Records from 1984 to 1996. Most recent: inspection, 22 November 1996.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
22 November 1996
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1180782
19 November 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 185030
13 September 1996
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1363761
14 August 1996
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1374689
5 March 1996
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 886246
8 February 1996
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1187028
28 April 1995
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1178787
14 March 1995
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 861636
4 February 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1164431
19 November 1993
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1358231
27 August 1993
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1150780
28 July 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 845329
3 February 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 960768
3 August 1992
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 947889
21 November 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1247749
27 December 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1230223
29 November 1990
COI Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 912930
5 January 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 929440
20 November 1989
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1243514
17 November 1989
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1226648
17 November 1988
Hull Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 894179
20 November 1987
Hull Examination · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1025366
24 November 1986
Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1018547
27 November 1984
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1282364
Lifesaving
Issued 13 September 1996
Resolved
PROVIDE VESSEL NAME AND RETROREFLECTIVE TAPE ON RINGBUOYS.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Construction/Loadline
Issued 13 September 1996
Resolved
SEAL ENGINEROOM FORWARD BULKHEAD.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Engineering
Issued 13 September 1996
Resolved
REPLACE INLET TRANSMISSION HYDRAULIC HOSE TO PUMP IN ENGINEROOM.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Engineering
Issued 13 September 1996
Resolved
PROVIDE ENGINE CHANGEOUT INFORMATION AS DISCUSSED.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Lifesaving
Issued 13 September 1996
Resolved
STENCIL VESSEL'S NAME AND NUMBER OF PERSONS ACCOMODATED, ADD RETROREFLECTIVE TAPE, ATTACH PAINTER, GRABLINES, AND PENDANTS.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Lifesaving
Issued 13 September 1996
Resolved
PROVIDE/REPAIR 8 PFDS. NUMBER OF PASSENGERS ALLOWED IS 14 UNTIL THIS ITEM IS COMPLETE.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Documentation
Issued 13 September 1996
Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION FOR VESSEL WITH UPDATED OWNER INFORMATION. VESSEL HAS NO CERTIFICATE OF DOCUMENTATION ON BOARD.
Condition: Unknown
Due 19 September 1996
Resolved 21 October 1996
Documentation
Issued 13 September 1996
Resolved
PROVIDE RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 19 September 1996
Resolved 21 October 1996
Navigation
Issued 13 September 1996
Resolved
PROVIDE LIGHT LIST AND CURRENT, UNDAMAGED CHART OF THE OPERATING AREA.
Condition: Unknown
Due 19 September 1996
Resolved 21 October 1996
Documentation
Issued 13 September 1996
Resolved
PROVIDE RADIO STATION LICENSE.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Documentation
Issued 13 September 1996
Resolved
PROVIDE RADIO OPERATORS PERMIT.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Fire Fighting
Issued 13 September 1996
Resolved
PROVIDE COPY OF FIRE EXTINGUISHING REPORT (JULY/AUGUST) FOR PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Electrical
Issued 13 September 1996
Resolved
REMOVE ALL DEAD-END, NOT IN USE WIRING THROUGHOUT VESSEL (E/R, STEERING ROOM, BERTHING SPACES, MIDBODY)
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Construction/Loadline
Issued 13 September 1996
Resolved
SEAL COVER ABOVE ENGINEROOM AND HOSE TEST WEATHERTIGHTNESS.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Documentation
Issued 13 September 1996
Resolved
PROVIDE DRUG TESTING PROGRAM.
Condition: Unknown
Due 19 September 1996
Resolved 21 October 1996
Accommodation/Occupational Safety
Issued 13 September 1996
Resolved
INSTALL REMOTE SHUTOFF (FUEL) FOR DIESEL STOVE.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Deck/Cargo
Issued 13 September 1996
Resolved
DEMONSTRATE WINCH OPERATION.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Navigation
Issued 13 September 1996
Resolved
CONDUCT UNDERWAY TEST INCLUDING OPERATION OF STEERING, ENGINE, ELECTRONICS,AND MAN OVERBOARD TEST.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Construction/Loadline
Issued 13 September 1996
Resolved
CAP OFF OVERBOARD DISCHARGE FOR & REMOVE ELECTRICAL BILGE PUMP IN ENGINEROOM THAT IS NO LONGER IN USE. (ABOVE WATERLINE)
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Engineering
Issued 13 September 1996
Resolved
PROVIDE PERMANENT CONNECTION ON END OF HYDRAULIC FILL HOSE.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Engineering
Issued 13 September 1996
Resolved
PROVIDE VENT CLOSURE FOR ENGINEROOM NATURAL VENT OPENING.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Lifesaving
Issued 13 September 1996
Resolved
PROVIDE PFD DONNING PLACARD.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Lifesaving
Issued 13 September 1996
Resolved
PROVIDE EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Navigation
Issued 13 September 1996
Resolved
PROVIDE DEVIATION CARD.
Condition: Unknown
Due 19 September 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 13 September 1996
Resolved
TEST BILGE/FIRE PUMP.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Unknown
Issued 13 September 1996
Resolved
PROVIDE FLASHLIGHTS FOR EMERGENCY LIGHTING.
Condition: Unknown
Due 19 September 1996
Resolved 22 October 1996
Documentation
Issued 13 September 1996
Resolved
PROVIDE UPDATED SENIOR DECKHAND LETTER.
Condition: Unknown
Due 19 September 1996
Resolved 21 October 1996
Construction/Loadline
Issued 14 August 1996
Resolved
RENEW BROKEN WELDS BETWEEN DECK LONGITUDINALS AND DECK ON STARBOARD AFT SIDE OF LAZARETTE.
Condition: Unknown
Due 22 August 1996
Resolved 22 August 1996
Construction/Loadline
Issued 14 August 1996
Resolved
REWELD DECK FRAMING PIECES TOGETHER IN LAZARETTE.
Condition: Unknown
Due 22 August 1996
Resolved 22 August 1996
Construction/Loadline
Issued 14 August 1996
Resolved
REPAIR HOLES IN BULKHEAD NEAR DECK BETWEEN LAZARETTE AND FUEL TANK SPACE.
Condition: Unknown
Due 4 September 1996
Resolved 22 August 1996
Construction/Loadline
Issued 8 February 1996
Resolved
SUBMIT PLANS FOR BILGE ALARM INSTALLATION
Condition: Unknown
Due 31 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 8 February 1996
Resolved
COMPLETE INTERNAL EXAMINATION OF ENGINE ROOM AND MIDSHIP COMPARTMENT
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Accommodation/Occupational Safety
Issued 8 February 1996
Resolved
RENEW WOODEN RAILING, PORTSIDE AFT
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Accommodation/Occupational Safety
Issued 8 February 1996
Resolved
REFASTEN AND SEAL WOODEN RAILING, PORTSIDE TRANSOM
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Construction/Loadline
Issued 8 February 1996
Resolved
RENEW GASKETS ON WATERTIGHT SCUTTLES AT CHAIN LOCKER AND LAZARETTE
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Construction/Loadline
Issued 8 February 1996
Resolved
SUBMIT REPAIR PROPOSAL TO CROP AND RENEW PORTION OF MAIN DECK AND CENTER STRINGERS FORWARD OF SCUTTLE TO LAZARETTE
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Unknown
Issued 8 February 1996
Resolved
PROVIDE COPY OF HULL GAUGING REPORT CONDUCTED 28SEP95
Condition: Unknown
Due 31 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 8 February 1996
Resolved
REATTACH RAILING, STARBOARD SIDE AT GATE
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Electrical
Issued 14 March 1995
Resolved
INSTALL GLOBES IN LAZZERETTE FOR LIGHTING.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Accommodation/Occupational Safety
Issued 14 March 1995
Resolved
MAKE PERMINANT REPAIRS TO TEMPORARILY REPAIRED WINDOWS IN THE HOUSE.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Lifesaving
Issued 19 November 1993
Resolved
PROVIDE SIX UNEXPIRED HANDHELD SMOKE MARKER PYROTECHNIC DEVICES.
Condition: Unknown
Due 30 November 1993
Resolved 13 December 1993
Lifesaving
Issued 19 November 1993
Resolved
PROVIDE FOR SEPARATION/PARTITION BETWEEN ADULT AND CHILD LIFEJACKETS AND CLEARLY MARK STORAGE LOCATION IN ONE INCH LETTERS.
Condition: Unknown
Due 30 November 1993
Resolved 13 December 1993
Lifesaving
Issued 19 November 1993
Resolved
PROVIDE TWO ADDITIONAL TYPE 1 ADULT LIFEJACKETS. PASSENGERS ARE LIMITED UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 30 November 1993
Resolved 13 December 1993
Construction/Loadline
Issued 27 August 1993
Resolved
DDX WORK LIST ITEM - PROVIDE AN ADDITIONAL 120 SQUARE INCHES OF FREEING PORT AREA. ALSO REMOVE OR REPLACE OLD RUBBER FLAPS OUTBOARD OF FREEING PORTS. NO PASSENGERS MAY BE CARRIED UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 12 September 1993
Resolved 23 November 1993
Engineering
Issued 27 August 1993
Resolved
DDX WORK LIST ITEM - REPLACE PROPELLOR ZINC.
Condition: Unknown
Due 11 September 1993
Resolved 23 November 1993
Lifesaving
Issued 27 August 1993
Resolved
DDX WORK LIST ITEM - PROVIDE A CAP OR PLUG TO FRESH WATER TANK REMOVABLE ONLY BY MECHANICAL ACTION.
Condition: Unknown
Due 11 September 1993
Resolved 23 November 1993
Accommodation/Occupational Safety
Issued 27 August 1993
Resolved
DDX WORK LIST ITEM - PROVIDE A SIGN OR STENCIL ON OR NEAR MSD OVERBOARD DISCHARGE VALVE STATING "DO NOT DISCHARGE IN U.S. WATERS".
Condition: Unknown
Due 11 September 1993
Resolved 23 November 1993
Electrical
Issued 27 August 1993
Resolved
DDX WORK LIST ITEM - REMOVE OR RECONNECT WIRING FROM SHORE POWER CONNECTIONTO JUNCTION BOX IN LAZARETTE.
Condition: Unknown
Due 11 September 1993
Resolved 22 November 1993
Construction/Loadline
Issued 27 August 1993
Resolved
DDX WORK LIST ITEM - CLEAN GASKET AND DECK SEAT OF LAZERETTE HATCH TO PROVEWATERTIGHTNESS.
Condition: Unknown
Due 11 September 1993
Resolved 22 November 1993
Fire Fighting
Issued 27 August 1993
Resolved
DDX WORK LIST ITEM - HAVE ALL FIRE EXTINGUISHERS SERVICED.
Condition: Unknown
Due 11 September 1993
Resolved 22 November 1993
Lifesaving
Issued 27 August 1993
Resolved
DDX WORK LIST ITEM - REMOVE OIL FROM BILGES.
Condition: Unknown
Due 11 September 1993
Resolved 22 November 1993
Construction/Loadline
Issued 27 August 1993
Resolved
DDX WORK LIST ITEM - CLEAN AND TREAT WITH FUNGICIDE THE FURRING ON THE PLYWOOD OVERHEAD IN THE ENGINEROOM.
Condition: Unknown
Due 11 September 1993
Resolved 22 November 1993
Electrical
Issued 27 August 1993
Resolved
DDX WORK LIST ITEM - REPLACE WIRING FROM JUNCTION BOX TO FRESHWATER PUMP WITH PROPER MARINE GRADE WIRING. ALSO PROPERLY CLAMP WIRING AT EXIT POINT IN JUNCTION BOX TO PREVENT CHAFING.
Condition: Unknown
Due 11 September 1993
Resolved 23 November 1993
Electrical
Issued 27 August 1993
Resolved
DDX WORK LIST ITEM - PROPERLY MOUNT FRESH WATER PUMP IN A FIXED POSITION.
Condition: Unknown
Due 11 September 1993
Resolved 23 November 1993
Electrical
Issued 17 November 1989
Resolved
PROVIDE OVERCURRENT PROTECTION IN FEDDER CABLE BETWEEN BATTERY BOX AND MAIN BREAKER BOARD.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Electrical
Issued 17 November 1989
Resolved
PROVIDE CIRCUIT PROTECTION FOR NEWLY INSTALLED AUTO PILOT CIRCUIT.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Engineering
Issued 17 November 1989
Resolved
INSTALL PROPERLY SIEZED BILGE PUMP IN ICE HOLD.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Electrical
Issued 17 November 1989
Resolved
REPLACE FEDDER CABLE TO MAIN BREAKER BOX WITH CABLE OF ADEQUATE SIZE.
Condition: Unknown
Due 17 November 1989
Resolved 17 November 1989
Construction/Loadline
Issued 17 November 1988
Resolved
INSTALL VALVES OR HARD PIPE THE KEEL COOLER.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988