JOURNEY

JOURNEY is a 1968 passenger vessel (inspected). The Coast Guard has recorded 88 inspections since 1986, most recently in February 2026, along with 177 deficiencies and 2 operational controls.

Records from 1986 to 2026. Most recent: inspection, 5 February 2026.

Built
1968
Last inspected
5 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK7977
Flag
UNITED STATES
367170240
Maury page id
psix-47436

Inspections, by type

…with no type recorded11
Years with a record 38 calendar years (1986–2026)
The 88 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)39.3 ft × 14.8 ft × 7.0 ft
Registered tonnagegross 26 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHATTERAS YACHT DIVISION · HIGH POINT, NC, UNITED STATES · built 1968
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHUNTINGTON, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 4 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Regulatory (Subpart C or D), Net Ton
26 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK7977MMSI 367170240 · active · compulsorily equipped · granted 25 April 2019, expires 25 April 2029
WDD6241MMSI 367170240 · expired · compulsorily equipped · granted 2 March 2007, cancelled 6 May 2017
WUY5878MMSI not assigned · expired · compulsorily equipped · granted 19 July 1994, cancelled 26 September 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 88

5 February 2026 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8276300
28 January 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8051028
30 October 2024 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7909431
17 November 2023 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7807014
23 January 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7591634
25 October 2022 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7477244
16 October 2022 Type not recorded
No type recorded · Station Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7578493
18 January 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7382129
25 January 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7129261
2 November 2020 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7088957
13 January 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6866375
11 April 2019 Simplified Stability Test
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6661210
1 July 2018 Hull Examination · COI Inspection · In-Service Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6559630
22 May 2018 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6420171
21 September 2017 Administrative Inspection · DAPI Audit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6274501
4 May 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6138836
17 August 2016 Administrative Inspection · Deficiency Check · Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5977434
18 February 2016 COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5815827
2 May 2014 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4852911
15 February 2012 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4245301
1 February 2011 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3937330
25 January 2010 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3667031
23 June 2008 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3245873
19 March 2008 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3162568
16 January 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3115870
27 March 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2896347
26 February 2007 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2876527
13 March 2006 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2599284
23 January 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2569371
17 May 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2345831
21 March 2005 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2269311
22 April 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2050398
31 March 2004 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2012436
6 March 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1753829
18 February 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1740350
15 March 2002 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1493828
11 February 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1480420
8 February 2001 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1376448
19 July 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1401330
10 May 2000 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1457789
20 April 2000 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1051001
15 June 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 809986
12 April 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 788743
26 March 1998 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1438709
13 February 1998 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1368589
2 October 1997 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 784794
16 September 1997 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1107610
23 April 1997 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1096833
16 April 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1431757
20 May 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1083822
14 March 1996 Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1390242
13 March 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1396502
3 June 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 710848
3 April 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 204564
22 February 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 850773
17 February 1995 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 846122
9 June 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1324015
28 April 1994 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1444839
27 April 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 213457
5 April 1994 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1165898
18 February 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1166693
24 July 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 215778
18 May 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 831574
29 April 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1146410
23 April 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1141747
15 March 1993 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 835811
24 November 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 828959
23 November 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 827488
14 July 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1012723
20 March 1992 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1011546
6 March 1992 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 957843
24 October 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 938107
28 June 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1236717
13 May 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 911644
14 March 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1307578
4 March 1991 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 931867
5 April 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1217229
6 March 1990 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1219934
5 March 1990 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 926383
12 May 1989 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 888816
16 March 1989 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1274139
6 March 1989 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1274541
18 October 1988 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 887527
27 April 1988 Deficiency Check · Drydock Extension · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1350986
20 April 1987 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1312058
11 June 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1306341
26 April 1986 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 995030
9 April 1986 Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1308972

Deficiency record · 177

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 November 2023 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The battery of the vessel's EPIRB is expired. The vessel may not transit more than three miles from the coastline with passengers until a new battery has been installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 November 2023
Resolution: Vessel provided an operational EPIRB with a new battery.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 17 November 2023 Resolved
Employers must ensure that they and their crewmembers meet the requirements of this part (46 CFR 16). While conducting a DAPI audit, it was noted that numerous requirements of the chemical testing program were missing.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2023
Resolved 4 December 2023
Resolution: Operator provided DAPI documentation leading to a successful company program audit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 January 2021 Resolved
Each child sized life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. Found child life jackets to be stored loosely in the same storage containers as adult life jackets. Provide means to clearly separate child and adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2021
Resolved 1 February 2021
Resolution: Vessel moved child lifejackets to the aft main deck, behind the operating station in an appropriately marked and float free location, separate from adult lifejackets.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 25 January 2021 Resolved
As appropriate for intended voyage, a vessel must carry adequate and up to date: charts, coast pilot, light list, tide tables, and current tables. Found vessel to be missing light list, tide tables, and current tables and the coast pilot issued in 2005. Provide updated publications.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2021
Resolved 3 February 2021
Resolution: Vessel replaced outdated publications and provided an up to date coast pilot, light light, tide tables and currents tables.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 January 2021 Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke distress signals. Found vessel had only four of each. Vessel replaced missing distress flares prior to MI departing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 January 2021
Resolution: Rectified to the satisfaction of the attending marine inspector prior to departure.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 January 2020 Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The remote fuel shutoff valve for the port fuel tank found inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2020
Resolution: Vessel replaced valve handle and operational tested, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 January 2020 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Forward bilge inoperable.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2020
Resolution: Vessel proper connected hose and operationally tested sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 13 January 2020 Resolved
At each inspection for certification and at every other vessel inspection, all observed unsafe practices fire hazards and other hazardous situations must be corrected, and all required guards and protective devices must be in satisfactory condition. Forward through hull valve not properly secured/capped.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2020
Resolution: vessel properly secured/capped valve.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 13 January 2020 Resolved
A vessel must comply with the applicable requirements for any radio installation, including installation certificates to be issued by the federal communications commission, as set forth in 47 CFR part 80. Vessel to provide radio telephony safety certification and FCC radio operator license. Vessel is restricted to 1000 feet from shore.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2020
Resolved 30 January 2020
Resolution: Vessel had onboard all required FCC certificates
Lifesaving › Hand Flares › Quantity
Issued 22 May 2018 Resolved
Required two additional red and orange flares each, or 4 additional red flares, to meet requirements of LC route.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2018
Resolved 29 May 2018
Engineering › Bilge Water Management System › Pump
Issued 22 May 2018 Resolved
Lazarette bilge pump automatic float switch not operating.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2018
Resolved 29 May 2018
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 21 September 2017 Resolved
Renew vessel's Certificate of Documentation (COD). 46 CFR 67.161
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2017
Resolved 23 May 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 September 2017 Resolved
Annual servicing of Pre-engineered fire system in engine room. 46 CFR 176.810(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2017
Resolved 23 May 2018
Communications › Radio Communications › EPIRB
Issued 21 September 2017 Resolved
Installed EPIRB needs to be registered with NOAA and Hydrostatic unit replaced.46 CFR 180.64 46 CFR 185.740
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 23 May 2018
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 21 September 2017 Resolved
Update Drug and Alcohol testing program.46 CFR 16.401
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 22 May 2018
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 September 2017 Resolved
Ensure all battery terminal connections are of a permanent type(No wing-nuts).46 CFR 183.05-20(c) (old T)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 23 May 2018
Lifesaving › Hand Flares › Expired
Issued 21 September 2017 Resolved
Provide three red hand flares and three hand orange smoke signals, or six red hand flares. 46 CFR 180.68(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 23 May 2018
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 21 September 2017 Resolved
Replace port side fuel tank ball valve.46 CFR 182.20-40
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 23 May 2018
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 21 September 2017 Resolved
Replace port side fuel tank fill clamps.46 CFR 182.20-40
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 25 September 2017
Engineering › Lubricating Oil Service System › Hose
Issued 21 September 2017 Resolved
Replace port side SAE hoses showing signs of wear.46 CFR 182.20-40
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 23 May 2018
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 21 September 2017 Resolved
Perform Fire and Man Overboard drills in the presence of a Marine Inspector.46 CFR 185.524 46 CFR 185.520
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 23 May 2018
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 18 February 2016 Resolved
Fixed firefighting system CO2 bottle located in engine space may not be inclined more than 30 degrees from the vertical position. 46 CFR 181.410(c)(7)
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 8 August 2016
Resolution: CO2 Bottle is fitted with flexible or bent siphon tubes, in which case it may be inclined not more than 80° from the vertical position. Bottle was raised 15 degrees from horizontal or is 75 degrees from vertical.
Fire Fighting › Means of Escape › Blocked
Issued 18 February 2016 Resolved
Emergency escape routes must be rapidly accessible and free from obstruction. Remove decorative netting leading to, and furniture located directly above aft emergency escape hatch. 46 CFR 177.500(h)
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 18 August 2016
Fire Fighting › Means of Escape › Escape Route Signs
Issued 18 February 2016 Resolved
All emergency exits must be marked clearly on both sides with at least 2 inch lettering, “EMERGENCY EXIT, KEEP CLEAR”. Properly mark both forward and aft emergency exits. 46 CFR 185.606
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 18 August 2016
Lifesaving › Visual Distress Signals (General) › Expired
Issued 18 February 2016 Resolved
All three water lights, for lifebuoy and lifefloat, onboard were found with expired batteries. Replace with new batteries. 46 CFR 185.726(c)
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 18 August 2016
Lifesaving › Lifefloat › Markings
Issued 18 February 2016 Resolved
Vessel name and number of persons the device is equipped for must be clearly marked on each lifefloat. Legibly mark vessel name and capacity on large lifefloat. 46 CFR 185.604(a)(2) / 46 CFR 185.604(e)(1)
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 18 August 2016
Lifesaving › Lifefloat › Retroreflective Material
Issued 18 February 2016 Resolved
Each rescue boat and lifebuoy must be marked with retro reflective material. Replace reflective tape on lifebuoy and large lifefloat. 46 CFR 185.604(i)
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 18 August 2016
Fire Fighting › Fire Bucket › Capacity
Issued 18 February 2016 Resolved
Vessel must have three 2.5 gallon fire buckets with attached lanyard, easily available for emergency. One bucket onboard was 5 gallons in capacity with insufficient lanyard. All buckets onboard were stowed below deck behind bar. Replace 5 gallon bucket (or add) with 2.5 gallon bucket. Relocate all fire buckets in more readily accessible location. 46 CFR 181.610
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 18 August 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 2 May 2014 Resolved
Provide emergency broadcase placard.
Due 2 June 2014
Resolved 2 May 2014
Navigation › Piloting/Steering › Marine Charts
Issued 2 May 2014 Resolved
Provide current nautical chars and pubs for route.
Action required: 705 - Other - as specified
Due 2 June 2014
Resolved 3 June 2014
Resolution: Charts and pubs provided.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 2 May 2014 Resolved
Provide correct lifejacket placard.
Due 2 June 2014
Resolved 2 May 2014
Documentation › Logs/Records › Drug Test Records
Issued 2 May 2014 Resolved
Provide proof of current drug and alcohol program requirements.
Due 2 June 2014
Resolved 23 May 2014
Lifesaving › Rocket Parachute Flares › General
Issued 1 February 2011 Resolved
Provide 6 red and 6 orange hand flares prior to exceeding voyages to more than 30 minuets in duration.
Action required: 705 - Other - as specified
Resolved 8 April 2011
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 February 2011 Resolved
Provide 60' lifeline for onboard ringbuoy.
Due 4 March 2011
Resolved 8 April 2011
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 1 February 2011 Resolved
Provide 1 additional child lifejacket. Vessel may not carry more than 30 passengers until completed.
Action required: 705 - Other - as specified
Resolved 25 April 2011
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 February 2011 Resolved
Provide labeled storage for all child lifejackets.
Due 4 March 2011
Resolved 8 April 2011
Engineering › Lubricating Oil Service System › Hose
Issued 1 February 2011 Resolved
Renew damaged oil line on the port MDE.
Action required: 705 - Other - as specified
Resolved 8 April 2011
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 1 February 2011 Resolved
Remove all oil and debris from all bilges.
Due 15 March 2011
Resolved 8 April 2011
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 1 February 2011 Resolved
Properly mount all new fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2011
Fire Fighting › Fire Bucket › Quantity
Issued 25 January 2010 Resolved
Provide (3) 2.5 gallon fire buckets.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 February 2010
Resolved 24 February 2010
Resolution: Operator provided photo with three 2.5 gallon fire buckets provided.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 25 January 2010 Resolved
Provide throwable ring buoy marked with Type II retroreflective material.
Action required: 705 - Other - as specified
Due 22 February 2010
Resolved 24 February 2010
Resolution: Operator provided photo for proof of retro application.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 January 2010 Resolved
Provide an 18 FT waterlight lanyard for lifefloat.
Action required: 705 - Other - as specified
Due 22 February 2010
Resolved 24 February 2010
Resolution: Operator provided photo with 18 FT waterlight lanyard for lifefloat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 January 2010 Resolved
Provide machinery guard on STBD main engine.
Action required: 705 - Other - as specified
Due 8 March 2010
Resolved 2 March 2010
Resolution: Operator provided photo of the machinery guard in place on the STBD main engine.
Engineering › Fuel Oil Service System › Hose
Issued 25 January 2010 Resolved
Provide hose clamps on flexible fuel lines leading to fuel strainers for both main diesel engines and the generator.
Action required: 705 - Other - as specified
Due 22 February 2010
Resolved 24 February 2010
Resolution: Operator provided photo with evidence of installing hose clamps to the satisfaction of the attending marine inspector.
Documentation › Certificates/Documents › FCC SSL
Issued 26 February 2007 Resolved
Provide current FCC Station and FCC Safety License.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 29 March 2007
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 26 February 2007 Resolved
Conduct satisfactory drug/alcohol program audit with a USCG inspector.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 29 March 2007
Navigation › Piloting/Steering › US Coast Pilot
Issued 26 February 2007 Resolved
Provide updated Coast Pilot for area of operation.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 29 March 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 February 2007 Resolved
Provide current Aspirin for vessel first aid kit.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 29 March 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 February 2007 Resolved
Install corrosion resistant clip on waterlight lanyard for ring lifebuoy.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 29 March 2007
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 26 February 2007 Resolved
Prove proper operation of bilge high level alarm light in way of forward bilge.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 29 March 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 February 2007 Resolved
Provide cover for forward port engine room battery bank.
Action required: 705 - Other - as specified
Due 26 March 2007
Resolved 29 March 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 February 2007 Resolved
Install retro reflective tape on both sides of ring lifebuoy.
Action required: 705 - Other - as specified
Due 26 February 2007
Resolved 26 February 2007
Resolution: Retro reflective tape was installed on the back of the ring lifebuoy.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 23 January 2006 Resolved
Provide proof of current operator's license prior to taking passengers for hire.
Due 13 February 2006
Resolved 23 January 2006
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 January 2006 Resolved
Provide proof of enrollment in an approved drug and alcohol program prior to taking passengers for hire.
Due 13 February 2006
Resolved 13 February 2006
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 January 2006 Resolved
Provide separate stowage for all child PFD's and properly label stowage area.
Due 13 February 2006
Resolved 23 January 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 January 2006 Resolved
Properly secure or connect electrical wires for the fresh water holding tank supply gauge.
Due 13 February 2006
Resolved 26 February 2007
Engineering › Bilge Water Management System › Piping
Issued 23 January 2006 Resolved
Eliminate chafing of the electric bilge pump PVC piping and the port stabilizer hydraulic hose caused by the steering gear in way of the lazarette.
Due 13 February 2006
Resolved 26 February 2007
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 23 January 2006 Resolved
Stencil vessel name on 01 adult lifejacket.
Due 13 February 2006
Resolved 23 January 2006
Navigation › Piloting/Steering › US Coast Pilot
Issued 21 March 2005 Resolved
Provide updated copy of coast pilot and light list.
Action required: 705 - Other - as specified
Due 21 April 2005
Resolved 17 May 2005
Resolution: New 2005 Coast Pilot, applicable sections of the Light List downloaded from the internet.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 21 March 2005 Resolved
Renew retroreflective tape on all lifejackets.
Action required: 705 - Other - as specified
Due 21 April 2005
Resolved 17 May 2005
Construction/Loadline › Structures › Manhole
Issued 21 March 2005 Resolved
Properly label emergency escape route from bar area internally & externally, "EMERGENCY EXIT. KEEP CLEAR." iaw 46CFR185.30-15 (Old T)
Action required: 705 - Other - as specified
Due 21 April 2005
Resolved 17 May 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 21 March 2005 Resolved
Renew battery in waterlight attached to the 12 person buoyant apparatus.
Action required: 705 - Other - as specified
Due 21 April 2005
Resolved 17 May 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 March 2005 Resolved
Provide retroreflective tape on white ring lifebuoy.
Action required: 705 - Other - as specified
Due 21 April 2005
Resolved 17 May 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 March 2005 Resolved
Make new bilge alarm installation available for inspection. (Lazarette and forward crew berth)
Action required: 705 - Other - as specified
Due 21 April 2005
Resolved 17 May 2005
Personnel › Training
Issued 22 April 2004 Resolved
Provide proof of current First Aid & CPR Certification for crew. LEGACY COMPONENT DESC: First Aid/CPR
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 10 May 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 22 April 2004 Resolved
Replace expired contents of First Aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 4 May 2004
Documentation › Logs/Records
Issued 22 April 2004 Resolved
Provide logs for Crew Training, Drills, Life Saving equipment inspection and EPIRB testing. 46 CFR 185.520, 524, 722, 728. LEGACY COMPONENT DESC: Logbook (official)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 23 April 2004
Lifesaving › Buoyant Apparatus
Issued 22 April 2004 Resolved
Renew batteries for float lights on the Buoyant Apparatus and Life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 23 April 2004
Lifesaving
Issued 22 April 2004 Resolved
Stow paddles for life float with it.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 27 April 2004
Electrical › Electric Supply System (service) › Cable
Issued 22 April 2004 Resolved
Renew vessel's shore tie cable plug on vessels end.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 21 May 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 April 2004 Resolved
Provide plans for the installation of audible and visual flooding alarm indicators for lazarette and Fwd crew berth bilges IAW 46 CFR 182.530. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 19 June 2004
Resolved 21 March 2005
Operations/Management › Pollution › Retention of Oily Mixture
Issued 22 April 2004 Resolved
Clean oil and debris from all bilges consisting of lazarette, engine room and crew berth.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 21 May 2004
Engineering › Fuel Oil Service System
Issued 22 April 2004 Resolved
Install flame shield assembly on ship service generator Racor F/O water seperator filter. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 28 May 2004
Engineering › Sea-water System (primary cooling)
Issued 22 April 2004 Resolved
Install hose clamp on Port MDE raw water line inbrd side.
Action required: 705 - Other - as specified
Due 22 April 2004
Resolved 22 April 2004
Engineering › Fuel Oil Service System › Filter
Issued 22 April 2004 Resolved
Clean debris from inside of Port and Stbd MDE Racor F/O water seperator filters.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 28 May 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 22 April 2004 Resolved
Obtain Annual service for the engine room fixed CO2 system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 22 April 2004
Communications › Alarms/Indicators
Issued 22 April 2004 Resolved
Label bilge pump indicator lights and engine room high water alarm. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 13 June 2004
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 22 April 2004 Resolved
Provide proof of crew enrollment in drug testing program, random testing and EAP.
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 26 April 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 22 April 2004 Resolved
Renew oil dipstick in the port MDE.
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 27 April 2004
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 April 2004 Resolved
Label PFD stowage area for the child PFD's.
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 27 April 2004
Lifesaving › Lifebuoys
Issued 19 April 2004 Resolved
Renew Ring buoy Float light, Lanyard assembly, Tending line and stencil vsl's name. Vessel restricted to day light operations until corrected. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 13 June 2004
Construction/Loadline › Penetrations
Issued 31 March 2004 Resolved
Install positive stop valve on air conditioning drain overboard line located starboard side of engine room, amidships, that penetrates hull less than 6 inches above deepest load waterline in accordance with 46 CFR 179.350 (a). LEGACY COMPONENT DESC: overboard discharge
Action required: 705 - Other - as specified
Due 15 April 2004
Resolved 8 April 2004
Stability › Watertight Integrity
Issued 31 March 2004 Resolved
Make water tight in accordance with 46 CFR 179.310 (a) (2) the collision bulkhead. LEGACY COMPONENT DESC: Collision bulkhead
Action required: 705 - Other - as specified
Due 15 April 2004
Resolved 8 April 2004
Engineering › Bilge Water Management System
Issued 31 March 2004 Resolved
Properly cap both ends of pipe that connects the forward void with the lazzerette. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 15 April 2004
Resolved 8 April 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 18 February 2003 Resolved
Provide 2 adult type I USCG approved lifejackets in order that total lifejackets on board is 36.
Due 4 March 2003
Resolved 3 March 2003
Resolution: Lifejackets provided.
Lifesaving › Lifejacket/PFD (Type I)
Issued 18 February 2003 Resolved
Renew retroreflective material on 24 identified adult lifejackets. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 4 March 2003
Resolved 3 March 2003
Resolution: Retro tape renewed.
Lifesaving › Lifebuoys
Issued 18 February 2003 Resolved
Mark orange lifebuoy with the vessel's name "Journey". LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Improper/Lack of Maintenance
Due 4 March 2003
Resolved 28 February 2003
Resolution: Lifebouy marked w/vsl name.
Lifesaving › Liferaft Equipment
Issued 18 February 2003 Resolved
Provide 2 oars (4' long w/name of vessel) for the 6 person lifefloat. LEGACY COMPONENT DESC: Paddle
Condition: Unknown
Due 4 March 2003
Resolved 28 February 2003
Resolution: Oars provided and marked properly.
Communications › Radio Communications
Issued 18 February 2003 Resolved
Provide new battery and hydrostatic release for EPIRB. LEGACY COMPONENT DESC: EPIRB
Due 4 March 2003
Resolved 5 March 2003
Resolution: New battery and hydrostat release provided.
Navigation › Piloting/Steering
Issued 18 February 2003 Resolved
Provide corrected charts of navigated areas. LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 4 May 2004
Navigation › Piloting/Steering
Issued 18 February 2003 Resolved
Provide current navigation publications: U.S. Coast Pilot and Coast guard Light List. LEGACY COMPONENT DESC: US Coast Pilot
Condition: Unknown
Due 4 March 2003
Resolved 26 February 2003
Resolution: Pubs provided.
Documentation › Certificates/Documents
Issued 18 February 2003 Resolved
Provide proof of FCC Marine Radio Operator's permit.
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 19 April 2004
Documentation › Logs/Records
Issued 18 February 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 4 March 2003
Resolved 6 March 2003
Resolution: Evidence provided.
Operations/Management › Drills/Instruction
Issued 18 February 2003 Resolved
Provide and post an emergency instruction list IAW46CFR185.510.
Due 4 March 2003
Resolved 4 March 2003
Resolution: Instructions posted.
Pollution Prevention/Response
Issued 18 February 2003 Resolved
Remove oily water from underneath the portside Main Diesel Engine.
Due 4 March 2003
Resolved 3 March 2003
Resolution: Oily water removed.
Lifesaving › Hand Flares › Marking
Issued 18 February 2003 Resolved
Mark the hand flares storage box with the words "distress signals".
Due 18 February 2003
Resolved 18 February 2003
Resolution: Marked properly.
Operations/Management › Drills/Instruction
Issued 18 February 2003 Resolved
Mark both emergency exits with the words "Emergency Exit, Keep Clear".
Due 18 February 2003
Resolved 18 February 2003
Resolution: Marked Properly.
Lifesaving › Lifejacket/PFD (Type III)
Issued 11 February 2002 Resolved
MARK ALL LIFE VEST'S WITH VSL NAME IN LIEU OF M/V "ADMIRAL" LEGACY COMPONENT DESC: Marking
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2002
Resolution: ALL LIFE VEST''S MARKED WITH VESSEL NAME "JOURNEY".
Lifesaving › Buoyant Apparatus
Issued 11 February 2002 Resolved
ATTACH 6 MAN BUOYANT APPARATIS TO 12 MAN LIFE FLOAT WITH PAINTER IAW 46 CFR 180.137.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2002
Resolution: BUOYANT APPARATUS CONNECTED TO LIFE FLOAT WITH PAINTER.
Engineering › Fuel Oil Service System
Issued 11 February 2002 Resolved
MAKE FLEXIBLE FUEL LINES SUITABLE FOR USE. 46 CFR 182.15-40. LEGACY COMPONENT DESC: Hose
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2002
Resolution: FLEXIBLE FUEL LINES MADE SUITABLE FOR USE.
Construction/Loadline
Issued 8 February 2001 Resolved
PROVIDE VISUAL ALARM FOR BILGE HIGH LEVEL ALARM SYSTEM.
Condition: Unknown
Due 8 March 2001
Resolved 5 March 2001
Construction/Loadline
Issued 8 February 2001 Resolved
PROPERLY SECURE AFT DECK HATCH TO VESSEL.
Condition: Unknown
Due 8 March 2001
Resolved 5 March 2001
Construction/Loadline
Issued 8 February 2001 Resolved
PROVIDE PROPERLY LATCHED DECK HATCH FOR AFTER DECK HATCH.
Condition: Unknown
Due 8 March 2001
Resolved 5 March 2001
Construction/Loadline
Issued 19 July 2000 Resolved
INSTALL HIGH WATER LEVEL ALARMS IN E/R.
Condition: Unknown
Due 28 September 2000
Resolved 2 October 2000
Lifesaving
Issued 19 July 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 September 2000
Resolved 2 October 2000
Fire Fighting
Issued 19 July 2000 Resolved
SERVICE FIXED FIREFIGHTING EXTGUISHER IN E/R.
Condition: Unknown
Due 28 September 2000
Resolved 2 October 2000
Engineering
Issued 10 May 2000 Resolved
Make repairs to the port engine exhaust outlet.
Condition: Unknown
Due 10 June 2000
Resolved 26 June 2000
Documentation
Issued 10 May 2000 Resolved
Prior to carrying passengers for hire provide onboard a valid certificate of documentation.
Condition: Unknown
Due 10 May 2000
Resolved 10 May 2000
Accommodation/Occupational Safety
Issued 10 May 2000 Resolved
Renew as original the starboard engine room exhaust vent ducting.
Condition: Unknown
Due 10 June 2000
Resolved 26 June 2000
Documentation
Issued 10 May 2000 Resolved
Prior to carrying passengers for hire conduct a re-inspection.
Condition: Unknown
Due 10 May 2000
Resolved 10 May 2000
Construction/Loadline
Issued 20 April 2000 Resolved
NO MORE THAN SIX PASSENGERS FOR HIRE MAY BE CARRIED UNTIL A SATISFACTORY CREDIT DRYDOCK IS CONDUCTED BY AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 20 April 2000
Resolved 20 April 2000
Construction/Loadline
Issued 12 April 1999 Resolved
Prove operation of fixed bilge system.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Lifesaving
Issued 12 April 1999 Resolved
Provide on board 6 red hand flares.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Construction/Loadline
Issued 12 April 1999 Resolved
Label valves on bilge manifold.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Lifesaving
Issued 12 April 1999 Resolved
Conduct man overboard drill.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Fire Fighting
Issued 12 April 1999 Resolved
Service fixed & portable fire extinguishers.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Lifesaving
Issued 12 April 1999 Resolved
Prove operation of buoyant apparatus' waterlight.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Lifesaving
Issued 16 April 1997 Resolved
PROVIDE 406 MHZ EPIRB AS REQUIRED FOR LIMITED COASTWISE ROUTE IN ACCORDANCEWITH 46 CFR 180.64. UNTIL THIS REQUIREMENT IS MET TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR, THE VESSEL SHALL BE RESTRICTED TO A LAKES, BAYS AND SOUNDS ROUTE OF SAN FRANCISCO BAY AND ITS TRIBUTARIES.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Lifesaving
Issued 16 April 1997 Resolved
PROVIDE OPERATIVE WATERLIGHT FOR BUOYANT APPARATUS. UNTIL THIS REQUIREMENT IS MET TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR, THE VESSEL ISRESTRICTED TO OPERATION DURING DAYLIGHT HOURS WHEN CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Engineering
Issued 14 March 1996 Resolved
RENEW OR REPACK SHAFT GLAND SEALS ON TAIL SHAFTS SO AS TO REDUCE THE AMOUNTOF COOLING WATER TO A DROP ABOUT EVERY MINUTE WHILE AT A MOORING DOCK.
Condition: Unknown
Due 14 March 1996
Resolved 14 March 1996
Accommodation/Occupational Safety
Issued 13 March 1996 Resolved
RENEW STARBOARD BROKEN WINDOW IN PASSENGER LOUNGE AMIDSHIPS.
Condition: Unknown
Due 13 March 1996
Resolved 13 March 1996
Fire Fighting
Issued 13 March 1996 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROVIDE TWO 2 1/2 GALLON BUCKETS WITH LINE AND MARKED "FIRE BUCKET".
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Lifesaving
Issued 13 March 1996 Resolved
POST AN EMERGENCY BROADCAST RADIO INSTRUCTION PLACARD NEAR THE VHF RADIO.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Documentation
Issued 13 March 1996 Resolved
PROVIDE THE NAME OF THE MEDICAL REVIEW OFFICER FOR DRUG TESTING PROGRAM.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Accommodation/Occupational Safety
Issued 13 March 1996 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROVIDE A WIRE LOCK FOR TYPE III MARINE SANITATION DEVICE OVERBOARD VALVE.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Accommodation/Occupational Safety
Issued 13 March 1996 Resolved
PROVIDE A SIGN FOR AFT LAZ AREA NEAR THE OVERBOARD VALVE FOR THE TYPE III MARINE SANITATION DEVICE, WHICH STATES VALVE IS TO BE CLOSED WHEN WITHIN 3 MILES OF SHORE.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Lifesaving
Issued 13 March 1996 Resolved
PLACE RETROREFLECTIVE TAPE ON LIFE RING BUOY.
Condition: Unknown
Due 9 April 1996
Resolved 9 April 1996
Engineering
Issued 13 March 1996 Resolved
RENEW PORT EXHAUST VENT.
Condition: Unknown
Due 13 March 1996
Resolved 13 March 1996
Construction/Loadline
Issued 17 February 1995 Resolved
Properly mark the vessel's stern with name and home port.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Lifesaving
Issued 17 February 1995 Resolved
Prior to the carriage of passengers for hire, Provide the proper amount of distress signals for the vessel.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Documentation
Issued 28 April 1994 Resolved
PROVIDE PROOF THAT THE RANDOM PART OF THE DRUG TESTING PROGRAM IS IN FORCE,REWRITE THE PROGRAM DOCUMENT TO STATE SPECIFICALLY WHO THE RANDOM TESTING WILL OCCUR THRU THE YEAR.
Condition: Unknown
Due 28 May 1994
Resolved 9 June 1994
Navigation
Issued 28 April 1994 Resolved
REPAIR STEERING POST BRACKETS ON BOTH PORT AND STBD RUDDERS, THE BOLTS THATHOLD THE PLATES THE THEIR MOUNTS ARE ALLOWING SOME MOVEMENT. ONCE REPAIREDCONDUCT AN UNDERWAY TEST WITH A COAST GUARD MARINE INSPECTOR TO WITNESS.
Condition: Unknown
Due 15 June 1994
Resolved 9 June 1994
Fire Fighting
Issued 28 April 1994 Resolved
PROVIDE 1 B-II FIRE EXTINGUISHER, THE VESSEL IS RESTRICTED FROM CARRYING PASSENGERS UNTIL COMPLETED.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Documentation
Issued 28 April 1994 Resolved
PROVIDE A COPY OF THE FCC CERTIFICATE WHICH EXPIRED 28 JUL 93
Condition: Unknown
Due 28 May 1994
Resolved 9 June 1994
Fire Fighting
Issued 18 May 1993 Resolved
PROVE FIXED CO2 SYS (CYLINDER) IS INSTALLED PROPERLY IAW 46CFR181.20 AND MFG INSTRUCTIONS. DISCHARGE HEAD ON CO2 CYLINDER HAS MFG LABEL REQUIRING LABLE TO BE FACING UP. FAX FM MFG REP INDICATES THIS SYS HAS A BENT SYPHON TUBE AND CYLINDER VALVE BODY MUST FACE UP FOR PROPER OPERATION OF SYS.
Condition: Unknown
Due 11 June 1993
Resolved 11 June 1993
Fire Fighting
Issued 18 May 1993 Resolved
PROVIDE A 2" LENGTH OF PIPE WITH CAP AT DEAD END OF CO2 PIPING AS PER 46 CFR 181.20-20(d)
Condition: Unknown
Due 11 June 1993
Resolved 11 June 1993
Engineering
Issued 18 May 1993 Resolved
PROVIDE FLAME SHIELD/DRIP BOWLS UNDER RAYCOR FUEL OIL FILTERS.
Condition: Unknown
Due 11 June 1993
Resolved 11 June 1993
Documentation
Issued 15 March 1993 Resolved
PROVIDE COPY OF WRITTEN OUTLINE OF DRUG TESTING PROGRAM AND DOCUMENTATION OF RANDOM TESTING. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 March 1993
Resolved 15 March 1993
Fire Fighting
Issued 15 March 1993 Resolved
HAVE 15 LB CO2 FIRE EXTINGUISHER SERVICED OR MAKE ARRANGEMENTS TO HAVE IT WEIGHED BY A USCG INSPECTOR.
Condition: Unknown
Due 15 March 1993
Resolved 15 March 1993
Lifesaving
Issued 15 March 1993 Resolved
MAKE REPAIRS TO FOUR (4) LIFE PRESERVERS, 2 NEEDING REFLECTIVE TAPE AND 2 NEEDING TO BE PATCHED.
Condition: Unknown
Due 15 March 1993
Resolved 15 March 1993
Accommodation/Occupational Safety
Issued 15 March 1993 Resolved
CLOSE SEWAGE TANK DISCHARGE VALVE NEAR SKIN OF SHIP.
Condition: Unknown
Due 15 March 1993
Resolved 15 March 1993
Fire Fighting
Issued 15 March 1993 Resolved
PROVIDE PROOF THAT INSTALLATION OF E/R CO2 SYSTEM IS IN ACCORDANCE WITH 46 CFR 181.20, INCLUDING CORRECT SIZE OF CO2 CYLINDER. HAVE SYSTEM SERVICED.
Condition: Unknown
Due 15 March 1993
Resolved 15 March 1993
Fire Fighting
Issued 15 March 1993 Resolved
PROVIDE ADEQUATE SUCTION HOSE FOR HAND FIRE PUMP._x001C_
Condition: Unknown
Due 15 March 1993
Resolved 15 March 1993
Lifesaving
Issued 15 March 1993 Resolved
PROVIDE SIGN INDICATING NUMBER AND TYPE OF LIFE PRESERVERS UNDER OPERATOR'SSEAT._x001C_
Condition: Unknown
Due 15 March 1993
Resolved 15 March 1993
Accommodation/Occupational Safety
Issued 15 March 1993 Resolved
TIGHTEN LOOSE RAILING, PORT SIDE. _x001C_
Condition: Unknown
Due 15 March 1993
Resolved 15 March 1993
Lifesaving
Issued 15 March 1993 Resolved
HAVE THE 16-PERSON B/A INSPECTED BY A MANUFACTURER'S REP. TO DETERMINE CONTINUED FITNESS FOR SERVICE. B/A HAS LOOSE MATERIAL INSIDE. UNTIL THIS ITEM CORRECTED, VESSEL IS RESTRICTED TO LAKES, BAYS, AND SOUNDS: SAN FRANCISCO BAY AND TRIBUTARIES, NOT MORE THAN 1 MILE FROM SHORE.
Condition: Unknown
Due 15 March 1993
Resolved 15 March 1993
Lifesaving
Issued 15 March 1993 Resolved
REPAIR HOLE IN B/A, IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. UNTIL THIS ITEM IS CORRECTED, THE VESSEL IS RESTRICTED TO LAKES, BAYS, AND SOUNDS: SAN FRANCISCO BAY AND TRIBUTARIES, NOT MORE THAN 1 MILE FROM SHORE.
Condition: Unknown
Due 15 March 1993
Resolved 15 March 1993
Lifesaving
Issued 15 March 1993 Resolved
REPLACE LIFELINE ON BUOYANT APPARATUS. UNTIL THIS ITEM IS CORRECTED, THE VESSEL IS RESTRICTED TO LAKES, BAYS, AND SOUNDS: SAN FRANCISCO BAY AND TRIBUTARIES, NOT MORE THAN 1 MILE FROM SHORE.
Condition: Unknown
Due 15 March 1993
Resolved 15 March 1993
Lifesaving
Issued 15 March 1993 Resolved
REPAIR WATERLIGHT ON B/A. UNTIL THIS ITEM IS CORRECTED, THE VESSEL IS RESTRICTED TO LAKES, BAYS, AND SOUNDS: SAN FRANCISCO BAY AND TRIBUTARIES, NOT MORE THAN 1 MILE FROM SHORE.
Condition: Unknown
Due 15 March 1993
Resolved 15 March 1993
Engineering
Issued 15 March 1993 Resolved
REPAIR COVER BRACKET FOR ALTERNATOR ON STBD MAIN ENGINE.
Condition: Unknown
Due 15 March 1993
Resolved 15 March 1993
Electrical
Issued 15 March 1993 Resolved
REINSTALL COVER ON A/C UNIT ELECTRICAL PANEL.
Condition: Unknown
Due 15 March 1993
Resolved 15 March 1993
Electrical
Issued 15 March 1993 Resolved
MAKE PROPER ELECTRICAL CONNECTIONS FOR GAUGE WIRES ON POTABLE WATER SYSTEM.WIRES ARE CURRENTLY TWISTED TOGETHER._x001C_
Condition: Unknown
Due 15 March 1993
Resolved 15 March 1993
Accommodation/Occupational Safety
Issued 15 March 1993 Resolved
STENCIL "EMERGENCY EXIT, DO NOT BLOCK" ON FWD ESCAPE HATCH (OUTSIDE).
Condition: Unknown
Due 15 March 1993
Resolved 15 March 1993
Fire Fighting
Issued 4 March 1991 Resolved
INSTALL A REMOTE PULL FOR THE HALON SYSTEM AND ENGINE AND VENTILATION SHUTDOWN INTERLOCK.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Fire Fighting
Issued 4 March 1991 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS AS THEY ARE OVERDUE. SERVICE ENGINE ROOM FIXED HALON SYSTEM.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Fire Fighting
Issued 4 March 1991 Resolved
PROVIDE HAND FIRE PUMP.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Engineering
Issued 4 March 1991 Resolved
REPLACE 30X30 MESH IN FUEL TANK VENT FLAME SCREENS.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Accommodation/Occupational Safety
Issued 4 March 1991 Resolved
REPLACE BROKEN PILOTHOUSE WINDOWS.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Navigation
Issued 4 March 1991 Resolved
DRILL AND PIN STEERING GEAR YOKE.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Navigation
Issued 4 March 1991 Resolved
PROVIDE COMPASS DEVIATION CARD.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Engineering
Issued 4 March 1991 Resolved
LABEL REMOTE FUEL SHUT OFFS.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Lifesaving
Issued 4 March 1991 Resolved
PROVIDE RETRO-REFLECTIVE TAPE ON BOUYANT APPARATUS.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Lifesaving
Issued 4 March 1991 Resolved
PROVIDE A FLOAT FREE LINK FOR BOUYANT APPARATUS.
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Construction/Loadline
Issued 4 March 1991 Resolved
REMOVE SEATING FROM OVER AFT CABIN ESCAPE HATCH AND LABEL "ESCAPE, DO NOT BLOCK." IN AFT CABIN LABEL "EMERGENCY ESCAPE INSIDE."
Condition: Unknown
Due 4 March 1991
Resolved 4 March 1991
Lifesaving
Issued 5 March 1990 Resolved
REMARK 5 ADULT PFD'S WITH VESSEL'S NAME.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Lifesaving
Issued 5 March 1990 Resolved
PROCURE REPLACEMENT WATERTIGHT CONTAINER FOR DISTRESS FLARES, MARK WITH VESSEL NAME.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Engineering
Issued 5 March 1990 Resolved
REPLACE BILGE VALVE PAPER TAGS WITH METAL TAGS.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Documentation
Issued 5 March 1990 Resolved
POST ALL DOCUMENT UNDER GLASS.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Lifesaving
Issued 6 March 1989 Resolved
REMARK BUOYANT APPARATUS WITH VESSEL NAME.
Condition: Unknown
Due 6 March 1989
Resolved 6 March 1989
Lifesaving
Issued 6 March 1989 Resolved
REMARK ALL PFD (LIFE JACKETS) WITH VESSEL NAME.
Condition: Unknown
Due 6 March 1989
Resolved 6 March 1989
Construction/Loadline
Issued 27 April 1988 Resolved
RENEW GASKET ON LAZARETTE HATCH.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Engineering
Issued 27 April 1988 Resolved
REMOVE EXCESS OIL FROM BILGE AND PROVE OPERATION OF BILGE PUMPS.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Documentation
Issued 27 April 1988 Resolved
PROVIDE CURRENT FCC RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 27 April 1988
Resolved 27 April 1988
Documentation
Issued 20 April 1987 Resolved
PROVIDE CURRENT VESSEL DOCUMENT.
Condition: Unknown
Due 20 April 1987
Resolved 20 April 1987
Documentation
Issued 20 April 1987 Resolved
PROVIDE CURRENT FCC SAFETY PADIOTELPHONY CERTIFICATE.
Condition: Unknown
Due 20 April 1987
Resolved 20 April 1987
Engineering
Issued 20 April 1987 Resolved
REMOVE EXCESSIVE OIL/WATER FROM BILGE.
Condition: Unknown
Due 20 April 1987
Resolved 20 April 1987
Lifesaving
Issued 26 April 1986 Resolved
PROVIDE USCG APPROVED WATERLITE FOR B/A & L/RING.
Condition: Unknown
Due 26 April 1986
Resolved 26 April 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.