Records from 2016 to 2025. Most recent: inspection, 27 March 2025.
Documentation record
Registered dimensions (L × B × D)60.7 ft × 20.1 ft × 5.7 ft
Registered tonnagegross 61 / net 41
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS INC · STUART, FL, UNITED STATES · built 1972
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portKEY LARGO, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Gross Ton
41 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 8 November 2021
No resolution recorded
Stopped drydock / ISE inspection halfway through because of too much rot in frames, bulkheads, deck, hull planks. Must finish inspection and complete all repairs prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 May 2021
Resolved
Vessel does not have an updated CG approved NAV chart. GPS is too old to update for electronic charts. Vessel must have updated CG approved NAV chart onboard or replace GPS and update with latest software to meet requirements in NVIC 01-16
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 6 August 2021
Resolution: Operator provide photographic imagery of newly acquired "Navionics" application from mobile phone.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 4 May 2021
Resolved
Machinery guards around rotating machinery is missing on both main diesel engines. Must replace missing guards.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 6 August 2021
Resolution: Operator submitted photographic imagery of a custom built/ installed engine guard to both main diesel engines.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 4 May 2021
Resolved
Both paddles on life float were missing vessels name. Must label both paddles with vessels name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 6 August 2021
Resolution: Operator submitted photographic imagery of recently labelled lifefloat paddles, with vessel's name.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 May 2021
Resolved
2 adult life jackets were found with faded or worn retro tape. Must replace with SOLAS retro tape on both life jackets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 6 August 2021
Resolution: Operator submitted photographic imagery of 02 lifejackets with newly applied SOLAS retroflective tape.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 4 May 2021
Resolved
Captain is missing his medical cert. Must have proof of medical certifacation for his MMC to be valid.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 6 August 2021
Resolution: Operator submitted photographic imagery of newly issued medical certification.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 January 2020
Resolved
Life ring grab line is wasted. Repair/renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2020
Resolution: Grab line was renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 17 January 2020
Resolved
Life float must have vessel name and capacity on both sides.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2020
Resolution: Vessel name and capacity was added to both sides of life float.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 January 2020
Resolved
4 adult PFD’s need new reflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2020
Resolution: 04 life jackets were purchased and properly put into service.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 January 2020
Resolved
Update Coast Pilot and light list.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2020
Resolution: New coast pilot and light list were verified on board.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 January 2020
Resolved
Repair/renew electrical breaker panels and close openings.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2020
Resolution: Breaker panel openings were repaired and new hardware was used to secure front panel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 January 2020
Resolved
Close opening in console, and secure console. (Helm)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2020
Resolution: Opening in console was closed and panel was secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 January 2020
Resolved
First aid kit is missing contents, and missing inventory. Print inventory from CFR.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 January 2020
Resolution: New certified first aid kit was purchased and verified on board.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 6 February 2019
Resolved
Bilge pumps are not wired. Wire and provide proper operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2019
Resolution: Wired and operating properly.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 6 February 2019
Resolved
VHF radio must have GPS and MMSI# input. Renew/Repair
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: New Radio was installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 February 2019
Resolved
Alcohol swabs are expired. Renew
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: Renewed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 February 2019
Resolved
Remark and renew reflective tape 04 child PFD's.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: all PFDs were renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 February 2019
Resolved
Renew/Repair sound producing device.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: Renewed/Repaired
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 February 2019
Resolved
provide proper bandage for first aid kit, and renew expired contents. (Triangle bandages)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: Renewed
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 February 2019
Resolved
Rudder hardware is loose, tighten all hardware.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: Tightened
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 February 2019
Resolved
Provide 3 new fire buckets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: Provided
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 6 February 2019
Resolved
Provide PFD stowage markings to include number and size
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: Provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 February 2019
Resolved
Provide written drug testing program and signed letter for all crew enrolled.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2019
Resolution: Provided
Construction/Loadline › Structures › Deck Plating
Issued 2 February 2016
Resolved
Crop and re-new aft main deck from transom to 8' as marked.
Due 12 February 2016
Resolved 12 February 2016