CABANA is a 1973 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in January 2026, along with 56 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 21 January 2026.

Built
1973
Last inspected
21 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 January 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE7589
Flag
UNITED STATES
Maury page id
psix-47484

Documentation record

Registered dimensions (L × B × D)79.1 ft × 31.5 ft × 8.3 ft
Registered tonnagegross 98 / net 82
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWARREN, RI, UNITED STATES · built 1973
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
82 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

21 January 2026 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8299312
14 November 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8265088
31 August 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8221930
31 August 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8236801
14 April 2025 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8111172
28 February 2024 Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7867624
6 November 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7820689
30 May 2023 In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7700166
8 March 2023 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7647769
26 July 2021 Internal Structural Exam · Deficiency Check · Damage Survey · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7268708
18 December 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7112923
4 November 2020 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7089456
13 February 2020 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6910461
26 February 2019 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6633936
12 November 2018 Drydock Exam · Damage Survey · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6580450
3 April 2018 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6383914
30 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6297786
22 March 2017 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6109778
6 January 2017 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6066772
2 December 2016 Drydock Extension · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6057949
18 March 2016 Deficiency Check · Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5836056

Deficiency record · 56

03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 31 August 2025 Resolved
All passenger accommodations must be arranged and equipped to provide for the safety of the passengers in consideration of the route, modes of operation, and speed of the vessel. Due to marine casualty, vessel has damage to 02 windows midships starboard side (01 missing and 01 cracked) adjacent to gangway.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2025
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 April 2025 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MIs observed rotating machinery not protected by guards or rails on both the port and stbd service generators. Rectify deficiency within 7 days. 46 CFR 177.960
Action required: 705 - Other - as specified
Due 21 April 2025
Resolved 20 April 2025
Resolution: Vessel submitted photos showing the newly installed guards. See documents tab for photos.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 March 2024 Resolved
Fire main pipe has a hole IWO galley Ice Machine, must make proper repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2024
Resolution: New pipe fitted and PSI tested
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 March 2024 Resolved
Vessel has missing structural fire protection insulation in engine room, engine room trunk, and behind bar at the corner. Must fix to original and approved type.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2024
Resolution: New insulation fitted and paper work provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 March 2024 Resolved
Electrical distribution panel in galley, engine room, engine room trunk, and top deck locker need to be properly labeled with name plate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2024
Resolution: Panel's labeled.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 14 March 2024 Resolved
The public address system was not located throughout the vessel, zero on the second deck, and the speaker on the main deck was not working properly, must add enough speakers to cover entire vessel in all operating conditions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2024
Resolution: New speakers installed and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 March 2024 Resolved
Life jacket stowage on 2nd deck needs proper labeling.(number)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 March 2024 Resolved
Both gauges for lube oil & jacket water at the helm are glazed over and/or not working, must replace or repair as needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2024
Resolution: New gauges installed and tested.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 14 March 2024 Resolved
Vessel needs updated and current charts of operating area. (2018)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2024
Resolution: New charts on board
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 14 March 2024 Resolved
Port side main deck 2nd window is cracked causing a haz to passengers
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2024
Resolution: Window replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 March 2024 Resolved
Ring buoys need new retro and vessels name.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2024
Resolution: Retro installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 March 2024 Resolved
All scuttles on the main deck must be weathertight, have a retention line, and work properly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2024
Resolution: Scuttles have new gasket, painted/marked, and easy to operate.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 March 2024 Resolved
All rugs and carpets shall be of wool or other material having equivalent fire resistive qualities. (Flame spread rating 75 & smoke developing rating not to exceed 100; ASTM E701-84)
Action required: 705 - Other - as specified
Due 29 April 2024
Resolved 13 May 2024
Resolution: New carpet installed. Documents scanned into system.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 14 March 2024 Resolved
Vessel needs to update the General Arraignment and structural fire protection plans to reflect current arrangement, specifically taking into consideration space categorization, fire doors, fire loads, and means of escape.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 May 2024
Resolution: Vessel is now removing Galley items and will use space as storage, 2nd means of escape not required.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 28 February 2024 Resolved
(b) An abandon ship drill must be conducted as follows: (1) Each member of the crew shall participate in at least one abandon ship drill each month. Last documented abandon ship drill was in September 2023.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2024
Resolution: Drills completed and logged
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 28 February 2024 Resolved
(b) A fire drill must be conducted at least once each month. Last documented fire drill was in September 2023.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2024
Resolution: Fire drill completed and logged
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 28 February 2024 Resolved
(e) Each rescue boat required in accordance with § 117.210 of this subchapter must be launched with its assigned crew aboard and maneuvered in the water as if during the actual man overboard situation; (1) Once each month, if reasonable and practicable; but (2) At least once within a 3 month period before the vessel gets underway with passengers. Last documented Man Overboard drill was in September 2023.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2024
Resolution: Drill completed and logged
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 28 February 2024 Resolved
(a) Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels... Insufficient documentation onboard for three of four crew members enrollment in a DAP screening program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2024
Resolution: Audit conducted by IO shop and waiting on additional info, cleared def.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 28 February 2024 Resolved
(b) Qualifications. The Vessel Security Officer (VSO) must have general knowledge, through training or equivalent job experience, in the following: (1) Those items listed in § 104.210 (b)(1) and (b)(2) of this part; (2) Vessel layout; (3) The VSP and related procedures, including scenario-based response training; (4) Crowd management and control techniques; (5) Operations of security equipment and systems; (6) Testing and calibration of security equipment and systems, and their maintenance while at sea; and (7) TWIC. The Captain, the VSO by default, was unaware of positional responsibilities & the vessel's VSP.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2024
Resolution: Capt/VSO completed questioning by CGMI during additional inspections.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 February 2024 Resolved
...all vessels shall be provided with not less than two avenues of escape from all general areas accessible to the passengers or where the crew may be quartered or normally employed... The Galley's original aft means of escape has been permanently blocked by a dance floor over the exit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2024
Resolution: Def cleared but captured in new def issued, see activity.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 February 2024 Resolved
Vessels contracted for on or after July 1, 1961, which carry more than 150 passengers shall meet the requirements of subpart 72.05 of Subchapter H... Evaluated in accordance with 46 CFR 72.05 and the vessel's approved Structural Fire Protection (SFP) Plan, MI observed multiple missing fire doors at the top of stairwells or doors of an unapproved type.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2024
Resolution: Doors tested and complete.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 February 2024 Resolved
Rugs and carpet may be used in addition to deck coverings. Rugs and carpets must be constructed of 100 percent wool or equivalent as determined by the regulation, MI observed deck coverings main dk & upper deck not of an approved type.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2024
Resolution: Cleared for upper deck, new def issued for main deck.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 February 2024 Resolved
Furniture such as chairs, sofas, and similar items are tested and meet the requirements in UL 1056 “Fire Test of Upholstered Furniture,” or meet the requirements in § 72.05–55 in subchapter H of this chapter. MI doubts the fire resistance of furnishings observed on main deck and upper deck. Operator will provide proof that installed all furnishings are of an approved type and in accordance with the vessel's SFP Plan or regulation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2024
Resolution: Removed all furniture not meeting regs and placed metal tables and chairs on vessel. Provided drawing of placement.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 February 2024 Resolved
Ceilings, linings, and any furring incidental to their installation in control spaces, passageways, stairways, accommodation spaces and service spaces must be of noncombustible material in accordance with § 164.009 in subchapter Q of this chapter, or other standard specified by the Commandant. MI observed plastic decorative flowers. Operator will remove all decorations not of an approved type or accounted for in SFP Plan.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2024
Resolution: Removed from vessel
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 February 2024 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable, the vessel has some modifications Without documented MSC approval, MI notes the following modifications to the vessel not captured in the construction, general arrangement, and SFP plan drawings: 1)enclosure of upper deck with combustible materials 2)construction of security room and lifejacket locker with combustible materials
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2024
Resolution: Upper deck enclosure removed, life jacket closet now acceptable and security room in galley addressed in new def.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 February 2024 Resolved
Furniture such as chairs, sofas, and similar items are tested and meet the requirements in UL 1056 “Fire Test of Upholstered Furniture,” or meet the requirements in § 72.05–55 in subchapter H of this chapter. MI doubts the fire resistance of furnishings observed on main deck and upper deck. Operator will provide proof that installed all furnishings are of an approved type and in accordance with the vessel's SFP Plan or regulation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2024
Resolution: Tables and chairs on main deck are metal, drawing of locations provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2023 Resolved
"All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection." -Electrical outlets on main deck are not properly secured. -Electrical outlet on fwd port side, main deck has cracked face plate. -Light is missing bulb and cover in the stowage locker on main deck aft. -Junction box in the stowage locker on main deck aft is not properly secured to the wall. -Dead end wires found in the stowage locker on main deck aft. -Junction box found daisy chained to another Junction box in the stowage locker on main deck aft.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 July 2023
Resolution: photos of electrical installation submitted
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 May 2023 Resolved
"Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection." Extinguisher on main deck, midship does not have bracket for portable extinguisher
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 July 2023
Resolution: extinguisher installed in bracket
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 March 2023 Resolved
AUXILIARY MACHINERY SHALL BE SUITABLE IN TYPE AND DESIGN FOR THE PURPOSE INTENDED. POWER TAKE OFF PIPING FOUND WITH SOFT PATCH. REPLACE DISCHARGE PIPE AND PROVIDE PHOTOGRAPHIC EVIDENCE OR REPAIR. 46 CFR 182.10-1 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2023
Resolved 11 April 2023
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 26 July 2021 Resolved
THIS VESSEL IS A "TL-BOAT", THEREFORE NOT REQUIRED A SAFETY MANAGEMENT SYSTEM (SMS) PER REGULATION. SECTOR NY HAS FOUND THE FOLLOWING DEFICIENCIES TO BE OBJECTIVE EVIDENCE THAT A SERIOUS SUBSTANDARD CONDITION HAS NOT BEEN PRO-ACTIVELY MANAGED BY THE VESSEL'S OWNER/OPERATOR, LEADING TO A LACK OF SAFETY CULTURE ONBOARD THE VESSEL. 46 CFR 176.25-50
Action required: 30 - Ship detained
Resolved 31 December 2021
Resolution: Compelted all required defs and satisfactory sea trials
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 July 2021 Resolved
REPAIRS OR ALTERATIONS TO THE HULL, MACHINERY OR EQUIPMENT THAT AFFECT THE SAFETY OF THE VESSEL MUST NOT BE MADE WITHOUT THE APPROVAL OF THE COGNIZANT [name withheld] TO HAVE A HOLE IN ITS HULL UNDER THE WATERLINE IN THE PORT SIDE GALLEY BILGE SPACE. THE HOLE OCCURRED AS A RESULT FROM THE VESSEL'S CREW PERFORMING UNAUTHORIZED REPAIRS AND ALTERATIONS. VESSEL WILL BE DETAINED UNTIL THE FOLLOWING ARE ALL COMPLETED/APPROVED BY THE USCG: 1)24/7 BILGE WATER LEVEL WATCH UNTIL APPROVED TEMPORARY REPAIRS ARE MADE AND WATER INGRESS INTO GALLEY SPACE HAS BEEN SECURED. 2)SUBMIT A REPAIR PLAN FOR TEMPORARY PATCH FOR SAFE PASSAGE TO DRYDOCK YARD. 3)SUBMIT A TOW PLAN TO DESIRED DRYDOCK YARD. 4)VISITING MARINE INSPECTORS MUST VERIFY ALL APPROPRIATE TEMPORARY MEASURES ARE PUT IN PLACE PRIOR TO INITIATING TOW PLAN TO DRYDOCK YARD. 5)ONCE AT DRYDOCK YARD, VESSEL WILL BE REQUIRED TO COMPLETE ALL WORK LIST ITEMS IDENTIFIED FROM NOVEMBER 2020 DRYDOCK EXAM (MISLE #7089456) AND ANY ADDITIONAL ITEMS FROM SUBSEQUENT JULY 2021 DAMAGE SURVEY (MISLE #7268708). ALL REPAIRS AND ALTERATIONS TO DEFICIENT HULL AREAS MUST BE TO THE SATISFACTION OF THE CONGNIZANT OCMI. 46 CFR 115.700 46 CFR 116.300
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 31 December 2021
Resolution: Compelted all required defs and satisfactory sea trials
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 26 February 2019 Resolved
Make aft watertight bulkhead in galley watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2019
Resolved 14 March 2019
Resolution: Bulkhead was returned to wateright condition.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 February 2019 Resolved
Remove oil containers stored in accommodation space
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2019
Resolved 14 March 2019
Resolution: Oil was removed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 February 2019 Resolved
Label fire extinguishers
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2019
Resolved 14 March 2019
Resolution: Fire extinguishers lableled.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 February 2019 Resolved
If hazardous or combustible material is stored onboard it must be stored in an approved locker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2019
Resolved 14 March 2019
Resolution: Hazmat was removed from vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 February 2019 Resolved
Repair leaks on the port side generator
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2019
Resolved 14 March 2019
Resolution: Leaks repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2019 Resolved
Repair leaks on the port side main engine
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2019
Resolved 14 March 2019
Resolution: Leaks repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 February 2019 Resolved
Repair fuel filter leak
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2019
Resolved 14 March 2019
Resolution: Leaks repaired.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 26 February 2019 Resolved
Replace insulation in engine space
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2019
Resolved 14 March 2019
Resolution: New insulation installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 February 2019 Resolved
Replace cover on a/c unit in galley
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2019
Resolved 14 March 2019
Resolution: New cover installed on A/C unit
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 26 February 2019 Resolved
Refasten overhead light in galley
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2019
Resolved 14 March 2019
Resolution: Light refastened to ceiling.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 February 2019 Resolved
Ensure lights might UL standard
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2019
Resolved 14 March 2019
Resolution: UL approval for lights was identified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 February 2019 Resolved
Tighten all battery connections
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2019
Resolved 14 March 2019
Resolution: Battery connections were tight
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 3 April 2018 Resolved
Provide current company policy and enrolled crew members of the drug and alcohol program.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2018
Resolved 11 April 2018
Resolution: Verified updated company policy and enrolled crew members in DAPI program.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 3 April 2018 Resolved
Prove proper operation of depth sounder.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2018
Resolved 11 April 2018
Resolution: Verified proper operation of depth sounder.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 3 April 2018 Resolved
Over 10 amps of ground detected on shore side power. Correct ground and provide causal analysis.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2018
Resolved 11 April 2018
Resolution: Verified causal analysis; ground stemmed from shore power side. O/op contacted marina for proper action.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 3 April 2018 Resolved
Properly label engine room generator breaker panel opposite pilot house supply and 12 VDC current panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2018
Resolved 11 April 2018
Resolution: Verified proper labels on breaker panels.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 3 April 2018 Resolved
Label volt meter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2018
Resolved 11 April 2018
Resolution: Verified labeled voltmeter.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 April 2018 Resolved
Replace navigation lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2018
Resolved 11 April 2018
Resolution: Verified replaced nav lights.
Fire Fighting › Fire Main › Valves
Issued 22 March 2017 Resolved
Vessel must repair a leaking fire main valve. 46CFR176.25-25
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 30 March 2017
Resolution: Vessel repaired leaking valve.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 22 March 2017 Resolved
Vessel must replace all reflective material as discussed on most life jackets with new material. 46CFR180.25-25(a)
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 26 April 2017
Resolution: Vessel replaced worn reflective material.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 22 March 2017 Resolved
Vessel must install ground dectection on electrical distribution panel. 46CFR183.10-30 & 46CFR111.35-1(j)
Action required: 705 - Other - as specified
Due 20 February 2018
Resolved 3 April 2018
Resolution: Vessel installed ground detection system.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 March 2016 Resolved
Condemned 17 Kapok type life jackets. Replace with serviceable lifejackets. Vessel is not to operate with more than 320 pax until proper PFDs are installed.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 25 March 2016
Resolution: Received email from operator showing receipt of 27 lifejackets and pictures indicating that the lifejackets were installed on the vessel.
Electrical › Electrical Distribution System (service) › Cable
Issued 18 March 2016 Resolved
Permanently install CCTV in pilot house. Remove extension cords.
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 25 March 2016
Resolution: Received email containing pictures from operator indicating properly installed receptacle in pilot house.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 March 2016 Resolved
04 Unapproved Lights in accomodation space. Install UL listed lights.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 April 2016
Resolved 13 April 2016
Resolution: Vsl removed unapproved light fixture
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 March 2016 Resolved
Floatlight broken and equipped with incorrect battery.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 18 March 2016
Resolution: Installed UL approved float light with proper battery