Records from 2012 to 2026. Most recent: inspection, 20 January 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 20
20 January 2026
Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8296400
22 January 2025
Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8063079
13 January 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8060997
29 February 2024
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7865159
7 March 2023
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7646848
1 February 2023
Hull Examination · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7631311
23 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7612387
8 March 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7408170
21 February 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7400322
5 March 2021
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7148184
18 February 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7142410
17 March 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6931021
16 April 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6660848
1 April 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6659993
13 February 2019
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6624856
9 May 2018
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6418023
6 February 2018
Plan Review "T" Boat · Simplified Stability Test · Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6382108
13 March 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6103661
14 February 2017
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6082505
2 March 2016
Plan Review "T" Boat · DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5822821
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 29 February 2024
Resolved
Each survival craft must be: Secured to the vessel by a painter with a float-free link permanently attached to the vessel except that a float-free link is not required if the vessel operates only on waters not as deep as the length of the painter. The inflatable buoyant apparatus was not secured to the vessel with a painter line.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 February 2024
Resolution: Vessel representative sent satisfactory photo showing painter line properly secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 February 2024
Resolved
Fuel lines must be accessible, protected from mechanical injury, and effectively secured against excessive movement and vibration by the use of soft nonferrous metal straps which have no sharp edges and are insulated to protect against corrosion. The fuel vent line on the vessel was ruptured.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 February 2024
Resolution: The vessel sent a satisfactory photo of the new marine grade fuel vent line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 February 2024
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. The fuel shut off valve for the auxiliary fuel tank did not close completely.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2024
Resolution: Vessel representative fixed fuel shut off valve.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 29 February 2024
Resolved
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF–DSC frequency transmitter meeting the requirements of § 80.1101(c)(3) and capable of transmitting J3E emission and a receiver capable of reception of J3E emission within the band 1710 to 2850 kHz, in addition to the VHF–DSC radiotelephone installation required by paragraph (a)(1) of this section. The VHF radio on board the vessel did not include the correct MMSI number.
46 CFR 80.905 (3)(i)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2024
Resolved 28 March 2024
Resolution: Vessel rep sent satisfactory photos showing MMSI programmed into radio.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 February 2024
Resolved
Where rigid nonmetallic material (plastic) is permitted
for use in piping systems by this section, the following
restrictions apply: Through hull fittings and shutoff
valves must be metallic. In the case of nonmetallic
hulls, materials that will afford an equal degree of
safety and heat resistivity as that afforded by the hull
may be approved. The vessel had a plastic through hull
fitting on the starboard side.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2024
Resolved 5 March 2024
Resolution: Vessel representative sent saisfactory photos of the new metallic through hull fitting.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 February 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication; Coast Guard Light List. The vessel had an out-dated Light List and Coast Pilot on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2024
Resolved 7 March 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 February 2024
Resolved
All electrical equipment and circuits must be clearly marked and identified. The 24 Volt DC distribution panel in the operating station needs to be labeled.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2024
Resolved 29 February 2024
Resolution: Vessel representative sent satisfactory photos showing labeling on the distribution panel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 February 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. The vessel had dead end wires in the operating station and battery void.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2024
Resolved 5 March 2024
Resolution: Vessel representative sent satisfactory photos showing dead end wires with marine grade terminations.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 February 2024
Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. Dead front covers were missing on the 24 Volt DC and 120 Volt AC distribution panels in the operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 March 2024
Resolved 29 February 2024
Resolution: Vessel representative sent satisfactory photos showing dead front covers on the distribution panels.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 29 February 2024
Resolved
EAP traning program: An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. The Discovery Whale Watch company did not have a designated/trained EAP SUpervisor/Designated Employer Representative (DER), and was not providing employees with the requoired EAP education and training program. Provide proof of training for at least supervisory personnel and all crew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2024
Resolution: Satisfactory evidence was provided for training of all crew members and EAP supervisor.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 7 March 2023
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80.
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. Vessel master to obtain Marine Radio Operator Permit (or higher) and provide documentation to the satisfaction of the Marine Inspector.
46 CFR 184.502 / 47 CFR 80.159(e)(1)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 January 2025
Resolution: Inspected Radio Operator Permit at Annual Inspection.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 February 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: charts or large enough scale to make safe navigation possible. Vessel has outdated navigation charts.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2022
Resolved 5 March 2022
Resolution: Operator sent photos of appropriate charts
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 22 February 2022
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Vessel has missing labels for two fuel shutoff valves.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2022
Resolved 5 March 2022
Resolution: Operator sent photos of properly labeled fuel shut off valves.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 February 2022
Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2.5 gallon buckets, with an attached lanyard placed so as to be easily available during an emergency. The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket. Vessel has missing fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2022
Resolved 5 March 2022
Resolution: Operator sent photos of appropriate fire buckets.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 February 2022
Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The flame screen shall consist of a single screen of corrosion resistant wire of at least 30x30 mesh. The flame screens
or arresters shall be of such size and design as to prevent reduction in the net cross-sectional area of the vent pipe and permit cleaning or renewal of the flames screens or arrester elements. Vessel has one missing flame screen and one flame screen bigger than 30x30 mesh.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2022
Resolved 7 March 2022
Resolution: Operator sent photos of newly installed flame screens.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 February 2022
Resolved
Ventilation of spaces containing diesel machinery. Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Vessel has multiple vent closures that are inoperable.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2022
Resolved 16 March 2022
Resolution: Operator sent photos / videos of proper operation of engine room dampers.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 February 2022
Resolved
Vessels shall be inspected for compliance with the standards required by this subchapter. For items not covered by standards in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge Marine Inspection as good marine practice. Vessel has light fixture on port side in engine room that is loosely fixed to the overhead.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2022
Resolved 16 March 2022
Resolution: Operator sent photo of light fixture repair.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 5 March 2021
Resolved
Each survival craft must be secured to the vessel by a painter with a float free link. Vessel's IBA had an improperly rigged Bowsing Line.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2021
Resolved 5 March 2021
Resolution: Vessel's lifesaving rigging was corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 March 2021
Resolved
A visual and audible high water level alarm must be provided for ach of the following unmanned spaces: shaft alley bilge. Vessel's high level water alarm for the lazarette did not work.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2021
Resolved 5 March 2021
Resolution: Deficiency corrected on the spot. Vessel replaced the high level alarm with a spare carried on board. Verified proper operation upon replacement.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 5 March 2021
Resolved
A hydrostatic release unit when used in a float free arrangement must be approved under 46 CFR 160.062 or 160.162. Vessels float free link did not have it's installation/expiry date marked on it.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 March 2021
Resolved 5 March 2021
Resolution: Deficiency corrected on the spot. Verified hydrostatic expiration date with lifesaving maintenance log.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2021
Resolved
An adult lifejacket must be carried for each person on board a vessel. Vessel has 30 adult kapok life jackets the need replacement. Reduced passenger count to 16 adults, 5 children, and 2 crew until life jackets are replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 February 2023
Resolution: Attending MI verified proper number of life jackets onboard the vessel.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 5 March 2021
Resolved
The master of the vessel shall ensure each EPIRB must be tested monthly and logged. Vessel needs to update it's log book to relect the completion of drills and tests.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2021
Resolved 8 March 2021
Resolution: Vessel has updated it's logbook to reflect it's recent events. Operator said they will do a better job of keeping track of info in logbook in the future.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 February 2019
Resolved
Both port and starboard props have clusted pitting located on the hub. Props need to be set the propeller shop to assess ability to grind and repair propellers. If unable to conduct repairs on the propellers both propellers will need to be replaced.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 February 2019
Resolution: Both rudders were cleaned, grinded and new material added.
Fire Fighting › Miscellaneous Items › B Class Division Penetrations
Issued 9 May 2018
Resolved
Fill 8 holes between engineroom and battery room with fire rated material.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2018
Resolved 9 May 2018
Resolution: all holes have been filled.
Engineering › Fuel Oil Service System › Piping
Issued 9 May 2018
Resolved
Fuel fill pipes must terminate at the weather deck so as not to allow the overflow of liquid or vapors into the inside of the vessel. 46 CFR 182.20-30
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2018
Resolved 13 February 2019
Resolution: Fuel fill pipes have been extended to terminate at the weather deck.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 May 2018
Resolved
Provide guards to the front of both main propulsion engines to protect from personnel injuries. 46 CFR 182.01-5
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2018
Resolved 22 February 2019
Resolution: Guard for MDE's have been installed
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 13 March 2017
Resolved
Two B-II fire extinguishers located outside in a box on the aft bulkhead were not mounted in brackets required by manufacturer. Both extinguishers were secured with a bungee cord to an eye screwed into the storage box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 13 February 2019
Resolution: B-II fire extinguishers have been mounted in approved brackets
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 March 2017
Resolved
The battery in the water light was not approved for use in the water light in accordance with manufacturer’s instructions. Part number was off by one number on Rayvac battery
Condition: Placed in Improper Service
Due 13 April 2017
Resolved 22 March 2017
Resolution: Replaced battery with approved part number.
Engineering › Fuel Oil Service System › Hose
Issued 13 March 2017
Resolved
Fuel and oil hoses contain unprotected non corrosion resistant fittings.
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 23 March 2017
Resolution: Wrapped fuel oil service fittings with PT tape.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 March 2017
Resolved
Examined forward bulkhead of Engine Room space and found bulkhead wire penetrations to be inadequately sealed to prevent water and/or vapor to exit from the space. Wire run was wrapped in a rubber gasket material and screwed to the bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 23 March 2017
Resolution: Sealed around wiring with a High Temp Silicon.