CAPT ANDERSON V

CAPT ANDERSON V is a 1973 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in May 2026, along with 104 deficiencies and 2 casualty investigations between 2002 and 2007.

Records from 2002 to 2026. Most recent: inspection, 7 May 2026.

Built
1973
Last inspected
7 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK8313
Flag
UNITED STATES
Maury page id
psix-47462

Documentation record

Registered dimensions (L × B × D)75.0 ft × 31.0 ft × 6.8 ft
Registered tonnagegross 82 / net 55
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLOREAUVILLE, LA, UNITED STATES · built 1973
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPANAMA CITY, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it82 - Regulatory (Subpart C or D), Gross Ton
55 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

7 May 2026 Vessel Attendance · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8368488
23 June 2025 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8165450
6 May 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8129737
21 November 2024 Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8038212
14 May 2024 Special Consideration · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7912253
20 September 2023 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7795887
12 September 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7786191
25 March 2023 Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7657643
14 December 2022 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7613853
7 September 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7553568
8 September 2021 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7308990
30 November 2020 Administrative Inspection · Drydock Exam · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7103498
21 September 2020 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7062062
20 June 2019 COI Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6716707
15 April 2019 Hull Examination · Examination of Repairs · Internal Structural Exam · Administrative Inspection · Damage Survey · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6662562
5 October 2018 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6555636
13 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6510348
6 August 2018 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6502279
20 June 2018 Administrative Inspection · Excursion Permit
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6450171
26 June 2017 Excursion Permit
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6189944
27 March 2017 Hull Examination · Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6112002
27 June 2016 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5920939

Deficiency record · 104

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 May 2024 Resolved
The generator is rated for 40 Celsius and needs to be derated to 80% full load rating.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 20 May 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 September 2023 Resolved
An interconnected fire detector must be installed in all areas where passengers and crew have access. The operating station doesn't have a detector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2023
Resolved 20 September 2023
Resolution: Cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 September 2023 Resolved
The survival craft requires a floating waterlight. 1 of 4 waterlights do not work. 46 CFR 180.15-1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2023
Resolved 20 September 2023
Resolution: Cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 September 2023 Resolved
Vessels shall be equipped with a suitable number of portable battery lights. The two (2) on board do not work. 46 CFR 184.30-1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2023
Resolved 20 September 2023
Resolution: Cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 September 2023 Resolved
Emergency instructions shall be posted and/or available for crew. There are no instructions on board containing instructions on what to do in the event of an emergency.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2023
Resolved 20 September 2023
Resolution: Cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 September 2022 Resolved
Inspect machinery in accordance with 46 CFR 176.804. Installed bilge system was inoperative.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2022
Resolution: Witnessed satisfactory operation of bilge system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 September 2022 Resolved
Install submersible pumps in accordance with 46 CFR 182.250. Electric submersible pump (ESP) in port eng room was configured to pump into stbd engine room. Stbd engine room ESP discharge hose material was unsatisfactory and overboard did not contain a stop valve.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2022
Resolution: ESP and associated hoses were removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 September 2022 Resolved
Inspect watertight bulkheads in accordance with 46 CFR 176.802. Port engine room bulkhead was not watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2022
Resolved 15 September 2022
Resolution: Bulkhead satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 September 2022 Resolved
Inspect machinery in accordance with 46 CFR 176.804. Stbd fuel stop valve reach rod had gap spanned by a section of rubber hose and two hose clamps.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2022
Resolved 15 September 2022
Resolution: Reach rod satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 7 September 2022 Resolved
Inspect closures in accordance with 46 CFR 176.802. Engine room vertical access hatches were seized.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2022
Resolved 15 September 2022
Resolution: Hatches operated.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2022 Resolved
Inspect electrical panels in accordance with 46 CFR 176.806. Generator panel had open holes.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2022
Resolved 15 September 2022
Resolution: Panel openings closed.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 7 September 2022 Resolved
Inspect electrical systems in accordance with 46 CFR 176.804. PA speakers were not secured.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2022
Resolved 15 September 2022
Resolution: PA speakers secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 7 September 2022 Resolved
Inspect closures in accordance with 46 CFR 176.802. Port forepeak hatch is deteriorated and in need of renewal. Complete by next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 September 2022
Resolution: Satisfactory repairs were made to forepeak hatch.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 8 September 2021 Resolved
Starboard Engine room deck hatch and soft patch leaking. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2021
Resolution: All leaks repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 September 2021 Resolved
Both Engine room stern doors and both side sliding doors missing gasket material.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2021
Resolution: Gasket material installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2021 Resolved
Starboard Engine room batteries have loose terminals.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2021
Resolution: Battery terminals properly secured.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 8 September 2021 Resolved
Port Engine room box and supports corroded; crop and renew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2021
Resolution: Wasted supports replaced and new box installed.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 8 September 2021 Resolved
Secure galley fridge and entry half door.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2021
Resolution: Fridge properly secured and door adjusted.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 September 2021 Resolved
Starboard Engine room portable fire extinguish is corroded.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2021
Resolution: Corroded extinguisher replaced.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 September 2021 Resolved
Replace all damaged engine room overhead insulation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 October 2021
Resolution: Insulation properly installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2021 Resolved
Locate and repair passenger deck overhead leak and repair water damaged lighting.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 October 2021
Resolution: Overhead leak repaired and fixture removed.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 8 September 2021 Resolved
Properly mount bilge pump in starboard engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2021
Resolution: Bilge pump properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 8 September 2021 Resolved
Install chaffing material on all fuel lines.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2021
Resolution: Chaffing material installed.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 8 September 2021 Resolved
Repair leaks in forepeak starboard overhead.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 November 2021
Resolved 10 November 2021
Resolution: Temp repairs made to deck until next DD.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 September 2021 Resolved
Properly install port forepeak reach rod.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2021
Resolution: Reach rod repaired.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 8 September 2021 Resolved
Properly secure bridge microwave, fridge, and remove power strip.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2021
Resolution: Microwave and fridge secured and all power strips removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 September 2021 Resolved
Locate and repair starboard engine exhaust leaks.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 November 2021
Resolved 10 November 2021
Resolution: Leaks identified and repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 September 2021 Resolved
Properly install electrical panels and cables in both engine room overhead. Replace any unused cables and damaged cabling.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 November 2021
Resolved 10 November 2021
Resolution: All electrical repairs conducted.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 8 September 2021 Resolved
Install machinery guard on starboard engine.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 October 2021
Resolution: Machinery guard installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 September 2021 Resolved
Install missing valve handle on port engine room stern bulkhead penetration.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2021
Resolution: New valve handle installed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 8 September 2021 Resolved
Program DSC in VHF radio.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2021
Resolution: DSC programed into VHF radio.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 8 September 2021 Resolved
Provide training on use/programming of AIS.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2021
Resolution: Training was conducted and master demonstrated familiarity with system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 September 2021 Resolved
Properly label and separate adult/child life vests.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2021
Resolution: Life Jackets properly stowed and separated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 September 2021 Resolved
Prove proper operation of port engine room bilge alarm.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2021
Resolution: New bilge float installed and tested.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 8 September 2021 Resolved
The starboard bow void overhead and internal framing has multiple fractures and poor weldments. The overhead has multiple failed weldments and an unauthorized insert. Replace deck plating with a proper insert and repair fractured framing weldments at next scheduled drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 21 September 2023
Resolution: Deck plate was replaced in DryDock.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 7 December 2020 Resolved
Repair/make watertight where the main deck stbd fire main connects with the deck.
Due 21 December 2020
Resolved 16 December 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 September 2020 Resolved
Main switchboard has a broken voltmeter and missing amp meter.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 October 2020
Resolution: Properly installed meters.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 September 2020 Resolved
Renew or replace expired EPIRB battery.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 October 2020
Resolution: Battery replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 September 2020 Resolved
Vessels main deck engine room vent dampeners need securing pins.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 October 2020
Resolution: Dampner pins installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 September 2020 Resolved
Repair or replace fuel tank vent screens.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 October 2020
Resolution: Vent screens cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 September 2020 Resolved
Remove trash, buckets, chairs from bilges throughout.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 October 2020
Resolution: Gear stowed and debri removed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 September 2020 Resolved
Repair inoperative forward masthead light, prior to operating in reduced visibility or dusk to dawn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 October 2020
Resolution: Light properly installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 September 2020 Resolved
Properly label vessel name on life floats.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 October 2020
Resolution: Life floats properly labeled.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 21 September 2020 Resolved
Repair hole in forward cabin deck. No later than the vessel's next drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 6 October 2020
Resolution: Deck wastage crop and renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 September 2020 Resolved
Re-label fuel shutoff valves (Main deck)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 October 2020
Resolution: Fuel valves labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 September 2020 Resolved
Remove apoxy and properly repair or renew holes in sewage overboard piping and holding tank. Prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 October 2020
Resolution: Wasted piping croped and renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 September 2020 Resolved
Properly install cable supports in port forward void.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 October 2020
Resolution: Cable supports installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 September 2020 Resolved
Install adequate sewage piping supports.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 October 2020
Resolution: Sewage piping supports installed.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 21 September 2020 Resolved
Provide prof of spanner wrenches for each hose station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 October 2020
Resolution: Spanner wrenches installed at both fire plugs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 September 2020 Resolved
Replace wire ties on bow void reach rod with bolts.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 October 2020
Resolution: Bolts installed on bow void suction reach rod.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 June 2019 Resolved
Port and stbd reduction gears inspection covers missing, replace and mount.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 2 July 2019
Resolution: Installed covers.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 20 June 2019 Resolved
Port engine room soft patch has wastage around mounting bolts, temporary repair is authorized (caulking). Special note to make permanent repair at next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2019
Resolved 19 July 2019
Resolution: Engine room soft patch has wasted aluminum around mounting bolts still at fwd deck, owner made temporary repairs to address the leaks, with new bolts and caulking. Permanent repairs will be needed at next dry dock.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 June 2019 Resolved
Fire pump gauge inoperative, replace and test.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2019
Resolved 2 July 2019
Resolution: Tested new gauge.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 June 2019 Resolved
Electrical distribution panel in engine missing blank covers and need breakers labeled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2019
Resolved 2 July 2019
Resolution: Installed new breaker; all satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 June 2019 Resolved
Stbd engine room enterance junction box with missing cover, replace and install.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2019
Resolved 2 July 2019
Resolution: Installed new cover.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 20 June 2019 Resolved
MSD tank Vent needs to be connected to open air vent. Port and stbd voids. Connect tank vent to main deck vent.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2019
Resolved 2 July 2019
Resolution: New vent pipe installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 June 2019 Resolved
Correct stbd morse cable from binding during operation of reduction gear. Repair and test.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2019
Resolved 2 July 2019
Resolution: Operationally tested; all satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 20 June 2019 Resolved
Cap or plug pipe 1" penetration on main deck adjacent to stbd engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2019
Resolved 2 July 2019
Resolution: Cap installed over pipe.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 June 2019 Resolved
Loose and hanging wires in #2 void center line, replace cable hangers and secure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2019
Resolved 19 July 2019
Resolution: Wires and cables were secured to new hangers.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 June 2019 Resolved
Missing life jacket donning placards for each type of life jacket onboard. Provide additional donning placards.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2019
Resolved 2 July 2019
Resolution: Appropriate life jacket donning placards installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 April 2019 Resolved
Vessel needs a thorough COI inspection to bring it back into service.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2019
Resolution: MSD Panama City completed COI inspection.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 August 2018 Resolved
The vessel is currently broadcasting (1) improper MMSI (2) improper Call Sign (3) improper beam measurement (4) improper length (5) AIS placement not provided.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 September 2018
Resolved 13 October 2020
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 August 2018 Resolved
The port rudder compartment bilge alarm is not operational; make necessary repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 6 August 2018 Resolved
There is an open ended through hull pipe penetration IWO the stbd engine compartment; properly seal the pipe.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2018
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 August 2018 Resolved
The sea painters for the life floats are spooled too tightly in the canisters which may inhibit deployment; shorten the painter to 100 feet and re-spool to insure proper deployment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2018
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 August 2018 Resolved
The man basket retaining line in one life float is deteriorated and broken; replace the line to manufacturers specifications.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 August 2018 Resolved
One life jacket has a broken clip; replace the clip.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 August 2018 Resolved
The vessel is short five life jackets; provide five additional jackets to meet full compliment. The vessel is restricted to 88 persons due to missing jackets and missing lights.
Action required: 705 - Other - as specified
Due 30 September 2018
Resolved 5 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 August 2018 Resolved
The cooling system hose on the port main engine is not the proper size; install a reducer to insure the hose fits properly.
Action required: 705 - Other - as specified
Due 31 October 2018
Resolved 8 July 2019
Resolution: Cooling system hose was replaced to proper size.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 August 2018 Resolved
The fuel filter on the generator prime mover has a funnel attached to the top which was used for priming during a recent filter change; remove the funnel and install a plug.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 August 2018 Resolved
The port steering actuator is leaking; make repairs as necessary.
Action required: 705 - Other - as specified
Due 30 September 2018
Resolved 5 October 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 August 2018 Resolved
The scuttle coaming for the #2 port void is cracked; make repairs as necessary.
Action required: 705 - Other - as specified
Due 31 October 2018
Resolved 13 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 August 2018 Resolved
The markings on two life floats have faded; properly mark the floats with the vessel name and capacity.
Action required: 705 - Other - as specified
Due 30 September 2018
Resolved 5 October 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 August 2018 Resolved
The machine screws used to mount the reach rod to the bilge suction valve in the port forepeak are too long causing it to bind; install shorter machine screws to avoid binding.
Action required: 705 - Other - as specified
Due 30 September 2018
Resolved 5 October 2018
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 9 May 2017 Resolved
Replace 14 adult life jackets due to deterioration; the vessel is restricted to the carriage of 70 passengers until corrected.
Due 8 June 2017
Resolved 14 July 2017
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 9 May 2017 Resolved
Determine the cause of open ground in two outlets in the passenger accomidations and repair as necessary.
Due 8 June 2017
Resolved 10 August 2017
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 9 May 2017 Resolved
Determine the cause of the hot/nuetral reverse in the outlet in the pilothouse and repair as necessary.
Due 8 June 2017
Resolved 14 July 2017
Fire Fighting › Fire Main › Pressure
Issued 9 May 2017 Resolved
Replace the fire main pressure gauge due to failure.
Due 8 June 2017
Resolved 14 July 2017
Fire Fighting › Nozzles › Condition
Issued 9 May 2017 Resolved
Maintenance the fire nozzle on the stbd side; bail is sticking.
Due 8 June 2017
Resolved 14 July 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 May 2017 Resolved
Provide plugs for openings in the junction box for the anchor windlass motor.
Due 8 June 2017
Resolved 10 August 2017
Construction/Loadline › Hull › Weld
Issued 9 May 2017 Resolved
Repair the fractured weld on the bow IWO the anchor line roller.
Due 8 June 2017
Resolved 14 July 2017
Construction/Loadline › Hull › Weld
Issued 9 May 2017 Resolved
Repair the fractured welds in the main deck on the bow.
Due 8 June 2017
Resolved 14 July 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 May 2017 Resolved
Provide a battery box for the aft battery in the port machinery space.
Due 8 June 2017
Resolved 14 July 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 May 2017 Resolved
Properly mount the battery switch in the port machinery space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2017
Electrical › Electrical Distribution System (service) › Panelboard
Issued 9 May 2017 Resolved
Provide a blank/cover for the open spot in the electrical panel in the port machinery space.
Due 8 June 2017
Resolved 14 July 2017
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 9 May 2017 Resolved
Provide the appropriate size breaker (20 amp) for the bilge pump in the port machinery space.
Due 8 June 2017
Resolved 14 July 2017
Construction/Loadline › Hull › Weld
Issued 9 May 2017 Resolved
Weld out the underside of the side stringers IWO the side shell replacement in the port machinery space.
Due 8 June 2017
Resolved 14 July 2017
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 May 2017 Resolved
Provide proof of a valid Certificate of Documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2017
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 9 May 2017 Resolved
Provide the vessel with a copy of the navigation rules.
Due 8 June 2017
Resolved 14 July 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 9 May 2017 Resolved
Program the MMSI number into the VHF radio and connect the radio to the GPS.
Due 8 June 2017
Resolved 10 August 2017
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 9 May 2017 Resolved
Provide a microphone for the single side band radio; the vessel is restricted to 20 miles from shore until corrected.
Due 8 June 2017
Resolved 11 May 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 May 2017 Resolved
Repair the stern light due to failure; vessel is restricted to day time operations until corrected.
Due 8 June 2017
Resolved 14 July 2017
Lifesaving › Lifefloat › Lifeline
Issued 9 May 2017 Resolved
Replace the tether lines on the life floats as necessary due to deterioration.
Due 8 June 2017
Resolved 10 August 2017
Lifesaving › Lifefloat › Paddle
Issued 9 May 2017 Resolved
Replace the retaining lines for the paddles on the life floats due to deterioration.
Due 8 June 2017
Resolved 10 August 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 May 2017 Resolved
Replace the lifeline on the lifebuoy (60 FT) due to incorrect length.
Due 8 June 2017
Resolved 14 July 2017
Engineering › Bilge Water Management System › Pump
Issued 9 May 2017 Resolved
Provide the secondary bilge pump with a secondary source of power or install a mechanically driven bilge pump.
Due 8 June 2017
Resolved 10 August 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 June 2016 Resolved
Replace first aid kit with CG approved kit or ensure all components are in rigid watertight box per 46CFR160.041-4(b)
Due 12 July 2016
Resolved 21 July 2016
Resolution: The O/O replaced the entire first aid kit with a new approved kit.
Lifesaving › Lifefloat › Pendant
Issued 28 June 2016 Resolved
Replace dryrotted tethering lines on lifefloats as needed.
Due 12 July 2016
Resolved 21 July 2016
Resolution: Dryrotted tethering lines have been replaced.
Lifesaving › Lifefloat › Painter
Issued 28 June 2016 Resolved
Replace dryrotted painter lines on both float sets (100ft)
Due 12 July 2016
Resolved 21 July 2016
Resolution: Both painter lines were replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 28 June 2016 Resolved
Make repairs to STBD MDE salt water leak at exhaust piping.
Due 12 July 2016
Resolved 21 July 2016
Resolution: New clamps have been installed along with a flexible sealant, no apparent leaks.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 28 June 2016 Resolved
Make repairs to STBD Lazarette hatch - prove watertight integrity. No offshore operations until corrected.
Due 12 July 2016
Resolved 30 June 2016
Resolution: Watertight hatch was welded and water tested with a garden hose (30 PSI).
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 June 2016 Resolved
Prove proper operation of port nav light. Daylight operations only until repaired.
Due 12 July 2016
Resolved 21 July 2016
Resolution: Port nav light was repaired, chaffed wire at the console.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 June 2016 Resolved
Remove or properly terminate dead end wire in rod locker.
Due 12 July 2016
Resolved 21 July 2016
Resolution: Wires have been capped with pressure connectors.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 June 2016 Resolved
Replace all non captive wire ends in bridge console with captive type.
Due 12 July 2016
Resolved 27 September 2016
Resolution: Non captive wire ends have been removed and replaced with captive type.

Casualty record · 2

9 April 2002Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1953544
4 June 2007Routine · role: Involved in a Marine Casualty · 1 injured · activity 2976523
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

S S WINNER QUEEN (2002–2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.