MAURY USCG vessel records Sign in
← All vessels

TUO FU 3

TUO FU 3 is a 1993 freight ship. The Coast Guard has recorded 37 inspections since 1998, most recently in February 2011, along with 20 deficiencies and 11 operational controls.

Records from 1998 to 2011. Most recent: operational control imposed, 23 February 2011.

Built
1993
Last inspected
23 February 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9013414 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
474883
Flag
PANAMA
—
Maury page id
psix-474883

Inspections, by type

…with no type recorded21
Years with a record 10 calendar years (1998–2011)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it63919 - Dead Weight, Ton
79797 - Displacement, Ton
39666 - Convention (Subpart B), Gross Ton
20042 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

B. NO. 275 Tank Barge · MISLE 53428 · 15 June 1999 · activity 534003

Inspection history · 37

23 February 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3950674
15 November 2010 Ballast Water Examination · ISPS II Exam · PI Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3886646
15 November 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3891375
15 November 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3893125
11 February 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2583550
28 January 2006 ILO-147 Exam · COC-TVE Renew · MARPOL Annex I Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2575750
27 January 2006 ISPS I Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2574598
27 January 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2575178
23 January 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2571362
10 April 2005 Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2331511
8 April 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2329760
12 March 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2316288
21 January 2005 COC-TVE Annual · ISPS II Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2280554
19 January 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2281280
5 October 2004 ISPS II Exam
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2210236
24 August 2004 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2175290
26 January 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1993166
22 January 2004 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1990707
20 January 2004 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1988249
9 January 2004 Ballast Water Examination · MARPOL Annex I Examination · Certificate of Compliance
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1975934
9 January 2004 Security Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1985090
9 January 2004 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1986216
14 September 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1905086
24 May 2003 Ballast Water Examination · Annual Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1801030
22 May 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1799481
29 January 2002 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1482200
14 January 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1480989
13 January 2002 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1479055
10 January 2002 Tank Vessel Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1475610
28 January 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 210133
28 January 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 274142
28 January 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 771255
15 June 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 534003
7 March 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 426125
7 December 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 423614
8 June 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 416735
8 June 1998 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1431970

Deficiency record · 20

Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 15 November 2010 Resolved
1410-Propulsion main engine- The machinery, boiler and other pressure vessels associated piping systems shall be constructed of adequate design for intended service. It was reported that the #5 cylinder relief valve on the main diesel engine vibrated loose while underway. SOLAS 74am II-1/26.
Action required: 705 - Other - as specified
Due 15 November 2010
Resolved 16 November 2010
Resolution: Received, reviewed and accepted Class Report from RINA attesting to permanent repairs.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 15 November 2010 Resolved
0610-lifeboats- All life-saving appliances shall be in working order and ready for immediate use. It was observed that the port lifeboat starter has failed. SOLAS 74am. III/20
Action required: 705 - Other - as specified
Due 22 November 2010
Resolved 16 November 2010
Resolution: Received, reviewed and accepted Class report from RINA attesting to the repair of the life boat.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 November 2010 Resolved
2110-Oily mixtures machinery- There is clear grounds for believing that the master or crew are not familiar with essential shipboard procedures. The crew could not demonstrate the ability to recover data from 107 content data logger. Operations manual for the OCM could not be provided. Also, entries in the ORB were inconsistent with what the PSCO recovered from the OCM. MARPOL 73/78 Annex I/11.
Action required: 705 - Other - as specified
Due 22 November 2010
Resolved 16 November 2010
Resolution: Received, reviewed and accepted Class report from RINA attesting to the outstanding requirements being rectified.
Engineering › Generator (propulsion-electric) › Remote Control Circutry
Issued 15 November 2010 Resolved
1410- Propulsion main engine- In general, automatic starting, operational and control systems shall include provisions for manually overriding the automatic controls. It was observed that the remote shut down on the #3 diesel generator has failed and been removed from service. SOLAS 74am II-1/31.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 November 2010
Resolution: Received, reviewed and accepted Class report from RINA attesting to the repair to the remote shutdown.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 15 November 2010 Resolved
2199- Other (MARPOL)- It was observed by the PSCO that the crew has installed a non class approved temporary hose to move sewage from the deck fitting to the aft peak ballast tank. SOLAS 74am. I/11
Action required: 705 - Other - as specified
Due 22 November 2010
Resolved 16 November 2010
Resolution: Received, reviewed and accepted Class report from RINA attesting to the discharging and cleaning of aft peak ballast tank.
Electrical
Issued 9 January 2004 Resolved
Renew as orignial motor controller box cover in fwd line locker.
Due 9 February 2004
Resolved 9 January 2004
Deck/Cargo › Holds/Tanks
Issued 9 January 2004 Resolved
Clean screens on aux water filled P/V Breaker and mast riser. to satisfaction of class. LEGACY COMPONENT DESC: Valve, Pressure Vacuum Relief
Action required: 15 - Rectify deficiencies by next port
Resolved 9 January 2004
Deck/Cargo › Ballast › Dedicated Clean Ballast Tanks
Issued 9 January 2004 Resolved
relocate crane block in vicinity of port crane to correct fleet angle ( Wire rope is rubbing on pulley bracket). To be correct at next dry dock. Crane not to be used in us waters
Due 1 September 2005
Resolved 24 August 2004
Lifesaving › Launching Appliances
Issued 9 January 2004 Resolved
Free frozen port lifeboat falls pulley. To satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 January 2004
Navigation › Emergency Steering
Issued 9 January 2004 Resolved
Freshen steering gear instructions and diagram. to satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 January 2004
Deck/Cargo › Inert Gas System
Issued 9 January 2004 Resolved
Prior to departure from St. Croix prove proper operation of primary inert gas system.
Action required: 705 - Other - as specified
Resolved 9 January 2004
Deck/Cargo › Inert Gas System
Issued 9 January 2004 Resolved
Prior to next U.S. port proper operation of secondary inert gas system. To satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 January 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 9 January 2004 Resolved
Prior to its use in U.S. Waters demonstrate suitability of fwd bunker pipe. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Resolved 26 January 2004
Resolution: Received a Fax of the Bunker Line Hydrostatic Test Report where the Bunker Line results were found Satisfactory.
Accommodation/Occupational Safety › Occupational Safety
Issued 9 January 2004 Resolved
Properly label emergency exit.
Action required: 705 - Other - as specified
Due 9 February 2004
Resolved 9 January 2004
Engineering › Steering Gear System
Issued 10 January 2002 Resolved
Nut from bolt connecting feedback unit linkage was missing, replaced by engineers. LEGACY COMPONENT DESC: Feedback Unit
Condition: Unknown
Due 10 January 2002
Resolved 10 January 2002
Construction/Loadline
Issued 28 January 2000 Resolved
Possible ballast tank/piping fracture IWO #6 P/S ballast tanks. Provide satisfactory report from Certificate Issuing Authority as to cause/repair/test of system IAW SOLAS 74 I/11, prior to ballast operations in U.S. Waters.
Condition: Unknown
Due 5 February 2000
Resolved 24 May 2003
Resolution: Cleared during Port State Control inspection.
Accommodation/Occupational Safety
Issued 7 December 1998 Resolved
Repair the toilet in the hospital space.
Condition: Unknown
Due 8 December 1998
Resolved 14 December 1998
Fire Fighting
Issued 7 December 1998 Resolved
Update all Fire Control Plans to reflect current position of the firefighting equipment prior to 07Jan99 (SOLAS 74a Reg II-2/20.1).
Condition: Unknown
Due 9 March 1999
Resolved 9 March 1999
Lifesaving
Issued 7 December 1998 Resolved
Unfasten liferafts from the deck to allow float-free arrangement.
Condition: Unknown
Due 7 January 1999
Resolved 14 December 1998
Fire Fighting
Issued 7 December 1998 Resolved
Provide four working breathing devices for the firemans outfits.
Condition: Unknown
Due 7 January 1999
Resolved 14 December 1998

Ownership record