 10 August 2016 Resolved
Prove proper operation of high level alarm in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2016
Resolved 10 August 2016
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 August 2016 Resolved
At next dry-dock, renew the strainer for the port main diesel engine.
Condition: Improper/Lack of Maintenance
Due 31 December 2016
Resolved 7 November 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 26 April 2016 Resolved
B-I fire extinguisher on bridge not properly mounted.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 10 August 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 26 April 2016 Resolved
Vessel did not have a DSC equipped radio installed.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 10 August 2016
Electrical › Electrical Distribution System (service) › Panelboard
Issued 26 April 2016 Resolved
Electrical panel in lazarette, port side, needs to be remounted.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 10 August 2016
Engineering › Bilge Water Management System › Not Operational
Issued 26 April 2016 Resolved
Bilge suction to forepeak was inoperable.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 10 August 2016
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 26 April 2016 Resolved
Excessive diesel fuel noted in vessels bilges beneath racor's.
Action required: 705 - Other - as specified
Due 26 April 2016
Resolved 26 April 2016
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 25 June 2014 Resolved
Issued requirement to update COD with Coastwise endorsement
Due 25 August 2014
Resolved 25 June 2014
Lifesaving › Lifejacket/PFD (Type V) › Lights
Issued 11 June 2014 Resolved
Renew expired life jacket lights. Vessel restricted to Limited Coastwise (less than 20 miles from safe refuge) until installed.
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 2 July 2014
Resolution: Provided photos of new chem. lights with expiration date of April 2018
Electrical › Electrical Distribution System (service) › Junction Box
Issued 11 June 2014 Resolved
properly mount junction box in compartment 3, starboard side, aft.
Due 18 June 2014
Resolved 25 June 2014
Resolution: Junction box is properly secured.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 11 June 2014 Resolved
Replace electrical box cover behind/under pilothouse console
Due 18 June 2014
Resolved 25 June 2014
Resolution: Electrical box cover has been replaced.
Electrical › Electrical Distribution System (service) › Switch
Issued 11 June 2014 Resolved
Re-secure cut off switch box located on the forward bulkhead in the engine room.
Due 18 June 2014
Resolved 25 June 2014
Resolution: Cut off switch box has been removed.
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 11 June 2014 Resolved
Renew starboard main engine raw water hose.
Due 2 July 2014
Resolved 2 July 2014
Resolution: Provided with photo of new main engine raw water hose installed, double clamped, on starboard engine.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 June 2014 Resolved
Renew cracked float light. Extended due date, float light in on order and to be delivered by 20 Jun 2014.
Due 20 June 2014
Resolved 25 June 2014
Resolution: Float light has been replaced.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 June 2014 Resolved
Replace float light batteries with correct type (non-spring).
Due 18 June 2014
Resolved 25 June 2014
Resolution: Correct float light batteries are installed.
Lifesaving › Lifejacket/PFD (Type V) › Retroreflective Material
Issued 11 June 2014 Resolved
Renew reflective tape or replace life jacket on 35 PFD's.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2014
Resolution: Renewed 35 PFD''''s prior to departure of inspectors.
Lifesaving › Lifejacket/PFD (Type V) › Condition
Issued 11 June 2014 Resolved
Renew 02 Child and 01 Adult PFD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2014
Resolution: Replaced missing PFD''''s.
Stability › Watertight Integrity › General
Issued 11 June 2014 Resolved
Renew missing valve handle in compartment #3 starboard side, aft.
Due 18 June 2014
Resolved 25 June 2014
Resolution: Valve has been replaced.
Construction/Loadline › Hull › Longitudinal Frame
Issued 11 June 2014 Resolved
Properly repair 02 cracked frames at the aft bulkhead of MSD space (in overhead). To be completed next dry dock due December 2014.
Due 6 December 2014
Resolved 2 December 2014
Resolution: Welder repaired cracked frames at the aft bulkhead of the MSD space.
Construction/Loadline › Structures › Door
Issued 2 December 2010 Resolved
Repair top dog on hatch to generator/steering compartment.
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 20 January 2011
Construction/Loadline › Penetrations › Pipe Flange
Issued 1 December 2010 Resolved
Renew cap on through-hull fitting in forward starboard E/R with that of an approved type material.
Action required: 705 - Other - as specified
Due 2 December 2010
Resolved 13 December 2010
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 December 2010 Resolved
Ensure proper operation of fuel shut-off valve and mark in appropriately visible location.
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 20 January 2011
Fire Fighting › Fire Hydrants › Condition
Issued 1 December 2010 Resolved
Renew valve handle IWO port side fire station.
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 20 January 2011
Communications › Public Address System › Loudspeaker
Issued 1 December 2010 Resolved
Ensure all loose speakers are securely mounted to brackets.
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 20 January 2011
Accommodation/Occupational Safety › Potable Water System › General
Issued 1 December 2010 Resolved
Ensure grey water drain line is adequately supported.
Action required: 705 - Other - as specified
Due 2 January 2011
Resolved 20 January 2011
Construction/Loadline › Hull › Side Shell
Issued 1 December 2010 Resolved
Grind/clean up blistered spots noted in paint on port side hull and make available for inspection.
Action required: 705 - Other - as specified
Due 2 December 2010
Resolved 3 December 2010
Resolution: Examined side shell. Cleared this item, issued item # 8.
Construction/Loadline › Hull › Side Shell
Issued 1 December 2010 Resolved
Crop and renew side shell hull plate IWO wastage observed on port side as discussed. Once plaing is removed, make available for examination by USCG Marine Inspector prior to proceeding.
Action required: 705 - Other - as specified
Due 2 December 2010
Resolved 13 December 2010
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 23 March 2010 Resolved
Provide evidence of 60 minute supervisory EAP training.
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 22 April 2010
Lifesaving › Lifebuoys › Serviceable
Issued 23 March 2010 Resolved
Replace float light battery, lifeline, and install vessel name on starboard lifering.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2010
Lifesaving › Lifefloat › Lifeline
Issued 23 March 2010 Resolved
Replace all white polypropylene line on lifesaving equipment with dark color or UV resistant line.
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 22 April 2010
Electrical › Lighting (service) › Lighting Fixture
Issued 23 March 2010 Resolved
Repair broken port side forward light mount bracket.
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 22 April 2010
Lifesaving › Lifefloat › Painter
Issued 23 March 2010 Resolved
Install lifefloat painter so that it feeds freely from the top of the spool.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2010
Resolution: Corrected on the spot.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 March 2010 Resolved
Remove exposed wiring on starboard side upper deck.
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 22 April 2010
Electrical › Electric Generation Source (emergency) › Conductor
Issued 23 March 2010 Resolved
Remove wingnuts and install standard nuts on battery terminal connections.
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 22 April 2010
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 23 March 2010 Resolved
Install cover and properly label breaker panel in crew space.
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 22 April 2010
Engineering › Fuel Oil Service System › Valve
Issued 23 March 2010 Resolved
Label emergency fuel shut-off valve.
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 23 March 2010
Resolution: Corrected on the spot.
Construction/Loadline › Penetrations › Pipe Flange
Issued 23 March 2010 Resolved
Remove PVC plug and install metallic plug on MSD sea valve termination in MSD space.
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 22 April 2010
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 March 2010 Resolved
Replace line and repair mount on lifering aft of pilothouse.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2010
Communications › Audible Communications › Bell
Issued 23 March 2010 Resolved
Provide 7.8 " bell.
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 22 April 2010
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 23 March 2010 Resolved
Establish a lifesaving equipment maintenance program and provide evidence of required recurring lifesaving maintenance.
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 22 April 2010
Construction/Loadline › Structures › Superstructure
Issued 23 March 2010 Resolved
Provide proper replacement of starboard aft pilothouse window.
Action required: 705 - Other - as specified
Due 23 April 2010
Resolved 22 April 2010
Electrical › Lighting (service) › Lighting Fixture
Issued 6 February 2009 Resolved
Install proctective cover for light fixture, located in the SSDG space.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 6 March 2009
Resolution: Corrected
Electrical › Lighting (service) › Outlet Box
Issued 6 February 2009 Resolved
Replace wasted Junction Box for flood lights.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 6 March 2009
Resolution: Corrected
Electrical › Lighting (emergency) › Lighting Fixture
Issued 6 February 2009 Resolved
Repair visual indicator for engine room bilge high water level alarm.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 6 March 2009
Resolution: Corrected
Construction/Loadline › Structures › Deck Plating
Issued 6 February 2009 Resolved
Complete weld repair, located top deck aft.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 6 March 2009
Resolution: Corrected
Navigation › Piloting/Steering › Coast Guard Light List
Issued 6 February 2009 Resolved
Provide current light list, coast pilot and tides tables.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 6 March 2009
Resolution: Corrected
Documentation › Certificates/Documents › FCC SSL
Issued 6 February 2009 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2009
Resolution: Owner of vessel provided proof of FCC prior to CG departure.
Lifesaving › Hand Flares › Expired
Issued 6 February 2009 Resolved
Replace 4 expired signal flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2009
Resolution: Owner of vessel purchased new signal flares, prior to CG departure.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 6 February 2009 Resolved
Replace all life water-float lines, with correct size (3/8).
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 6 March 2009
Resolution: Corrected
Engineering › Lubricating Oil Service System › Hose
Issued 6 February 2009 Resolved
Replace wasted hydraulic fittings, located on winch.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 6 March 2009
Resolution: corrected
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 6 February 2009 Resolved
Replace cracked life-float water light.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 6 March 2009
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 February 2009 Resolved
Remove dead-end wiring under control console.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 6 March 2009
Resolution: corrected
Operations/Management › Passenger Operations › Safety Orientation
Issued 6 February 2009 Resolved
Post max passengers allowed sign on upper deck.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 6 March 2009
Resolution: corrected
Lifesaving › Lifefloat › Serviceable
Issued 16 April 2008 Resolved
Three 25-man liferafts are to be repaired using approved [name withheld] repair kits NLT 23APR08.
Action required: 705 - Other - as specified
Due 23 April 2008
Resolved 9 May 2008
Resolution: Corrected
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 April 2008 Resolved
Vessel is to replace (10) unserviceable type I adult PFD's prior to sailing.
Action required: 705 - Other - as specified
Due 16 April 2008
Resolved 9 May 2008
Resolution: Corrected
Lifesaving › Lifebuoys › Serviceable
Issued 16 April 2008 Resolved
Grab lines for the vessels ring buoy located on the starboard side of the vessels pilot house are to be renewed NLT 23APR08.
Action required: 705 - Other - as specified
Due 23 April 2008
Resolved 9 May 2008
Resolution: Corrected
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 16 April 2008 Resolved
Ladder leading to foward hold is to be refastened NLT 23APR08.
Action required: 705 - Other - as specified
Due 23 April 2008
Resolved 9 May 2008
Resolution: Corrected
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 10 October 2007 Resolved
Provide prior to next Annual examination, provide General Arrangement Plan and Electrical Line Drawing Plan showing current arrangements and electrical details.
Condition: Unknown
Due 24 March 2008
Resolved 16 April 2008
Resolution: Corrected
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 October 2007 Resolved
Provide positive closure valves on all three MDE cooling water overboard discharges which are approximately 5" above the waterline.
Condition: Improper Installation
Due 22 October 2007
Resolved 22 October 2007
Resolution: Valves were installed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 10 October 2007 Resolved
THIS DEF IS A CONTINUATION OF #5, FROM SECTOR JACKSONVILLE'S HULL EXAMINATION. (Make permanent repair to E/R watertight bulkhead, aft, starboard, where wasted and make penetrations for hydraulic steering lines watertight. (Temporary repairs were allowed by [name withheld] for two trips, 11OCT and 13OCT.)
Condition: Unknown
Due 22 October 2007
Resolved 17 October 2007
Resolution: Repairs were made
Construction/Loadline › Hull › Stiffener
Issued 8 October 2007 Resolved
Replace side longitudinal (1 port and 1 stbd) in fore peak.
Action required: 705 - Other - as specified
Due 22 October 2007
Resolved 17 October 2007
Resolution: Sistered longitudinal
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 October 2007 Resolved
Secure all loose wiring in junction box in fwd part of engien room; overhead port side.
Action required: 705 - Other - as specified
Due 8 October 2007
Resolved 10 October 2007
Resolution: Cleared by [name withheld] of MSD Port Canaveral.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 October 2007 Resolved
Properly weld gunnels in bow area; several cracks near connection points.
Action required: 705 - Other - as specified
Due 22 October 2007
Resolved 22 October 2007
Resolution: Cracks were backgouged and welded
Construction/Loadline › Hull › Bottom Plating
Issued 8 October 2007 Resolved
Make fuel oil tank in steerign ear room ready for entry/inspection. Bottom of tank is part of the hull; internals could not be inspected.
Action required: 705 - Other - as specified
Due 30 October 2007
Resolved 17 October 2007
Resolution: Tank was opened and internally examined
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 October 2007 Resolved
Crop and renew aft engien room bulkhead - stbd side. Area is badly pitted.
Action required: 705 - Other - as specified
Due 22 October 2007
Resolved 10 October 2007
Resolution: Temporary repairs, as in watertight integrity and fire stop where applied which was accepted by [name withheld] as a short term repair. Permanent repairs as outlined above will still need to be made.
Construction/Loadline › Hull › Stiffener
Issued 8 October 2007 Resolved
Crop and renew side longitudinal in crawl space on port side in crew space.
Action required: 705 - Other - as specified
Due 22 October 2007
Resolved 22 October 2007
Resolution: Allowed to sister the longitudinal.
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 October 2007 Resolved
Double clamp connection on keel cooler pipe in crew space.
Action required: 705 - Other - as specified
Due 22 October 2007
Resolved 17 October 2007
Resolution: Double clamps were provided
Construction/Loadline › Structures › Door
Issued 8 October 2007 Resolved
Replace gasket and handles on the door to the steering gear room.
Action required: 705 - Other - as specified
Due 24 March 2008
Resolved 28 February 2008
Resolution: Received photos via e-mail attesting to the replacement of the missing handles, previous visit had witnessed new gasket.
Engineering › Bilge Water Management System › Piping
Issued 8 October 2007 Resolved
Properly repair bilge line in crew space. Line currently consists of aluminum pipe, rubber hose, and PVC.
Action required: 705 - Other - as specified
Due 22 October 2007
Resolved 10 October 2007
Resolution: Cleared by [name withheld] of MSD Port Canaveral.
Engineering › Freshwater System (air cooling) › Drainage
Issued 3 October 2007 Resolved
Replace AC pipe through hull fitting w/proper fitting.
Action required: 705 - Other - as specified
Due 22 October 2007
Resolved 22 October 2007
Resolution: Metallic pipe and valve added at the penetration.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 24 May 2007 Resolved
Due to installation of numerous electrical devices onboard, owner has been required to complete a new electrical load analysis IAW 46 CFR 177.202(b)(4)(ix) and submit for approval.
Action required: 705 - Other - as specified
Due 24 July 2007
Resolved 25 June 2007
Resolution: Received correspondence from owner stating all new electrical appliances were replacement in kind. Cleared requirement to have new load analysis conducted.
Engineering › Bilge Water Management System › Not Operational
Issued 16 April 2007 Resolved
Vessel is to rewire improperly connected bilge alarm in the foward and passenger comparment bilges and prove proper operation of the same.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 24 May 2007
Resolution: New bilge alarms installed and tested.
Construction/Loadline › Penetrations › Weld
Issued 16 April 2007 Resolved
Vessel is permanently repair overboard gray water discharge line, where holed and now repaired with soft patch.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 24 May 2007
Resolution: temp repairs completed.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 16 April 2007 Resolved
AC electrical distribution panel in the air conditioning space is to be properly secured to the bulkhead. Additionally, all breakers are to be labeled and proper blanks installed as needed.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 24 May 2007
Resolution: completed.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 16 April 2007 Resolved
Emergency escapes from the lazarette and engine compartment are to be properly labeled. Additionally, the fuel cut-off and hatch leading to the lower crew compartment shall also be properly labeled.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 24 May 2007
Resolution: completed.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 16 April 2007 Resolved
Excessive and unused materials through out the vessel that are greatly increasing the vessels fire load are to be removed.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 24 May 2007
Resolution: completed.
Engineering › Bilge Water Management System › Not Operational
Issued 3 April 2006 Resolved
Vessel is to repair and prove proper operation of all bilge high water alarms.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 4 May 2006
Resolution: Corrected
Lifesaving › Lifefloat › Approval
Issued 3 April 2006 Resolved
Vessel is to replace 4 (3 man) lifefloats with CG approved equipment.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 4 May 2006
Resolution: Corrected
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 3 April 2006 Resolved
Engine compartment emergency escape hatch is to be marked as such.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 4 May 2006
Resolution: Corrected
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 3 April 2006 Resolved
Upper deck is to be marked with the maximum number of passengers allowed.
Action required: 705 - Other - as specified
Due 3 May 2006
Resolved 4 May 2006
Resolution: Corrected
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 7 October 2005 Resolved
Portable CO2 fire extinguisher in the forward storage compartment is to be hydrostatically pressure tested or renewed.
Action required: 705 - Other - as specified
Due 7 November 2005
Resolved 31 October 2005
Resolution: CO2 extinguisher was replace with new unit.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 7 October 2005 Resolved
All portable fire extinguishers onboard are to be properly mounted prior to operating.
Action required: 705 - Other - as specified
Due 7 November 2005
Resolved 31 October 2005
Resolution: All fire extinguishers were mounted.
Communications › Radio Communications › EPIRB
Issued 7 October 2005 Resolved
Vessels EPIRB is to be re-registered to reflect change in ownership.
Action required: 705 - Other - as specified
Due 7 November 2005
Resolved 31 October 2005
Resolution: EPIRB was re-registered.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 October 2005 Resolved
All dead ended wires throughout the vessel are to be removed or properly dead ended.
Action required: 705 - Other - as specified
Due 7 November 2005
Resolved 31 October 2005
Resolution: Wires removed.
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 7 October 2005 Resolved
Batteries located in the pilothouse for radios are to be placed in appropriate battery boxes.
Action required: 705 - Other - as specified
Due 7 November 2005
Resolved 31 October 2005
Resolution: Batteries mounted properly.
Engineering › Bilge Water Management System › Interface Detector
Issued 7 October 2005 Resolved
Bilge alarm panel on bridge is to be properly labeled.
Action required: 705 - Other - as specified
Due 7 November 2005
Resolved 31 October 2005
Resolution: Labeled.
Lifesaving › Lifefloat › Retroreflective Material
Issued 22 March 2005 Resolved
Replace SOLAS tape as needed on STBD inboard lifefloat.
Due 29 March 2005
Resolved 24 March 2005
Resolution: Replaced Tape as Necessary.
Lifesaving › Lifefloat › Lifeline
Issued 22 March 2005 Resolved
Replace grab rail on both inboard lifefloats.
Due 29 March 2005
Resolved 24 March 2005
Resolution: Replaced Grab Lines as Necessary.
Accommodation/Occupational Safety › Cooking Systems › CNG System Requirements
Issued 22 March 2005 Resolved
Clean or Replace filter on galley hood.
Due 29 March 2005
Resolved 24 March 2005
Resolution: Replaced Same.
Engineering › Bilge Water Management System › Not Operational
Issued 22 March 2005 Resolved
Demonstrate proper operation of bilge high level alarms. While underway, conduct visual inspection of all voids with the hull fittings every 30 mins until proper operation is proved to attending CG MI.
Due 29 March 2005
Resolved 24 March 2005
Resolution: Op Check of Bilge Alarms all Sat.
Lifesaving › Buoyant Smoke Signals
Issued 9 April 2004 Resolved
Vsl missing 2 orange smoke flares.
Due 15 April 2004
Resolved 9 April 2004
Resolution: Received fax receipt clearing def.
Engineering › Bilge Water Management System
Issued 9 April 2004 Resolved
Inop Engine Room Bilge High Level Alarm light LEGACY COMPONENT DESC: High Level Alarm
Due 15 April 2004
Resolved 9 April 2004
Resolution: Received statement from master clearing def.
Engineering
Issued 9 April 2004 Resolved
Leaking hydraulic oil galley space. LEGACY COMPONENT DESC: Hydraulic Steering Hose
Due 15 April 2004
Resolved 9 April 2004
Resolution: Resolved by fax statement.
Documentation
Issued 10 April 2000 Resolved
Provide [name withheld] a copy of stability letter, reflecting the vessel's deck modifications, Vessel restricted from commercial operations until proof of a valid stability letter is provided to NY OCMI.
Condition: Unknown
Due 27 April 2000
Resolved 20 April 2000
Documentation
Issued 10 April 2000 Resolved
Provide Approved plans for work done, including extending and widening of deck, re-piping of the firemain, and ventilation to the engine room, to theNew York [name withheld] 46 CFR 176.700.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Engineering
Issued 3 March 1999 Resolved
Install insulation on port and stbd generator exhaust piping.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Engineering
Issued 3 March 1999 Resolved
Install steel or equivalent piping for raw water discharge to overboard 0n 3 main engines as per 46 CFR 182.40-5, 182.40-10 and 46 CFR 56.60-25. Piping installed is PVC.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Accommodation/Occupational Safety
Issued 3 March 1999 Resolved
Replace 4 pilot house windows. Windows broken by children throwing rocks from the street.
Condition: Unknown
Due 3 March 1999
Resolved 3 March 1999
Construction/Loadline
Issued 3 March 1999 Resolved
Replace all pvc and rubber hose couplings in bilge system with steel or equivalent material.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Deck/Cargo
Issued 3 March 1999 Resolved
Replace hydraulic hoses for anchor windlass. Hose fittings are cracked.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Accommodation/Occupational Safety
Issued 3 March 1999 Resolved
Stencil emergency escape from passenger accomodations.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Electrical
Issued 3 March 1999 Resolved
Place spliced wire connections in junction box forward overhead of engine room.
Condition: Unknown
Due 15 March 1999
Resolved 15 March 1999
Navigation
Issued 3 March 1999 Resolved
Provide updated Coast Pilot and Charts. 2 Coast Pilot pubs onboard dated 1992 and 1994. Vessel charts dated Sep 91 - Mar 93. Coast Pilot and Charts had no corrections or updates since new. Local notice to Mariners 7/99 and 9/99 onboard.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Electrical
Issued 3 March 1999 Resolved
Provide metal retention for wiring every 24".
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Construction/Loadline
Issued 3 March 1999 Resolved
Install stuffing tube for generator cable at aft bulkhead engine room.
Condition: Unknown
Due 3 March 1999
Resolved 3 March 1999
Engineering
Issued 3 March 1999 Resolved
Install insulation on ctr and stbd main engine exhaust piping in engine room.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Lifesaving
Issued 3 March 1999 Resolved
Replace type I reflective tape on life rings with type II retro-reflective.
Condition: Unknown
Due 15 March 1999
Resolved 15 March 1999
Electrical
Issued 3 March 1999 Resolved
Remove dead ended wiring, remove improper splices and make proper connections, multiple places in engine room and above operating station
Condition: Unknown
Due 3 March 1999
Resolved 3 March 1999
Accommodation/Occupational Safety
Issued 3 March 1999 Resolved
Stencil emergency escape stbd side exit in engine room.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Navigation
Issued 3 March 1999 Resolved
Provide current copy of Light List
Condition: Unknown
Due 15 March 1999
Resolved 15 March 1999
Lifesaving
Issued 3 March 1999 Resolved
Provide rescue boat or alternative arrangement to meet 46 CFR 185.10-35 andNYCMI Policy Ltr 1/89
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Lifesaving
Issued 3 March 1999 Resolved
25 and 4 persons life floats need to be stenciled with vessels name and maximum capacity both sides. Replace type II retro where needed.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Accommodation/Occupational Safety
Issued 3 March 1999 Resolved
Provide placard at stairway to upper deck with maximum capacity persons allowed.
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Electrical
Issued 3 March 1999 Resolved
Replace bulbs and light covers on light fixtures in passenger accomodations
Condition: Unknown
Due 10 March 1999
Resolved 10 March 1999
Fire Fighting
Issued 10 March 1998 Resolved
Repair horn on portable CO2 extinguisher.
Condition: Unknown
Due 10 April 1998
Resolved 16 March 1998
Navigation
Issued 10 March 1998 Resolved
Procure a copy of 46CFR subchapter T.
Condition: Unknown
Due 10 April 1998
Resolved 16 March 1998
Electrical
Issued 10 March 1998 Resolved
Provide electrical grade matting for the switchboard.
Condition: Unknown
Due 10 April 1998
Resolved 16 March 1998
Electrical
Issued 5 March 1997 Resolved
MAKE EMERGENCY LIGHTING SYSTEM OPERATIONAL. NO PASSENGERS PERMITTED BELOW MAIN DECK UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 12 March 1997
Resolved 19 March 1997
Fire Fighting
Issued 5 March 1997 Resolved
PROVIDE BRACKET FOR PORTABLE FIRE EXTINGUISHER LOCATED ON MAIN DECK, AFT.
Condition: Unknown
Due 12 March 1997
Resolved 19 March 1997
Fire Fighting
Issued 5 March 1997 Resolved
REPLACE HOSE ON PORTABLE CO2 EXTINGUISHER SER#17726
Condition: Unknown
Due 12 March 1997
Resolved 19 March 1997
Lifesaving
Issued 5 March 1997 Resolved
LABEL EMERGENCY ESCAPE HATCH FOR ENGINE ROOM & GENERATOR ROOM ON BOTH SIDES"EMERGENCY ESCAPE KEEP CLEAR"
Condition: Unknown
Due 12 March 1997
Resolved 19 March 1997
Engineering
Issued 5 March 1997 Resolved
LABEL EMERGENCY FUEL CUT OUT VALVES
Condition: Unknown
Due 12 March 1997
Resolved 19 March 1997
Electrical
Issued 5 March 1997 Resolved
PROPERLY SECURE EMERGENCY LIGHT FIXTURE LOCATED BELOW DECK.
Condition: Unknown
Due 12 March 1997
Resolved 19 March 1997
Construction/Loadline
Issued 6 March 1996 Resolved
REPAIR BROKEN LOCKING ARMS ON ESCAPE HATCH IN LAZARETTE.
Condition: Unknown
Due 20 March 1996
Resolved 14 March 1996
Navigation
Issued 15 March 1995 Resolved
STBD RUNNING LIGHT IMPROPER HEIGHT. PROCURE AND INSTALL PROPER LAMP.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 15 March 1995 Resolved
STENCIL AMOUNT OF PEOPLE ALLOWED ON UPPER DECK. ONE INCH LETTERS IN WAY OFLADDER.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 15 March 1995 Resolved
SEPARATE AND STENCIL CHILD/ADULT LIFE PERSERVERS LOCKER. MUST HAVE SIZE * AMOUNT.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Fire Fighting
Issued 15 March 1995 Resolved
PROVIDE SUFFICIENT HOSE FOR HAND PUMP.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Electrical
Issued 15 March 1995 Resolved
STENCIL RED "E" ON ALL EMERGENCY LIGHTING.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Lifesaving
Issued 15 March 1995 Resolved
PROVIDE OR REPAIR ADULT AND 1 CHILD SIZE LIFE PERSERVER. VESSEL RESTRICTEDTO CARRING A MAXIMUM OF PEOPLE AS FOLLOWS 144 ADULT AND 15 CHILDREN.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Unknown
Issued 25 May 1993 Resolved
CONDUCT INTERNAL EXAMINATION OR HYDROSTATIC TEST ON AIR RECEIVERS AS PER 46CFR 176.25-32. TEST TO BE COMPLETED IN PRESENCE OF AND TO SATISFACTION OF ATTENDING CG MARINE INSPECTOR NO LATER THAN 2 AUG 1993.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Electrical
Issued 25 May 1993 Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING SYSTEM. REQUIREMENT TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR NOT LATER THAN 10JUN93.
Condition: Unknown
Due 29 June 1993
Resolved 29 June 1993
Construction/Loadline
Issued 17 February 1993 Resolved
DISASSEMBLE MSD OVERBOARD DISCHARGE VALVE FOR INSPECTION BY C.G. MARINE INSPECTOR. CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 17 February 1993
Resolved 17 February 1993
Engineering
Issued 17 February 1993 Resolved
RENEW/REPAIR STARBOARD PROPELLER.
Condition: Unknown
Due 17 February 1993
Resolved 17 February 1993
Documentation
Issued 17 February 1993 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE PROVIDE DOCUMENTATION OF COMPLIANCE WITH DRUG TESTING REGULATIONS 46 CFR 16.
Condition: Unknown
Due 17 February 1993
Resolved 17 February 1993
Navigation
Issued 13 November 1992 Resolved
PROVIDE CURRENT CHARTS FOR THE VESSELS ROUTE. CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1992
Resolved 13 November 1992
Navigation
Issued 13 November 1992 Resolved
PROVIDE A CURRENT COPY OF INLAND NAVIGATION RULES OF THE ROAD (COMDTINST M16672.2B). CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1992
Resolved 13 November 1992
Documentation
Issued 13 November 1992 Resolved
PROVIDE A POSTED WASTE MANAGEMENT PLAN. CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1992
Resolved 13 November 1992
Fire Fighting
Issued 13 November 1992 Resolved
CONDUCT AN OPERATIONAL TEST OF THE ELECTRIC FIRE PUMP. CONDUCT TEST TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO CARRYING PASSENGERSFOR HIRE._x001C_ _x001C_
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Lifesaving
Issued 13 November 1992 Resolved
REPLACE FRAYED LIFELINES ON THE TOP TWO LIFEFLOATS. CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1992
Resolved 13 November 1992
Construction/Loadline
Issued 13 November 1992 Resolved
REPAIR BROKEN WELD JOINT ON THE CENTER SKEG IN THE GENERATOR/STEERING SPACE. CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1992
Resolved 13 November 1992
Lifesaving
Issued 13 November 1992 Resolved
ATTACH RETROREFLECTIVE TAPE TO ALL LIFEFLOATS. CORRECT PRIOE TO CARRYING PASSENGERS FOR HIRE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1992
Resolved 13 November 1992
Fire Fighting
Issued 13 November 1992 Resolved
PROVIDE SERVICING OR WEIGHING OF ALL BII FIRE EXTINGUISHERS. CORRECT PRIOR TO CARRYING PASSENGER FOR HIRE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1992
Resolved 13 November 1992
Construction/Loadline
Issued 13 November 1992 Resolved
REMOVE EXCESS OIL FROM THE ENGINEROOM BILGE. CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1992
Resolved 13 November 1992
Fire Fighting
Issued 13 November 1992 Resolved
PROVIDE SERVICING FOR FIXED HALON FLOODING SYSTEM IN THE ENGINEROOM. CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Electrical
Issued 13 November 1992 Resolved
PROVIDE COVER PLATE FOR LOOSE WIRING ON THE STBD GENERATOR LUBE OIL CONTROLBOX. CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1992
Resolved 13 November 1992
Construction/Loadline
Issued 13 November 1992 Resolved
REMOVE EXCESS OIL FROM GENERATOR/STEERING ROOM BILGE. CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1992
Resolved 13 November 1992
Navigation
Issued 13 November 1992 Resolved
PROVIDE UPDATED COPIES OR APPLICABLE EXTRACTS FROM U.S. COAST GUARD LIGHT LIST AND TIDE TABLES. CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1992
Resolved 13 November 1992
Fire Fighting
Issued 13 November 1991 Resolved
RECHARGE TWO (02) PORTABLE CO2 FIRE EXTINGUISHERS, ONE IN ENGINE ROOM AND ONE IN GENERATOR ROOM PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Construction/Loadline
Issued 13 November 1991 Resolved
PLUG MORSE PUSH/PULL CABLE STUFFING TUBE LOCATED IN MSD HOLDING TANK SPACE AND AT THE FORWARD ENGINE ROOM BULKHEAD STARBOARD SIDE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Construction/Loadline
Issued 13 November 1991 Resolved
PLUG COLLISION BULKHEAD PENETRATION APPROX. 1 FOOT BELOW MAIN DECK PRIOR TOCARRYING PASSENGERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Construction/Loadline
Issued 13 November 1991 Resolved
CLEAN ENGINEROOM AND GENERATOR ROOM BILGES OF EXCESS OIL PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Lifesaving
Issued 13 November 1991 Resolved
PROVIDE ONE OAR FOR LIFE FLOAT PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Construction/Loadline
Issued 13 November 1991 Resolved
PLUG STUFFING TUBE FOR HYDRAULIC LINE LOCATED IN FORWARD ENGINE ROOM STARBOARD SIDE PRIOR TO CARRYING PASSENGERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Engineering
Issued 5 November 1990 Resolved
PROVIDE AN OPERATIONAL TEST ON THE SAFETY RELIEF VALVES ON THE TWO AIR RECIEVERS.
Condition: Unknown
Due 5 November 1990
Resolved 5 November 1990
Engineering
Issued 5 November 1990 Resolved
REMOVE OIL IN THE BILGES IN THE STEERING COMPT. AND ENGINE COMPT.
Condition: Unknown
Due 5 November 1990
Resolved 5 November 1990
Engineering
Issued 5 November 1990 Resolved
PROVIDE AN INTERNAL OR HYDRO TEST ON TWO AIR RECIEVERS LOCATED INTHE ENG. ROOM.
Condition: Unknown
Due 5 November 1990
Resolved 5 November 1990
Electrical
Issued 5 November 1990 Resolved
PROVIDE A GLOBE COVER ON THE AFT STBD LIGHT IN THE STEERING COMPT. TO BE CORRECTED NO LATER THAN 05APR91
Condition: Unknown
Due 5 November 1990
Resolved 5 November 1990
Construction/Loadline
Issued 5 November 1990 Resolved
REMOVE CHAIRS OVER THE ESCAPE HATCH COVER FOR ENGINE COMPT. AND TEST THE OPERATION OF THE HATCH COVER. TO BE COMPLETED NO LATER THAN 05APR91.
Condition: Unknown
Due 5 November 1990
Resolved 5 November 1990
Engineering
Issued 5 November 1990 Resolved
CONDUCT AN OPERATIONAL TEST OF THE STBD ENG. TO BE CORRECTED NO LATER THAN 05APR91
Condition: Unknown
Due 5 November 1990
Resolved 5 November 1990
Electrical
Issued 5 November 1990 Resolved
REMOVE ALL WIRE NUTS LOCATED ON THE STBD ENG. TO BE CORRECTED NO LATER THAN05APR91
Condition: Unknown
Due 5 November 1990
Resolved 5 November 1990
Fire Fighting
Issued 5 November 1990 Resolved
PROVIDE ON BOARD ONE B1 FIRE EXTINGUISHER NO LATER THAN 05APR91
Condition: Unknown
Due 5 November 1990
Resolved 5 November 1990
Lifesaving
Issued 5 November 1990 Resolved
SHOW OR SUBMIT PLANS TO RESCUE PERSONS FROM WATER AND TO BRING ON BOARD THEVESSEL.
Condition: Unknown
Due 5 November 1990
Resolved 5 November 1990
Lifesaving
Issued 5 November 1990 Resolved
THE 8 MAN LIFE FLOAT CAN ONLY BE USED FOR THE PERIOD OF TIME 15APR TO 01NOV.
Condition: Unknown
Due 5 November 1990
Resolved 5 November 1990
Lifesaving
Issued 5 November 1990 Resolved
PROVIDE A MEANS OF RECOVERY OF PERSONAL FROM MAIN DECK TO WATERLINE.
Condition: Unknown
Due 5 November 1990
Resolved 5 November 1990
Fire Fighting
Issued 5 November 1990 Resolved
REFILL FOUR B2 FIRE EXTINGUISHERS LOCATED IN MULTIPLE AREAS. TO BE CORRECTED NO LATER THAN SIX MONTHS FROM 5NOV90.
Condition: Unknown
Due 5 November 1990
Resolved 5 November 1990
Documentation
Issued 5 November 1990 Resolved
PROVIDE ON BOARD A COPY OF THE VESSEL CERTIFICATE OF DOCUMENTATION. TO BE CORRECTED NO LATER THAN 05APR91
Condition: Unknown
Due 5 November 1990
Resolved 5 November 1990
Documentation
Issued 5 November 1990 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 November 1990
Resolved 5 November 1990
Lifesaving
Issued 5 November 1990 Resolved
REMOVE THE OLD HOMEPORT NAME ON THE AFT LIFERING.TO BE CORRECTED NO LATER THAN 05APR91.
Condition: Unknown
Due 5 November 1990
Resolved 5 November 1990
Lifesaving
Issued 5 November 1990 Resolved
REPAIR ONE PAD EYE ON THE BOTTOM LIFEFLOATON THE STBD SIDE. TO BE CORRECTEDNO LATER THAN 05APR91
Condition: Unknown
Due 5 November 1990
Resolved 5 November 1990
Construction/Loadline
Issued 29 May 1990 Resolved
E1-SECURED ALL DECK PLATES IN ENG. ROOM AND GENERATOR ROOM.
Condition: Unknown
Due 29 May 1990
Resolved 29 May 1990
Lifesaving
Issued 29 May 1990 Resolved
D1-PROVIDE 6 HAND HELD RED FLARES AND 6 HAND HELD SMOKES.
Condition: Unknown
Due 29 May 1990
Resolved 29 May 1990
Documentation
Issued 5 February 1990 Resolved
CREDIT DRYDOCK DUE 05AUG91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 5 February 1990
Resolved 5 February 1990
Construction/Loadline
Issued 14 November 1989 Resolved
INSTALL CAPTIVE CHAINS ON DECK HATCHES.
Condition: Unknown
Due 14 November 1989
Resolved 14 November 1989
Electrical
Issued 14 November 1989 Resolved
INSTALL BLANKS IN GENERATOR ROOM ELECTRIC PANEL.
Condition: Unknown
Due 14 November 1989
Resolved 14 November 1989
Engineering
Issued 14 November 1989 Resolved
STENCIL EMERGENCY FUEL SHUT-OFF VALVE.
Condition: Unknown
Due 14 November 1989
Resolved 14 November 1989
Engineering
Issued 14 November 1989 Resolved
REPAIR REACH ROD FOR AFTER FOR VALVE.
Condition: Unknown
Due 14 November 1989
Resolved 14 November 1989
Lifesaving
Issued 14 November 1989 Resolved
REPLACE LIFELINE ON RING BUOY LOCATED ON AFT BULKHEAD OF PILOTHOUSE.
Condition: Unknown
Due 14 November 1989
Resolved 14 November 1989

Casualty record · 4

2 August 2009Routine · role: Involved in a Marine Casualty · activity 3555193
14 April 2011Routine · role: Subject to Marine Inspection · 1 dead · activity 4003219
15 January 2013Routine · role: Involved in a Marine Casualty · activity 4517037
18 May 2016Routine · role: Involved in a Marine Casualty · activity 5885435
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

PASTIME PRINCESS (2009–2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.