Records from 2016 to 2025. Most recent: inspection, 18 June 2025.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 June 2025
Resolved
Make available for inspection, the space forward of the collision bulkhead prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 11 August 2025
Resolution: all sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 23 June 2025
Resolved
Make all through hull valves at or below the waterline available for inspection prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 11 August 2025
Resolution: all sat
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 June 2025
No resolution recorded
COI expired on 29MAY25. Complete satisfactory COI Renewal Inspection prior to carrying passengers for hire to include testing of bridge equipment, lifesaving, fire fighting, high water alarms, bilge sytems, propulsion systems, drills, etc.
Action required: 701 - Prior to carriage of passengers/cargo
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 23 June 2025
Resolved
Ensure EPIRB is registered with correct UIN.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2025
Resolution: correctly registered
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 June 2025
Resolved
Vessel had 6 day/night flares and is required 6 day and 6 night flares. Provide 6 additional approved day or night flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2025
Resolution: all sat
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 5 August 2024
No resolution recorded
Ensure crew is enrolled in CG approved random drug testing program and have completed pre-employment test prior to serving in a safety sensitive position.
Action required: 701 - Prior to carriage of passengers/cargo
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 5 August 2024
Resolved
Provide valid FCC Station License
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2024
Resolved 18 September 2024
Resolution: FCC Station License provided.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 5 August 2024
No resolution recorded
Conduct satisfactory drills in presence of CG Marine Inspector
Action required: 701 - Prior to carriage of passengers/cargo
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 5 August 2024
Resolved
Ensure EPIRB is registered with correct UIN
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2024
Resolved 18 September 2024
Resolution: registered
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 August 2024
Resolved
Fixed bilge discharge has a slow leak. Repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2024
Resolved 18 September 2024
Resolution: repaired, operational test sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 May 2023
Resolved
Repair or replace ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 14 June 2023
Resolution: Renewed
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 May 2023
Resolved
Provide one additional daytime flare for a total of six day and six night.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 14 June 2023
Resolution: provided
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 May 2023
Resolved
Restore stern light to proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 14 June 2023
Resolution: operational
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 26 May 2023
Resolved
Add guard to forward berthing area light to prevent mechanical damage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 14 June 2023
Resolution: guard added
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 26 May 2023
Resolved
Provide evidence of preemployment drug testing of all crewmembers with negative results received prior to operating in commercial service.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2023
Resolution: evidence provided
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 May 2023
Resolved
Restore ship's whistle to proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 14 June 2023
Resolution: operational
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 May 2023
Resolved
Remove temporary battery charging installation or make permanent IAW 46 CFR 183.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 14 June 2023
Resolution: removed
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 May 2023
Resolved
Provide generator switch wiring arrangement that complies with 46 CFR 183.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2023
Resolved 14 June 2023
Resolution: new approved cable
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 September 2022
Resolved
Vessel has been out of the water since fall 2021 waiting for engine work to be done. Vessel must complete satisfactory annual inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2023
Resolution: def check complete
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 July 2021
Resolved
Ensure proper operation of horn.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 15 July 2021
Resolution: operational
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 July 2021
Resolved
Prove proper operation of fixed bilge system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 26 May 2023
Resolution: test sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 July 2021
Resolved
Ensure there are guards on rotating machinery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 14 June 2023
Resolution: installed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 May 2020
Resolved
FCC Station license is expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2020
Resolved 18 May 2023
Resolution: cert is valid
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 June 2019
Resolved
Prove proper operation of fixed bilge pump
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 18 July 2019
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 June 2019
Resolved
Provide current NOAA registration for EPIRB.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 9 August 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 June 2019
Resolved
Repair inoperable bilge high level alarm - audible - for galley space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 18 July 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 June 2019
Resolved
Replace expired battery in lifebuoy water light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 18 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2018
Resolved
Vessels garden hose for firefighting cpaability did not have a corrosion resistant nozzle and the ability to go from spray /straight stream.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2018
Resolution: New nozzle provided during deficiency check.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2018
Resolved
Vessel's lifebuoy was not marked with vessel's name and retroreflective material was faded beyond operational capability.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2018
Resolution: New lifebuoy provided for deficiency check.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 11 June 2018
Resolved
Vessel had dead end wires under navigation console.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2018
Resolution: Dead end wires removed upon reinspection.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 11 June 2018
Resolved
Vessel's fuel shut off valves did not provide protection from crew injury as they were within the space.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2018
Resolution: Fuel shutoff valved reconfigured to be utilized from outside the space.
Navigation › Piloting/Steering › US Coast Pilot
Issued 24 May 2016
Resolved
Provide updated nav pubs to include Coast Pilot [name withheld], Current Table, Tide Tables and Nav rules.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 26 July 2017
Operations/Management › Pollution › Control of Garbage
Issued 24 May 2016
Resolved
Provide waste management plan.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 26 July 2017
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 May 2016
Resolved
Replace STBD MDE raw water hose.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 26 July 2017
Engineering › Fuel Oil Service System › Hose
Issued 24 May 2016
Resolved
Replace return fuel hose for generator.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 26 July 2017
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 May 2016
Resolved
Install guards or railing to block access to Port MDE belts.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 26 July 2017
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 24 May 2016
Resolved
Clean oil out of engine room bilge.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 26 July 2017
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 24 May 2016
Resolved
Provide employee assistance drug and alcohol hot line phone number.
Action required: 705 - Other - as specified
Due 24 June 2016
Resolved 26 July 2017