07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 May 2025
Resolved
An interconnected detection and alarm system must: consists of multiple-station smoke detectors meeting UL 217 and be installed such that the actuation of alarm in one area resulting in both audible and visual alarms in all areas, and must have independent power source. Alarms were tested in two separate areas of vessel, when alarm was activated in one area it did not activate the other two alarms. Vessel is restricted to limited coastwise route until MI can witness the operation of alarms to meet requirements of interconnected detection system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 June 2025
Resolved 2 June 2025
Resolution: Alarms were tested to satisfaction of MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 May 2025
Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, in a conspicuous space on the vessel where observation of passengers is likely. Vessel did not have the COI posted or visible to passengers.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 2 June 2025
Resolution: Completed to satisfaction of MI.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 14 May 2025
Resolved
A vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible at the operators station, and display to passengers and others on request. Vessel did not have stability letter posted for observation.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 2 June 2025
Resolution: Completed to satisfaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 14 May 2025
Resolved
Each hydrostatic release unit, other than disposable unit, must be serviced; within 12 months of manufacture date and 12 months each subsequent servicing. The hydrostatic unit for the vessel's EPIRB was past the expiration date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 2 June 2025
Resolution: Completed to satisfaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2025
Resolved
A vessel more than 26 feet, but not more than 65 feet must at carry at a minimum of one life buoy, with a lifeline and floating water light. Each ring buoy with a floating light must have a lanyard at least 3 feet, securing the water-light around the body of the ring buoy.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2025
Resolved 2 June 2025
Resolution: Completed to satisfaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 May 2025
Resolved
Each survival craft must be: secured to vessel by a painter with a float-free link permanently attached to the vessel, and stowed so that wen the vessel sinks the survival craft floats free. The vessel's life float was mot capable of being float-free, it was secured with bungee cord and missing data for float-free link.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 22 May 2025
Resolved 22 May 2025
Resolution: Def cleared on spot to satisfaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2025
Resolved
The number and identification of the items stowed, and their size must be marked in clearly legible letters and numbers on containers for life jackets. Stowage compartments for life jackets did not indicate the number of life jackets available in the container.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 22 May 2025
Resolved 22 May 2025
Resolution: Crew rectified def on the spot to satisfaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 May 2025
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Life float paddles were missing vessel name.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 May 2025
Resolved 22 May 2025
Resolution: Corrected on the spot to satisfaction of MI.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 10 April 2024
Resolved
S and L. A power-driven fire pump shall be installed on each mechanically propelled "S" vessel which is a ferry vessel or which is permitted to carry more than 49 passengers, and on each mechanically propelled "L" vessel. Vessel O/O reported (prior to inspection) that the electric clutch in the fire pump is burnt out; awaiting part delivery. Affect repairs to fire pump to the satisfaction of the attending MI.
46 CFR 181.10-1(a)
OLD T
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 April 2024
Resolution: O/O provided photo evidence of new pump clutch and a video of fire pump operating - see documents section. Evidence is satisfactory; deficieny cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 April 2024
Resolved
Oceans, coastwise, limited coastwise, and Great Lakes routes. A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry— Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel was missing 03 orange, smoke flares. Purchase new smoke flares and house in appropriate portable watertight container.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2024
Resolved 19 April 2024
Resolution: O/O provided photo of newly purchased flares. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 February 2024
Resolved
To maintain a valid COI, you must complete your annual inspection within the periods specified in 176.500(b)(1). Vessel did not complete annual inspection which was due by 26 DEC 2023. Vessel will need to complete COI inspection prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2024
Resolution: Vessel recieved annual inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 September 2022
Resolved
A vessel <65' that operate on exposed waters must have a collision bulkhead. A quarter size hole was found in the collision bulkhead on the starboard side. Make hole permanently watertight. 46 CFR 179.210
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2022
Resolved 18 October 2022
Resolution: Hole in collision bulkhead made watertight using fire retardent resin with 3 layers of chopped strand mat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 26 September 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2022
Resolved 13 October 2022
Resolution: Crewmember is part of random drug testing program with Lower Township, NJ Municipal Utilities that meets 46 CFR 16.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 September 2022
Resolved
Bonding wire on flexible fill hose is broken. Repair or replace. 46 CFR 182.450(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2022
Resolved 18 October 2022
Resolution: Bonding wire satisfactorily replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 September 2022
Resolved
Each life jacket carried on a vessel on an Oceans Route must have a life jacket light. 5 adult and 2 child life jackets were found to have lights with dead batteries. -CORRECTED ON THE SPOT- 46 CFR 180.75
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 October 2022
Resolved 26 September 2022
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 16 September 2021
Resolved
MI observed engine room fire dampeners were in operable, replace repair fire dampeners. 46 CFR 182.465(h) 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2021
Resolved 16 September 2021
Resolution: 16SEP2021: CAPE MAY LADY's Master submitted pictures and video evidence of the repairs made to their fire dampener, repairs were made to the satisfaction of the duty [name withheld] no sail.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 September 2021
Resolved
MMSI number was not inputed in VHF radio, add MMSI number to radio.
47 CFR 80.103(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 5 October 2021
Resolution: Verified correct MMSI number was entered into radio.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 September 2021
Resolved
FCC station license was expired, provide proof of valid station license. 47 CFR 80.13
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 5 October 2021
Resolution: Verified Proof of valid FCC station license was provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 September 2021
Resolved
Anchor night was in opp, make effective repairs to the anchor light.
33 CFR 83.30(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 5 October 2021
Resolution: Anchor light was observed operating properly.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 September 2021
Resolved
Paddles in life float were cracked and deteriorated, replace paddles.
46 CFR 180.175(f)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 5 October 2021
Resolution: All paddles for life floats were found in satisfactory condition.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 16 September 2021
Resolved
Lifejacket donning instruction placard were for the wrong PFD on the vessel. Provide up to date donning placard for current PFD's onboard.
46 CFR 185.516
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 5 October 2021
Resolution: Verified correct lifejacket donning procedures posted.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 16 September 2021
Resolved
09 PFD’s were missing lights and 03 PFD lights were not operable. Add and replace lights to PFD. 46 CFR 180.75
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 5 October 2021
Resolution: 09 PFD lights were purchased and placed on PFDs, 03 inop lights had new batteries installed and are now operational.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 16 September 2021
Resolved
Watertight hatches on the #1 and #2 void needs gaskets replaced and knife edges clean to maintain watertight integrity. 46 CFR 179.360(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2021
Resolved 22 October 2021
Resolution: Recieved pictures of new gasket installed on #1 and #2 hatch covers.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 16 September 2021
Resolved
Bilge suction in spaces #2, #3 and #4 were missing strainers. Provide strainers to bilge suction pipes. 46 CFR 182.510(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 5 October 2021
Resolution: Strainer wire mesh was installed on the bilge suction piping in spaces #2,#3,#4.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 September 2021
Resolved
Thru hull penetration on bulkheads were noticed in spaces #2, #3, #4, and #5. Make all bulkheads watertight. 46 CFR 179.302(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 5 October 2021
Resolution: Open bulkhead penetrations were adequately filled with silicone in spaces #2,#3,#4,#5.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 September 2021
Resolved
Fire extinguisher crew accommodation area was not secured with proper bracket, install proper bracket that come with the manufacture. 46 CFR 181.500(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 5 October 2021
Resolution: Approved bracket was installed for the fire extinguisher in the crew accommodation space.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 16 September 2021
Resolved
Provide adequate securing device for sewage discharge. 33 CFR 159.7(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 5 October 2021
Resolution: Sewage discharge valve had new installed locking mechanism.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 16 September 2021
Resolved
Cap ball valve located in the #3 space. 46 CFR 179.302(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2021
Resolved 5 October 2021
Resolution: Hull penetration in #3 space was properly capped along with ball valve.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 16 September 2021
Resolved
Lighting fixtures located in the engine room, head and #3 space, replaced or fixed. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 5 October 2021
Resolution: Lighting fixtures in engine room, restroom, and #3 space were replaced and fixed.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 16 September 2021
Resolved
Repair egress ladder in the #2 space. 46 CFR 176.800
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2021
Resolved 5 October 2021
Resolution: Wooden ladder leading into #2 space was repaired and in satisfactory condition.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 16 September 2021
Resolved
Raw water suction valve in the #4 space needs to have an open and close indicator and operate properly. 46 CFR 176.800
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2021
Resolved 23 September 2021
Resolution: Observed valve handle indicates if it is open or closed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 October 2020
Resolved
While underway, a steady stream of water was found
entering the lazarette from the vessel's port side
rudder post. Make repairs to prevent ingress of sea
water. 46CFR176.25-10(a)(4) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2020
Resolved 18 November 2020
Resolution: Recieved video from owner of the rudder post not leaking while underway.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 October 2020
Resolved
Penetrations in watertight bulkhead between compartment
#4 and engine room need to be made watertight. 46CFR179.212(a) - 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 18 November 2020
Resolution: Owner filled penetrations with 5200, recieved photo.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 October 2020
Resolved
Remove dead end wiring that transits through the forward
three compartments, or make sure wires terminate in a
junction box. 46CFR183.05-50(b) - 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 18 November 2020
Resolution: Owner sent photo of removed wiring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 October 2020
Resolved
Stowage of life jackets shall be adequately marked.
Provide labeling for adult life jacket stowage and for
separated child life jacket stowage. 46CFR185.604(f)/
46CFR180.78(a)(5) - 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 18 November 2020
Resolution: Owner sent photos of lifejacket stowage placarding in place
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 October 2020
Resolved
Vessel's stability letter determines the number of
passengers allowed on the upper deck based on vessel's
route. Properly mark the maximum passenger allowance for
upper deck as required. 46CFR185.602(g) - 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 18 November 2020
Resolution: Owner sent photo of "crew only" sign posted on the ladder to the upper deck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 October 2020
Resolved
Vessel fuel shutoff valve cable broke during testing.
Repair severed cable attached to fuel shutoff valve. 46CFR182.20-40(b)(3) - 10c
Action required: 10 - Deficiency Rectified
Due 13 October 2020
Resolved 13 October 2020
Resolution: O/O repaired fuel shut of valve activating cable clamp.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019
Resolved
electricl outlet covers in machinery space and in under deck spaces msut be drip-proof or weathertight to protect against water splashing or dripping. 50C 46CFR183.05-50
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 10 December 2019
Resolution: Received email from Captain showing that electrical outlet covers were installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 29 October 2019
Resolved
electrical penetrations in under deck space fwd of engine room needs to be made watertight 10C 46CFR183-10.20(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2019
Resolved 29 October 2019
Resolution: owner sealed penetration with 3M 5200
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 29 October 2019
Resolved
provide max passengers allowed placard for upper deck 50C 46CFR185.30-3(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 10 December 2019
Resolution: Received email from Captain showing that the "Max Passenger Allowed" has been stenciled above the stairs leading to the upper deck.
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 29 October 2019
Resolved
hand rail, aft stbd side, fastners are pulling out. remount section of handrail due to the use of man overboard ladder being used there. DO NOT USE THIS SECTION OF RAILING UNTIL FIXED.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 10 December 2019
Resolution: Captain remounted the handrail with larger bolts.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2018
Resolved
Vessel only has 90 of required 100 adult PFDs. Provide 10 adult PFD with name and light. vessel limited to passengers. 46 CFR 180.71
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2019
Resolution: 10 additional PFD added to vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2018
Resolved
03 child PFD missing lights. Provide 03 lights prior to night time operations. 46 CFR180.75
Action required: 705 - Other - as specified
Resolved 23 October 2018
Resolution: lights affixed to PFDs and observed by marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 1 October 2018
Resolved
Life buoy water light battery expired. Replace battery with Approved type for water-light. Prior to night time operations. 46 CFR 185.70
Action required: 705 - Other - as specified
Resolved 23 October 2018
Resolution: Battery replaced, testing observed by marine inspector.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 October 2018
Resolved
EPIRB test, lifesaving equipment inspections, drills not being logged when performed. Provide log. 46 CFR 185.728
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 October 2018
Resolution: Owner provided notebook for logging of required information.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 October 2018
Resolved
VHFDSC radio not programmed with MMSI and do not have position data. Program radio with MMSI and supply position data. 47 CFR 80.905
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2019
Resolution: VHF radio programmed with MMSI number and has position displayed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 October 2018
Resolved
Ship station license and safety radio certificate for missing. Provide license and safety radio. 47 CFR 80
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2019
Resolution: New station license and safety radio certificate issued.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 October 2018
Resolved
Electronic charts are not updated. Provide proof of updated charts. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 October 2018
Resolution: Owner opted to use paper charts for navigation and purchased such.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 October 2018
Resolved
Life buoy water light battery expired. Replace battery with Approved type for water-light. 46 CFR 185.70
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 October 2018
Resolution: Battery replaced, testing observed by marine inspector.
Engineering › Fuel Oil Service System › Ventilation
Issued 12 October 2017
Resolved
MAB01: Fuel vent hose on stbd side in laz is improper design/ SAE and has no flame screen: Replace.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 1 November 2017
Resolution: Satisfactory pictures received.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 12 October 2017
Resolved
MAB02: Provide proof of MIS report.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 1 November 2017
Resolution: Received copy in email.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 12 October 2017
Resolved
MAB03: 9 child lifejackets onboard. Child capacity reduced to 9 until 3 child life jackets added.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 1 November 2017
Resolution: Received picture in email.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 July 2016
Resolved
AF01 Remove all dead end wires in forepeak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 11 August 2016
Resolution: Received email with photos showing dead end wires removed.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 6 July 2016
Resolved
AF02 Fill holes in bulkhead where new windless cable was ran.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 11 August 2016
Resolution: Received email photos of sealed holes in bulkhead.
Lifesaving › Lifefloat › Painter
Issued 6 July 2016
Resolved
AF03 Replace painter lines on all life floats. Also replace grab lines and basket lines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 11 August 2016
Resolution: Received email with photos showing new lines on life floats.
Fire Fighting › Fire Hoses › Length
Issued 6 July 2016
Resolved
AF04 Obtain 50ft commercial grade garden hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 11 August 2016
Resolution: Received email with photos of new commercial grade hose.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 6 July 2016
Resolved
AF05 Obtain 46 water lights for life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 23 May 2017
Resolution: Life jacket lights installed.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 6 July 2016
Resolved
AF06 Prove proper operation for single side band radio.
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 23 May 2017
Resolution: SSB radio is not operational.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 July 2016
Resolved
AF07 Purchase approved first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 11 August 2016
Resolution: Received email of approved first aid kit on board vessel.
Stability › Watertight Integrity › General
Issued 6 July 2016
Resolved
AF08 Replace gasket on outside hatches to ensure watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2016
Resolved 9 August 2016
Resolution: Hatches now tested to be watertight.