J-MACK is a 1969 passenger vessel (inspected). The Coast Guard has recorded 74 inspections since 1985, most recently in December 2024, along with 74 deficiencies, 4 operational controls, 1 with no removal date recorded and 2 casualty investigations between 2011 and 2017.

Records from 1985 to 2024. Most recent: inspection, 16 December 2024.

Built
1969
Last inspected
16 December 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

Flag
UNITED STATES
—
Maury page id
psix-47393

Inspections, by type

…with no type recorded11
Years with a record 27 calendar years (1985–2024)
The 74 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)62.2 ft × 24.0 ft × 3.6 ft
Registered tonnagegross 46 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFULTON SHIPYARD · ANTIOCH, CA, UNITED STATES · built 1969
Hull materialSteel
PropulsionCombination Types
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 26 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Regulatory (Subpart C or D), Gross Ton
46 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 74

16 December 2024 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8047293
27 September 2024 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8011999
22 April 2024 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7899468
23 May 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7695117
21 February 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7638301
11 June 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7474163
30 August 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7296483
19 September 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7061343
18 September 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6834248
12 July 2019 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6716804
18 October 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6561312
13 September 2018 Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6539918
2 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6367922
29 September 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6353899
6 September 2017 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6259896
21 April 2017 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6134133
21 April 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6299902
12 May 2016 Deficiency Check · Annual Inspection · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5938581
1 September 2015 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5232053
25 July 2012 DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4397259
27 September 2011 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4154645
26 January 2010 Plan Review "T" Boat · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3670041
7 January 2009 COI Inspection · Initial Certification · DAPI Audit · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3390354
11 July 1997 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1115012
27 November 1996 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1185000
19 June 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1079010
22 May 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1357615
3 May 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1088075
22 February 1996 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1428599
30 October 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1188863
4 October 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1183337
26 September 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 879941
14 June 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1187123
30 May 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 873724
12 May 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 907432
5 May 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1347106
11 April 1995 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 846594
16 March 1995 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1177071
22 December 1994 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1156650
7 July 1994 Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1173736
18 May 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 860246
29 April 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 858649
25 April 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 857605
12 April 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 857778
17 March 1994 Deficiency Check · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1165041
13 January 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 851057
10 December 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1458125
29 October 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1145793
23 August 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 849909
19 June 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 841134
26 May 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1144563
4 March 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1142666
18 February 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1144246
15 December 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1144462
25 November 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 828248
15 October 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1459789
7 July 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1269193
11 June 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 955913
29 April 1992 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 959927
23 April 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1261957
16 January 1992 Excursion Permit
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 960079
14 November 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1245054
7 November 1991 Excursion Permit
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1250421
18 April 1991 Excursion Permit
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 917526
16 March 1990 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 922889
26 September 1989 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1210244
31 August 1989 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1204993
31 August 1989 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1230145
29 March 1989 Re-Inspection · Drydock Extension
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1349026
27 April 1988 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1342319
20 May 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1025130
26 March 1987 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1010824
17 April 1986 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1307273
9 April 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 981928

Deficiency record · 74

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 September 2024 Resolved
A vessel that is exposed to salt water not more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every five years. The vessel has not completed a drydock examination within the last five years. Conduct satisfactory drydock examination prior to the carriage of passengers. 46 CFR 176.600(c)(2)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2024
Resolution: Vessel completed satisfactory dry dock.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 May 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Marine inspector observed expired medications and eyewash in first aid kit on board the vessel. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2024
Resolved 24 May 2024
Resolution: Vessel operator provided email stating expired medications were replaced with new.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 May 2024 Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Marine inspector observed dead end wires for light fixture in port side pilot house. 46 CFR 176.25-50(a) Old T
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 24 May 2024
Resolution: Vessel operator provided email confirming loose wires were removed by mechanic.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. No. 2 engine is inoperable due to starter malfunction. Vessel must make effective repairs to ensure No. 2 engine is working correctly. 46 CFR 182.200(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2023
Resolution: Replaced No.2 engine starter and battery. Engine No.2 is now operating correctly.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 February 2023 Resolved
Annual Inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel did not complete its required Annual Inspection in 2022. Vessel annual inspection window for 3rd annual inspection expired 08SEP2022. 46 CFR 176.500(b)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2023
Resolution: Performed annual inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 February 2023 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required - waterlight attached to one of the ring life buoy is not operational. 46 CFR 180.70(d) 705 - Daylight operations only
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 May 2024
Resolution: Verified light operation.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 February 2023 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels who: Occupy a position, or perform the duties and functions of a position, required by the vessel’s Certificate of Inspection. During annual inspection, Employer was not able to provide documentation for program and to show enrollment for crewmembers. 46 CFR 16.230(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2023
Resolved 7 May 2024
Resolution: Verified DAPI paperwork.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 February 2023 Resolved
A vessel must comply with the applicable requirements for any radio…installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel Master was not able to provide Marine Operator Permit. Additionally, vessel is not equipped with VHF-DSC radios at either operating station. 46 CFR 184.502 47 CFR 80.159(e)(1) 47 CFR 80.905(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2023
Resolved 7 May 2024
Resolution: Verified documentation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 February 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. Battery installations do not have covers on terminals. 46 CFR 183.200(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2023
Resolved 7 May 2024
Resolution: Verified covers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 February 2023 Resolved
Each battery must be … secured to protect against shifting with the roll and pitch of the vessel. Batteries are not secured. 46 CFR 183.350(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2023
Resolved 7 May 2024
Resolution: Verified securing arrangement.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 August 2021 Resolved
A vessel must carry either a first-aid kit approved under the approval series 160.041 or a kit with the equivelant contents and instructions. For equivelant kits, the contents must be stowed in a suitable, watertight container that is marked "First Aid Kit". A first-aid kit must be easily visble and readily available. Replace all expired contents in first-aid kit with new.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2021
Resolved 30 September 2021
Resolution: Received photos of new first aid kit with expiration dates.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2021 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure and personnel injury. Forward and aft ramp hydraulic hoses found wasted. Replace with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2021
Resolved 30 September 2021
Resolution: Received photos of new hydraulic hoses installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2020 Resolved
Conductors from receptacles to fixtures shall be protected as to provide an insulation the same as that of the conductors joined. 12 VDC receptacle in the Grand Isle side of the operating station was found without adequate insulation and exposed conductor.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 October 2020
Resolved 24 September 2020
Resolution: 12 VDC outlet and wire run removed from the vessel.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 6 September 2017 Resolved
All adult and children lifejackets must be marked with vessel name IAW 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 2 October 2017
Resolution: Operator provided photographic evidence of corrective action.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 21 April 2017 Resolved
This is a cable ferry system, with the only system of propulsion is for the ferry to pull itself along the cable. the defeciency is that the cable parted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 18 May 2017
Resolution: SCC SF cleared under the direction of DMI ([name withheld]) 1630 LCL
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 12 July 2016 Resolved
Mark ring buoy with vessel name.
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 18 August 2016
Electrical › Electric Supply System (service) › Cable
Issued 12 July 2016 Resolved
Provide covers for wiring terminals in engine room and storage locker.
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 18 August 2016
Deck/Cargo › Cargo Stowage › General
Issued 12 July 2016 Resolved
Replace weeping hydraulic ram for vehicle blocking device.
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 18 August 2016
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 12 May 2016 Resolved
Provide additional deckhand as a lookout if Master is wearing hearing protection.
Action required: 705 - Other - as specified
Resolved 19 August 2016
Resolution: Hearing protection no longer required onboard.
Engineering › Fuel Oil Service System › Hose
Issued 1 September 2015 Resolved
Fuel supply hoses to Generator are single hose clamped. Install second hose clamp at each fuel line connection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 September 2015
Resolved 1 October 2015
Resolution: Fuel lines satisfactorily attached to generator.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 1 September 2015 Resolved
Gasket on watertight hatch to aft void was damaged, losing watertight integrity. Replace gasket.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 October 2015
Resolved 1 October 2015
Resolution: Gasket on hatches are replaced.
Documentation › Logs/Records › Drug Test Records
Issued 25 July 2012 Resolved
Alcohol testing devices not onboard as required by 46 CFR 4.
Due 7 September 2012
Resolved 5 September 2012
Documentation › Logs/Records › Drug Test Records
Issued 25 July 2012 Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Due 24 August 2012
Resolved 21 August 2012
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 September 2011 Resolved
Replace expire water light battery.
Action required: 705 - Other - as specified
Due 12 October 2011
Resolved 13 October 2011
Resolution: The expire battrey was replaced with non-expired battery.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 27 September 2011 Resolved
Properly label all child sized life jackets and make readily accessible.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 October 2011
Resolved 13 October 2011
Resolution: The vessel rep properly labeled the jackets with the name of the vessel.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 27 September 2011 Resolved
Properly label all child and adult life jacket storage compartments.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 October 2011
Resolved 13 October 2011
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 27 September 2011 Resolved
Install approved bracket for BII fire extinguisher in the pilothouse.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 October 2011
Resolved 13 October 2011
Resolution: Installed the correct approved bracket.
Engineering › Bilge Water Management System › Hose
Issued 27 September 2011 Resolved
Double hose clamp all flexible hoses on the bilge system.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 October 2011
Resolved 17 October 2011
Resolution: Installed double hose clamps on all required flexible hoses.
Engineering › Fuel Oil Service System › Pump
Issued 27 September 2011 Resolved
Re-install fuel accessories on the aft prime mover.
Action required: 705 - Other - as specified
Due 12 October 2011
Resolved 13 October 2011
Resolution: The bracket was re-installed with bolts and lock washers.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 27 September 2011 Resolved
Install 30/30 mesh flame screen on both fuel tank vent pipes.
Action required: 705 - Other - as specified
Due 12 October 2011
Resolved 17 October 2011
Resolution: Installed 30/30 mesh flame screens on both fuel tanks.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 7 January 2009 Resolved
Provide training record logbook. 46CFR185.520
Due 29 August 2009
Resolved 21 September 2009
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 7 January 2009 Resolved
Post emergency instructions as per 46CFR185.510
Due 29 August 2009
Resolved 21 September 2009
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 7 January 2009 Resolved
Provide emergency training/drills log 46CFR185.524
Due 29 August 2009
Resolved 21 September 2009
Documentation › Certificates/Documents › Stability Letter
Issued 7 January 2009 Resolved
Post stability letter as per 46CFR176.306
Due 29 August 2009
Resolved 21 September 2009
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 7 January 2009 Resolved
Provide method of documenting passenger count as per 46CFR185.504
Due 29 August 2009
Resolved 21 September 2009
Operations/Management › Drug and Alcohol Testing › CG Notification (positive results/refusals)
Issued 7 January 2009 Resolved
Conduct Drug and Alcohol Program audit with Coast Guard representative.
Due 29 August 2009
Resolved 21 September 2009
Resolution: Completed audit wiht DAPI officer.
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 January 2009 Resolved
Provide engineering assessment of cracked longitudinal frames located in voids 2 and 4.
Due 29 August 2009
Resolved 29 July 2009
Resolution: Received assessment from California Certified Professional Engineer [name withheld] attesting to the condition of the structural integrity of the J-MACK. The condition of the vessel does not require immediate repair.
Construction/Loadline › Hull › Hull Plating
Issued 7 January 2009 Resolved
Provide results of routine underwater survey.
Due 29 September 2009
Resolved 21 September 2009
Resolution: Hull examined by CALTRANS bridge inspectors with satisfactory results.
Lifesaving › Lifebuoys › Not on Board
Issued 7 January 2009 Resolved
Provide additional life ring (place on each side) to facilitate recovery of man overboard.
Due 29 August 2009
Resolved 21 September 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 January 2009 Resolved
Provide separation of child and adult PFD's, and label properly.
Due 29 August 2009
Resolved 21 September 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 January 2009 Resolved
Provide first aid kit (coast guard approved as per 46CFR160.041)
Due 29 August 2009
Resolved 21 September 2009
Construction/Loadline › Hull › Hull Plating
Issued 7 January 2009 Resolved
Conduct satisfactory drydock exam. Vessel was issued a COI based on CALTRANS prior hull examination and underwater examination 17 August 2009. No extensions should be allowed to this requirement.
Due 31 January 2010
Resolved 28 February 2010
Resolution: Completed satisfactory drydock exam.
Construction/Loadline
Issued 22 May 1996 Resolved
PROVIDE PERMANENT RESTRAINT SYSTEM FOR 12 ON-DECK CEMENT BALLAST BLOCKS LOCATED AT THE EAST-STBD END OF FERRY. COMPLETION OF THIS REQUIREMENT SHALLBE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 22 May 1996
Resolved 22 May 1996
Construction/Loadline
Issued 22 February 1996 Resolved
Provide proper restraint device to prevent the movement of the cement trim blocks on the starboard east end of the ferry.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Engineering
Issued 26 September 1995 Resolved
Demonstrate proper operation of east end engine emergency shut down.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Engineering
Issued 26 September 1995 Resolved
Properly remove excess liquid from east end engine stack collector.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Lifesaving
Issued 14 June 1995 Resolved
Make proper repairs to water leaking from the air conditioner units on to the electrical engine bridge console.
Condition: Unknown
Due 14 June 1995
Resolved 14 June 1995
Engineering
Issued 14 June 1995 Resolved
Install protective guards on engine governor throttle control linkage on deck.
Condition: Unknown
Due 14 June 1995
Resolved 14 June 1995
Engineering
Issued 12 May 1995 Resolved
Prior to operating East end engine, clean and fix oil leaking on to exhaustmanifold.
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Engineering
Issued 12 May 1995 Resolved
Fix hydraulic leaks to prevent oil from leaking.
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Electrical
Issued 12 May 1995 Resolved
Demonstrate proper operation of ships generator.
Condition: Unknown
Due 2 June 1995
Resolved 2 June 1995
Engineering
Issued 12 May 1995 Resolved
Properly label switches in east end pilot house.
Condition: Unknown
Due 2 June 1995
Resolved 2 June 1995
Engineering
Issued 12 May 1995 Resolved
Prior to operating east end engine, renew the oil soak exhaust lagging withclean lagging.
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Engineering
Issued 12 May 1995 Resolved
Demonstrate proper operation of electric governor for main engines.
Condition: Unknown
Due 2 June 1995
Resolved 2 June 1995
Electrical
Issued 16 March 1995 Resolved
Remove from the engineroom deck and provide proper support for the electrical throttle control wiring.
Condition: Unknown
Due 16 March 1995
Resolved 16 March 1995
Construction/Loadline
Issued 22 December 1994 Resolved
Provide a copy of the hull gauging report.
Condition: Unknown
Due 22 December 1994
Resolved 22 December 1994
Engineering
Issued 12 April 1994 Resolved
DO NOT OPERATE WEST END ENGINE UNTIL OIL LEAK HAS BEEN STOPPED AND DEMONSTRATED TO THE ATTENDING COAST GUARD MARINE INSPECTOR, WITH SATISFACTORY REPAIRS.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Engineering
Issued 13 January 1994 Resolved
PROVIDE PROPER PERSONNEL PROTECTION ON THE WEST END ENGINE'S EXHAUST PIPE.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Engineering
Issued 29 October 1993 Resolved
PRIOR TO USING THE WEST END ENGINE IN SERVICE OR 29NOV93, WHICHEVER OCCURS FIRST, PROPERLY REPAIR THE EXHAUST MANIFOLD (STOP OIL FROM LEAKING ON TO THE EXHAUST PIPE) TO THE SATISFACTION OF THE COGNIZANT O.C.M.I.
Condition: Unknown
Due 29 October 1993
Resolved 29 October 1993
Engineering
Issued 19 June 1993 Resolved
REPLACE ALL SPLIT RING HYDRAULIC COLLARS WITH APPROVED COLLAR DEVICES TO THE SATISFACTION OF THE COGNIZANT O.C.M.I.
Condition: Unknown
Due 19 June 1993
Resolved 19 June 1993
Electrical
Issued 4 March 1993 Resolved
REPLACE MISSING LIGHT GOBLE COVERS IN OPERATORS AREA AND CABLE HOUSE.
Condition: Unknown
Due 4 March 1993
Resolved 4 March 1993
Engineering
Issued 15 October 1992 Resolved
REPAIR LEAKING OIL LINES IN ENGINEROOM TO PREVENT AN OIL POLLUTION INCIDENTAND PREVENT A PERSONNEL SAFETY HAZARD.
Condition: Unknown
Due 15 October 1992
Resolved 15 October 1992
Navigation
Issued 29 April 1992 Resolved
INSTALL RESTRICTED IN ABILITY TO MANEUVER DAY SHAPES AND LIGHTS FOR UNDERWAY OPERATIONS.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Engineering
Issued 29 April 1992 Resolved
MARK FUEL SHUT OFF VALVES.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Fire Fighting
Issued 29 April 1992 Resolved
PROVIDE SUFFICANT LENGTH OF HOSE, AT LEAST 15 FEET, FOR HAND BILGE/FIRE PUMP.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Documentation
Issued 29 April 1992 Resolved
PROVIDE A COPY OF VESSEL'S DRUG TESTING PROGRAM ABOARD THE VESSEL.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Construction/Loadline
Issued 29 April 1992 Resolved
UNCLOG BILGE STRAINER SCREENS.
Condition: Unknown
Due 14 May 1992
Resolved 14 May 1992
Documentation
Issued 16 March 1990 Resolved
OBTAIN COPY OF STABILITY EXEMPTION LETTER AND POST IN WHEEL HOUSE.
Condition: Unknown
Due 16 March 1990
Resolved 16 March 1990
Lifesaving
Issued 16 March 1990 Resolved
PROVIDE 5 ADDITIONAL ADULT PFD'S TO REPLACE REJECTED PFD'S WITH HOLED FLOATION PACKETS. VESSEL RESTRICTED TO 30 TOTAL PASSENGERS UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 16 March 1990
Resolved 16 March 1990
Construction/Loadline
Issued 31 August 1989 Resolved
CONDUCT AUDIO GAUGING OF SHELL PLATING AND INTERNAL SUBDIVISION BULKHEADS. EACH PLATE SHALL BE TESTED AT FIVE (5) SEPARATE POINTS.
Condition: Unknown
Due 31 August 1989
Resolved 31 August 1989
Electrical
Issued 26 March 1987 Resolved
INSTALL COVERS FOR ELECTRICAL LIGHTING FIXTURES WHERE MISSING IN SHEVE ROOMOR RENEW THE FIXTURES.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Fire Fighting
Issued 26 March 1987 Resolved
PROVIDE NEW 1 1/4" FIRE HOSE AND SUPPLY LINE.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Lifesaving
Issued 26 March 1987 Resolved
PROVIDE ONE ADDITIONAL ADULT LIFEJACKET (PFD) VESSEL IS RESTRICTED TO 34 PASSENGERS UNTIL ADDITIONAL PFD IS ONBOARD.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987
Fire Fighting
Issued 26 March 1987 Resolved
PROVIDE PORTABLE HAND OPERATED FIRE/BILGE PUMP.
Condition: Unknown
Due 26 March 1987
Resolved 26 March 1987

Casualty record · 2

29 March 2011Routine · role: Involved in a Marine Casualty · activity 4056205
21 April 2017Routine · role: Involved in a Marine Casualty · activity 6299902
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.