Records from 1982 to 2012. Most recent: inspection, 9 July 2012.
Inspection history · 46
9 July 2012
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4373371
26 July 2011
Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4095175
10 December 2010
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3908332
6 December 2010
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3908124
7 September 2010
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3844527
2 July 2008
Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3267774
1 July 2008
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3253388
12 July 2007
COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2991657
28 June 2007
Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2974849
5 September 2006
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2769150
1 August 2006
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2732881
21 July 2005
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2434754
22 June 2005
Examination of Repairs · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2407374
10 August 2004
Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2161925
28 July 2004
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2147753
30 September 2003
Simplified Stability Test
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1917782
15 August 2003
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1876929
30 July 2003
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1861433
2 July 2002
COI Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1639893
9 August 2001
Hull Examination · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1468668
1 June 2000
Deficiency Check · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1365799
21 July 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424782
9 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1187018
21 April 1993
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1134651
17 December 1992
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1137871
14 May 1992
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1266171
9 July 1991
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1244221
4 June 1991
Re-Inspection · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1239958
12 June 1990
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 913933
11 December 1989
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 928355
16 June 1989
COI Inspection · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1208595
7 March 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 889087
7 February 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1350220
19 December 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1035659
30 November 1988
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 898731
26 April 1988
Re-Inspection · Hull Examination · Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1344611
13 May 1987
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1028829
6 March 1987
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1325243
7 May 1986
COI Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 984715
1 October 1985
Examination of Repairs
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1300801
14 June 1985
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 981704
15 May 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 981145
15 August 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1285140
9 August 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1285134
9 August 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1272011
29 March 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 967037
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 9 July 2012
Resolved
MSD vent pipe was held together with duck tape.
Due 11 September 2012
Resolved 3 August 2012
Lifesaving › Lifefloat › Retroreflective Material
Issued 9 July 2012
Resolved
Retro tape was worn and needs to be replaced
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2012
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 9 July 2012
Resolved
Line for the float free waterlight needs to be replaced and installed by splicing the line around the body of the lifefloat
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2012
Navigation › Piloting/Steering › Compass Deviation Table
Issued 9 July 2012
Resolved
Vessel did not have a compass deviation table on board
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2012
Lifesaving › Lifebuoys › Serviceable
Issued 9 July 2012
Resolved
Retro tape needs to be replaced
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2012
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 July 2012
Resolved
All lifesaving equipment needs to have the vessels name re-stenciled due to the current markings being faded
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2012
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 July 2012
Resolved
Emergency lighting in the engine room did not work
Due 11 September 2012
Resolved 3 August 2012
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 July 2012
Resolved
Emergency lighting, lighting the path to the exit needs to be installed in the crew lounge. Lighting needs to self actuate upon loss of main power source.
Due 11 September 2012
Resolved 3 August 2012
Fire Fighting › Ventilation Systems › Ducts
Issued 9 July 2012
Resolved
Vent closures on the main deck were painted in the down possition.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2012
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 7 September 2010
Resolved
Day Shapes not maintained onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2010
Resolution: Day Spapes maintained onboard.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 7 September 2010
Resolved
Charts not maintained onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2010
Resolution: Charts maintained onboard.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 7 September 2010
Resolved
Waste Management Plan not maintained onboard.
Due 7 October 2010
Resolved 9 September 2010
Resolution: Maintained Waste management Plan onboard.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 September 2010
Resolved
Liftjacket storage not marked.
Action required: 705 - Other - as specified
Due 7 October 2010
Resolved 9 September 2010
Resolution: Marked lifejacket storage.
Electrical › Electric Supply System (service) › Cable
Issued 1 August 2006
Resolved
Remove all dead end wires from engine room and under console on bridge.
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 3 August 2006
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 1 August 2006
Resolved
Prove proper operation of generator overspeed trip.
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 11 August 2006
Fire Fighting › Fire Main › Material
Issued 1 August 2006
Resolved
Place guard over belt on starboard MDE/fire pump
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 3 August 2006
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 1 August 2006
Resolved
Properly secure/mount all loose hard piping in engine room and machine room.
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 3 August 2006
Lifesaving › Lifebuoys › Stowage
Issued 1 August 2006
Resolved
Properly secure line and lights on life rings.
Action required: 705 - Other - as specified
Due 1 September 2006
Resolved 3 August 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 July 2003
Resolved
Provide on board not under command lights as required by COLREG's.
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 25 July 2005
Navigation
Issued 30 July 2003
Resolved
Provide current compass deviation table.
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 15 August 2003
Resolution: Provided.
Engineering › Bilge Water Management System › Not Installed
Issued 30 July 2003
Resolved
Provide bilge alarms as required by 46 CFR 182.530.
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 25 July 2005
Construction/Loadline
Issued 30 July 2003
Resolved
Provide stability letter on board vessel.
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 15 August 2003
Lifesaving › Liferaft Equipment › Paddle
Issued 2 July 2002
Resolved
Vessels name was not painted on paddle.
Condition: Improper/Lack of Maintenance
Due 2 August 2002
Resolved 2 July 2002
Resolution: Vessel personel painted vessels name on paddle.
Engineering
Issued 9 August 2001
Resolved
Replace fuel vent hose support clamps for fuel tank located in the steeringspace.
Condition: Unknown
Due 9 August 2001
Resolved 13 August 2001
Navigation
Issued 9 August 2001
Resolved
Provide lubrication for the steering linkage pins.
Condition: Unknown
Due 9 August 2001
Resolved 13 August 2001
Lifesaving
Issued 9 August 2001
Resolved
Starboard engine mounts are not properly installed. No locking features arepresent and the forward outboard mount in not properly engaged.
Condition: Unknown
Due 9 August 2001
Resolved 13 August 2001
Engineering
Issued 9 August 2001
Resolved
Both engine crank case covers have fitting for vent tube with no tube installed.
Condition: Unknown
Due 9 August 2001
Resolved 13 August 2001
Construction/Loadline
Issued 9 August 2001
Resolved
Starboard Hatch cover missing seal.
Condition: Unknown
Due 9 August 2001
Resolved 13 August 2001
Navigation
Issued 9 August 2001
Resolved
Hydraulic reservoir is missing (2) aft mount bolts.
Condition: Unknown
Due 9 August 2001
Resolved 13 August 2001
Navigation
Issued 9 August 2001
Resolved
Hydraulic steering system supply line chaffing near reservoir._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 2001
Resolved 13 August 2001
Navigation
Issued 9 August 2001
Resolved
(4) steering assist hydraulic lines are chaffing below the pilot house werethe lines turn vertical in the galley void.
Condition: Unknown
Due 9 August 2001
Resolved 13 August 2001
Construction/Loadline
Issued 9 August 2001
Resolved
Repair fractured weld in the steering space on the aft end of the #1 port deck longitudinal.
Condition: Unknown
Due 9 August 2001
Resolved 13 August 2001
Construction/Loadline
Issued 9 August 2001
Resolved
Remove aluminum pipe resting in bilge on starboard side of steering space. Pipe has worn groove in deck from persistant movement.
Condition: Unknown
Due 9 August 2001
Resolved 13 August 2001
Electrical
Issued 9 August 2001
Resolved
Wiring for Steering Compartment bilge alarm need packing material at bulkhead penetration.
Condition: Unknown
Due 9 August 2001
Resolved 13 August 2001
Navigation
Issued 9 August 2001
Resolved
Steering assist hydraulic lines routed from the reservoir to the pilot house are unsupported and chaffing against one another.
Condition: Unknown
Due 9 August 2001
Resolved 13 August 2001
Construction/Loadline
Issued 9 August 2001
Resolved
Repair (2) fractured welds on Port and Starboard side of forward transversedeck stiffener under galley.
Condition: Unknown
Due 9 August 2001
Resolved 13 August 2001
Electrical
Issued 9 August 2001
Resolved
Replace wiring junction box mounted on starboard hull under galley. Box is heavily corroded.
Condition: Unknown
Due 9 August 2001
Resolved 13 August 2001
Construction/Loadline
Issued 9 August 2001
Resolved
Art end of both starboard and port rub rails have holes and need repair.
Condition: Unknown
Due 9 August 2001
Resolved 13 August 2001
Construction/Loadline
Issued 9 August 2001
Resolved
Starboard Engine room hatch cover missing dogs to secure the covers.
Condition: Unknown
Due 9 August 2001
Resolved 13 August 2001
Documentation
Issued 1 June 2000
Resolved
Provide waste management plan for vessel.
Condition: Unknown
Due 22 June 2000
Resolved 22 June 2000
Lifesaving
Issued 1 June 2000
Resolved
Properly lash paddles to life floats.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Lifesaving
Issued 1 June 2000
Resolved
Provide proper float free link for both life floats. Both 8 man life floatswere each connected to a seperate float free link for an 11 to 20 man life float.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Navigation
Issued 1 June 2000
Resolved
Provide additional retaining devices (e.g. double nutts) for starboard rudder post.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Electrical
Issued 1 June 2000
Resolved
Relabel breaker numbers/items in breaker box in bridge area. Numbers are not legible.
Condition: Unknown
Due 22 June 2000
Resolved 22 June 2000
Engineering
Issued 1 June 2000
Resolved
Label/stencil remote fuel shutoff and direction of device_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 June 2000
Resolved 22 June 2000
Navigation
Issued 1 June 2000
Resolved
Post emergency broadcast placard at radio station.
Condition: Unknown
Due 22 June 2000
Resolved 22 June 2000
Navigation
Issued 1 June 2000
Resolved
Provide updated tide table and tidal current table publications.
Condition: Unknown
Due 22 June 2000
Resolved 22 June 2000
Documentation
Issued 21 July 1999
Resolved
VESSEL ROUTE RESTRICTED TO LIMITED COASTWISE, NOT MORE THAN 20 NAUTICAL MILES FROM HARBOR OF SAFE REFUGE UNTIL SIMPLIFIED STABILITY TEST IS CONDUCTED FOR AN EXPOSED ROUTE.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Engineering
Issued 14 May 1992
Resolved
REAPIR STARBOARD LEAKING EXHAUST LINE IN AFTER STEERING THAT EXTENDS FROM THE GENERATOR.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Construction/Loadline
Issued 14 May 1992
Resolved
REPAIR HULL FRACTURE ON PILOT HOUSE, PORT SIDE BELOW WINDOW.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Navigation
Issued 14 May 1992
Resolved
RENEW WIRING TO PORT AND STARBOARD NAVIGATIONAL WIRING, DUE TO CORROSION_x001C_ AND MAY NO LONGER BE WEATHER TIGHT.
Condition: Unknown
Due 29 May 1992
Resolved 11 June 1992
Navigation
Issued 14 May 1992
Resolved
REPAIR OR REPLACE VESSEL SSB RADIO.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Engineering
Issued 19 December 1988
Resolved
INSTALL NEW FACE FOR FREQUENCY METER.
Condition: Unknown
Due 19 December 1988
Resolved 19 December 1988
Construction/Loadline
Issued 19 December 1988
Resolved
INSTALL CAPTURE CHAINS ON ALL WEATHER DECK HATCHES.
Condition: Unknown
Due 19 December 1988
Resolved 19 December 1988
Electrical
Issued 19 December 1988
Resolved
INSTALL COVER FOR PORT BATTERY BOX.
Condition: Unknown
Due 19 December 1988
Resolved 19 December 1988
Construction/Loadline
Issued 19 December 1988
Resolved
SECURE COLLISION BHD PENETRATIONS.
Condition: Unknown
Due 19 December 1988
Resolved 19 December 1988
Lifesaving
Issued 19 December 1988
Resolved
STENCIL CAPACITY ON LIFEFLOAT, LASH OARS TO SAME, TIE UP PENDENTS. INSTALLMISSING PENDENT (12' LONG) ON STBD LIFEFLOAT. SECURE WEBBING ON STBD LIFEFLOAT.
Condition: Unknown
Due 19 December 1988
Resolved 19 December 1988
Documentation
Issued 19 December 1988
Resolved
PROVIDE VALID FCC STATION LICENSE AND RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 19 December 1988
Resolved 19 December 1988
Navigation
Issued 30 November 1988
Resolved
UPON ARRIVAL FT MYERS, FL. AND PRIOR TO CARRING PASSENGERS OR FREIGHT FOR HIRE YOU ARE REQUIRED TO HAVE VESSEL'S ROUTE OF OPERATION AMENDED BY [name withheld], FL TO ALLOW VESSEL OPERATION IN THAT ZONE.
Condition: Unknown
Due 30 November 1988
Resolved 30 November 1988
Construction/Loadline
Issued 26 April 1988
Resolved
RENEW PLATE OUTBOARD BATTERY BOX.
Condition: Unknown
Due 26 April 1988
Resolved 26 April 1988
Accommodation/Occupational Safety
Issued 9 August 1984
Resolved
MAKE OPERABLETHE INSTALLED MARINE SANITATION DEVICE
Condition: Unknown
Due 9 August 1984
Resolved 9 August 1984
Electrical
Issued 9 August 1984
Resolved
RENEW THE ELECTRICAL WIRE FOR THE PORT NAVIGATION LIGHT, PLUG AS PER 46 CFR 183.05-45 AND INSTALL SAME PER 46 CFR 183.05-50.
Condition: Unknown
Due 9 August 1984
Resolved 9 August 1984
Lifesaving
Issued 9 August 1984
Resolved
RENEW ALL LIFELINES ATTACHED TO THE 3 LIFEFLOATS AS PER 46 CFR 183.15-5(A)
Condition: Unknown
Due 9 August 1984
Resolved 9 August 1984
Lifesaving
Issued 9 August 1984
Resolved
RENEW ALL LINES ON THE RING LIFE BOUYS AS PER 46 CFR 180.30-1
Condition: Unknown
Due 9 August 1984
Resolved 9 August 1984
Navigation
Issued 9 August 1984
Resolved
PROPERLY SECURE THE RADIO ANTENNA ATTACHED TO THE MAST SO AS TO BE RIGID
Condition: Unknown
Due 9 August 1984
Resolved 9 August 1984
Lifesaving
Issued 9 August 1984
Resolved
PROVIDE FOR THE LIFEFLOATS THE PAINTER AND FLOAT-FREE LINK. ATTACH AS PER 46CFR180.20
Condition: Unknown
Due 9 August 1984
Resolved 9 August 1984