P S is a 1970 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2017, most recently in March 2026, along with 44 deficiencies.

Records from 2017 to 2026. Most recent: inspection, 17 March 2026.

Built
1970
Last inspected
17 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 March 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE8950
474579
Flag
UNITED STATES
Maury page id
psix-474579

Documentation record

Registered dimensions (L × B × D)50.0 ft × 15.0 ft × 5.5 ft
Registered tonnagegross 27 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJENSEN MOTORBOAT CO · SEATTLE WA: REDMOND WA, UNITED STATES · built 1970
Hull materialFRP (Fiberglass)
PropulsionDiesel Direct
Hull shapeShip
Hull configurationMonohull
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 25 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Simplified, Gross Ton
22 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 14

17 March 2026 Vessel Attendance · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8312639
6 January 2025 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8047925
4 April 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7890098
24 March 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7656561
19 December 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7611076
5 May 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7444618
28 December 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7113776
21 March 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6929996
1 April 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6653452
9 April 2018 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6388350
3 April 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6384369
10 July 2017 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6277140
31 May 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6161929
20 March 2017 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6106728

Deficiency record · 44

14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 17 March 2026 Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3 or 140.4, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. Acceptable methods of securing the device include—(1) Closing the seacock and removing the handle;(2) Padlocking the seacock in the closed position;(3) Using a non-releasable wire-tie to hold the seacock in the closed position; or(4) Locking the door to the space enclosing the toilets with a padlock or door handle key lock. MI observed a type II MSD installed onboard with no capability to hold sewage. Vessel only in a no discharge zone. 705: Vessel is required to secure onboard toilets making them inaccessible for use. Submit plan for installation of a type III Marine Sanitation Device and install to the satisfaction of USCG.
Action required: 705 - Other - as specified
Due 30 April 2026
Resolved 15 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 March 2026 Resolved
Each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. MI observed the life float to in a condition deemed no longer servicable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2026
Resolved 15 May 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 March 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI observed a faceplate missing from an electrical receptacle in the overhead of the tank room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2026
Resolved 15 May 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 March 2026 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. MI observed 02 waste receptacles that were of combustible material.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2026
Resolved 15 May 2026
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 5 May 2022 Resolved
Vessel had an expired COD on board. MISLE indicated that the vessel has a valid COD. Owner/Operator could not produce a valid COD during the inspection. 46CFR67.313
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 6 May 2022
Resolution: Vessel produced photo evidence of valid COD.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 December 2020 Resolved
No proof on board of crew members being enrolled in DAPI consortium. Proof needs to be provided of valid program. 46CFR16.230
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 January 2021
Resolved 19 February 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 December 2020 Resolved
Dead end wires are present in the engine room: in the old bilge pump and on engine gauge panel. Safety cap needs be placed on the ends. 46CFR183.200
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 January 2021
Resolved 18 February 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 December 2020 Resolved
Radio Station Certificate is expired and needs to be up to date.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 January 2021
Resolved 24 February 2021
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 December 2020 Resolved
There is excessive amounts of oil on the drip pans in the engine room and they need to be cleaned out. 46CFR182.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 February 2021
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 April 2018 Resolved
Wiring in the engine room is not supported with metal supports.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 June 2018
Resolution: Master installed metal wire supports as per regulations.
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 April 2018 Resolved
Engine cooling system was modified from its original design and therefore it must meet the requirements for 46cfr182.720. Piping is pvc material. Replace piping with approved non-metallic hose or change back to original design.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2018
Resolved 25 April 2018
Resolution: reinstalled original piping
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 10 April 2018 Resolved
Exhaust system on both main engines are leaking exhaust and water. Repair to satisfaction of marine inspectors. 46CFR182.430(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2018
Resolution: Owner installed replacement turbo to fix exhaust leak on port engine.
Electrical › Electric Supply System (service) › Cable
Issued 9 April 2018 Resolved
Multiple wires in tank room found with non mechanical fittings. Wires in Saloon in aft port corner of the overhead has non mechanical fittings. Replace with mechanically secure fittings.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 25 April 2018
Resolved 25 April 2018
Resolution: Mechanically secured.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 April 2018 Resolved
Life jackets stowed below main deck. Relocate life jackets.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2018
Resolution: Relocated life jackets to the upper deck.
Engineering › Fuel Oil Service System › Valve, Control
Issued 9 April 2018 Resolved
Fuel shut off valves are not labeled.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2018
Resolution: Fuel shut off valves were labeled.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Pump, High Pressure (fuel injection)
Issued 9 April 2018 Resolved
Fuel pump on generator is leaking fuel and needs to be repaired or replaced. Generator is not to be used while passengers are on board.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 May 2018
Resolved 30 April 2019
Resolution: Verified repaired during 2019 annual
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 April 2018 Resolved
Floating ring buoy light does not have correct battery.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2018
Resolution: Replaced with correct battery.
Electrical › Electric Supply System (service) › Cable
Issued 9 April 2018 Resolved
Properly terminate dead end wires in engine room, main deck, and tank room.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 25 April 2018
Resolved 25 April 2018
Resolution: Wires secured
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 9 April 2018 Resolved
The floating waterlight attached to the life float did not flash.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2018
Resolved 3 May 2018
Resolution: Purchased and installed new battery.
Electrical › Electric Supply System (service) › Cable
Issued 9 April 2018 Resolved
Vessel used welding cable for engine starter wiring.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2018
Resolved 12 June 2018
Resolution: Installed marine grade electrical cable
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 April 2018 Resolved
Courses need to be reattached on upper deck.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 25 May 2018
Resolved 3 May 2018
Resolution: Owner/operator reinstalled cable for rails.
Electrical › Lighting (service) › Conductor
Issued 9 April 2018 Resolved
Vessel has conduit as part of the wiring for lighting.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 25 May 2018
Resolved 3 May 2018
Resolution: Owner/operator removed unauthorized wires. Wires part of an old intrusion system.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 April 2018 Resolved
Several cables and wires need to be supported with metal supports rather than zip ties.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 25 May 2018
Resolved 12 June 2018
Resolution: Installed corret wire supports above main engines.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 April 2018 Resolved
Owner/managing failed to make vessel available for drydock examination on or before 25 November 2017.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2018
Resolved 3 April 2018
Resolution: Vessel made available for drydock examination.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 31 May 2017 Resolved
Remove hot tub and associated wiring and equipment from vessel IAW 46CFR185.315.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2017
Resolution: Verified that hot tub and all associated wiring and equipment were removed from the vessel.
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 31 May 2017 Resolved
Remove cooking equipment and LPG containers or have them installed in accordance with ABYC A-1, "Marine Liquefied Petroleum Gas Systems" or Chapter 6 of NFPA 302. A CG inspection will be required prior to use if installation with above standards is preferred over removal.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2017
Resolution: Verified that LPG cooking equipment was installed IAW ABYC Marine Liquified Petroleum Gas Systems.
Engineering › Fuel Oil Service System › Piping
Issued 20 March 2017 Resolved
REPAIR HIGH PRESSURE DIESEL FUEL LEAK ON GENERATOR.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2017
Resolved 22 March 2017
Resolution: Owner repaired diesel fuel leak
Engineering › Fuel Oil Service System › Piping
Issued 20 March 2017 Resolved
REPAIR DIESEL FUEL LEAK ON FUEL MANIFOLD ON AFT BULKHEAD IN ENGINE ROOM.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2017
Resolved 22 March 2017
Resolution: Owner repaired piping diesel fuel leak
Engineering › Fuel Oil Service System › Piping
Issued 20 March 2017 Resolved
REPAIR DIESEL FUEL LEAK ON PORT MDE FUEL SUPPLY LINE.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2017
Resolved 22 March 2017
Resolution: Owner repaired fuel leak on MDE fuel supply line.
Fire Fighting › Fire Bucket › Availability
Issued 20 March 2017 Resolved
EQUIP VESSEL WITH (3) 2.5 GAL FIRE BUCKETS WITH LANYARD LONG ENOUGTH TO FILL WITH WATER FROM DECK. LABEL "FIRE BUCKET" IN CONTRASTING COLOR.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2017
Resolved 22 March 2017
Resolution: Owner purchased and properly labeled buckets. Owner provided suitable lanyard.
Documentation › Logs/Records › Drug Test Records
Issued 20 March 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2017
Resolved 22 March 2017
Resolution: Owner emailed and provided pre-employment test results.
Lifesaving › Hand Flares › Not on Board
Issued 20 March 2017 Resolved
EQUIP VESSEL WITH (3) HAND RED FLARE DISTRESS SIGNALS (USCG APPROVAL # 160.021).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2017
Resolved 22 March 2017
Resolution: Owner replaced unapproved flare gun and flares with approved red hand flares.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 20 March 2017 Resolved
REPAIR EXHAUST LEAK ON PORT MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2017
Resolved 3 April 2017
Resolution: Exhaust manifold was repaired with weld, all sat.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 20 March 2017 Resolved
MAINTAIN DAPI CONSORDIUM ROSTER OF ENROLLED EMPLOYEES. KEEP ONBOARD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 22 March 2017
Resolution: Owner provided consordium
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 20 March 2017 Resolved
POST DAPI EMPLOYEE ASSISTANCE PROGRAM (EAP) HOTLINE NUMBER IN COMMON SPACE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 6 April 2017
Resolution: EAP hotline number posted on bridge, all sat.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 20 March 2017 Resolved
MAINTAIN COMPANY DAPI POLICY/STATEMENT. KEEP ONBOARD.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 6 April 2017
Resolution: Reviewed company policy. All sat.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 20 March 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 6 April 2017
Resolution: Viewed completed training certificates.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 20 March 2017 Resolved
EQUIP LIFE FLOAT WITH USCG APPROVED (# 161.010) LIGHT WITH 18 FT LANYARD AROUND BODY OF LIFE FLOAT.
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 22 March 2017
Resolution: Owner purchased and placed new light into service
Documentation › Markings/Placards › Lifejacket Placard
Issued 20 March 2017 Resolved
PROPERLY LABEL BENCH LIFE JACKET STOWAGE WITH "LIFE JACKETS" WITH NUMBER KEPT INSIDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 22 March 2017
Documentation › Markings/Placards › Warning Signs
Issued 20 March 2017 Resolved
POST EMERGENCY INSTRUCTIONS AT OPERATING STATION VISABLE TO ALL CREW.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 22 March 2017
Resolution: Owner posted emergency instructions in operating station.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Gear, Timing
Issued 20 March 2017 Resolved
REPLACE M/E RPM GAUGE COVER AT OPERATING STATION.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 6 April 2017
Resolution: Verified gauge was replaced, all sat.
Lifesaving › Lifebuoys › Serviceable
Issued 20 March 2017 Resolved
REPLACE RETRO-REFLECTIVE TAPE ON LIFE RING.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2017
Resolved 20 March 2017
Resolution: Owner replaced retro tape.
Electrical › Electrical Distribution System (service) › Cable
Issued 20 March 2017 Resolved
PROPERLY TERMINATE DEAD END WIRES IN MAIN DECK HEAD.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 22 March 2017
Resolution: Operator properly terminated dead end wires.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 March 2017 Resolved
REMOVE EXTENTION CORD FISHED THROUGH STARBOARD VENT ON AFT BULWARK.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 22 March 2017
Resolution: Owner removed extension cord.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.