Records from 1985 to 2021. Most recent: inspection, 27 August 2021.
Inspection history · 65
27 August 2021
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7298503
12 December 2020
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7110817
8 December 2020
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7108612
18 December 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6872239
28 September 2019
Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6823297
6 November 2018
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6567303
6 November 2018
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6577522
11 December 2017
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6323759
5 October 2017
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6270524
7 December 2016
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6051718
16 November 2016
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6042642
7 December 2015
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5777126
23 November 2015
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5768876
1 June 2014
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4877738
22 July 2011
Inclining Experiment
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4117154
27 August 2008
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3309545
4 August 2008
Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 3289886
17 July 2007
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2998492
28 August 2006
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2762527
27 July 2006
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2726443
17 October 2005
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2516463
21 September 2005
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2491789
21 July 2004
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2140637
20 July 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2139567
8 March 2004
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2020531
11 June 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1810294
29 July 2002
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1652106
25 July 2002
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1648944
23 July 2001
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1395785
27 July 2000
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1373119
28 June 2000
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1417092
23 July 1999
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1426257
31 August 1998
Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1390815
28 August 1997
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1119846
18 August 1997
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1386079
7 August 1996
Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1355914
29 December 1995
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 876371
20 September 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1184891
6 June 1995
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1382993
14 April 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 228717
18 September 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 860579
12 July 1994
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1176261
14 June 1994
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1174262
10 June 1994
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1359828
16 June 1993
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1359589
31 March 1993
Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1150701
6 July 1992
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 960355
16 June 1992
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 944928
20 June 1991
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1209845
30 January 1991
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1301847
25 June 1990
COI Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 931104
12 April 1990
Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 919699
20 September 1989
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1199805
11 September 1989
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1213717
2 August 1989
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1204925
30 June 1989
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 899207
9 June 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1207274
27 July 1988
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1339892
8 July 1988
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 897987
15 January 1988
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1324306
8 July 1987
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1015939
31 December 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1312218
8 July 1986
Credit Drydock · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 998504
1 August 1985
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 982127
15 February 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1285804
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 December 2020
No resolution recorded
Vessel is required to complete a hull exam every 2 yerars.
Vessel is overdue for hull exam.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 18 December 2019
Resolved
Replace E/R hatch gasket.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2020
Resolution: Gasket replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 December 2019
Resolved
Properly run wires portside accom. space.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2020
Resolution: Wires ran properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 December 2019
Resolved
Replace retro tape on all 3 life rings.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2020
Resolution: Tape replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 December 2019
Resolved
Repair/replace frequency meter switch.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2020
Resolution: Switch replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 September 2019
Resolved
Demonstrate proper operation of navigation lights.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 September 2019
Resolved 3 October 2019
Resolution: Nav lights are working properly.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 5 October 2017
Resolved
Replace grab lines on port and stbd life rings.
Action required: 705 - Other - as specified
Due 5 November 2017
Resolved 24 October 2017
Resolution: New grab lines installed.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 5 October 2017
Resolved
Update log book entries for safety drills and EPIRB tests.
Action required: 705 - Other - as specified
Due 5 November 2017
Resolved 5 October 2017
Resolution: Corrected on the spot
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 7 December 2016
Resolved
Provide alcohol testing devices
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 January 2017
Resolved 13 December 2016
Documentation › Markings/Placards › Warning Signs
Issued 7 December 2016
Resolved
Label 120V electrical panels in E/R and galley.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 December 2016
Resolved 7 December 2016
Communications › Alarms/Indicators › High Water Alarm
Issued 7 December 2016
Resolved
Prove proper operation of bilge high water alarms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2016
Resolved 7 December 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 December 2016
Resolved
Prove proper operation of stern light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2016
Resolved 7 December 2016
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2016
Resolved
Laz: Remove Splash Zone from aft port corner and make area available for inspection/repair as necessary.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2016
Resolved 28 November 2016
Resolution: Splash zone removed and cracked weld gouged and rewelded.
Construction/Loadline › Hull › Longitudinal Frame
Issued 16 November 2016
Resolved
Laz: Re-weld longitudinal frame at transom.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 November 2016
Resolved 28 November 2016
Resolution: Frame rewelded.
Construction/Loadline › Hull › Weld
Issued 16 November 2016
Resolved
Laz: Re-weld longitudinal stringer on port side aft (broken/sloppy weld).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 November 2016
Resolved 28 November 2016
Resolution: Stringer rewelded.
Construction/Loadline › Hull › Hull Plating
Issued 16 November 2016
Resolved
Laz: Remove unknown material fused to hull port side aft, and make available for inspection/repair as necessary.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2016
Resolved 28 November 2016
Resolution: Bolt removed from limber hole, no repair needed.
Construction/Loadline › Hull › Bottom Plating
Issued 16 November 2016
Resolved
E/R: Remove Splash Zone from port fwd chine and make available for inspection/repair as necessary.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 November 2016
Resolved 28 November 2016
Resolution: Splash zone removed, area inspected; no repair needed.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 November 2016
Resolved
E/R: Clean and repair weeping fuel piping and clean base of integral fuel tank wall to allow inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2016
Resolved 28 November 2016
Resolution: Base cleaned for inspection, all sat; weeping fuel line repaired.
Engineering › Steering Gear System › Hydraulic Hose
Issued 16 November 2016
Resolved
E/R: Repair leaking hydraulic fluid lines associated with hydraulic tank on aft b/h
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2016
Resolved 28 November 2016
Resolution: Hydraulic leak repaired.
Engineering › Bilge Water Management System › Valve
Issued 16 November 2016
Resolved
Replace wasted forepeak bilge valve handle at reach rod.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2016
Resolved 28 November 2016
Resolution: New valve and handle installed at reach rod.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 16 November 2016
Resolved
Install wire or chain retention device on forepeak hatch
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2016
Resolved 28 November 2016
Resolution: Chain installed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 30 November 2015
Resolved
Re-stencil starboard life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2015
Resolved 21 January 2016
Engineering › Bilge Water Management System › Piping
Issued 30 November 2015
Resolved
Repair forepeak bilge suction pipe.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 December 2015
Resolved 21 January 2016
Engineering › Bilge Water Management System › Valve
Issued 30 November 2015
Resolved
Install foot valve or check valve in bilge piping system to prevent back-flooding of forepeak.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 December 2015
Resolved 21 January 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 November 2015
Resolved
Repair or replace water light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2015
Resolved 21 January 2016
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 August 2008
Resolved
Install blank cover on aft electrical distribution panel where missing breaker.
Action required: 705 - Other - as specified
Due 27 September 2008
Resolved 26 September 2008
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 27 August 2008
Resolved
Repair window aft pilot house.
Action required: 705 - Other - as specified
Due 27 September 2008
Resolved 26 September 2008
Operations/Management › Equipment Service/Testing › EPIRB
Issued 27 August 2008
Resolved
Provide proof of EPIRB registration
Action required: 705 - Other - as specified
Due 27 September 2008
Resolved 26 September 2008
Construction/Loadline › Structures › Trunk
Issued 17 July 2007
Resolved
Remove Splash Zone from port rudder post tube for inspection/repair.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 24 August 2007
Electrical › Electrical Distribution System (service) › Switchboard
Issued 17 July 2007
Resolved
Cover openings on face of generator switchboard.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 16 August 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 July 2007
Resolved
Replace expired items in first aid kit.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 16 August 2007
Lifesaving › Lifefloat › Markings
Issued 17 July 2007
Resolved
Stencil lifesaving capacity on L/F
Action required: 705 - Other - as specified
Due 17 July 2007
Resolved 17 July 2007
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 17 July 2007
Resolved
Make air receivers available for inspection.
Action required: 705 - Other - as specified
Due 17 August 2007
Resolved 24 August 2007
Operations/Management › Pollution › Control of Discharge of Oil
Issued 28 August 2006
Resolved
Clean diesel fuel from galley bilge prior to getting underway.
Due 28 August 2006
Resolved 28 August 2006
Operations/Management › Pollution › Control of Discharge of Oil
Issued 28 August 2006
Resolved
Monitor galley bilge for possible fuel tank leak.
Action required: 705 - Other - as specified
Due 28 September 2006
Resolved 3 October 2006
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 28 August 2006
Resolved
Repair E/R-Laz door indicator light on bridge.
Action required: 705 - Other - as specified
Due 28 September 2006
Resolved 3 October 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 August 2006
Resolved
Repair bilge hi-water alarm (audible indicator).
Action required: 705 - Other - as specified
Due 28 September 2006
Resolved 3 October 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 28 August 2006
Resolved
Repair loose railing in pilot house.
Action required: 705 - Other - as specified
Due 28 September 2006
Resolved 3 October 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 August 2006
Resolved
Strengthen deck hatch in galley outside forward berthing.
Action required: 705 - Other - as specified
Due 28 September 2006
Resolved 3 October 2006
Engineering › Bilge Water Management System › Manifold
Issued 28 August 2006
Resolved
Label all valves on bilge manifold.
Action required: 705 - Other - as specified
Due 28 September 2006
Resolved 3 October 2006
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 4 October 2005
Resolved
Provide "list of passengers" procedures IAW 46 CFR 185.503.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Documentation › Logs/Records › Drug Test Records
Issued 4 October 2005
Resolved
Provide Drug & Alcohol program information IAW 46 CFR 16
Due 4 November 2005
Resolved 17 October 2005
Resolution: According to the DAPI, [name withheld], this company is in compliance.
Engineering › Freshwater Generation System › Piping
Issued 4 October 2005
Resolved
Double clamp hoses
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 4 October 2005
Resolved
Repair as original all M/E exhaust to overboard spool pieces.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Resolution: re welded
Construction/Loadline › Hull › Bracket
Issued 4 October 2005
Resolved
Repair as original the overhead bracket, where fractured, Port overhead at 4th frame from forward in way of side shell.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Resolution: Re-welded
Construction/Loadline › Hull › Bracket
Issued 4 October 2005
Resolved
Repair as original the bracket welds, where fractured, in way of transom starboard aft.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Resolution: Re-welded
Engineering › Bilge Water Management System › Pump
Issued 4 October 2005
Resolved
Repair bilge pump to fire main cross connection where leaking.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 4 October 2005
Resolved
Repair fuel filter starboard M/E where leaking.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Documentation › Markings/Placards › Oil Discharge Placard
Issued 4 October 2005
Resolved
Provide oil pollution placard IAW 33 CFR 155.450
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Accommodation/Occupational Safety › Ventilation › General
Issued 4 October 2005
Resolved
Repair vent to sewage tank, double clamp hoses and remove spilled (now dry) residue from bilge.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 October 2005
Resolved
Provide sea rails on cooking range IAW 46 CFR 184.220.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Engineering › Fuel Oil Service System › Hose
Issued 4 October 2005
Resolved
Repair as original both fuel tank fill hoses where deteriorated. Port side weeps fuel.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 4 October 2005
Resolution: Repaired as original both fuel tank fill hoses where deteriorated.
Engineering › Bilge Water Management System › Not Operational
Issued 4 October 2005
Resolved
Clean bilges free of fuel and oil.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Electrical › Electric Supply System (service) › Cable
Issued 4 October 2005
Resolved
Remove dead-end wires in engine room
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Accommodation/Occupational Safety › Potable Water System › General
Issued 4 October 2005
Resolved
Secure water heater.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Operations/Management › Drills/Instruction › Fire
Issued 21 September 2005
Resolved
Conduct Fire and Man-Overboard drills with regular crew.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Resolution: Witnessed Sat Drills
Communications › Radio Communications › EPIRB
Issued 21 September 2005
Resolved
Provide EPIRB. Vessel to stay within 3 miles from shore until working EPIRB reinstalled.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 17 October 2005
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 11 June 2003
Resolved
Place plug in fuel distribution box bleed valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2003
Resolved 12 June 2003
Resolution: Plug satisfactorily installed.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 11 June 2003
Resolved
Stop fuel leak in fuel return piping to fuel distribution box.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2003
Resolved 12 June 2003
Resolution: Fuel leak satisfactorily corrected.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 11 June 2003
Resolved
Stop fuel leak supply valve to racor filter center main engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2003
Resolved 12 June 2003
Resolution: Fuel leak satisfactorily corrected.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 11 June 2003
Resolved
Make fuel return piping in lazarette space leak free.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2003
Resolved 12 June 2003
Resolution: Fuel piping satisfactorily corrected.
Engineering › Fuel Oil Storage/Transfer System
Issued 11 June 2003
Resolved
Make lazarette bilge space free of fuel/oil and water.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2003
Resolved 12 June 2003
Resolution: Lazarette bilge space satisfactorily cleaned of all fuel and water.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 July 2002
Resolved
Wiring on the starbord side in forward crew bunk room was not suported with 24 inch metallic wire hangers.
Condition: Improper Installation
Due 25 July 2002
Resolved 25 July 2002
Resolution: Corrected on spot.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 25 July 2002
Resolved
Provide blank for missing switch on aft distribution panel in engine room.
Condition: Improper/Lack of Maintenance
Due 25 July 2002
Resolved 25 July 2002
Resolution: Corrected on spot.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 25 July 2002
Resolved
Replace non CG approved fire extinguisher with CG approved BII fire extinguisher.
Condition: Placed in Improper Service
Due 31 July 2002
Resolved 29 July 2002
Resolution: Replaced extinguisher.
Accommodation/Occupational Safety › Cooking Systems
Issued 25 July 2002
Resolved
Install storm rails on the inboard side of the galley stove .
Due 31 July 2002
Resolved 29 July 2002
Resolution: Installed storm rails.
Engineering › Bilge Water Management System
Issued 25 July 2002
Resolved
Remove flexible hose sections in the bilge system and ensure continous matallic piping in the following spaces (a) forward crew bunk in two diffrent locations (b) aft galley area. LEGACY COMPONENT DESC: Piping
Due 31 July 2002
Resolved 29 July 2002
Resolution: Installed metallic piping.
Construction/Loadline
Issued 23 July 2001
Resolved
MAKE BULKHEAD BETWEEN ENGINEROOM AND LAZARETTE WATERTIGHT.
Condition: Unknown
Due 3 August 2001
Resolved 3 August 2001
Electrical
Issued 23 July 2001
Resolved
PROVIDE PROPER LIGHT COVERS, SCREWS IN STATEROOM BUNKS.
Condition: Unknown
Due 3 August 2001
Resolved 3 August 2001
Lifesaving
Issued 23 July 2001
Resolved
INSTALL A PUBLIC ADDRESS SYSTEM ON VESSEL IAW 46 CFR 184.610.
Condition: Unknown
Due 3 August 2001
Resolved 3 August 2001
Fire Fighting
Issued 23 July 2001
Resolved
PROVE OPERATION OF FIRE PUMP AT 60 PSI IAW 46 CFR 181.300
Condition: Unknown
Due 3 August 2001
Resolved 3 August 2001
Construction/Loadline
Issued 23 July 2001
Resolved
PROVE PROPER OPERATION OF BILGE PUMP SYSTEM AND CROSSOVER WITH FIRE PUMP.
Condition: Unknown
Due 3 August 2001
Resolved 3 August 2001
Fire Fighting
Issued 23 July 2001
Resolved
PROPERLY MOUNT PORTABLE FIRE EXTINGUISHER IN GALLEY.
Condition: Unknown
Due 3 August 2001
Resolved 3 August 2001
Construction/Loadline
Issued 27 July 2000
Resolved
Gouge and repair fractured welds in the following areas: 5 in lazarette, 7 in engineroom. See MINS for details
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Engineering
Issued 27 July 2000
Resolved
REPLACE CUTLESS BEARING ON CENTER PROP.
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Construction/Loadline
Issued 27 July 2000
Resolved
Crop and renew aft 5 ft. of deep frame center starboard side from transom forward.
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Construction/Loadline
Issued 27 July 2000
Resolved
Crop and renew portside center engine frame forward of engine to lazarette bulkhead.
Condition: Unknown
Due 11 August 2000
Resolved 11 August 2000
Lifesaving
Issued 18 August 1997
Resolved
Replace grab lines to life floats as needed.
Condition: Unknown
Due 18 August 1997
Resolved 18 August 1997
Fire Fighting
Issued 18 August 1997
Resolved
Fire pump suction side find the leaks and fix.
Condition: Unknown
Due 18 August 1997
Resolved 18 August 1997
Lifesaving
Issued 18 August 1997
Resolved
Replace two of five water light battieries for for the life floats.
Condition: Unknown
Due 18 August 1997
Resolved 18 August 1997
Lifesaving
Issued 18 August 1997
Resolved
Replace one of three liferings, total needed is three.
Condition: Unknown
Due 18 August 1997
Resolved 18 August 1997
Lifesaving
Issued 16 June 1992
Resolved
CONDUCT UNDERWAY FIRE AND MAN OVERBOARD DRILLS IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Accommodation/Occupational Safety
Issued 20 June 1991
Resolved
PERFORM GENERAL HOUSEKEEPING THROUGHOUT VESSEL.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Construction/Loadline
Issued 20 June 1991
Resolved
MAKE REPAIRS TO FRACTURES AS MARKED IN FOREPEAK.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Construction/Loadline
Issued 20 June 1991
Resolved
MAKE REPAIRS TO CRACKED WELDS TO GENERATOR ELECTRICAL PANEL VERTICAL STANTIONS IN WAY OF THE OVERHEAD.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Documentation
Issued 20 June 1991
Resolved
PROVIDE A WASTE MANAGEMENT PLAN AND A MARPOL V PLACARD.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Engineering
Issued 20 June 1991
Resolved
DOUBLE CLAMP STARBOARD MAIN ENGINE MUFFLER.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Electrical
Issued 20 June 1991
Resolved
RENEW LIGHT COVER STARBOARD ENGINE ROOM AFT.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Navigation
Issued 20 June 1991
Resolved
RENEW BOLTS SECURING PORT AND STARBOARD RUDDER POST PACKING FLANGE.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Engineering
Issued 20 June 1991
Resolved
REMOVE OILY WATER FROM ENGINE ROOM BILGES.
Condition: Unknown
Due 20 June 1991
Resolved 20 June 1991
Deck/Cargo
Issued 25 June 1990
Resolved
CONNECT REACH ROD TO BILGE SUCTION VALVE IN FOREPEAK.
Condition: Unknown
Due 25 June 1990
Resolved 25 June 1990
Accommodation/Occupational Safety
Issued 25 June 1990
Resolved
PROPERLY REPAIR RAIL ON UPPER DECK, PORT SIDE, AFT OF WHEELHOUSE.
Condition: Unknown
Due 25 June 1990
Resolved 25 June 1990
Construction/Loadline
Issued 25 June 1990
Resolved
PROPERLY REPAIR FRACTURES IN FOREPEAK WHERE MARKED.
Condition: Unknown
Due 25 June 1990
Resolved 25 June 1990
Construction/Loadline
Issued 25 June 1990
Resolved
MAKE ENGINE ROOM WATERTIGHT DOOR WATERTIGHT AND PROVE PROPER OPERATION OF "DOOR OPEN" ALARM LIGHT IN WHEELHOUSE.
Condition: Unknown
Due 25 June 1990
Resolved 25 June 1990
Fire Fighting
Issued 25 June 1990
Resolved
PROVIDE 2 ADDITIONAL PORTABLE FIRE EXTINGUISHERS FOR A TOTAL OF 8 B-II'S.
Condition: Unknown
Due 25 June 1990
Resolved 25 June 1990
Construction/Loadline
Issued 25 June 1990
Resolved
PROPERLY REPAIR FRACTURES UNDER CREW CABIN, PORT SIDE, WHERE MARKED.
Condition: Unknown
Due 25 June 1990
Resolved 25 June 1990
Construction/Loadline
Issued 25 June 1990
Resolved
CROP AND RENEW DECK PLATING OVER MAIN ENGINE MUFFLERS IN WAY OF LAZARETTE.
Condition: Unknown
Due 25 June 1990
Resolved 25 June 1990
Lifesaving
Issued 25 June 1990
Resolved
PROVIDE 2 ADDITIONAL RING BUOYS FOR A TOTAL OF 3.
Condition: Unknown
Due 25 June 1990
Resolved 25 June 1990
Construction/Loadline
Issued 12 April 1990
Resolved
REPAIR ABOUT 8 INCH FRACTURE FORWARD OF STBD RUDDER POST BY ULTRASONICALLY CHASING ENDS OF FRACTURE, DRILL STOP, VEE AND WELD UP. PROVE REPAIR PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 12 April 1990
Resolved 12 April 1990
Construction/Loadline
Issued 12 April 1990
Resolved
REPAIR ABOUT 14 INCH FRACTURE INBOARD OF STBD MAIN ENGINE SEACHEST BY CHASEENDS WITH ULTRASOUND, DRILL STOP, VEE AND WELD UP. PROVE REPAIR PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 12 April 1990
Resolved 12 April 1990
Construction/Loadline
Issued 12 April 1990
Resolved
THE AREAS TEMPORARILY REPAIRED BY VEEING AND WELDING 13APR90 ARE TO BE INSERTED AT THE NEXT DRYDOCKING OF THE VESSEL, BUT NO LATER THAN 28FEB91. THESE AREAS ARE IN WAY OF THE STARBOARD RUDDER POST AND STARBOARD MAIN ENGINE SEACHEST.
Condition: Unknown
Due 12 April 1990
Resolved 12 April 1990
Construction/Loadline
Issued 2 August 1989
Resolved
CORRECT 2 WELD DEFECTS IN PORT AFT CORNER. INSERT AND TEST.
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Construction/Loadline
Issued 2 August 1989
Resolved
REPAIR FRACTURED CROSSPIECE TO #1 FRAME IN FOREPEAK.
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Engineering
Issued 30 June 1989
Resolved
REPLACE WORN FLEXI HOSE AT STBD MAIN ENGINE RAW WATER INTAKE.
Condition: Unknown
Due 30 June 1989
Resolved 30 June 1989
Lifesaving
Issued 30 June 1989
Resolved
ADD ADDITIONAL RETROREFLECTIVE TAPE TO TOP OF ALL 48 LIFE JACKETS AS DISCUSSED.
Condition: Unknown
Due 30 June 1989
Resolved 30 June 1989
Fire Fighting
Issued 30 June 1989
Resolved
REPOSITION BOTH FIRE HYDRANTS FROM POINTING UP TO EITHER DOWN OR HORIZONTAL.
Condition: Unknown
Due 30 June 1989
Resolved 30 June 1989
Construction/Loadline
Issued 30 June 1989
Resolved
CONTINUOUSLY WELD TOP OF AFT AND TWO AREAS OF FORWARD ENGINEROOM BULKHEADS.
Condition: Unknown
Due 30 June 1989
Resolved 30 June 1989
Lifesaving
Issued 30 June 1989
Resolved
REPLACE GRAB LINE ON ONE RING BUOY.
Condition: Unknown
Due 30 June 1989
Resolved 30 June 1989
Construction/Loadline
Issued 30 June 1989
Resolved
REPAIR OR REPLACE FRACTURED HANDLE AND BROKEN DOG AT AFT MAIN DECK HATCH.
Condition: Unknown
Due 30 June 1989
Resolved 30 June 1989
Electrical
Issued 8 July 1988
Resolved
REPLACE WORN MAST LIGHT WIRING.
Condition: Unknown
Due 8 July 1988
Resolved 8 July 1988
Engineering
Issued 8 July 1988
Resolved
REPAIR BILGE WARNING DEVICES AND MAKE OPERABLE.
Condition: Unknown
Due 8 July 1988
Resolved 8 July 1988
Electrical
Issued 8 July 1988
Resolved
SECURE WIRING IN ENGINEROOM WITH ADDITIONAL METAL CLAMPS.
Condition: Unknown
Due 8 July 1988
Resolved 8 July 1988
Construction/Loadline
Issued 8 July 1988
Resolved
PROVIDE ONE ADDITIONAL ANCHOR AS PER [name withheld].
Condition: Unknown
Due 8 July 1988
Resolved 8 July 1988
Engineering
Issued 8 July 1987
Resolved
CLEAN OIL FROM BILGE IN ENGINEROOM.
Condition: Unknown
Due 8 July 1987
Resolved 8 July 1987
Unknown
Issued 8 July 1987
Resolved
PROVIDE HOSE EXTENSIONS FOR HAND BILGE PUMP.
Condition: Unknown
Due 8 July 1987
Resolved 8 July 1987
Accommodation/Occupational Safety
Issued 8 July 1987
Resolved
RELABEL EMERGENCY ESCAPE HATCH'S TOP SIDE IN PASS. COMPARTMENT & WHEELHOUSE.
Condition: Unknown
Due 8 July 1987
Resolved 8 July 1987
Electrical
Issued 8 July 1987
Resolved
FILL IN OPEN SPACES OF ELECTRICAL PANEL BOXES (LOC. IN WHEELHOUSE, PASS. COMPARTMENT, ENGINEROOM) WITH BLANKS.
Condition: Unknown
Due 8 July 1987
Resolved 8 July 1987
Fire Fighting
Issued 8 July 1987
Resolved
SERVICE ALL FIRE EXTINGUISHERS PRIOR TO OPERATION.
Condition: Unknown
Due 8 July 1987
Resolved 8 July 1987
Electrical
Issued 8 July 1987
Resolved
WRAP GENERATOR EXHAUST IN LAZARETTE AREA (PORT).
Condition: Unknown
Due 8 July 1987
Resolved 8 July 1987
Unknown
Issued 8 July 1987
Resolved
SECURE BILGE BLEED VALVES, OR PLUG, TO MAINTAIN PUMP PRIME.
Condition: Unknown
Due 8 July 1987
Resolved 8 July 1987