CABANA
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Northeast District (CGD-NE) · Other hulls named CABANA
CABANA is a 1973 passenger vessel (inspected). The Coast Guard has recorded 84 inspections since 1985, most recently in January 2026, along with 155 deficiencies and 2 operational controls.
Records from 1985 to 2026. Most recent: inspection, 21 January 2026.
- Built
- 1973
- Last inspected
- 21 January 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 155 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
547272
WDE7589
47484
Flag
UNITED STATES
367395120
Maury page id
psix-47484
Inspections, by type
…with no type recorded7
Years with a record
38 calendar years (1985–2026)
The 84 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)79.1 ft × 31.5 ft × 8.3 ft
Registered tonnagegross 98 / net 82
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · WARREN, RI, UNITED STATES · built 1973
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
82 - Regulatory (Subpart C or D), Net Ton
82 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDE7589MMSI 367395120 · active · compulsorily equipped · granted 28 November 2018, expires 13 February 2029
WTQ3470MMSI 366929740 · expired · compulsorily equipped · granted 6 March 2004, cancelled 19 July 2014 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 84
21 January 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8299312
14 November 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8265088
31 August 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8221930
31 August 2025
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8236801
14 April 2025
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8111172
28 February 2024
Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7867624
6 November 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7820689
30 May 2023
In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7700166
8 March 2023
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7647769
26 July 2021
Internal Structural Exam · Deficiency Check · Damage Survey · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7268708
18 December 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7112923
4 November 2020
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7089456
13 February 2020
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6910461
26 February 2019
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6633936
12 November 2018
Drydock Exam · Damage Survey · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6580450
3 April 2018
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6383914
30 October 2017
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6297786
22 March 2017
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6109778
6 January 2017
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6066772
2 December 2016
Drydock Extension · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6057949
18 March 2016
Deficiency Check · Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5836056
3 May 2012
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4300584
23 February 2011
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3950523
9 February 2010
COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3677079
22 April 2009
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3459097
26 February 2009
Annual Inspection · Administrative Inspection · Deficiency Check · MTSA Verification · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3424451
28 March 2008
Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3174795
13 March 2007
Deficiency Check · MARPOL Annex V Examination · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2886558
28 February 2007
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2879352
8 March 2006
Annual Inspection · MARPOL Annex V Examination · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2598393
22 February 2005
Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2296780
8 February 2005
Deficiency Check · MTSA Verification · COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2288404
5 April 2004
Deficiency Check · MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2037500
25 November 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1954785
12 March 2003
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1756124
27 March 2002
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1597947
9 May 2001
Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1436576
29 March 2001
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1370067
15 February 2000
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1438974
9 June 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1460313
30 March 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1397118
12 March 1999
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1400930
26 February 1999
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 798569
16 February 1999
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1469236
22 March 1998
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 788233
6 March 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1120012
17 February 1998
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 777085
18 March 1997
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1098251
18 February 1997
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1106643
21 February 1996
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1192634
8 September 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1186980
29 March 1995
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1142294
22 February 1995
MARPOL Annex V Examination · Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1161284
15 February 1995
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 854197
17 February 1994
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 853737
24 February 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1150196
17 February 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 840103
5 February 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1138673
30 July 1992
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 961832
10 March 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1263268
19 February 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 956048
19 February 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 915769
9 January 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1244599
16 July 1990
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1217166
17 April 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 909590
6 April 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 922676
20 February 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1227616
17 May 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 895342
7 March 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1206229
22 February 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1045305
19 January 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1040636
21 July 1988
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340621
25 February 1988
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1330659
16 December 1987
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1313536
17 July 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1023984
26 May 1987
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1337470
27 April 1987
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1314880
3 April 1987
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1024735
4 March 1987
Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1312496
24 March 1986
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1310832
29 January 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 997477
3 January 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 990117
11 January 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 977686
3 January 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 977685
Deficiency record · 155
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 31 August 2025
Resolved
All passenger accommodations must be arranged and
equipped to provide for the safety of the passengers in
consideration of the route, modes of operation, and
speed of the vessel. Due to marine casualty, vessel has
damage to 02 windows midships starboard side (01 missing
and 01 cracked) adjacent to gangway.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 April 2025
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MIs observed rotating machinery not protected by guards or rails on both the port and stbd service generators. Rectify deficiency within 7 days.
46 CFR 177.960
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 March 2024
Resolved
Fire main pipe has a hole IWO galley Ice Machine, must make proper repairs.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 March 2024
Resolved
Vessel has missing structural fire protection insulation in engine room, engine room trunk, and behind bar at the corner. Must fix to original and approved type.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 March 2024
Resolved
Electrical distribution panel in galley, engine room, engine room trunk, and top deck locker need to be properly labeled with name plate.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 14 March 2024
Resolved
The public address system was not located throughout the vessel, zero on the second deck, and the speaker on the main deck was not working properly, must add enough speakers to cover entire vessel in all operating conditions.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 March 2024
Resolved
Life jacket stowage on 2nd deck needs proper labeling.(number)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 March 2024
Resolved
Both gauges for lube oil & jacket water at the helm are glazed over and/or not working, must replace or repair as needed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 14 March 2024
Resolved
Vessel needs updated and current charts of operating area. (2018)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 14 March 2024
Resolved
Port side main deck 2nd window is cracked causing a haz to passengers
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 March 2024
Resolved
Ring buoys need new retro and vessels name.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 March 2024
Resolved
All scuttles on the main deck must be weathertight, have a retention line, and work properly.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 March 2024
Resolved
All rugs and carpets shall be of wool or other material having equivalent fire resistive qualities.
(Flame spread rating 75 & smoke developing rating not to exceed 100; ASTM E701-84)
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 14 March 2024
Resolved
Vessel needs to update the General Arraignment and structural fire protection plans to reflect current arrangement, specifically taking into consideration space categorization, fire doors, fire loads, and means of escape.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 28 February 2024
Resolved
(b) An abandon ship drill must be conducted as follows: (1) Each member of the crew shall participate in at least one abandon ship drill each month. Last documented abandon ship drill was in September 2023.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 28 February 2024
Resolved
(b) A fire drill must be conducted at least once each month. Last documented fire drill was in September 2023.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 28 February 2024
Resolved
(e) Each rescue boat required in accordance with § 117.210 of this subchapter must be launched with its assigned crew aboard and maneuvered in the water as if during the actual man overboard situation;
(1) Once each month, if reasonable and practicable; but (2) At least once within a 3 month period before the vessel gets underway with passengers.
Last documented Man Overboard drill was in September 2023.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 28 February 2024
Resolved
(a) Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels... Insufficient documentation onboard for three of four crew members enrollment in a DAP screening program.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 28 February 2024
Resolved
(b) Qualifications. The Vessel Security Officer (VSO) must have general knowledge, through training or equivalent job experience, in the following:
(1) Those items listed in § 104.210 (b)(1) and (b)(2) of this part;
(2) Vessel layout;
(3) The VSP and related procedures, including scenario-based response training;
(4) Crowd management and control techniques;
(5) Operations of security equipment and systems;
(6) Testing and calibration of security equipment and systems, and their maintenance while at sea; and
(7) TWIC.
The Captain, the VSO by default, was unaware of positional responsibilities & the vessel's VSP.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 February 2024
Resolved
...all vessels shall be provided with not less than two avenues of escape from all general areas accessible
to the passengers or where the crew may be quartered or normally employed... The Galley's original aft means of escape has been permanently blocked by a dance floor over the exit.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 February 2024
Resolved
Vessels contracted for on or after July 1, 1961, which carry more than 150 passengers shall meet the requirements of subpart 72.05 of Subchapter H... Evaluated in accordance with 46 CFR 72.05 and the vessel's approved Structural Fire Protection (SFP) Plan, MI observed multiple missing fire doors at the top of stairwells or doors of an unapproved type.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 February 2024
Resolved
Rugs and carpet may be used in addition to deck coverings. Rugs and carpets must be constructed of 100 percent wool or equivalent as determined by the regulation, MI observed deck coverings main dk & upper deck not of an approved type.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 February 2024
Resolved
Furniture such as chairs, sofas, and similar items are tested and meet the requirements in UL 1056 “Fire Test of Upholstered Furniture,” or meet the requirements in § 72.05–55 in subchapter H of this chapter. MI doubts the fire resistance of furnishings observed on main deck and upper deck. Operator will provide proof that installed all furnishings are of an approved type and in accordance with the vessel's SFP Plan or regulation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 February 2024
Resolved
Ceilings, linings, and any furring incidental to their installation in control spaces, passageways, stairways, accommodation spaces and service spaces must be of noncombustible material in accordance with § 164.009 in subchapter Q of this chapter, or other standard specified by the Commandant. MI observed plastic decorative flowers. Operator will remove all decorations not of an approved type or accounted for in SFP Plan.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 February 2024
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable, the vessel has some modifications
Without documented MSC approval, MI notes the following modifications to the vessel not captured in the construction, general arrangement, and SFP plan drawings:
1)enclosure of upper deck with combustible materials
2)construction of security room and lifejacket locker with combustible materials
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 February 2024
Resolved
Furniture such as chairs, sofas, and similar items are tested and meet the requirements in UL 1056 “Fire Test of Upholstered Furniture,” or meet the requirements in § 72.05–55 in subchapter H of this chapter. MI doubts the fire resistance of furnishings observed on main deck and upper deck. Operator will provide proof that installed all furnishings are of an approved type and in accordance with the vessel's SFP Plan or regulation.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2023
Resolved
"All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection."
-Electrical outlets on main deck are not properly secured.
-Electrical outlet on fwd port side, main deck has cracked face plate.
-Light is missing bulb and cover in the stowage locker on main deck aft.
-Junction box in the stowage locker on main deck aft is not properly secured to the wall.
-Dead end wires found in the stowage locker on main deck aft.
-Junction box found daisy chained to another Junction box in the stowage locker on main deck aft.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 May 2023
Resolved
"Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection." Extinguisher on main deck, midship does not have bracket for portable extinguisher
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 March 2023
Resolved
AUXILIARY MACHINERY SHALL BE SUITABLE IN TYPE AND DESIGN FOR THE PURPOSE INTENDED. POWER TAKE OFF PIPING FOUND WITH SOFT PATCH. REPLACE DISCHARGE PIPE AND PROVIDE PHOTOGRAPHIC EVIDENCE OR REPAIR.
46 CFR 182.10-1 (Old T)
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 26 July 2021
Resolved
THIS VESSEL IS A "TL-BOAT", THEREFORE NOT REQUIRED A SAFETY MANAGEMENT SYSTEM (SMS) PER REGULATION. SECTOR NY
HAS FOUND THE FOLLOWING DEFICIENCIES TO BE OBJECTIVE EVIDENCE THAT A SERIOUS SUBSTANDARD CONDITION HAS NOT BEEN PRO-ACTIVELY MANAGED BY THE VESSEL'S OWNER/OPERATOR, LEADING TO A LACK OF SAFETY CULTURE ONBOARD THE VESSEL.
46 CFR 176.25-50
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 July 2021
Resolved
REPAIRS OR ALTERATIONS TO THE HULL, MACHINERY OR EQUIPMENT THAT AFFECT THE SAFETY OF THE VESSEL MUST NOT BE MADE WITHOUT THE APPROVAL OF THE COGNIZANT [name withheld] TO HAVE A HOLE IN ITS HULL UNDER THE WATERLINE IN THE PORT SIDE GALLEY BILGE SPACE. THE HOLE
OCCURRED AS A RESULT FROM THE VESSEL'S CREW PERFORMING
UNAUTHORIZED REPAIRS AND ALTERATIONS.
VESSEL WILL BE DETAINED UNTIL THE FOLLOWING ARE ALL COMPLETED/APPROVED BY THE USCG:
1)24/7 BILGE WATER LEVEL WATCH UNTIL APPROVED TEMPORARY REPAIRS ARE MADE AND WATER INGRESS INTO GALLEY SPACE HAS BEEN SECURED.
2)SUBMIT A REPAIR PLAN FOR TEMPORARY PATCH FOR SAFE
PASSAGE TO DRYDOCK YARD.
3)SUBMIT A TOW PLAN TO DESIRED DRYDOCK YARD.
4)VISITING MARINE INSPECTORS MUST VERIFY ALL APPROPRIATE TEMPORARY MEASURES ARE PUT IN PLACE PRIOR TO INITIATING TOW PLAN TO DRYDOCK YARD.
5)ONCE AT DRYDOCK YARD, VESSEL WILL BE REQUIRED TO COMPLETE ALL WORK LIST ITEMS IDENTIFIED FROM NOVEMBER 2020 DRYDOCK EXAM (MISLE #7089456) AND ANY ADDITIONAL ITEMS FROM SUBSEQUENT JULY 2021 DAMAGE SURVEY (MISLE #7268708). ALL REPAIRS AND ALTERATIONS TO DEFICIENT HULL AREAS MUST BE TO THE SATISFACTION OF THE CONGNIZANT OCMI.
46 CFR 115.700
46 CFR 116.300
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 February 2019
Resolved
Make aft watertight bulkhead in galley watertight.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 February 2019
Resolved
Remove oil containers stored in accommodation space
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 February 2019
Resolved
Label fire extinguishers
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 February 2019
Resolved
If hazardous or combustible material is stored onboard it must be stored in an approved locker.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 February 2019
Resolved
Repair leaks on the port side generator
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2019
Resolved
Repair leaks on the port side main engine
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2019
Resolved
Repair fuel filter leak
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 26 February 2019
Resolved
Replace insulation in engine space
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 February 2019
Resolved
Replace cover on a/c unit in galley
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 26 February 2019
Resolved
Refasten overhead light in galley
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 February 2019
Resolved
Ensure lights might UL standard
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 February 2019
Resolved
Tighten all battery connections
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 3 April 2018
Resolved
Provide current company policy and enrolled crew members of the drug and alcohol program.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 3 April 2018
Resolved
Prove proper operation of depth sounder.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 3 April 2018
Resolved
Over 10 amps of ground detected on shore side power. Correct ground and provide causal analysis.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 3 April 2018
Resolved
Properly label engine room generator breaker panel opposite pilot house supply and 12 VDC current panel.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 3 April 2018
Resolved
Label volt meter.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 April 2018
Resolved
Replace navigation lights.
Fire Fighting › Fire Main › Valves
Issued 22 March 2017
Resolved
Vessel must repair a leaking fire main valve. 46CFR176.25-25
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 22 March 2017
Resolved
Vessel must replace all reflective material as discussed on most life jackets with new material. 46CFR180.25-25(a)
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 22 March 2017
Resolved
Vessel must install ground dectection on electrical distribution panel. 46CFR183.10-30 & 46CFR111.35-1(j)
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 March 2016
Resolved
Condemned 17 Kapok type life jackets. Replace with serviceable lifejackets. Vessel is not to operate with more than 320 pax until proper PFDs are installed.
Electrical › Electrical Distribution System (service) › Cable
Issued 18 March 2016
Resolved
Permanently install CCTV in pilot house. Remove extension cords.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 March 2016
Resolved
04 Unapproved Lights in accomodation space. Install UL listed lights.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 March 2016
Resolved
Floatlight broken and equipped with incorrect battery.
Electrical › Electric Generation Source (service) › Generator
Issued 3 May 2012
Resolved
Prove operation of starboard generator.
Lifesaving › Hand Flares › Expired
Issued 3 May 2012
Resolved
Replace all flares.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 3 May 2012
Resolved
Prove operation of emergency lights.
Electrical › Lighting (service) › Lighting Fixture
Issued 23 February 2011
Resolved
Provide light cover on light in pilot house.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 23 February 2011
Resolved
Provide current light list.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 23 February 2011
Resolved
Provide current corrected charts for the areas the vessel operates.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 23 February 2011
Resolved
Prove proper operation of the emergency light on the ladies room forward.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 February 2011
Resolved
Prove proper operation of the bilge high level audible alarm.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 February 2011
Resolved
Provide eye wash in first aid kit.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 February 2010
Resolved
Prior to carrying passengers, vessel must conduct underway man-overboard drill to be witness by a Coast Guard Marine Inspector.
Personnel › Training › First Aid/CPR
Issued 27 March 2009
Resolved
Provide proof of training for basic first aid and CPR for at least fifty percent of the crew.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 March 2009
Resolved
Prove proper operation of the anchor light.
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 March 2009
Resolved
Properly secure 12 volt battery located in the wheelhouse console. Battery is used for backup power for the bilge high water alarm system.
Stability › Watertight Integrity › General
Issued 11 March 2009
Resolved
Properly stuff wire penetrations through the forward watertight bulkhead in the galley located on the portside.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 March 2009
Resolved
Remove or properly secure in a junction box dead end wiring located in the portside void IWO the restrooms.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 11 March 2009
Resolved
Provide covers for two electrical junction boxes located on the port side, galley void IWO the compressors for the reefer units.
Construction/Loadline › Penetrations › Pipe Flange
Issued 28 March 2008
Resolved
Remove duct tape from pipe in P/S engine room and properly blank the same as discussed, at next scheduled dry dock period.
Construction/Loadline › Hull › Longitudinal Frame
Issued 28 March 2008
Resolved
C/R 2nd/3rd SS wasted longs, at next scheduled dry dock period.
Electrical › Electric Generation Source (service) › Conductor
Issued 28 March 2008
Resolved
Make necessary repairs to wasted battery box IWO P/S generator.
Electrical › Electric Generation Source (service) › Conductor
Issued 28 March 2008
Resolved
Make necessary repairs to wasted battery box IWO S/S generator at next scheduled dry dock.
Construction/Loadline › Hull › Longitudinal Frame
Issued 28 March 2008
Resolved
C/R longs #2&3 stbd side engine room blkd (IWO air intake fan). At next DD period.
Electrical › Electric Generation Source (service) › Conductor
Issued 28 March 2008
Resolved
Properly dead all loose wiring IWO Stbd generator set.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 28 March 2008
Resolved
Replace cracked windows on decks #1 P/S window#1 and 7 from aft and S/S window #7 from aft, as discussed.
Construction/Loadline › Hull › Hull Plating
Issued 28 March 2008
Resolved
C/R holes on both sides of exhaust tunnel in aft void on transom Stbd side. Prior to next DD.
Engineering › Bilge Water Management System › Piping
Issued 13 March 2007
Resolved
Make permanent repairs to pin hole leak in bilge water discharge piping.
Engineering › Lubricating Oil Service System › Hose
Issued 13 March 2007
Resolved
Replace worn lubricating oil hose in way of port main engine.
Communications › Alarms/Indicators › High Water Alarm
Issued 13 March 2007
Resolved
Prove proper operation of audible bilge high water alarm.
Construction/Loadline › Hull › Side Shell
Issued 28 February 2007
Resolved
Gauge areas surrounding 03 areas on port side of hull required to be cropped and renewed. Provide gauging report to USCG OCMI.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 8 March 2006
Resolved
Replace cracked bridge window (stbd side window).
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 8 March 2006
Resolved
Both upper and lower bar found with non-GFI outlets. Replace 6 outlets (3 outlets upper and 3 lower bar) with approved GFI outlets.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 8 February 2005
Resolved
Provide a copy of the required employer policy that is part of the company's drug and alcohol program (EAP program).
Fire Fighting › Structural - A Class Divisions
Issued 5 April 2004
Resolved
Make permanent repairs to latch mechanism on (port side) Galley Fire. LEGACY COMPONENT DESC: Openings - Fire Doors
Lifesaving
Issued 25 March 2003
Resolved
Make repairs to welds in resuce platform, and perform a sat man overboard drill in the presence of a Marine Inspector.
Accommodation/Occupational Safety › Medical/First Aid
Issued 25 March 2003
Resolved
Re-stock First Aide kit
Electrical › Electrical Distribution System (service)
Issued 25 March 2003
Resolved
Replace receptacle in galley IWOF sink by emergency escape hatch with a ground fault receptacle.
Electrical › Electrical Distribution System (service)
Issued 25 March 2003
Resolved
Permanently mount receptacle in soda compressor room.
Engineering › Bilge Water Management System
Issued 25 March 2003
Resolved
Propperly lable bilge high level alarm pannel in wheel house.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 25 March 2003
Resolved
Mount a non-conductive handrail on main distribution pannel in engine room.
Construction/Loadline › Hull
Issued 12 March 2003
Resolved
V/W flatened weld IWO inboard keel cooler starboard side.
Construction/Loadline › Hull
Issued 12 March 2003
Resolved
Crop and renew stiffner above port exhaust.
Construction/Loadline › Hull
Issued 12 March 2003
Resolved
V/W flatened weld IWO keel cooler and insert port side.
Electrical › Lighting (service)
Issued 12 March 2003
Resolved
Place guard or remove light fixture in between port generator and main engine.
Accommodation/Occupational Safety › Cooking Systems
Issued 12 March 2003
Resolved
Clean grill and deep fat fryer in galley prior to use.
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 27 March 2002
Resolved
Repair or remove both main generator tachometers. LEGACY COMPONENT DESC: Tachometers
Accommodation/Occupational Safety
Issued 9 May 2001
Resolved
Repair latch of both port & stbd aft passenger embarkation gates
Lifesaving
Issued 9 May 2001
Resolved
Properly stow beverage CO2 bottle. (Located in storeroom aft deck)
Accommodation/Occupational Safety
Issued 9 May 2001
Resolved
Reinstall missing support for deep fat fryer.
Accommodation/Occupational Safety
Issued 9 May 2001
Resolved
Remove and renew grease in deep fat fryer, clean area surrounding fryer.
Electrical
Issued 9 May 2001
Resolved
Remove dead end wiring in stereo unit area
Accommodation/Occupational Safety
Issued 9 May 2001
Resolved
Provide sign on main deck labeling emergency escape from Galley
Electrical
Issued 9 May 2001
Resolved
Repair or replace broken light fixture and remove improper wiring stereo areas.
Electrical
Issued 9 May 2001
Resolved
Remove improper wiring (speaker wiring) at engine room entrance
Engineering
Issued 9 May 2001
Resolved
Repair leaking fuel lines/ racor filter. Renew oil soaked A60 insulation on bulkhead.
Construction/Loadline
Issued 9 May 2001
Resolved
Install 3" coaming at aft weather tight door on main deck.
Construction/Loadline
Issued 29 March 2001
Resolved
Remove galley space deck to concrete ballast at wings on both port and starboard sides for examination. Replace in kind structures found to be wasted.
Electrical
Issued 29 March 2001
Resolved
Behind mens head on port side. Seal and repack where wire enters juction box on bulkhead in to mens head.
Construction/Loadline
Issued 29 March 2001
Resolved
C/R Port and Starboard cargo door hinges iwo frame for door.
Construction/Loadline
Issued 29 March 2001
Resolved
Rework fire pump intake for seavalve in engine space so that it will seat properly when secured.
Construction/Loadline
Issued 29 March 2001
Resolved
C/R Sideshell aft starboard sideshell IWO engine room space below wing tank.
Construction/Loadline
Issued 29 March 2001
Resolved
C/R, Sideshell IWO engine room on starboard side IWO turn.
Construction/Loadline
Issued 12 March 1999
Resolved
Crop & renew rubrail mounts centerline IWO windows #12 & 13.
Construction/Loadline
Issued 12 March 1999
Resolved
Gauge aft 6" wide section of tank IWO staircase, crop & renew as needed.
Construction/Loadline
Issued 12 March 1999
Resolved
Crop & renew forward frame at entrance in MSD tank, weld/attach first crossmember on port side.
Construction/Loadline
Issued 12 March 1999
Resolved
Crop & renew bilge strainer located in galley bilge.
Construction/Loadline
Issued 12 March 1999
Resolved
Crop & renew transeverse deck longitudinal #1 IWO bay 1.
Construction/Loadline
Issued 12 March 1999
Resolved
Crop & renew bilge pipe from strainer to elbow IWO bay 9 in restroom bilge area.
Construction/Loadline
Issued 12 March 1999
Resolved
Crop & renew rubrail mounts centerline IWO window 19.
Electrical
Issued 12 March 1999
Resolved
Replace broken 240v plug and missing cover located in passenger accomodations at port bow.
Lifesaving
Issued 16 February 1999
Resolved
PROVIDE PROPOSAL TO MEET RESCUE BOAT REQUIREMENTS 46 CFR 180.10-35/117.210 AND NYCMI POLICY 1/89. IF RESCUE BOAT IS PROVIDED IT MUST MEET REQ 46 CFR 160.056.
Electrical
Issued 16 February 1999
Resolved
MOUNT JUNCTION BOXES, PROVIDE WIRE SUPPORTS, REMOVE DEAD END WIRES, PROVIDEPROPER + BUS TIE AND FUSE PANEL, AND ROUTE WIRES CLEAR OF CONTROL LINKAGES.
Lifesaving
Issued 17 February 1998
Resolved
Vessel missing evacuation plan IAW 46CFR116.520.
Electrical
Issued 17 February 1998
Resolved
Missing electrical grade matting for switchboard.
Construction/Loadline
Issued 17 February 1998
Resolved
Correct bilge overboard discharge piping.
Electrical
Issued 17 February 1998
Resolved
Clean battery terminals for both port and stbd generator.
Documentation
Issued 17 February 1998
Resolved
Missing 46CFR parts 90-139 subchapter K.
Electrical
Issued 17 February 1998
Resolved
Battery box charger needs labeling.
Electrical
Issued 18 February 1997
Resolved
LABEL CIRCUIT BREAKERS IN ELECTRICAL BOX LOCATED IN ENGINEROOM TRUNK.
Construction/Loadline
Issued 22 February 1995
Resolved
VEE OUT AND WELD A 06 INCH CRACK IN HULL PLATE INSERT ON PORT SIDE MIDSHIPSAT ENGINE ROOM 1.5 FEET ABOVE WATERLINE. VSL IS NOT TO OPERATE UNTIL REPAIRS ARE COMPLETE AND A HOSE TEST OF REPAIRS ARE WITNESSED BY A MARINE INSPECTOR.
Construction/Loadline
Issued 15 February 1995
Resolved
VEE OUT AND WELD A 6" CRACK IN HULL PLATE INSERT ON PORT SIDE MIDSHIPS AT ENGINE ROOM 1.5 FEET ABOVE WATERLINE. VSL IS NOT TO OPERATE UNTIL REPAIRS ARE COMPLETE AND AND A HOSE TEST OF REPAIRS ARE WITNESSED BY A MARINE INSPECTOR.
Construction/Loadline
Issued 17 February 1993
Resolved
REPAIR FLANGE AREA OF INSPECTION PLATE ON THE DECK LOCATED IN THE GALAXY ATTHE BASE OF THE LADDER TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_ _x001C_
Construction/Loadline
Issued 17 February 1993
Resolved
PROVIDE AND INSTALL PROPER THROUGH BULKHEAD FITTINGS OR JUNCTION BOXES, PORT AND STARBOARD, IN THE FORWARD STORAGE COMPARTMENT (LEADING INTO THE HEADS) FOR WIRES TO EMERGENCY LIGHTS IN THE HEADS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_
Electrical
Issued 17 February 1993
Resolved
PROVIDE PROPER BLANKS FOR ALL OPEN SPACES ON THE 12 VOLT (DC) PANEL LOCATEDIN THE ENGINE ROOM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Electrical
Issued 17 February 1993
Resolved
PROVIDE BLANKS FOR ALL OPEN SPACES ON 120 VAC ELECTRICAL PANEL LOCATED IN THE ACCESS TRUNK TO THE ENGINE ROOM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_ _x001C_
Electrical
Issued 17 February 1993
Resolved
PROVIDE AND INSTALL PROPER COVERS FOR FAN JUNCTION BOX ON THE PORT SIDE OF THE ENGINE ROOM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Electrical
Issued 19 February 1992
Resolved
REPAIR TWO PORT BATTERY BOXES SO THEY ARE LEAK PROOF ON THE BOTTOM.
Lifesaving
Issued 19 February 1992
Resolved
PROVIDE 36 ADULT LIFEJACKETS AND 0 CHILDRENS LIFEJACKETS. TOTAL PERSONS RESTRICTED TO 354 UNTIL CORRECTION OF THIS REQUIREMENT. TO BE COMPLETED TOTHE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Fire Fighting
Issued 19 February 1992
Resolved
PROVE PROPER SERVICING OF FIXED CHEMICAL EXTINGUISHER IN GALLEY HOOD WITHINPAST 12 MONTHS.
Electrical
Issued 19 February 1992
Resolved
SECURE LOOSE WIRING CONNECTORS FOR STBD FAN IN ENGINEROOM. WIRES ARE NUTTED AND TAPED AND NEED COVERING.
Electrical
Issued 22 February 1989
Resolved
PROPERLY SECURE ALL WIRING IN THE OVERHEAD AND ALONG THE OUTBOARD PORT SIDE BULKHEAD OF GALLEY.
Electrical
Issued 22 February 1989
Resolved
PROPERLY SECURE CONDUIT AND RECONNECT WIRING TO REEFER SYSTEM LOCATED ON THE STARBOARD SIDE OF GALLEY.
Navigation
Issued 22 February 1989
Resolved
PROVIDE CURRENT ISSUES OF COAST PILOT AND LOCAL CHART OF NEW YORK AREA.
Construction/Loadline
Issued 19 January 1989
Resolved
REMOVED DOUBLERS AND INSERTED A 3.5' X 4' X 3/8" PLATE IN WAY OF PORT EXHAUST, AT THE STERN.
Accommodation/Occupational Safety
Issued 19 January 1989
Resolved
CLEAN MUCK, FOOD, DIRT, AND ANY OTHER LITTER FROM BEHIND APPLIANCES ON THE PORT SIDE AND ALONG THE STAIRWELL.
Electrical
Issued 19 January 1989
Resolved
REMOVE DEAD END WIRES FROM BEHIND GALLEY APPLIANCES.
Construction/Loadline
Issued 19 January 1989
Resolved
IN THE ENGINE ROOM, ADJACENT TO THE ENGINES, ON THE PORT AND STARBOARD SIDES, RENEW THE PORTION OF THE VENTILATION DUCT THAT IS PARALLEL TO THE KEEL. DO NOT REINSTALL INSULATION UNTIL THE REPAIRS HAVE BEEN FOUND SATISFACTORY BY A USCG MARINE INSPECTOR.
Accommodation/Occupational Safety
Issued 26 May 1987
Resolved
SUBMIT PLAN FOR REVIEW FOR PROPER INSTALLATION OF DECORATIVE LIGHTS OR REMOVE PRESENTLY INSTALLED DECORATIVE LIGHTS.
Electrical
Issued 4 March 1987
Resolved
PROPERLY SECURE ELECTRICAL CABLE RUNS IN OVERHEADS WITH METAL CLIPS.
Electrical
Issued 3 January 1986
Resolved
REMOVE PLASTIC TIE WRAPS ON ELECTRICAL CABLES IN GALLEY, ENGINE ROOM AND WHEELHOUSE AND REPLACE WITH SUITABLE METAL TRAYS OR TIE WRAPS.
Lifesaving
Issued 3 January 1986
Resolved
6 RED AND 6 ORANGE HAND FLARES ARE OUTDATED.