MAURY USCG vessel records Sign in
← All vessels

MISS ALINE

MISS ALINE is a 1998 offshore supply vessel. The Coast Guard has recorded 53 inspections since 1998, most recently in January 2026, along with 140 deficiencies, 2 operational controls and 3 casualty investigations between 2004 and 2009.

Records from 1998 to 2026. Most recent: inspection, 28 January 2026.

Built
1998
Last inspected
28 January 2026
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9191096 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDH6048
474248
Flag
MEXICO
366750490 (licence lapsed)
Maury page id
psix-474248

Inspections, by type

…with no type recorded6
Years with a record 25 calendar years (1998–2026)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)186.1 ft × 46.0 ft × 17.0 ft
Registered tonnagegross 1,099 / net 329
ITC dimensions (L × B × D)186.1 ft × 46.0 ft × 17.0 ft
ITC tonnagegross 1,099 / net 329
BuilderHALTER MARINE GROUP INC · LOCKPORT, LA, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCUT OFF, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1099 - Convention (Subpart B), Gross Ton
329 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH6048MMSI 366750490 · cancelled · compulsorily equipped · granted 23 August 2024, cancelled 17 February 2026
WDE4781MMSI 366750490 · cancelled · compulsorily equipped · granted 21 May 2008, cancelled 21 July 2014
WCY4408MMSI 366750490 · cancelled · compulsorily equipped · granted 8 June 1998, cancelled 19 May 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SOLID I Towing Vessel · MISLE 996055 · 16 December 2008 · activity 3403765SOLID II Freight Barge · MISLE 996059 · 16 December 2008 · activity 3403765

Inspection history · 53

28 January 2026 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8302671
5 February 2024 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7932541
11 September 2023 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7789245
9 August 2023 COI Inspection · Deficiency Check · Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7764336
24 May 2023 Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7719776
1 September 2022 Annual Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7549548
13 October 2021 MTSA/ISPS Verification · Deficiency Check · MARPOL Annex I Examination · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7331634
17 May 2021 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7199521
11 May 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7194675
12 November 2020 Drydock Extension · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7094778
14 October 2020 MTSA Verification · MARPOL Annex I Examination · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7078330
9 October 2019 Administrative Inspection · Deficiency Check · MARPOL Annex I Examination · MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6831171
9 October 2019 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6835775
18 July 2018 MTSA/ISPS Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6482801
27 June 2018 Administrative Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6457702
10 October 2017 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6284423
19 October 2016 Periodic Inspection · Administrative Inspection · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6025400
17 March 2016 Hull Examination · Internal Structural Exam · Cargo Tank Internal · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5835556
7 March 2016 Deadweight Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5860358
19 August 2015 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5225926
21 August 2014 Administrative Inspection · Annual Inspection · MTSA/ISPS Verification · MARPOL Annex I Examination · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4961596
6 August 2014 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4939999
21 July 2012 MARPOL Annex I Examination · DAPI Audit · Deficiency Check · Annual Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 4390859
12 July 2012 MTSA/ISPS Verification · Annual Inspection · DAPI Audit
Physical examination · Activities Europe · Activity 4388791
23 December 2009 Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Activities Europe · Activity 3661776
8 July 2009 Annual Inspection
Physical examination · Activities Europe · Activity 3527730
16 December 2008 Type not recorded
No type recorded · Activities Europe · Activity 3403765
22 August 2008 Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Activities Europe · Activity 3316790
23 April 2008 Drydock Extension · MARPOL Annex I Examination · COI Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 3175938
11 June 2007 Periodic Inspection
Physical examination · Activities Europe · Activity 2957934
4 October 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2793376
19 July 2006 Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Activities Europe · Activity 2694044
18 July 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2430976
11 July 2005 Deficiency Check · COI Inspection
Physical examination · Activities Europe · Activity 2391368
14 February 2005 Administrative Inspection
Administrative · Activities Europe · Activity 2291970
11 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290802
11 August 2004 Deficiency Check · Annual Inspection
Physical examination · Activities Europe · Activity 2123375
13 May 2004 MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 2057948
6 May 2004 Administrative Inspection
Administrative · Activities Europe · Activity 2045141
10 February 2004 Type not recorded
No type recorded · Activities Europe · Activity 2095157
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1981954
28 May 2003 Deficiency Check · Periodic Inspection · Internal Structural Exam · Hull Examination
Physical examination · Activities Europe · Activity 1778835
21 February 2003 Deficiency Check
Physical examination · Activities Europe · Activity 1741961
29 August 2002 Deficiency Check
Physical examination · Activities Europe · Activity 1654996
9 May 2002 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1614557
3 May 2002 Type not recorded
No type recorded · Activities Europe · Activity 1612263
18 September 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1072967
24 August 2001 Hull Examination · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1401546
10 April 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 23939
10 January 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1057729
1 August 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458791
14 September 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404832
29 July 1998 Initial Certification · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441417

Deficiency record · 140

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 August 2023 Resolved
If generators are arranged for parallel operation, each switchboard must have: A speed control for each prime mover.... engineer was unable to parallel because the load couldn't be split evenly between both generators.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2023
Resolved 30 August 2023
Resolution: Technician repaired. Coast Guard witnessed sat test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 August 2023 Resolved
Suitable hand covers, guards, or rails must be installed on each exposed and dangerous place, such as gears of rotating machinery, and hot surfaces. Bilge, Ballast, and fire pumps need guards installed to cover rotating shafts.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2023
Resolved 30 August 2023
Resolution: All missing guards have been installed and inspected by Coast Guard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 August 2023 Resolved
Precautions shall be taken to prevent any oil that may escape under pressure from any pump, filter, or heater from coming into contact with hot surfaces. Several Fuel fittings were missing spray shields/tape.
Condition: Improper Installation
Action required: 702 - Prior to embarking on international voyage
Due 12 September 2023
Resolved 30 August 2023
Resolution: Tape and or shields were installed on all fuel fittings/connections.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 29 August 2023 Resolved
The initial inspection of lifesaving appliances and arrangements for certification includes demonstration of the proper condition and operation of the survival craft and rescue boat launching appliance at loads ranging from light load to 10 percent overload; the rescue boat davit and falls were replaced. A 10 percent overload is require prior to launching the rescue boat.
Condition: Invalid
Action required: 702 - Prior to embarking on international voyage
Due 12 September 2023
Resolved 30 August 2023
Resolution: Witnessed sat static test @ 1.5 and sat dynamic test @ 1.1
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 29 August 2023 Resolved
Each OSV must have a communications system to immediately summon a crew member to the machinery space whenever one of the alarms required by 130.460 of this subpart activate... the sound powered phone in the engine room when dialed doesn't accurately dial where desired. Please ensure the location dialed is the location desired.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2023
Resolved 30 August 2023
Resolution: Technician tightened loose nut. Coast Guard witnessed sat test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 August 2023 Resolved
A vessel equipped with fixed pitch propellers must have on the navigation bridge and at the engine room control station a propeller speed and direction indicator for each shaft. Both the port and stbd shaft rotation indicators were inop.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2023
Resolved 30 August 2023
Resolution: shaft tachs replaced after new shafts were installed. Coast Guard witnessed sat test.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 August 2023 Resolved
Each OSV must have, at the pilot house,controls to start the fire pump, charge the fire main, and means to monitor the pressure in the fire main. The fire pump pressure gauage in the pilot house is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2023
Resolved 30 August 2023
Resolution: The sending unit to the gauge was replaced and tested.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 9 August 2023 Resolved
The internal structural members of an OSV must be examined at the same intervals required for drydocking... C&R overhead framing as marked in the port and stbd chain lockers due to wastage. C&R ladder leading to the forepeak due to wastage.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 August 2023
Resolved 30 August 2023
Resolution: Repairs were made and checked by Coast Guard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 August 2023 Resolved
Each OSV of 100 or more gross tons must be fitted with anchors and chains meeting the applicable standards set by ABS for classed vessels.... Replace both the port and stbd anchor chains due to excessive wastage
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 August 2023
Resolution: All anchor chain was renewed and inspected by Coast Guard.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 September 2022 Resolved
Vessel shall be designed, constructed and maintained to minimize fire hazards as far as reasonable and practicable. Vessel had two cable penetration areas from the machinery space to the main deck that did not have or have adequate fire protection (air from above was felt going into the machinery space.) 46CFR127.220 46CFR127.280 74SOLAS(04)II-2/9.1.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 September 2022
Resolution: Vessel installed fire stop during the inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 1 September 2022 Resolved
Vessel shall maintain watertight integrity. The forward ER watertight door allowed air to flow through the door and light was observed below on the stbd escape hatch while fully closed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 September 2022
Resolution: Vessel adjusted ER watertight door; replaced the gasket and adjusted the stbd ER escape hatch during the inspection.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 September 2022 Resolved
Vessel shall conduct fire drill and abandon ship drill on alternating weeks. Vessel was following the company drill matrix that had fire and abandon ship preformed only once a month. MI educated vessel rep and Master on required frequency.
Action required: 10 - Deficiency Rectified
Resolved 1 September 2022
Resolution: MI educated vessel rep and Master on required frequency of drills.
01 - Certificates & Documentation › 011 - Ships Certificates › International Energy Efficiency Certificate
Issued 13 October 2021 Resolved
Vessel did not maintain an IEEC. MARPOL VI 6.4
Condition: Invalid
Action required: 702 - Prior to embarking on international voyage
Due 17 November 2021
Resolved 21 December 2021
Resolution: ABS Issued IEEC w/Supplement.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 October 2020 Resolved
THIS SUBCHAPTER IS APPLICABLE TO ALL U.S. FLAG VESSELS INDICATED IN COLUMN 4 OF TABLE 2.01-7(a). VESSEL HAS BEEN OPERATING AS A LIGHTERING SUPPORT VESSEL, FENDERING FOR STS OPERATIONS. VESSEL IS CERTIFICATED UNDER 46 CFR SUBCHAPTER "L" AND THEREFORE CANNOT CONDUCT SUCH OPERATIONS WITHOUT BEING CERTIFICATED UNDER 46 CFR SUBCHAPTER "I". VESSEL IS GRANTED 90 DAYS TO OBTAIN CERTIFICATION UNDER 46 CFR SUBCHAPTER "I" TO SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 June 2021
Resolved 12 May 2021
Resolution: Vessel lost lightering contract. Multi cert process put on hold.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 October 2019 Resolved
EACH QUICK-ACTING WATERTIGHT DOOR ON A VESSEL IN OCEAN-GOING SERVICE MUST BE MADE WATERTIGHT. THE FOLLOWING DOORS AND GASKETS WERE NOT WATERTIGHT: PROVIDE AND INSTALL WATERTIGHT GASKET AND ADJUST THE QUICK-ACTING WATERTIGHT DOOR AT THE STEERING GEAR ROOM, THE BOW THRUSTER TO TANK FARM, AND PROVIDE AND INSTALL GASKET IN THE PORT AND STARBOARD ENGINE ROOM EMERGENCY ESCAPE HATCH QUICK ACTING WATERTIGHT HATCHES.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 11 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 October 2019 Resolved
REPLACE MULTIPLE MISSING HIGH PRESSURE FUEL LINE SUPPORT CLAMPS ON THE PORT MAIN DIESEL ENGINE AND REPLACE MULTIPLE MISSING HIGH PRESSURE FUEL CAPS ON THE PORT AND STARBOARD MAIN DIESEL ENGINE.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 11 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 October 2019 Resolved
LIFESAVING APPLIANCES MUST BE KEPT IN GOOD WORKING CONDITION. REPLACE DAMAGED ANTENNA ON THE EMERGENCY POSITION INDICATING BEACON.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Resolved 11 October 2019
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 October 2019 Resolved
THE VESSEL SHALL BE KEPT IN SAFE AND SEAWORTHY CONDITION FREE FROM FIRE HAZARDS. VESSEL BILGE HAS EXCESSIVE AMOUNT OF OIL. REMOVE AND PROPERLY DISPOSE OF THE OIL IN VESSEL BILGE.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 11 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 October 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 11 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 9 October 2019 Resolved
EACH EMBARKATION STATION MUST BE ADAQUATELY ILLUMINATED. VESSEL EMBARKATION LIGHTS WERE INOPERABLE. PROVIDE OPERATIONAL EMBARKATION LIGHTS ON THE PORT AND STARBOARD 01 DECK.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 11 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 9 October 2019 Resolved
LINE THROWING APPLIANCE SHALL HAVE AN AUXILIARY LINE AT LEAST 1500FT LONG. VESSEL'S AUXILLARY LINE DOES NOT MEET THE LENGTH REQUIREMENT.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 October 2019
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 October 2019 Resolved
VENT OUTLETS FOR TANKS THAT EMIT FLAMMABLE OR COMBUSTIBLE VAPORS MUST BE FITTED WITH A SINGLE SCREEN OF CORROSION RESISTENT WIRE OF AT LEAST 30X30 MECH. SEWAGE BENT OUTLET WAS MISSING FLAME SCREEN.
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 11 October 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 October 2019 Resolved
ELECTRICAL INSTALLATIONS MUST ENSURE PROTECTION OF PASSENGERS, CREW, OTHER PERSONS, AND THE VESSEL FROM ELECTRICAL HAZARDS. VESSEL HAD MULTIPLE POWER STRIPS. REMOVE ALL POWER STRIPS FROM THE VESSEL.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 October 2019
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 9 October 2019 Resolved
VESSEL IS STORING SLUDGE IN THE OILY WATER TANK AND OILY WATER IS BEING STORED IN THE SLUDGE TANK. PROPERLY DISPOSE OF CONTENTS IN THE OILY WATER TANK.
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 11 October 2019
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 9 October 2019 Resolved
ALL SHIPS OF 500GT AND UPWARDS SHALL HAVE AN OPERATIONAL GYRO COMPASS. PROVE PROPER OPERATION OF BOTH GYROS.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 11 October 2019
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 9 October 2019 Resolved
OIL RECORD BOOK (ORB) SHALL BE COMPLETED WHENEVER ANY MACHINERY SPACE OPERATIONS TAKE PLACE ON THE SHIP. THE VESSEL'S ORB HAS NOT BEEN MAINTAINED IN ACCORDANCE WITH MARPOL ANNEX 1 REG 17.2.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 October 2019
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 9 October 2019 Resolved
ANY FAILURE OF THE OIL FILTERING EQUIPMENT SHALL BE RECORDERED IN THE ORB PART 1.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 October 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 October 2019 Resolved
VESSEL'S NAME MUST BE MARKED AND CLEARLY VISIBLE ON THE PORT AND STARBOARD BOW AND STERN OF THE VESSEL. VESSEL'S NAME ON THE CERTIFICATE OF DOCUMENTATION DOES NOT MATCH THE VESSEL'S NAME ON THE HULL. ENSURE ALL DOCUMENTS MATCH WITH THE VESSEL'S CERTIFICATE OF DOCUMENTATION.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 November 2019
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 9 October 2019 Resolved
EACH VESSEL MUST BE FITTED WITH A REMOTE STOPPING DEVICE FOR EACH CARGO TRANSFER PUMP FOR COMBUSTIBLE OR FLAMMABLE LIQUID. THE MUD PUMP REMOTE STOPPING DEVICE HAS A WASTED MOUNT AND IS NOT OPERABLE. MAKE REPAIRS TO MUD PUMP EMERGENCY STOP MOUNT AND PROVE PROPER OPERATION.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 October 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 October 2019 Resolved
THE MASTER SHALL ENSURE THE VESSEL'S REQUIRED EQUIPMENT IS ONBOARD AND ALWAYS READY FOR USE. THE CO2 ROOM IS BEING USED AS A DECK AND FIRE LOCKER, CAUSING A SAFETY HAZARD OF INSPECTED EQUIPMENT. REMOVE ITEMS.
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 11 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 October 2019 Resolved
EACH MAIN ENGINE IS REQUIRED TO HAVE LOCAL MEANS TO PREVENT OPERATION OF THE ENGINE. THE PORT MAIN ENGINE LOCAL STOPPING DEVICE IS INOPERABLE. PROVE PROPER OPERATION.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 9 October 2019
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 9 October 2019 Resolved
THE OWS OVERBOARD DISCHARGE PIPE IS BROKEN AND RENDERS THE UNIT INOPERABLE. MAKE REPAIRS TO THE OWS OVERBOARD DISCHARGE PIPE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 9 October 2019 Resolved
THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS AND WITH ANY ADDITIONAL REQUIREMENTS WHICH MAY BE ESTABLISHED BY THE COMPANY. THE DEFICIENCIES FOUND DURING THE ANNUAL INSPECTION DISPLAYED A LAST IN THE VESSEL'S SAFETY MANAGEMENT SYSTEM. DEFICIENCIES WERE FOUND IN THE AREAS OF LIFESAVING, FIREFIGHTING, MARPOL, MACHINERY, AND STRUCTURAL. OBJECTIVE EVIDENCE EXIST THAT INDICATES POSSIBLE NON-CONFORMITIES OR SERIOUS FAILURE WITH THE SAFETY MANAGEMENT SYSTEM. A VERIFICATION OF THE SAFETY MANAGEMENT SYSTEM SHALL BE CONDUCTED BY THE RECOGNIZED ORGANIZATION WITHIN 14 DAYS.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2019
Resolution: External audit completed 24 Oct 2019 by ABS. Seven minor non-conformities were issued and due to be corrected by 23 Nov 2019.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 July 2018 Resolved
Provide time delays for CO2 system for bow thruster room and emergency generator room that meet required time.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2018
Resolution: Vessel provided correct time delays prior to end of inspection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 July 2018 Resolved
Provide operational CO2 nozzle in after engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2018
Resolution: Vessel provided functioning nozzle
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 18 July 2018 Resolved
Provide watertight port and STBD engine room escape hatches.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2018
Resolution: ABS Surveyor [name withheld] verified watertightness as part of Load Line Survey.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 July 2018 Resolved
Provide operational e-light in STBD escape hatch.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2018
Resolution: Vessel provided functioning e-light.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 18 July 2018 Resolved
Install OWS IAW MEPC 107(49) prior to OWS operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 19 July 2018
Resolution: Vessel provided photographic proof of proper installation.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 18 July 2018 Resolved
Provide oil record book with required entries and documentation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 July 2019
Resolved 11 October 2019
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 July 2018 Resolved
Provide functional modular smoke detectors IAW fire plan.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2018
Resolution: ABS Surveyor [name withheld] witness proper installion and function.
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 October 2017 Resolved
Vessel is required to have high bilge sensors in each space below the water line. Bilge sensor in the bow thruster room found inoperable. Replace sensor prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 October 2017
Resolved 10 October 2017
Resolution: Corrected prior to CGMI departure.
Engineering › Steering Gear System › Piping
Issued 10 October 2017 Resolved
Hoses for hydraulic steering rams found severly deteriorated and leaking. Replace hoses prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2017
Resolution: Hoses replaced and steering capability demonstrated prior to CGMI departure.
Engineering › Steering Gear System › Power Unit
Issued 10 October 2017 Resolved
Steering gear power unit and associated controls shall be operable from an alternate power source. Vessels steering gear was not operable while on emergency generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2017
Resolution: Electrican made necessary corrections to allow steering gear power unit and controls to operate properly while on E-Gen. Corrected prior to CGMI departure.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 10 October 2017 Resolved
Each lighting fixture for emergency lighting shall be makred with a 1/2 inch letter "E". Vessels emergency light was not marked throughout the vessel.
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 10 October 2017
Resolution: Vessel crew marked all lights in the presence of CGMI.
Engineering › Pressure Vessel › Relief Valve
Issued 19 October 2016 Resolved
Provide serviceable pressure relief valves for bulk cargo tanks. IAW 46CGR54.15-10 Prior to use of bulk cargo tanks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2016
Resolution: Vessel provided evidence of correction to above deficiency.
Communications › Radio Communications › VHF Radiotelephone
Issued 19 October 2016 Resolved
Provide spare battery to VHF Radiotelephone IAW SOLAS(14)III, 6.2.1.1 Prior to 21OCT16.
Due 21 October 2016
Resolved 19 October 2016
Resolution: Vessel provided a spare radio and battery.
Communications › Public Address System › Amplifier
Issued 19 August 2015 Resolved
PA system not supplied by backup emergency power.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2015
Resolution: Vessel rep provided 12VDC emergency power supply for system. Witnessed satisfactory operation.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 19 August 2015 Resolved
Insufficient transitional emergency lighting on 01 level accomdations area.
Due 2 September 2015
Resolved 20 August 2015
Resolution: Vessel provided battle lantern type emergency light for affected area. Fire plan adjusted accordingly.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 August 2015 Resolved
Middle white and lower red not under command lights burned out.
Due 2 September 2015
Resolved 20 August 2015
Resolution: Light bulbs replaced. All sat.
Lifesaving › Launching Appliances › Davit
Issued 19 August 2015 Resolved
Rescue boat davit emergency accumulator gauge unreadable.
Due 2 September 2015
Resolved 20 August 2015
Resolution: Vessel rep provided and installed new gauge of appropriate range on accumulator.
Engineering › Steering Gear System › Hydraulic Hose
Issued 19 August 2015 Resolved
Leaking hydraulic hose found on starboard steering gear.
Due 2 September 2015
Resolved 20 August 2015
Resolution: Vessel crew found hose connections insufficiently tightened. System tested under pressure post repair. All sat.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 August 2015 Resolved
Bow Thruster space bilge high level sensor junction box missing plate cover.
Due 26 August 2015
Resolved 20 August 2015
Resolution: Face plate replaced.
Operations/Management › Navigation Safety › Doors Closed at Sea
Issued 19 August 2015 Resolved
Watertight door sensor misalligned with forward machinery space watertight door resulting in inop indicator.
Due 26 August 2015
Resolved 26 August 2015
Resolution: Sensor adjusted for proper alignment.
Fire Fighting › Means of Escape › Doorways
Issued 19 August 2015 Resolved
Enegine room escape hatches both port and starboard not sufficiently easy to open from inside the vessel.
Due 26 August 2015
Resolved 20 August 2015
Resolution: Crew adjusted all dogs on both hatches and greased all fittings. Tested sat.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 19 August 2015 Resolved
Two (02) life jackets at emergency escape in engine room found discolored from soot.
Due 26 August 2015
Resolved 20 August 2015
Resolution: Crew properly washed and restowed both jackets. All sat.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 19 August 2015 Resolved
Vessel not operating with a QMED-Oiler as required by COI.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 August 2015
Resolved 19 August 2015
Resolution: Vessel rep providing Oiler from another vessel company has tied up.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 18 September 2014 Resolved
ABS to issue Safety Construction, Safety Equipment, and IAPP certificates. Vessel to provide documentation upon receiving them from ABS. Vessel limited to domestic voyages until resolved.
Action required: 705 - Other - as specified
Resolved 31 October 2014
Resolution: Vessel provided documents.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 21 August 2014 Resolved
No fire boundary doors are marked with a fire rating. Vessel reps are to provide proof to the CG that existing doors meet required structural fire protection standards.
Due 17 December 2014
Resolved 9 January 2015
Resolution: Door was replaced.
Lifesaving › Rescue Boat › Markings
Issued 21 August 2014 Resolved
Rescue boat data plate was present but not legible. Data plate needs to be replaced.
Due 17 December 2014
Resolved 25 February 2015
Resolution: Received e-mail confirmation showing new rescue boat data plate installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 August 2014 Resolved
A full function test of the fixed CO2 system located in the temporary deck equipment needs to be conducted by a qualified 3rd party contractor.
Due 31 October 2014
Resolved 26 September 2014
Resolution: A third party full function test was completed.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 6 August 2014 Resolved
Company has submitted NTVRP to MSC but has not received approval.
Due 8 September 2014
Resolved 18 September 2014
Resolution: VRP approved.
Electrical › Electric Generation Source (emergency) › Generator
Issued 21 July 2012 Resolved
Prove proper operation of emergency generator including automatic start and carriage of load w/in 45 sec. Vessel is permitted to make onway trip from Doha, Qatar to Dubai, UAE w/ follow'g conditions: 1. E/R shall be manned 2; Qualified Eng shall remain on standby at EDG in high traffic areas; c. Class to witness/attest to repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2013
Resolution: Vessel ran the generator on load and was able to show that the vessel can carry load with in 45 seconds. All Sat.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 21 July 2012 Resolved
Complete periodic safety test procedure (PTSP). A report should be provided attesting to completion and any problems found/repairs made. This report should contain the signature of the vessel Master and Chief Engineer.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 25 April 2013
Resolution: Last periodic safety test procedures was conducted on December 2012. However with the addition of the bow thruster, notified vessel rep that the automation has to be updated to include bow thruster and other methods of testing equipment should be updated
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 21 July 2012 Resolved
Prove proper operation of required safety shutdowns and alarms on main and aux diesel engines, including the emergency generator (high jacket water temperature, low lube oil pressure, overspeed, etc). If necessary, a manufacturers rep should be provided to properly demonstrate tests. A tech report from the manufacturer should be provided.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 25 April 2013
Resolution: BWAS was onboard to provide proper operation of required safety shutdowns and alarms to include high jacket water temperature and low lube oil pressure and overspeed. All Sat.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 21 July 2012 Resolved
Complete 2 hour load test of emergency generator once a month. Evidence of this test should be logged in the Engineers log book. A signed statement from the Master should be provided attesting to completion of test.
Action required: 705 - Other - as specified
Due 21 July 2012
Resolved 28 July 2012
Resolution: Received email and signed statement from Master and C/E that successful load test had been completed and logged in C/E log book. Signed statement added to MISLE documents.
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 21 July 2012 Resolved
Complete annual review of Shipboard Oil Pollution Emergency Plan (SOPEP) and submit letter certifying that review has been completed.
Action required: 705 - Other - as specified
Due 21 August 2012
Resolved 25 April 2013
Resolution: Annual review of SOPEP and submit letter certifying the review has been completed.
Communications › Public Address System › Loudspeaker
Issued 21 July 2012 Resolved
Prove proper operation of public address system.
Action required: 705 - Other - as specified
Due 28 July 2012
Resolved 30 July 2012
Resolution: Received email from Master that PA unit has been replaced and is working satisfactorily.
Electrical › Electric Generation Source (emergency) › Generator
Issued 12 July 2012 Resolved
Prove proper operation of the emergency generator.
Due 20 July 2012
Resolved 20 July 2012
Resolution: Repairs completed by Shuttle Marine Techs and witnessed by ABS Surveyor R. Grezgorowski on 20 July 12.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 12 July 2012 Resolved
Complete Periodic test procedures.
Due 21 August 2012
Resolved 4 August 2012
Resolution: Captain and Chief Engineer attested to the completion of the test procedures.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 12 July 2012 Resolved
Prove proper operation of safety shutdowns of main and aux diesel engines, High jacket water temp, low lube oil pressure, and overspeeds.
Due 21 August 2012
Resolved 6 August 2012
Resolution: catipillar tech carried out satisfactory tests.
Electrical › Electric Generation Source (emergency) › Generator
Issued 12 July 2012 Resolved
Complete 2 hour test of emergency generator.
Due 21 August 2012
Resolved 28 July 2012
Resolution: Two hour load test carried out 28 July and will be completed and logged monthly.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 12 July 2012 Resolved
Complete annual reviw of SOPEP.
Due 21 August 2012
Resolved 3 August 2012
Resolution: review completed.
Communications › Public Address System › Loudspeaker
Issued 12 July 2012 Resolved
Prove proper operation of the PA system.
Due 12 August 2012
Resolved 30 July 2012
Resolution: Shuttle Marine replaced and tested the PA system.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 23 April 2008 Resolved
Properly reflect load line markings IAW the International Load Line Certificate.
Condition: Unknown
Due 24 May 2008
Resolved 24 April 2008
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 April 2008 Resolved
Properly attach lines on all ring buoys w/ lights attached throughout the vessel.
Condition: Improper Installation
Due 24 May 2008
Resolved 24 April 2008
Fire Fighting › Ventilation Systems › Ducts
Issued 23 April 2008 Resolved
Replace all damaged gaskets on all fire vent covers throughout the vsl.
Condition: Damaged By Earlier Event
Due 24 May 2008
Resolved 24 April 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 23 April 2008 Resolved
Replace shackle on P/S pilot ladder.
Condition: Unknown
Due 24 May 2008
Resolved 24 April 2008
Resolution: Cleared by attending Marine Inspector.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 23 April 2008 Resolved
Remove all flammables located in storage locker IWO galley.
Due 24 May 2008
Resolved 24 April 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 23 April 2008 Resolved
Repair P/S deck flood light and S/S quarter anchor light. [name withheld] reported this item as corrected in an e-mail dated, May 23, 2008. The compliance due date was changed to July 8, 2008 to correspond with the drydock exam date scheduled, where an ACTEUR MI will confirm correction of this CG-835.
Condition: Unknown
Due 8 July 2008
Resolved 22 August 2008
Stability › Watertight Integrity › General
Issued 23 April 2008 Resolved
Install door closures on watertight doors leading to aft steering and bow thruster compartment. [name withheld] reported this item as corrected in an e-mail dated, May 23, 2008. The compliance due date was changed to July 8, 2008 to correspond with the drydock exam date scheduled, where an ACTEUR MI will confirm correction of this CG-835.
Condition: Unknown
Due 8 July 2008
Resolved 12 June 2008
Resolution: Rcvd e-mail from Captain of the vsl attesting to properly resolving this CG-835.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 April 2008 Resolved
Provide eyewash bottles for engine compartment. [name withheld] reported this item as corrected in an e-mail dated, May 23, 2008. The compliance due date was changed to July 8, 2008 to correspond with the drydock exam date scheduled, where an ACTEUR MI will confirm correction of this CG-835.
Condition: Unknown
Due 8 July 2008
Resolved 22 August 2008
Engineering › Fuel Oil Service System › Piping
Issued 23 April 2008 Resolved
Repair fuel & oil leaks on starboard generator. [name withheld] reported this item as corrected in an e-mail dated, May 23, 2008. The compliance due date was changed to July 8, 2008 to correspond with the drydock exam date scheduled, where an ACTEUR MI will confirm correction of this CG-835.
Due 8 July 2008
Resolved 22 August 2008
Engineering › Freshwater System (jacketwater cooling) › Storage Tank
Issued 23 April 2008 Resolved
Repair leaking flexible coupling on port main. (F/W expansion tank) [name withheld] reported this item as corrected in an e-mail dated, May 23, 2008. The compliance due date was changed to July 8, 2008 to correspond with the drydock exam date scheduled, where an ACTEUR MI will confirm correction of this CG-835.
Condition: Unknown
Due 8 July 2008
Resolved 22 August 2008
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 23 April 2008 Resolved
Replace inoperable e-light battle lanterns throughout the vessel. [name withheld] reported this item as corrected in an e-mail dated, May 23, 2008. The compliance due date was changed to July 8, 2008 to correspond with the drydock exam date scheduled, where an ACTEUR MI will confirm correction of this CG-835.
Condition: Unknown
Due 8 July 2008
Resolved 22 August 2008
Lifesaving › Launching Appliances › Davit
Issued 23 April 2008 Resolved
Replace falls and conduct 1.1 load test of davit winch and release gear. Conduct rescue boat launching appliance servicing by manufacturer and/or manufacturer's certified representative [name withheld] reported this item as corrected in an e-mail dated, May 23, 2008. The compliance due date was changed to July 8, 2008 to correspond with the drydock exam date scheduled, where an ACTEUR will confirm.
Due 8 July 2008
Resolved 12 June 2008
Resolution: Rcvd e-mail from Captain of the vsl attesting to properly resolving this CG-835.
Engineering › Fuel Oil Service System › Valve
Issued 23 April 2008 Resolved
Prove proper operation of the fuel oil & lube oil emergency shutdown stop, outside CO2 compartment.
Condition: Unknown
Due 24 May 2008
Resolved 24 April 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 23 April 2008 Resolved
Provide manufacturer's manual for fixed fire fighting system onboard the vessel. [name withheld] reported this item as corrected in an e-mail dated, May 23, 2008. The compliance due date was changed to July 8, 2008 to correspond with the drydock exam date scheduled, where an ACTEUR MI will confirm correction of this CG-835.
Condition: Unknown
Due 8 July 2008
Resolved 22 August 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 23 April 2008 Resolved
Conduct proper servicing test of fixed fire fighting system onboard vessel with manufacturer's manual in the presence of a USCG marine inspector. [name withheld] reported this item as corrected in an e-mail dated, May 23, 2008. The compliance due date was changed to July 8, 2008 to correspond with the drydock exam date scheduled, where an ACTEUR MI will confirm correction of this CG-835.
Due 8 July 2008
Resolved 11 July 2008
Resolution: Permission was given by CID that Wilhelmsen Ship Service (UNITOR) could conduct servicing with out CG oversight. Servicing Report was provided and confirmation that CO2 was used was included.
Lifesaving › Rescue Boat Equipment › Searchlight
Issued 20 June 2007 Resolved
Repair or replace the rescue boat search light. [name withheld] reported this item as corrected in an e-mail dated June 28, 2007. The compliance due date was changed to July 30, 2008 to correspond with the COI expiration date.
Due 30 July 2008
Resolved 22 August 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 20 June 2007 Resolved
Install a Coast Guard approved, Marine Grade fire extinguisher for the rescue boat. [name withheld] reported this item as corrected in an e-mail dated June 28, 2007. The compliance due date was changed to July 30, 2008 to correspond with the COI expiration date.
Due 30 June 2008
Resolved 22 August 2008
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 19 July 2006 Resolved
Supply Proof of the onboard fuel hose have met the requirement for annual hydrostatic pressure test. Report cleared via E-mail dated 01Aug06, Item remains open until cleared by attending Marine Inspector at next annual
Condition: Improper/Lack of Maintenance
Due 30 October 2007
Resolved 14 September 2015
Resolution: Error in MISLE 5.0 transfer
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 19 July 2006 Resolved
Supply Proof of the SOPEP having met the requirement for annual review. Report cleared via E-mail dated -1Aug06, Item remains open until cleared by attending Marine Inspector at next annual.
Due 30 October 2007
Resolved 20 June 2007
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 19 July 2006 Resolved
Supply Proof of the of a SMC being issued by ABS.
Action required: 705 - Other - as specified
Due 18 August 2006
Resolved 28 August 2006
Resolution: New SMC issued and submitted to CSR desk.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 August 2004 Resolved
Make repairs to GMDSS and provide copy of servicing report no later than 25AUG04.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 August 2004
Resolved 7 September 2004
Resolution: Received copy of servicing report dtd 22AUG04 from NAVCOM-Doula.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 11 August 2004 Resolved
Conduct hydro test of the fuel transfer hose as per 33 CFR 156.170 and marked in accordance with 154.500.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 August 2004
Resolved 7 September 2004
Resolution: Rcvd e-mail from vsl master [name withheld] attesting to the completion.
Construction/Loadline › Hull › Hull Plating
Issued 11 August 2004 Resolved
Make repairs if necessary at next drydocking to the insets on stbd side shell aft in way of the stbd fresh water tank. Approximately 11 in. above the waterline
Condition: Damaged By Earlier Event
Due 29 July 2006
Resolved 19 July 2006
Resolution: Area reinspected and deemed not needing repairs. Note placed in MISLE to re-inspect at next DD.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 11 August 2004 Resolved
Service fixed CO2 fire extinguishing system as required by 46 CFR 132.350(c)(2) or show proof that the last servicing in 26JUL04 was completed in accordance with the above regulations.
Condition: Unknown
Due 11 September 2004
Resolved 19 August 2004
Resolution: Recived electronically copy of corrected servicing report.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 11 August 2004 Resolved
Provide proof of required drug testing for the crew has been conducted in accordance with 46 CFR 16.260 and copy of past year data report CG-5573 as required by 46 CFR 16.500(b).
Condition: Unknown
Due 11 September 2004
Resolved 11 July 2005
Resolution: Unit DAPI officer advised closed def. Vessel does not meet requirements while located in West Africa.
Documentation › Safety/Response Plans/Programs
Issued 3 August 2003 Resolved
Update Fire Safety Plan 1.Heat sensor located port side, main deck by the head 2. CO2 system for emergency generator 3. CO2 release for the emergency generator. 4. Update number of Fire Plans with locations on legend LEGACY COMPONENT DESC: Fire Control Plans
Due 3 September 2003
Resolved 15 September 2003
Resolution: Received new set of Fire Safety Plans. Corrections made but plans have not been approved by MSC
Fire Fighting › Nozzles › Number
Issued 3 August 2003 Resolved
Ensure water fog applicator is on board and stored properly.
Condition: Unknown
Due 3 September 2003
Resolved 12 August 2003
Resolution: Received email from the Port Engineer stating the water fog applicator as been placed onboard and stored as per the Fire Safety Plan.
Lifesaving › Lifebuoys
Issued 3 August 2003 Resolved
Vessel must install a "quick release" life ring on the navigational bridge as required by SOLAS III, Regulation 7 1.3. Received attestation from the master that the above item was corrected. Extended one year. LEGACY COMPONENT DESC: Self-Activitating Smoke Signals
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 14 September 2015
Resolution: Corrected and operational. Error in MISLE 5.0 transfer
Stability › Watertight Integrity
Issued 28 May 2003 Resolved
1. Gooseneck vent internals worn and loose in housing. Renew worn parts and propely assemble vents. LEGACY COMPONENT DESC: Gooseneck vents
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 22 December 2003
Resolution: Received attestation from the master that the above item was corrected.
Lifesaving › Inflatable Liferafts
Issued 28 May 2003 Resolved
2. Liferafts due for annual servicing. Properly service inflatable life rafts at a US Coast Guaard approved service station.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 3 August 2003
Resolution: Reviewed liferaft service reports
Lifesaving › Rescue Boat
Issued 28 May 2003 Resolved
3. Provide U.S. Coast Guard Approved SOLAS Rescue Boat vice non-approved Zodiac Boat
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2003
Resolved 3 August 2003
Resolution: Inspected the rescue boat: Zodiac Hurricane (Model H472S - 160.156/8/0). Rescue boat has all associated required SOLAS equipment.
Lifesaving › Launching Appliances
Issued 28 May 2003 Resolved
4. Submit evidence of U.S. Coast Guard Approval and affix U.S. Coast Guard Approval Plate to davit and winch assemblies. LEGACY COMPONENT DESC: Davit
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2003
Resolved 3 August 2003
Resolution: Received email from MSC stating the rescue boat davit/winch was accepted. Conducted 10% overload test on the installed davit and winch for the rescue boat. Test weight used was 2650 lbs. Plates on the davit & winch stamped with the CG propeller.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 28 May 2003 Resolved
5. Submit plan for MSC approval for the modifications made to the fire dection systems. On February 20, 2004 rcvd a copy of the MSC-2 Ltr stating the Fire detection system plans have been reviewed and returned "approved". Test of system must be demonstrated to the satisfaction of the OCMI
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 11 August 2004
Fire Fighting › Remote Fuel Shutoff
Issued 28 May 2003 Resolved
6. Plan submitted for approval of the emergency generator does not show remote shut off outside the space. Provide remote shut off valve for the fuel tank located outside the space IAW 46CFR56.50-60(d).
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2003
Resolved 3 August 2003
Resolution: Corrected during follow up inspection
Engineering › Fuel Oil Storage/Transfer System
Issued 28 May 2003 Resolved
7. Material specification for the independent fuel tank omitted from submitted plan. Provide specifications for the fuel tank material and verify acceptance. LEGACY COMPONENT DESC: Tank
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2004
Resolved 23 January 2004
Resolution: Inspected plan review stamped by ABS.
Engineering › Fuel Oil Storage/Transfer System
Issued 28 May 2003 Resolved
8. Baffles omitted from submitted plan for emergency generator independent fuel tank. Provide baffles for fuel tank IAW 46CFR 58.50-10(a)(7). Received attestation from the master that the above item was corrected. Attended vessel and found the baffles were not installed. LEGACY COMPONENT DESC: Tank
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 11 February 2004
Resolution: Received photographs of installed baffles in tank.
Engineering › Fuel Oil Storage/Transfer System
Issued 28 May 2003 Resolved
9. Prior to installation test the independent fuel tank to 5 pounds per square inch (PSI) or 1 1/2 times the ,aximum head to which the tank may be subjected which ever is greater.Received attestation from the master that the above item was corrected. Extended one year. LEGACY COMPONENT DESC: Tank
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 23 March 2004
Resolution: View service report while on board in Malabo EG.
Engineering › Fuel Oil Storage/Transfer System
Issued 28 May 2003 Resolved
10. Fuel tank plan shows opening in the side of the tank. 46CFR58.50-10(a)(4)does not permit openings in the bottom side or ends of the tank except as per (i) (ii). Fabricate the tank in compliance with 46CFR58.50-10.Received attestation from the master that the above item was corrected. LEGACY COMPONENT DESC: Tank
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 July 2004
Resolved 23 January 2004
Resolution: Opening was moved to the top of the tank. View while onboard in Malabo EG.
Operations/Management › Lifesaving
Issued 28 May 2003 Resolved
11. Upon installation of U.S. Coast Guard Rescue Boat Davit and Rescue Boat conduct installation test with US Coast Guard Marine Inspector in attendance. LEGACY COMPONENT DESC: Op Readiness/Maintenance/Inspection
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 3 August 2003
Resolution: Conducted 10% overload test on the installed davit and winch for the rescue boat. Test weight used was 2650 lbs. The condition B weight for the Zodiac Hurricane (Model H472S): 1840 lbs. Weight test conducted for 10 minutes.
Lifesaving › Lifejacket/PFD (General)
Issued 28 May 2003 Resolved
12. Provide U.S. Coast Guard SOLAS Approved Life Preservers to replace the "coastwise" life preservers on board. LEGACY COMPONENT DESC: Quantity
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2003
Resolved 3 August 2003
Resolution: All life preservers meet SOLAS requirements/approval.
Accommodation/Occupational Safety
Issued 28 May 2003 Resolved
13. Provide EEBDs as requied for the machinery spaces.
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 3 August 2003
Resolution: EEBDs were provided at exit in the machinery spaces.
Engineering › Pressure Vessel
Issued 28 May 2003 Resolved
14. Examine or test starting air receivers in accordance with 46CFR 61.10-5
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 22 December 2003
Resolution: Received attestation from the master that the above item was corrected.
Construction/Loadline › Hull
Issued 28 May 2003 Resolved
15. Open make safe for entry #1, #2 starboard fuel tanks examine and repairdamage to side shell and internals as required. LEGACY COMPONENT DESC: Side Shell
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 22 December 2003
Resolution: Received attestation from the master that the above item was corrected.
Documentation › Safety/Response Plans/Programs
Issued 28 May 2003 Resolved
16. Update safety plan to reflect modifications made to the vessel. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 3 August 2003
Resolution: Reviewed Fire Safety plans aboard the vessel. Plans not reviewed by MSC or this office. Issued new requirement
Construction/Loadline › Hull
Issued 28 May 2003 Resolved
17. Crop and renew buckled swash bulkheads portside aft peak tank in way of transom.
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 22 December 2003
Resolution: Received attestation from the master that the above item was corrected.
Documentation › Certificates/Documents
Issued 29 August 2002 Resolved
Provide a valid FCC Safety Radio Certificate for the vessel. LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Due 29 September 2002
Resolved 23 April 2003
Documentation › Certificates/Documents
Issued 29 August 2002 Resolved
Post COI and Stability letter or have readily available. LEGACY COMPONENT DESC: Certificate of Inspection
Due 29 August 2002
Resolved 23 March 2003
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 29 August 2002 Resolved
Submit Fire and Safety Plan to MSC for review.
Condition: Unknown
Due 1 June 2003
Resolved 11 August 2004
Fire Fighting › Structural Fire Protection - General
Issued 29 August 2002 Resolved
Make door to Engine room from Galley self closing.
Due 29 August 2002
Resolved 23 March 2003
Construction/Loadline › Markings
Issued 29 August 2002 Resolved
Paint the Loadline deck reference mark in constrasting color to the hull. LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper/Lack of Maintenance
Due 29 September 2002
Resolved 23 March 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 29 August 2002 Resolved
Install Safety chain around Rescue boat storage location. LEGACY COMPONENT DESC: Lifeline
Due 29 September 2002
Resolved 23 April 2003
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 29 August 2002 Resolved
Provide proof of required drug testing for all crewmembers in accordance with 46 CFR Part 16. LEGACY COMPONENT DESC: Employee Coverage
Condition: Unknown
Due 1 September 2003
Resolved 11 August 2004
Navigation › Collision/Grounding Avoidance
Issued 9 May 2002 Resolved
PROVIDE CERTIFICATE OF ALTERNATIVE COMPLIANCE FOR NAVIGATION LIGHT PLACEMENT OR PROPERLY MOUNT ALL NAVIGATION LIGHTS LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 June 2002
Resolved 29 August 2002
Pollution Prevention/Response › Prevention Equipment
Issued 9 May 2002 Resolved
PROVIDE AND POST LIQUID MUD TRANSFER PROCEDURES, VESSEL SPECIFIC TANK, PIPING, VALVES, AND PUMP SCHEMATIC LEGACY COMPONENT DESC: TRANSFER PROCEDURES
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2002
Resolved 29 August 2002
Documentation › Certificates/Documents
Issued 9 May 2002 Resolved
PROVIDE IOPP CERTIFICATE LEGACY COMPONENT DESC: IOPP Certificate
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2002
Resolved 29 August 2002
Lifesaving › Rescue Boat
Issued 9 May 2002 Resolved
END FOR END RESCUE BOAT DAVIT CABLE. LEGACY COMPONENT DESC: DAVIT
Condition: Improper/Lack of Maintenance
Due 9 June 2002
Resolved 29 August 2002
Pollution Prevention/Response › Prevention Equipment
Issued 9 May 2002 Resolved
PRIOR TO TRANSFERRING, (INTERNAL OR EXTERNAL) AND COMBUSTIBLE OR FLAMMABLE LIQUID MUD INSTALL FLAME SCREENS IN ALL LIQUID MUD TANK VENTS LEGACY COMPONENT DESC: FLAME SCREENS
Condition: Improper/Lack of Maintenance
Due 29 August 2002
Resolved 23 April 2003
Lifesaving › Lifebuoys
Issued 9 May 2002 Resolved
INSTALL RETRO-REFLECTIVE TAPE ON STBD MAINDECK AFT LIFERING LEGACY COMPONENT DESC: RETRO-REFLECTIVE TAPE
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 9 May 2002
Resolved 9 May 2002
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 9 May 2002 Resolved
REPAIR F/O LEAK AT THE HAND STRIPPING PUMP.
Condition: Improper/Lack of Maintenance
Due 9 May 2002
Resolved 9 May 2002
Construction/Loadline › Structures › Door
Issued 9 May 2002 Resolved
PROPERLY REPAIR CLOSURE DEVICE FOR THE ENGINE ROOM PORT SIDE ESCAPE FIRE DOOR.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 9 May 2002
Resolved 9 May 2002
Pollution Prevention/Response › Prevention Equipment
Issued 9 May 2002 Resolved
REPAIR F/O PURIFIER REMOTE SHUTDOWN LEGACY COMPONENT DESC: REMOTE SHUTDOWN F/O PURIFIER
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2002
Resolved 9 May 2002
Navigation › Piloting/Steering
Issued 9 May 2002 Resolved
ADD STEERING CHANGE-OVER INSTRUCTIONS AT THE EMERGENCY STEERING STATION. THIS ITEM WAS ALSO LISTED ON INSP CONDUCTED ON 01 AUG 00. LEGACY COMPONENT DESC: STEERING INSTRUCTIONS
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 June 2002
Resolved 29 August 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 May 2002 Resolved
REMOVE ALL EXTENSION CORDS SERVING AS PERMANENT WIRING.
Condition: Improper Installation
Due 9 May 2002
Resolved 9 May 2002
Fire Fighting
Issued 24 August 2001 Resolved
RENEW/REPAIR THE SENDING UNIT USED FOR THE FIRE PUMP PRESSURE GAUGE LOCATEDON THE BRIDGE.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 14 September 2015
Resolution: Error in MISLE 5.0 transfer
Electrical
Issued 24 August 2001 Resolved
INSTALL AN APPROVED EMERGENCY LIGHT IN THE VICINITY OF THE STBD SHIP SERVICE GENERATOR, AND DIRECT THE LIGHT BEAM DOWN THE LADDER.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 14 September 2015
Resolution: Error in MISLE 5.0 transfer
Electrical
Issued 24 August 2001 Resolved
RENEW THE BATTERY CHARGER, USED FOR THE EMERGENCY EMBARKATION LIGHTING SYSTEM.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 14 September 2015
Resolution: Error in MISLE 5.0 transfer
Fire Fighting
Issued 24 August 2001 Resolved
PROVIDE AN APPROVED AND LEGIBLE FIRE CONTROL PLAN.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 14 September 2015
Resolution: Error in MISLE 5.0 transfer

Casualty record · 3

10 February 2004Routine · role: Involved in a Marine Casualty · activity 2095157
16 December 2008Routine · role: Subject to Marine Inspection · activity 3403765
20 November 2009Routine · role: Involved in a Marine Casualty · activity 3652286
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SEABULK ARIZONA (2004–2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.