MAURY USCG vessel records
← All vessels

J-MACK

Built
1969
Last inspected
16 December 2024
Documentation
Valid · NVDC file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 December 2024
…with no type recorded1
Operational controls 1 with no removal date recorded
Years with a record 9 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-47393

Documentation record

Registered dimensions (L × B × D)62.2 ft × 24.0 ft × 3.6 ft
Registered tonnagegross 46 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFULTON SHIPYARD · ANTIOCH, CA, UNITED STATES · built 1969
Hull materialSteel
PropulsionCombination Types
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 26 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Regulatory (Subpart C or D), Gross Ton
46 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 18 inspections, each with its date, unit and type; 19 deficiencies with the resolution recorded against each; 1 operational control with no removal date recorded; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

16 December 2024 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8047293
27 September 2024 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8011999
22 April 2024 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7899468
23 May 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7695117
21 February 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7638301
11 June 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7474163
30 August 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7296483
19 September 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7061343
18 September 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6834248
12 July 2019 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6716804
18 October 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6561312
13 September 2018 Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6539918
2 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6367922
29 September 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6353899
6 September 2017 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6259896
21 April 2017 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6134133
21 April 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6299902
12 May 2016 Deficiency Check · Annual Inspection · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5938581

Deficiency record · 19

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 September 2024 Resolved
A vessel that is exposed to salt water not more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every five years. The vessel has not completed a drydock examination within the last five years. Conduct satisfactory drydock examination prior to the carriage of passengers. 46 CFR 176.600(c)(2)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2024
Resolution: Vessel completed satisfactory dry dock.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 May 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Marine inspector observed expired medications and eyewash in first aid kit on board the vessel. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2024
Resolved 24 May 2024
Resolution: Vessel operator provided email stating expired medications were replaced with new.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 May 2024 Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Marine inspector observed dead end wires for light fixture in port side pilot house. 46 CFR 176.25-50(a) Old T
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 May 2024
Resolved 24 May 2024
Resolution: Vessel operator provided email confirming loose wires were removed by mechanic.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2023 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. No. 2 engine is inoperable due to starter malfunction. Vessel must make effective repairs to ensure No. 2 engine is working correctly. 46 CFR 182.200(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2023
Resolution: Replaced No.2 engine starter and battery. Engine No.2 is now operating correctly.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 February 2023 Resolved
Annual Inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel did not complete its required Annual Inspection in 2022. Vessel annual inspection window for 3rd annual inspection expired 08SEP2022. 46 CFR 176.500(b)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2023
Resolution: Performed annual inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 February 2023 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required - waterlight attached to one of the ring life buoy is not operational. 46 CFR 180.70(d) 705 - Daylight operations only
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 May 2024
Resolution: Verified light operation.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 February 2023 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels who: Occupy a position, or perform the duties and functions of a position, required by the vessel’s Certificate of Inspection. During annual inspection, Employer was not able to provide documentation for program and to show enrollment for crewmembers. 46 CFR 16.230(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2023
Resolved 7 May 2024
Resolution: Verified DAPI paperwork.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 February 2023 Resolved
A vessel must comply with the applicable requirements for any radio…installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel Master was not able to provide Marine Operator Permit. Additionally, vessel is not equipped with VHF-DSC radios at either operating station. 46 CFR 184.502 47 CFR 80.159(e)(1) 47 CFR 80.905(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2023
Resolved 7 May 2024
Resolution: Verified documentation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 February 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. Battery installations do not have covers on terminals. 46 CFR 183.200(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2023
Resolved 7 May 2024
Resolution: Verified covers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 February 2023 Resolved
Each battery must be … secured to protect against shifting with the roll and pitch of the vessel. Batteries are not secured. 46 CFR 183.350(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 March 2023
Resolved 7 May 2024
Resolution: Verified securing arrangement.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 August 2021 Resolved
A vessel must carry either a first-aid kit approved under the approval series 160.041 or a kit with the equivelant contents and instructions. For equivelant kits, the contents must be stowed in a suitable, watertight container that is marked "First Aid Kit". A first-aid kit must be easily visble and readily available. Replace all expired contents in first-aid kit with new.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2021
Resolved 30 September 2021
Resolution: Received photos of new first aid kit with expiration dates.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2021 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure and personnel injury. Forward and aft ramp hydraulic hoses found wasted. Replace with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2021
Resolved 30 September 2021
Resolution: Received photos of new hydraulic hoses installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2020 Resolved
Conductors from receptacles to fixtures shall be protected as to provide an insulation the same as that of the conductors joined. 12 VDC receptacle in the Grand Isle side of the operating station was found without adequate insulation and exposed conductor.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 October 2020
Resolved 24 September 2020
Resolution: 12 VDC outlet and wire run removed from the vessel.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 6 September 2017 Resolved
All adult and children lifejackets must be marked with vessel name IAW 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 2 October 2017
Resolution: Operator provided photographic evidence of corrective action.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 21 April 2017 Resolved
This is a cable ferry system, with the only system of propulsion is for the ferry to pull itself along the cable. the defeciency is that the cable parted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 18 May 2017
Resolution: SCC SF cleared under the direction of DMI ([name withheld]) 1630 LCL
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 12 July 2016 Resolved
Mark ring buoy with vessel name.
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 18 August 2016
Electrical › Electric Supply System (service) › Cable
Issued 12 July 2016 Resolved
Provide covers for wiring terminals in engine room and storage locker.
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 18 August 2016
Deck/Cargo › Cargo Stowage › General
Issued 12 July 2016 Resolved
Replace weeping hydraulic ram for vehicle blocking device.
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 18 August 2016
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 12 May 2016 Resolved
Provide additional deckhand as a lookout if Master is wearing hearing protection.
Action required: 705 - Other - as specified
Resolved 19 August 2016
Resolution: Hearing protection no longer required onboard.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.