Records from 1998 to 2008. Most recent: inspection, 18 September 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
18 September 2008
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3327644
23 May 2008
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3214754
3 April 2007
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2896860
16 March 2006
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2597859
8 April 2005
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2323794
15 April 2004
Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2042553
19 August 2003
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1881322
22 April 2003
Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1789294
19 April 2002
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1608263
21 March 2002
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1495746
22 May 2001
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1373497
4 April 2000
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1455842
3 June 1999
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 807917
5 May 1999
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1369187
3 September 1998
Hull Examination · Initial Certification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1372418
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 3 April 2007
Resolved
Submit 2006 MIS report
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 13 April 2007
Resolution: Copy was sent to office
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 3 April 2007
Resolved
Double hose clamp the raw water hose.
Action required: 705 - Other - as specified
Resolved 13 April 2007
Resolution: Picture was emailed to office
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 March 2006
Resolved
Provide 2006 Certificate of Documentation.
Due 30 March 2006
Resolved 30 May 2006
Resolution: Certificate of Documentation paper work was faxed to office on this date.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 16 March 2006
Resolved
Provide documentation for fire system in the generator space.
Due 30 March 2006
Resolved 30 May 2006
Resolution: Documentation was faxed for fire system in the generator space on this date.
Electrical › Electrical Distribution System (service)
Issued 21 March 2002
Resolved
Provide flush mount for circuit breaker panel. LEGACY COMPONENT DESC: Circuit Breaker
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 April 2002
Resolved 19 April 2002
Documentation › Logs/Records
Issued 21 March 2002
Resolved
Demonstrate proper fire/man overboard drills. LEGACY COMPONENT DESC: Maneuvering Performance Test Results
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 April 2002
Resolved 19 April 2002
Navigation
Issued 22 May 2001
Resolved
PROVIDE BELL IAW 72COLREGS ANNEX III 2,E
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2001
Resolved 15 March 2002
Fire Fighting
Issued 22 May 2001
Resolved
PROVIDE PROPOSAL/ SERVICE REPORT FOR FIXED FIRE FIGHTING SYSTEM TO ALLOW PROPER OPERATION IAW46CFR 181.410(G) & 181.420.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2001
Resolved 19 April 2002
Engineering
Issued 22 May 2001
Resolved
SECURE COWLING AROUND GENERATOR.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2001
Resolved 15 March 2002
Engineering
Issued 22 May 2001
Resolved
PROVIDE FLAME SCREENS FOR AFT FUEL TANK.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2001
Resolved 15 March 2002
Accommodation/Occupational Safety
Issued 22 May 2001
Resolved
LABEL EMERGENCY EXIT IN FWD BERTHING AREA.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2001
Resolved 15 March 2002
Construction/Loadline
Issued 22 May 2001
Resolved
REPAIR/REPLACE FWD BERTHING BILGE ALARM.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2001
Resolved 19 April 2002
Accommodation/Occupational Safety
Issued 22 May 2001
Resolved
REPLACE GRAY WATER PUMP IN GENERATOR ROOM FOR GALLEY SINK.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2001
Resolved 15 March 2002
Construction/Loadline
Issued 22 May 2001
Resolved
PROVIDE AUDIO/VISUAL BILGE ALARMS IAW 46CFR 182.530.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2001
Resolved 19 April 2002
Construction/Loadline
Issued 22 May 2001
Resolved
REPLACE/REPAIR FWD BERTHING BILGE PUMP.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2001
Resolved 22 May 2001
Documentation
Issued 22 May 2001
Resolved
PROVIDE UPDATED TRAINING LOG FOR CREW IAW46CFR 185.420.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2001
Resolved 22 May 2001
Navigation
Issued 22 May 2001
Resolved
PROVIDE EMERGENCY INSTRUCTIONS AND MOUNT IAW46CFR 185.510 & 185.512
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2001
Resolved 15 March 2002
Fire Fighting
Issued 22 May 2001
Resolved
REPLACE/REPAIR SMOKE ALARM IN PASSENGER CABIN.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2001
Resolved 15 March 2002
Lifesaving
Issued 22 May 2001
Resolved
PROVIDE PUBLIC ADDRESS SYSTEM IAW46CFR 184.610.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2001
Resolved 15 March 2002
Construction/Loadline
Issued 22 May 2001
Resolved
LABEL FORWARD AND GENERATOR BILGE SWITCHES ON OPERATORS STATION PANEL.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2001
Resolved 22 May 2001
Navigation
Issued 22 May 2001
Resolved
REPLACE/REPAIR ANCHOR LIGHT.
Condition: Unknown
Due 22 June 2001
Resolved 31 May 2001
Navigation
Issued 22 May 2001
Resolved
ELECTRICALL ISOLATE RPM GUAGES FROM RADIO MICROPHONE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2001
Resolved 15 March 2002
Lifesaving
Issued 22 May 2001
Resolved
PROVIDE FIRST AID KIT IAW 46CFR 184.710.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2001
Resolved 22 May 2001
Documentation
Issued 22 May 2001
Resolved
PERMANENTLY MARK OFFICIAL NUMBER ON VESSEL IAW46CFR 67.121.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2001
Resolved 15 March 2002
Engineering
Issued 22 May 2001
Resolved
PROVIDE PROOF OF GROUNDING OF FUEL FILLS FOR BOTH FUEL TANKS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2001
Resolved 19 April 2002
Engineering
Issued 22 May 2001
Resolved
ENABLE ENGINES TO START ON EITHER BATTERY BANK.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2001
Resolved 15 March 2002
Navigation
Issued 22 May 2001
Resolved
REPLACE/REPAIR GUAGE LIGHTS AT OPERATORS STATION.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2001
Resolved 15 March 2002
Documentation
Issued 22 May 2001
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE PROFF OF EMPLOYEE DRUG TESTING PROGRAM.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2001
Resolved 19 April 2002
Lifesaving
Issued 22 May 2001
Resolved
CLEAN EXCESS OIL FROM BILGES IN ENGINEROOM AND GENERATOR ROOM.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2001
Resolved 19 April 2002
Engineering
Issued 22 May 2001
Resolved
SECURE MARINE HEAD STARTING DEVICE AS PER MANUFACTURERS INSTRUCTIONS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 June 2001
Resolved 15 March 2002
Electrical
Issued 5 May 1999
Resolved
Install Drain Plug on Oil Drain Hose on Generator.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Lifesaving
Issued 5 May 1999
Resolved
Conduct Crew Training as per 46CFR185.420/.520/.524 Fire Fighting Man Overboard Abandon Ship.
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Electrical
Issued 5 May 1999
Resolved
Seal hole on Air Intake for Generator
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999
Lifesaving
Issued 5 May 1999
Resolved
Fix STBD Engine Room Flooding Alarm 46CFR 182.530
Condition: Unknown
Due 9 June 1999
Resolved 9 June 1999