MAURY USCG vessel records Sign in
← All vessels

HERCULES 156

HERCULES 156 is a 1982 mobile offshore drilling unit. The Coast Guard has recorded 14 inspections since 1998, most recently in September 2004, along with 66 deficiencies.

Records from 1998 to 2004. Most recent: inspection, 28 September 2004.

Built
1982
Last inspected
28 September 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8750144 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HO0 5031
474781
Flag
PANAMA
—
Maury page id
psix-474781

Inspections, by type

…with no type recorded2
Years with a record 6 calendar years (1998–2004)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it2124 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 14

28 September 2004 COC-MODU Renew
Type not classified · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2194690
9 December 2002 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1716343
15 October 2002 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1690217
17 May 2002 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1624578
17 November 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1076153
14 May 2001 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1063758
1 May 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1384761
8 May 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1471015
31 March 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 172275
16 December 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 812593
20 May 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 168379
6 May 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1437568
18 February 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1129238
19 May 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1446651

Deficiency record · 66

Electrical
Issued 8 November 2002 Resolved
Prove purge alarm or shutdown of oilfield instrumentation box (monitor) upon loss of purge air.
Due 16 November 2002
Resolved 3 December 2002
Lifesaving › Lifeboat
Issued 8 November 2002 Resolved
Prove proper operation of #2 lifeboat. Total persons onboard limited to 58 until this item is cleared. Prove engine, leak on control valve & sprinkler system.
Due 16 November 2002
Resolved 3 December 2002
Operations/Management
Issued 8 November 2002 Resolved
Provide accurate muster list for 80 POB and indicate 2nd in-command for each boat designated for use on muster list.
Due 8 December 2002
Resolved 3 December 2002
Electrical
Issued 1 May 2001 Resolved
PROVIDE DOCUMENTATION OF PROPER OPERATION OF TOTAL RIG SHUTDOWN.
Condition: Unknown
Due 14 May 2001
Resolved 14 May 2001
Deck/Cargo
Issued 8 May 2000 Resolved
Conduct test of relief valve on drill floor.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Lifesaving
Issued 8 May 2000 Resolved
Provide equipment list for both lifeboats and operating manual for port lifeboat.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Construction/Loadline
Issued 8 May 2000 Resolved
Clean and pressure wash transformer room due to gray water in bilges.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Fire Fighting
Issued 8 May 2000 Resolved
Provide standard discharge connection.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Construction/Loadline
Issued 8 May 2000 Resolved
Replace bracket on deck under obstruction light battery box.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Fire Fighting
Issued 8 May 2000 Resolved
Post operating instructions and proper labeling at fixed CO2 stations.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Accommodation/Occupational Safety
Issued 8 May 2000 Resolved
Provide and/or replace light bulbs at rack lights in accommodation spaces.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Electrical
Issued 8 May 2000 Resolved
Label electrical breaker boxes.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Accommodation/Occupational Safety
Issued 8 May 2000 Resolved
Repair doors in accomodation spaces.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Documentation
Issued 8 May 2000 Resolved
Provide third party inspection report for port crane when repairs are complete.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Construction/Loadline
Issued 8 May 2000 Resolved
Crop and renew wasted steel at walkway between house and heliport: 3 underdeck supports and 1 handrail.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Documentation
Issued 6 May 1999 Resolved
Provide Panamanian approved SOPEP that has the required geographic specificinformation required by the coastal state (U.S.)
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Navigation
Issued 6 May 1999 Resolved
Provide correct flashing sequence characteristics for NAVAID (obstruction) lights. Must flash in accordance with 33 CFR Part 67 (60 flashes per minute).
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Lifesaving
Issued 6 May 1999 Resolved
Provide documentation that both lifeboats' davit cables have been renewed within the last four years.
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Accommodation/Occupational Safety
Issued 6 May 1999 Resolved
Make drill floor air receiver available for internal visual inspection by ABS surveyor or CG inspector of provide alternate means jof demonstrating material condition of steel shell; i.e., NDT (ultrasonic gauging).
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Fire Fighting
Issued 6 May 1999 Resolved
Renew emergency fire pump discharge check valve and prove proper operation of fire pump (no leaks).
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Accommodation/Occupational Safety
Issued 6 May 1999 Resolved
Repair sanitary water system pump and prove proper operation of sanitary (flushing) water system.
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Lifesaving
Issued 6 May 1999 Resolved
Provide better system of detecting loss-of-ventilation (relative pressure differential) between mud pit room and mud pump room per the intent of IMO MODU Code (1979) Regulation 6.3.1.2.
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Electrical
Issued 6 May 1999 Resolved
Provide method for testing main generator low lube oil pressure shutdown operation.
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Lifesaving
Issued 6 May 1999 Resolved
Ensure all remaining switches, breakers, controller, etc., in SCR room and throughout MODU have been labeled in English.
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Lifesaving
Issued 6 May 1999 Resolved
Ensure inflatable liferafts and their attachements (painter) to the weak link and hydrostatic reliease arrangements are per directions given and/or instructions labeled on raft canister.
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Lifesaving
Issued 6 May 1999 Resolved
Refill one three breathing air cylinders (completely empty) on stbd lifeboat.
Condition: Unknown
Due 12 July 1999
Resolved 12 July 1999
Lifesaving
Issued 6 May 1999 Resolved
Conduct operational testing of both lifeboats' releasing gear at 110 percent of maximum load in accordance with 46 CFR 109.301(i)(5) OR provide documentation that this test has been conducted and witnessed by the flag state administration or authorized classification society within last 5 yrs
Condition: Unknown
Due 6 May 1999
Resolved 6 May 1999
Documentation
Issued 19 May 1998 Resolved
PROVIDE WASTE MANAGEMENT PLAN
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Fire Fighting
Issued 19 May 1998 Resolved
MAKE NECESSARY ADJUSTMENTS TO REMOTE PULL CABLE FOR FIXED FIRE FIGHTING SYSTEM FOR GENERATOR ROOM SO AS TO PROVE PROPER OPERATION.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Lifesaving
Issued 19 May 1998 Resolved
REPLACE THE #1 LIFE BOAT COMPASS.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 19 May 1998 Resolved
ACQUIRE A TOWING BRIDLE FOR THE #1 LIFE BOAT.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 19 May 1998 Resolved
INSTALL THE DATA PLATE FOR THE DAVIT NEXT TO THE DRUM ON THE #1 LIFE BOAT.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 19 May 1998 Resolved
REPAIR THE SPRINKLER SYSTEM ON THE #1 LIFE BOAT.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Fire Fighting
Issued 19 May 1998 Resolved
MOUNT CO2 BOTTLE BANK INSTRUCTIONS AT BOTTLE BANK STATION
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Fire Fighting
Issued 19 May 1998 Resolved
PROVIDE PROPER APPLICATORS TO MATCH UP WITH NOZZLES FOR HELO DECK FIRE STATIONS.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Lifesaving
Issued 19 May 1998 Resolved
REINSTALL LIFERAFTS TO COMPLY WITH MAXIMUM INSTALLATION HEIGHT REQUIREMENT,ENSURE EMBARKATION AREA FITTED WITH "E" LIGHTS.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Navigation
Issued 19 May 1998 Resolved
PROVE PROPER OPERATION OF SIDE RUNNING LIGHTS
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Construction/Loadline
Issued 19 May 1998 Resolved
PROVIDE COMPLETED THIRD PARTY REPORTS TO USCG ON BENCH TESTING RESULTS FOR ALL AIR AND BULK TANK RECEIVERS PRESSURE RELIEVE DEVICES.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Fire Fighting
Issued 19 May 1998 Resolved
LABEL 2 RED GENERAL ALARM BELLS IN SEA CHEST ROOM OVERHEAD, ADJACENT TO GENERATOR BULKHEAD.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Fire Fighting
Issued 19 May 1998 Resolved
MOUNT DISCHARGE HOSE ON CO2 WHEEL UNIT ON HELO DECK
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Documentation
Issued 19 May 1998 Resolved
MARK "ESCAPE LADDER" ON FORWARD HELO DECK LADDER EGRESS
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Lifesaving
Issued 19 May 1998 Resolved
REPAINT AFT HELODECK PERIMENTER MARKING TO CORRESPOND WITH PERIMETER LIGHTING.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Electrical
Issued 19 May 1998 Resolved
REMOVE DEAD ENDED CABLE OR PLACE IN JUNCTION BOX WIRING ADJACENT TO CONTROLHOUSE.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Lifesaving
Issued 19 May 1998 Resolved
MARK TRIPPING HAZARD ON E-GEN DECK, PORT SIDE WEATHER DECK, VALVE ON DECK WALKWAY.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Documentation
Issued 19 May 1998 Resolved
PROVIDE PROPER LICENSES AS PROVIDED FOR ON PANAMANIAN SAFE MANNING CERTIFICATE OR GAIN EXEMPTION FROM FLAG STATE IN WRITING.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Electrical
Issued 19 May 1998 Resolved
PROVIDE NON-CONDUCTING BLANKS THROUGHOUT RIG WHERE MISSING.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Engineering
Issued 19 May 1998 Resolved
PROVIDE CAPS/PLUGS FOR ALL FUEL AND OIL TANK DRAINS.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Electrical
Issued 19 May 1998 Resolved
REPLACE PLASTIC WIRE RUN TIES WITH IEEE APPROVED CLIPS
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Electrical
Issued 19 May 1998 Resolved
REPAIR/REMOVE DEAD-ENDED WIRING IN DRY STORES ROOM.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Documentation
Issued 19 May 1998 Resolved
UPDATE TO CURRENT 46CFR108/109
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Electrical
Issued 19 May 1998 Resolved
PROVIDE BLANKS FOR PANELS IN GALLEY, MESSDECK, BATHROOM #2.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Electrical
Issued 19 May 1998 Resolved
REPAIR "E" LIGHTS FOR THE PASSAGEWAY ADJ. TO LAUNDRY ROOM, PASSAGEWAY ADJ. TO TOOL PUSHERS OFFICE.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Fire Fighting
Issued 19 May 1998 Resolved
REPLACE BATTERY IN SMOKE DETECTOR IN TOOL PUSHERS ROOM.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Lifesaving
Issued 19 May 1998 Resolved
REMOVE DEFEDTIVE OXYGEN CYLINDER FROM TREATMENT ROOM.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Electrical
Issued 19 May 1998 Resolved
PROVE PROPER OPERATION OF EMERGENCY GENERATOR STARTER.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Electrical
Issued 19 May 1998 Resolved
RENEW CABLE RUUN IN MUD PUMP ROOM.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Construction/Loadline
Issued 19 May 1998 Resolved
INSTALL SELF CLOSING DEVICE ON MUD PIT DOOR.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Electrical
Issued 19 May 1998 Resolved
LABEL ALL "E" LIGHTS, PREPARE SAME FOR TESTING BY USCG
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Electrical
Issued 19 May 1998 Resolved
REPAIR SPLICED CABLE IN MUD PIT ROOM.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Fire Fighting
Issued 19 May 1998 Resolved
PROVE PROPER OPERATION OF #2 FIRE PUMP.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Lifesaving
Issued 19 May 1998 Resolved
PROVE PROPER OPERATION OF NEGATIVE VENTILATION FOR MUD PIT ROOM.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Electrical
Issued 19 May 1998 Resolved
PROVE PROPER OPERATION OF REVERSE POWER RELAY FOR #2 MAIN GENERATOR
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Electrical
Issued 19 May 1998 Resolved
REMOVE DEAD-ENDED WIRING RUNNING OVER WATER TIGHT DOOR LEADING TO TRANSFORMER SPACE.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Electrical
Issued 19 May 1998 Resolved
PROVE PROPER OPERATION OF LOW LO TRIP ON EMERG GEN.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Construction/Loadline
Issued 19 May 1998 Resolved
ADJUST LOOSE DOGS FOR WATERTIGHT DOORS IN GALLEY, TOP LEVEL STARBOARD SIDE,TOP QRTRS PORTSIDE, AND CONTROL HOUSE.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Unknown
Issued 19 May 1998 Resolved
LABEL ALL EMERGENCY SHUT DOWNS IN ENGLISH.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.