This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)95.3 ft × 20.0 ft × 9.0 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1972
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portFORT MYERS BEACH, FL
Endorsements, as the file codes themcw_un, fi, rec, reg
DocumentationValid · issued 26 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton 66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 11 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each, 2 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 11
2 July 2019Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6734481
13 February 2019Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6646244
23 August 2018Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6520522
15 August 2018Administrative Inspection
Administrative · Navigation Center · Activity 6512867
21 June 2018Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6451529
11 June 2018Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6613269
15 March 2018Deadweight Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6378496
15 November 2017Examination of Repairs · COI Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6305769
7 July 2017Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6208629
2 February 2017Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6068604
Vessel has gone past hull exam due date on its COI, do not carry passengers until a satisfactory hull exam has been completed. (46CFR176.600)
Action required: 701 - Prior to carriage of passengers/cargo
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018No resolution recorded
Vsl is broadcasting: Invalid MMSI and invalid Call Sign.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2018 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 November 2017Resolved
Vessel is not ready for COI under current condition. Make ready for inspection and re-schedule. Do not carry passengers until new COI is complete. (46CFR176.600)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2018
Resolution: Completed COI, no sail cleared.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 November 2017Resolved
Fix bilge alarm light for engine room. (46CFR182.530)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2018
Resolved 16 May 2018
Resolution: Fixed light, it now functions.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 15 November 2017Resolved
Label scape hatch and attach lanyard in engine room.(46CFR185.506)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2018
Resolved 16 May 2018
Resolution: Labeled hatch and attached lanyard.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 15 November 2017Resolved
Replace junction box in forepeak. (46CFR176.800)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2018
Resolved 16 May 2018
Resolution: Replaced box.
Deck/Cargo › Holds/Tanks › Hatch
Issued 15 November 2017Resolved
Replace chain on forepeak hatch (46CFR171.630)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2018
Resolved 16 May 2018
Resolution: Repaired chain.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 15 November 2017Resolved
Replace 60 ft line and add clip to ring buoy light. (46CFR180.70)c))
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2018
Resolved 16 May 2018
Resolution: Replaced line and added clip.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 15 November 2017Resolved
Re-write station bill to be vessel specific. (46CFr185.514)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2018
Resolved 16 May 2018
Resolution: New station bill written to ecnompass all requirements.
Fire Fighting › Fire Hoses › Condition
Issued 2 February 2017Resolved
Replace two fire hoses with UL 19 approved hoses (46CFR 181.15-10(d)(1)
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 23 February 2017
Resolution: Replaced hoses with two UL 19 approved hoses.
Communications › Radio Communications › VHF Radiotelephone
Issued 2 February 2017Resolved
FCC station license is expired, replace certificate. (47CFR 80.13)
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 23 February 2017
Resolution: obtained valid FCC station license.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 2 February 2017Resolved
Alcohol test strips are expired, replace with current strips. (46CFR4.06)
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 23 February 2017
Resolution: Purchased current alcohol test kits.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 2 February 2017Resolved
Galley has two overnight accomodations, but no smoke detector, replace with UL 217 smoke detector. (46CFR181.410(e))
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 2 February 2017
Resolution: Properly installed and tested new approved smoke detector.
Construction/Loadline › Hull › Bottom Plating
Issued 15 November 2016Resolved
Heavy corrosion observed across five floor longitudinal t-frames in steering compartment, each approximately four feet long.
Action required: 705 - Other - as specified
Resolved 21 November 2016
Resolution: Frames cut out and replaced as original.
Ownership record