← All vessels
NEVER ENUFF PATRIOT
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG East District (CGD-E) · Other hulls named NEVER ENUFF PATRIOT
NEVER ENUFF PATRIOT is a 1972 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 1985, most recently in October 2025, along with 105 deficiencies, 1 operational control and 1 casualty investigation in 2005.
Records from 1985 to 2025. Most recent: inspection, 1 October 2025.
- Built
- 1972
- Last inspected
- 1 October 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 105 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2005
Identity
545157
WDJ2365
47381
Flag
UNITED STATES
367757650
Maury page id
psix-47381
Inspections, by type
…with no type recorded3
Years with a record
39 calendar years (1985–2025)
The 60 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)61.1 ft × 18.0 ft × 4.3 ft
Registered tonnagegross 29 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCUBAVITCH YACHT CORP · MIAMI, FL, UNITED STATES · built 1972
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGLEN COVE, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Regulatory (Subpart C or D), Gross Ton
20 - Regulatory (Subpart C or D), Net Ton
20 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ2365MMSI 367757650 · active · compulsorily equipped · granted 8 October 2016, expires 8 October 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDD3583MMSI 367133440 · expired · compulsorily equipped · granted 5 August 2006, cancelled 8 October 2016 · licensed under a name not among this hull’s recorded names (not shown)
WCZ6862MMSI not assigned · expired · compulsorily equipped · granted 3 March 2000, cancelled 8 May 2010
WBG5421MMSI 366281820 · expired · compulsorily equipped · granted 10 February 1997, cancelled 29 July 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 60
1 October 2025
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8244265
14 May 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8135751
30 September 2024
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8011830
8 April 2024
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7892903
27 February 2024
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7868106
8 October 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7928827
13 October 2022
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7579748
26 September 2022
COI Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7560332
7 September 2022
Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7553375
15 September 2021
Annual Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7313145
13 October 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7076435
29 October 2019
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6840347
26 September 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6821977
1 October 2018
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6550618
10 April 2018
Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6388543
11 October 2017
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6285874
12 April 2016
Deficiency Check · Internal Structural Exam · Administrative Inspection · Simplified Stability Test · COI Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5966263
26 October 2015
Internal Structural Exam · Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5755563
20 October 2014
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5009964
14 June 2012
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4348779
1 February 2012
Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4240092
1 December 2011
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4301352
2 August 2011
Excursion Permit
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4106192
21 July 2011
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4086969
6 October 2010
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3863667
10 November 2008
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3390082
24 June 2008
Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3247545
9 October 2007
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3075745
8 June 2006
COI Inspection · Construction Oversight · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2674179
2 November 2005
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2527039
1 July 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2420370
11 April 2005
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2331459
4 March 2004
Periodic Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2088345
7 May 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1787801
1 May 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1611355
22 January 2002
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1480188
1 May 2001
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1064257
19 March 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1061421
15 June 2000
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1050726
14 June 2000
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1050599
26 April 2000
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 817346
5 April 2000
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1049291
28 April 1999
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 817301
28 April 1999
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1424736
10 April 1998
Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1381237
2 May 1997
Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1451181
17 April 1996
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1081798
28 April 1995
Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1160927
6 April 1995
Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1166418
28 March 1994
Re-Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 854053
27 April 1993
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1151195
13 April 1992
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 953268
19 March 1991
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1228455
27 April 1990
COI Inspection · Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1235322
2 June 1989
Administrative
Administrative · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1347092
24 April 1989
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 895179
25 April 1988
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1341535
24 April 1987
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1316224
7 May 1986
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 988334
30 April 1985
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1285954
Deficiency record · 105
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 May 2025
Resolved
An interconnected detection and alarm system must: consists of multiple-station smoke detectors meeting UL 217 and be installed such that the actuation of alarm in one area resulting in both audible and visual alarms in all areas, and must have independent power source. Alarms were tested in two separate areas of vessel, when alarm was activated in one area it did not activate the other two alarms. Vessel is restricted to limited coastwise route until MI can witness the operation of alarms to meet requirements of interconnected detection system.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 May 2025
Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, in a conspicuous space on the vessel where observation of passengers is likely. Vessel did not have the COI posted or visible to passengers.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 14 May 2025
Resolved
A vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible at the operators station, and display to passengers and others on request. Vessel did not have stability letter posted for observation.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 14 May 2025
Resolved
Each hydrostatic release unit, other than disposable unit, must be serviced; within 12 months of manufacture date and 12 months each subsequent servicing. The hydrostatic unit for the vessel's EPIRB was past the expiration date.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2025
Resolved
A vessel more than 26 feet, but not more than 65 feet must at carry at a minimum of one life buoy, with a lifeline and floating water light. Each ring buoy with a floating light must have a lanyard at least 3 feet, securing the water-light around the body of the ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 May 2025
Resolved
Each survival craft must be: secured to vessel by a painter with a float-free link permanently attached to the vessel, and stowed so that wen the vessel sinks the survival craft floats free. The vessel's life float was mot capable of being float-free, it was secured with bungee cord and missing data for float-free link.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2025
Resolved
The number and identification of the items stowed, and their size must be marked in clearly legible letters and numbers on containers for life jackets. Stowage compartments for life jackets did not indicate the number of life jackets available in the container.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 May 2025
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Life float paddles were missing vessel name.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 10 April 2024
Resolved
S and L. A power-driven fire pump shall be installed on each mechanically propelled "S" vessel which is a ferry vessel or which is permitted to carry more than 49 passengers, and on each mechanically propelled "L" vessel. Vessel O/O reported (prior to inspection) that the electric clutch in the fire pump is burnt out; awaiting part delivery. Affect repairs to fire pump to the satisfaction of the attending MI.
46 CFR 181.10-1(a)
OLD T
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 April 2024
Resolved
Oceans, coastwise, limited coastwise, and Great Lakes routes. A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry— Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel was missing 03 orange, smoke flares. Purchase new smoke flares and house in appropriate portable watertight container.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 February 2024
Resolved
To maintain a valid COI, you must complete your annual inspection within the periods specified in 176.500(b)(1). Vessel did not complete annual inspection which was due by 26 DEC 2023. Vessel will need to complete COI inspection prior to carrying passengers.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 September 2022
Resolved
A vessel <65' that operate on exposed waters must have a collision bulkhead. A quarter size hole was found in the collision bulkhead on the starboard side. Make hole permanently watertight. 46 CFR 179.210
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 26 September 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2022
Resolved
Bonding wire on flexible fill hose is broken. Repair or replace. 46 CFR 182.450(g)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 September 2022
Resolved
Each life jacket carried on a vessel on an Oceans Route must have a life jacket light. 5 adult and 2 child life jackets were found to have lights with dead batteries. -CORRECTED ON THE SPOT- 46 CFR 180.75
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 16 September 2021
Resolved
MI observed engine room fire dampeners were in operable, replace repair fire dampeners. 46 CFR 182.465(h) 701c
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 September 2021
Resolved
MMSI number was not inputed in VHF radio, add MMSI number to radio.
47 CFR 80.103(b)
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 September 2021
Resolved
FCC station license was expired, provide proof of valid station license. 47 CFR 80.13
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 September 2021
Resolved
Anchor night was in opp, make effective repairs to the anchor light.
33 CFR 83.30(b)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 September 2021
Resolved
Paddles in life float were cracked and deteriorated, replace paddles.
46 CFR 180.175(f)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 September 2021
Resolved
Lifejacket donning instruction placard were for the wrong PFD on the vessel. Provide up to date donning placard for current PFD's onboard.
46 CFR 185.516
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 16 September 2021
Resolved
09 PFD’s were missing lights and 03 PFD lights were not operable. Add and replace lights to PFD. 46 CFR 180.75
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 16 September 2021
Resolved
Watertight hatches on the #1 and #2 void needs gaskets replaced and knife edges clean to maintain watertight integrity. 46 CFR 179.360(a)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 16 September 2021
Resolved
Bilge suction in spaces #2, #3 and #4 were missing strainers. Provide strainers to bilge suction pipes. 46 CFR 182.510(b)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 September 2021
Resolved
Thru hull penetration on bulkheads were noticed in spaces #2, #3, #4, and #5. Make all bulkheads watertight. 46 CFR 179.302(c)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 September 2021
Resolved
Fire extinguisher crew accommodation area was not secured with proper bracket, install proper bracket that come with the manufacture. 46 CFR 181.500(d)
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 16 September 2021
Resolved
Provide adequate securing device for sewage discharge. 33 CFR 159.7(c)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 16 September 2021
Resolved
Cap ball valve located in the #3 space. 46 CFR 179.302(c)
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 16 September 2021
Resolved
Lighting fixtures located in the engine room, head and #3 space, replaced or fixed. 46 CFR 183.200(b)
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 16 September 2021
Resolved
Repair egress ladder in the #2 space. 46 CFR 176.800
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 16 September 2021
Resolved
Raw water suction valve in the #4 space needs to have an open and close indicator and operate properly. 46 CFR 176.800
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 October 2020
Resolved
While underway, a steady stream of water was found
entering the lazarette from the vessel's port side
rudder post. Make repairs to prevent ingress of sea
water. 46CFR176.25-10(a)(4) - 16c
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 October 2020
Resolved
Penetrations in watertight bulkhead between compartment
#4 and engine room need to be made watertight. 46CFR179.212(a) - 50c
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 October 2020
Resolved
Remove dead end wiring that transits through the forward
three compartments, or make sure wires terminate in a
junction box. 46CFR183.05-50(b) - 50c
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 October 2020
Resolved
Stowage of life jackets shall be adequately marked.
Provide labeling for adult life jacket stowage and for
separated child life jacket stowage. 46CFR185.604(f)/
46CFR180.78(a)(5) - 50c
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2020
Resolved
Vessel's stability letter determines the number of
passengers allowed on the upper deck based on vessel's
route. Properly mark the maximum passenger allowance for
upper deck as required. 46CFR185.602(g) - 50c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 October 2020
Resolved
Vessel fuel shutoff valve cable broke during testing.
Repair severed cable attached to fuel shutoff valve. 46CFR182.20-40(b)(3) - 10c
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019
Resolved
electricl outlet covers in machinery space and in under deck spaces msut be drip-proof or weathertight to protect against water splashing or dripping. 50C 46CFR183.05-50
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 29 October 2019
Resolved
electrical penetrations in under deck space fwd of engine room needs to be made watertight 10C 46CFR183-10.20(e)
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 29 October 2019
Resolved
provide max passengers allowed placard for upper deck 50C 46CFR185.30-3(e)
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 29 October 2019
Resolved
hand rail, aft stbd side, fastners are pulling out. remount section of handrail due to the use of man overboard ladder being used there. DO NOT USE THIS SECTION OF RAILING UNTIL FIXED.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2018
Resolved
Vessel only has 90 of required 100 adult PFDs. Provide 10 adult PFD with name and light. vessel limited to passengers. 46 CFR 180.71
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2018
Resolved
03 child PFD missing lights. Provide 03 lights prior to night time operations. 46 CFR180.75
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 1 October 2018
Resolved
Life buoy water light battery expired. Replace battery with Approved type for water-light. Prior to night time operations. 46 CFR 185.70
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 October 2018
Resolved
EPIRB test, lifesaving equipment inspections, drills not being logged when performed. Provide log. 46 CFR 185.728
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 October 2018
Resolved
VHFDSC radio not programmed with MMSI and do not have position data. Program radio with MMSI and supply position data. 47 CFR 80.905
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 October 2018
Resolved
Ship station license and safety radio certificate for missing. Provide license and safety radio. 47 CFR 80
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 October 2018
Resolved
Electronic charts are not updated. Provide proof of updated charts. 46 CFR 184.420
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 October 2018
Resolved
Life buoy water light battery expired. Replace battery with Approved type for water-light. 46 CFR 185.70
Engineering › Fuel Oil Service System › Ventilation
Issued 12 October 2017
Resolved
MAB01: Fuel vent hose on stbd side in laz is improper design/ SAE and has no flame screen: Replace.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 12 October 2017
Resolved
MAB02: Provide proof of MIS report.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 12 October 2017
Resolved
MAB03: 9 child lifejackets onboard. Child capacity reduced to 9 until 3 child life jackets added.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 July 2016
Resolved
AF01 Remove all dead end wires in forepeak.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 6 July 2016
Resolved
AF02 Fill holes in bulkhead where new windless cable was ran.
Lifesaving › Lifefloat › Painter
Issued 6 July 2016
Resolved
AF03 Replace painter lines on all life floats. Also replace grab lines and basket lines.
Fire Fighting › Fire Hoses › Length
Issued 6 July 2016
Resolved
AF04 Obtain 50ft commercial grade garden hose.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 6 July 2016
Resolved
AF05 Obtain 46 water lights for life jackets.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 6 July 2016
Resolved
AF06 Prove proper operation for single side band radio.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 July 2016
Resolved
AF07 Purchase approved first aid kit.
Stability › Watertight Integrity › General
Issued 6 July 2016
Resolved
AF08 Replace gasket on outside hatches to ensure watertight.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 October 2015
Resolved
Provide proper first aid kit for passenger service
Documentation › Markings/Placards › Warning Signs
Issued 26 October 2015
Resolved
Properly mark fuel shut off valves.
Engineering › Steering Gear System › Rudder Bearing
Issued 26 October 2015
Resolved
Properly repair starboard rudder packing to prevent excessive leakage
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 October 2014
Resolved
Owner did not have vaild COD, must provide new COD.
Engineering › Fuel Oil Service System › Valve
Issued 20 October 2014
Resolved
Emergency fuel shut off valves are constructed with a cable pull system, valves do not completely turn off with pull.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 20 October 2014
Resolved
Restricted to 78 adult total persons and 7 children until 12 new type I PDFs and 2 new child PFDs are provided.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 14 June 2012
Resolved
PROVE PROPER OPERATION OF ENGINES PRIOR TO THE CARRIAGE OF PASSENGERS.
Stability › Incline Test › General
Issued 1 December 2011
Resolved
Vessel restricted to 68 pax and 2 crew until simplified stability test is completed.
Engineering › Bilge Water Management System › Piping
Issued 21 July 2011
Resolved
Hole in bilge piping at the manifold in the E/R.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 21 July 2011
Resolved
Provide current/updated drug and alcohol program crew list to include all crew members.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 21 July 2011
Resolved
Replace light and/or battery.
Lifesaving › Lifefloat › Retroreflective Material
Issued 21 July 2011
Resolved
Lifefloats missing appropriate retroflective tape on underside.
Documentation › Certificates/Documents › FCC SSL
Issued 21 July 2011
Resolved
Missing original FCC station license.
Electrical › Lighting (service) › Lighting Fixture
Issued 21 July 2011
Resolved
Missing covers on outside deck lights.
Fire Fighting › Nozzles › Condition
Issued 21 July 2011
Resolved
Fire hose nozzle needs replacement.
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 July 2011
Resolved
Visual bilge high level alarm/ indicator (light) inoperable.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 6 October 2010
Resolved
Provide one additional flashlight.
Engineering › Bilge Water Management System › Pump
Issued 6 October 2010
Resolved
Provide portable bilge pump.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 6 October 2010
Resolved
Prove enrollment of deckhand in vessel's drug consortium.
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 October 2010
Resolved
Fuel shut off valves not labeled.
Fire Fighting › Fixed Gas Fire Extinguishing System › Nozzle
Issued 6 October 2010
Resolved
Provide plan/procedure to correct installation of mounted fireboy all IAW Fireboy owner's manual & 46CFR118.420. Nozzle is facing away from engines & into overhead deck framing. Cylinder is also sitting on a platform which can trap water.
Engineering › Bilge Water Management System › Pump
Issued 10 November 2008
Resolved
Demonstrate proper operation of lazarette bilge alarm. Bilge alarm failed to operate, not giving visual or audible indication of alarm condition.
Stability › Watertight Integrity › General
Issued 31 October 2007
Resolved
missing valve on collision bulkhead fitting
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 12 October 2007
Resolved
Vessel did not have a manual activation for system outside the space.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 9 October 2007
Resolved
System did not have a means of manual activation outside space being protected. Portable extinguishers and Fixed fire fighting system has not been seviced.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 15 August 2006
Resolved
Label life jacket stowage.
Communications › Radio Communications › EPIRB
Issued 15 August 2006
Resolved
Properly mount EPIRB.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 April 2005
Resolved
INSTALLED PRE-ENGINERED SYSTEM NOT OPERABLE, MAKE INSTALATION OPERABLE TO SHUT DOWN MDE'S UPON ACTIVATION.
Fire Fighting › Fire Pumps › Pressure
Issued 13 April 2005
Resolved
PUMP UNABLE TO SUPPLY WATER TO HOSE, MAKE OPERABLE.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 13 April 2005
Resolved
VESSEL MISSING 3 ADULT LIFE JACKETS. PASSENGER COUNT REDUCED UNTIL LIFE JACKETS ARE REPLACED.
Lifesaving › Lifebuoys › Serviceable
Issued 13 April 2005
Resolved
LINE ON LIFE RING WAS DETERIORATED BEYOND SERVICE, REQUIRED TO REPLACE LINE
Lifesaving › Lifefloat › Paddle
Issued 13 April 2005
Resolved
PADDLES NOT LABELED WITH VESSELS NAME. MARK PADDLES WITH VESSEL NAME
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 13 April 2005
Resolved
REPLACE MISSING HOSE CLAMPS ON EXHAUST HOSE IN E/R.
Communications › Alarms/Indicators
Issued 1 May 2002
Resolved
Idenify compartments on bilge alarms. LEGACY COMPONENT DESC: Bilge Alarm
Communications › Alarms/Indicators
Issued 1 May 2002
Resolved
Show proper operation of lazeratte alarm buzzer. LEGACY COMPONENT DESC: Bilge Alarm
Operations/Management › Passenger Operations
Issued 1 May 2002
Resolved
Provide placard at ladder to upper deck, identifying crew only. LEGACY COMPONENT DESC: Safety Orientation
Engineering › Fuel Oil Service System
Issued 1 May 2002
Resolved
Mark deck at location of fuel valves "Emergengy Fuel Shut-off". LEGACY COMPONENT DESC: Valve
Construction/Loadline › Penetrations
Issued 1 May 2002
Resolved
Make all identified bulkhead penetrations water tight.
Lifesaving › Lifejacket/PFD (General)
Issued 1 May 2002
Resolved
Vessel restricted to carrying 75 people, during warm water operation, due to missing life jackets. LEGACY COMPONENT DESC: Condition
Navigation
Issued 26 April 2000
Resolved
PROVIDE VALID FCC RADIO SAFETY CERTIFICATE.
Fire Fighting
Issued 26 April 2000
Resolved
CONDUCT ANNUAL SERVICING ON ALL PORTABLE AND FIXED FIRE EXTINGUISHERS.
Lifesaving
Issued 26 April 2000
Resolved
TOTAL PASSENGER COUNT REDUCED TO 69 DUE TO ONLY HAVING 71 ADULT JACKETS ON BOARD. AFTER PURCHASE OF 10 NEW JACKETS PASSENGER COUNT WILL BE RETURNED TO81.
Lifesaving
Issued 5 April 2000
Resolved
TOTAL NUMBER OF PASSENGERS LIMITED TO 69 DUE TO ONLY HAVING 71 ADULT JACKETS ON BOARD. AFTER PURCHASE OF 10 NEW ADULT JACKETS PASSENGER COUNT WILL BE RETURNED TO 81.
Navigation
Issued 5 April 2000
Resolved
PROVIDE VALID FCC RADIO SAFETY CERTIFICATE.
Fire Fighting
Issued 5 April 2000
Resolved
CONDUCT ANNUAL SERVICING ON ALL PORTABLE AND FIXED FIRE EXTINGUISHERS.
Casualty record · 1
1 July 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2420370
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
TWILIGHT (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.