Records from 2012 to 2026. Most recent: inspection, 18 June 2026.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 June 2026
Resolved
Alcohol testing must be conducted on each individual engaged or employed on board the vessel who is directly involved in an incident within 2 hours. Vessel is missing alcohol test strips. Provide test strips onboard the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2026
Resolved 23 July 2026
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 June 2026
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts. Vessel did not have current charts, provide current charts on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2026
Resolved 21 July 2026
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 June 2026
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Items in first aid kit are expired. Provide new unexpired items.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2026
Resolved 30 June 2026
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 June 2026
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date U.S. Coast Pilot or similar publication. Provide up to date Eldridge book.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2026
Resolved 30 June 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 June 2026
Resolved
A vessel must be provided with bilge pumps in accordance with 46 CFR Table 182.520(a). The manual switch to activate the #2 bilge pump is not operable. Repair to the satisfaction of the attending USCG MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2026
Resolved 13 July 2026
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 June 2026
Resolved
A pre-engineered fixed gas fire extinguishing system must have a means to reset devices used to automatically shut down engines. The overide switch for the port main engine is not functioning. Repair to the satisfaction of the attending USCG MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2026
Resolved 30 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 June 2026
Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke distress
signals. Hand red flares may be substituted for orange smoke signals. Vessel is missing required number of orange smoke signals. Provide adequate number of distress signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2026
Resolved 30 June 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 October 2024
Resolved
1 adult lifejacket was no longer serviceable. Passenger count reduced by 1 till lifejacket is replaced.
Action required: 10 - Deficiency Rectified
Resolved 10 October 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 October 2024
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. 6 adult life jackets need retroreflective tape replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024
Resolved 22 October 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 October 2024
Resolved
Adult and children's life jackets were not properly separated. Properly stow life jackets to ensure adult and children's life jackets are easily identifiable.
Action required: 10 - Deficiency Rectified
Resolved 10 October 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 October 2024
Resolved
Stowage of adult and children's life jackets was not properly marked.
Action required: 10 - Deficiency Rectified
Resolved 10 October 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 October 2024
Resolved
Stern light inoperable. Vessel restricted to daylight ops only.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024
Resolved 13 October 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 10 October 2024
Resolved
FCC Radiosafety Telephony Certs were expired. Renew.
47 CFR 80
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024
Resolved 15 November 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 October 2024
Resolved
Old wire run hole in fwd stbd void needs to be sealed
Action required: 10 - Deficiency Rectified
Resolved 10 October 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 October 2024
Resolved
Wire run box needs to be secured in port chain locker
Action required: 10 - Deficiency Rectified
Resolved 10 October 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 October 2024
Resolved
3 dead end wires in stbd life jacket space need to be removed/properly secured
Action required: 10 - Deficiency Rectified
Resolved 10 October 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 October 2024
Resolved
High water alarm in port middle space inoperable.
Action required: 10 - Deficiency Rectified
Resolved 10 October 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 October 2023
Resolved
Properly wire, remove breaker, from light in stbd side tool space.
Action required: 705 - Other - as specified
Resolved 19 October 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 October 2023
Resolved
Remove or properly cap off loose wiring in stbd aft bulkhead of engine space. Seal holes around wires.
Action required: 705 - Other - as specified
Resolved 16 October 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 October 2023
Resolved
Grind down to bare metal and remove cleat on main mast where prior mast repair was welded with existing mast.
Action required: 705 - Other - as specified
Resolved 13 November 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 March 2023
Resolved
Port quarter space bilge high level alarm is inoperable. Repair/replace visual and audible alarm. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2023
Resolved 7 March 2023
Resolution: Float switch replaced and alarms operate SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 March 2023
Resolved
Vessel has 8 orange and 4 red distress signals. Provide 2 additional red distress signals. 46 CFR 180.68
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2023
Resolved 7 March 2023
Resolution: Distress signals SAT.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 26 October 2022
Resolved
Mid body bilge alarm light does not illuminate when energized.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2022
Resolved 29 November 2022
Resolution: Received video
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 October 2022
Resolved
Emergency Egress not labeled IAW 46 cfr 185.606
Action required: 705 - Other - as specified
Due 30 November 2022
Resolved 29 November 2022
Resolution: Received photos
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 September 2021
Resolved
4. Repair plan approval – not requested or authorized by OCMI
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 September 2021
Resolved
Hauled out for repairs (Maine) – did not request permission from OCMI who issued COI
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 March 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 December 2020
Resolved
1 adult life jacket non-serviceable. Total person allowed reduced to 41. 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 15 December 2020
Resolution: Life jacket replaced.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 10 December 2020
Resolved
EPIRB battery expired. Route reduced to no more than 3 miles from shore. 46 CFR 185.728
Action required: 705 - Other - as specified
Resolved 15 December 2020
Resolution: EPIRB replaced.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 9 December 2020
Resolved
EPIRB hydrostatic release expired. Route restricted to no more than 3 miles from shore. 46 CFR 185.740
Action required: 705 - Other - as specified
Resolved 15 December 2020
Resolution: New EPIRB assembly with new HRU installed.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 9 December 2020
Resolved
Alcohol test kits expired. 46 CFR 16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2020
Resolved 15 December 2020
Resolution: Current kits onboard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 November 2019
Resolved
Main Mast steaming light inoperative. Replace/repair light prior to operations. 46 CFR 183.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2019
Resolution: Light replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 November 2019
Resolved
Gooseneck bushings worn (identified by third party rigging survey). Replace bushings at upcoming dry-dock availablity in June. 46 CFR 177.330
Action required: 705 - Other - as specified
Resolved 9 December 2020
Resolution: Bushings replaced.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 27 November 2019
Resolved
Crack in small boat platform frame stbd mount to be repaired at dry-dock availability in June. Special note added.
Action required: 705 - Other - as specified
Resolved 9 December 2020
Resolution: Crack in frame mount repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 14 November 2019
Resolved
Vessel rep unable to provide EAP policy, hotline number or proof of training.
46 CFR 16
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2019
Resolution: Information provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 November 2019
Resolved
Bilge high level alarms not labeled. Provide a label for each alarm specifying the space it is alarming for. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2019
Resolved 19 November 2019
Resolution: Alarms labeled.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 November 2019
Resolved
Install metal flame shield for fuel generator fuel filter.
46 CFR 182.410
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2019
Resolution: New filter housing with flame shield installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 October 2019
Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with manufacturer's instructions. The manual pull station on the Fireboy system, in the port and stbd "engine room", was not to manufacturer spec. Also head on the bottle was not manufacturer approved. Prior to the carriage of passengers must have fully manufacturer approved Fireboy system onboard.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 November 2019
Resolution: Approved systems installed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 October 2019
Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke distress signals. Flares onboard vessel were expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 November 2019
Resolution: Distress signals current.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 October 2019
Resolved
Stations in the maritime service must be licenses by the FCC. Ship's station license had expired on October 20, 2019. Vessel Restricted to 1000 feet from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 November 2019
Resolution: Station License provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 October 2019
Resolved
Construction and arrangement of a vessel must allow the safe operation of the vessel. Vessel's boom has various cracks through out it. Submit third party rig surveyor inspection report to USCG.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 27 November 2019
Resolution: Survey conducted; cracks do not cause safety issue.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 October 2019
Resolved
Construction and arrangement of a vessel must allow the safe operation of the vessel. Aft platform where lifesaving appliances are mounted has a broken crossmember.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2019
Resolved 27 November 2019
Resolution: Defered to activity # 6849409
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 October 2019
Resolved
The construction and arrangement of the vessel must allow for the safe operation of the vessel. On the railing of the FWD stbd stanchion there is a bolt missing and on the port side aft railing, it is cracked with a bolt broken.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2019
Resolved 14 November 2019
Resolution: Repairs made.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 October 2019
Resolved
Navigation lights should be visible in all weather. Vessel's port side navigation light has paint over the cover and is cracked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2019
Resolved 14 November 2019
Resolution: Nav lights SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 June 2019
Resolved
Sail mizzen mast goose neck worn, miss aligned.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2019
Resolved 27 June 2019
Resolution: Flipped goose neck block over and inspected bolt assembly, added wear washer, all sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 June 2019
Resolved
High bilge water alarm in stbd space visual warning light out.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2019
Resolved 27 June 2019
Resolution: New led installed in system, test sat.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 21 November 2018
Resolved
Provide MIS report or proof of submission. 46 CFR 16.500
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2018
Resolved 15 February 2019
Resolution: MIS will be provided for 2018.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 21 November 2018
Resolved
Provide proof of Employee Assistance Program training and display hotline number and company policy. 46 CFR 16.401
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2018
Resolved 15 February 2019
Resolution: Training completed.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 21 November 2018
Resolved
Provide alcohol test strips. 46 CFR 4.06
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2018
Resolved 15 February 2019
Resolution: Test strips provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 November 2018
Resolved
Provide chart of local area of operation. 46 CFR 184.420
Action required: 705 - Other - as specified
Due 28 November 2018
Resolved 15 February 2019
Resolution: Local chart provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 November 2018
Resolved
Secure battery cables to terminals with permanent type connectors. 46 CFR 183.350
Action required: 705 - Other - as specified
Due 28 November 2018
Resolved 15 February 2019
Resolution: Cables to terminals secured SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 September 2018
Resolved
Vessels IBA is expired and due for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 October 2018
Resolution: IBA properly inspected.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 25 September 2018
Resolved
Replace expired EPIRB Hydro Release
Due 9 October 2018
Resolved 15 October 2018
Resolution: New hydro release installed on EPIRB.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 September 2018
Resolved
Replace missing PFD in stern box.
Due 9 October 2018
Resolved 15 October 2018
Resolution: Missing PFD not required. Number on container changed to reflect proper amount.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 September 2018
Resolved
Secure line around body of life rings.
Due 9 October 2018
Resolved 15 October 2018
Resolution: Line properly spliced around body of ring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 September 2018
Resolved
Provide vessels name to life ring.
Due 9 October 2018
Resolved 15 October 2018
Resolution: Vessel name added to lifering.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 September 2018
Resolved
Vessel must provide drug and alcohol testing letter/roster.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 October 2018
Resolution: Roster provided from consortium.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 September 2018
Resolved
Vessel must provide approved sail plan as outlined on the COI.
Due 9 October 2018
Resolved 11 October 2018
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 25 September 2018
Resolved
Vessel must provide up to date nav pubs.
Due 9 October 2018
Resolved 15 October 2018
Resolution: Proper nav pubs on board.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 September 2018
Resolved
Add chaffing gear or reallign to stop wear on the forward stay starboard side.
Due 9 October 2018
Resolved 15 October 2018
Resolution: Owner shaped the aluminum support to avoid chafing on stay.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 September 2018
Resolved
Fix port engine stop solenoid.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 October 2018
Resolution: Solenoid replaced. Performed testing with fireboy to ensure proper shutdown and override. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 September 2018
Resolved
Replace flame bowls and plugs to stbd fuel filters.
Due 9 October 2018
Resolved 15 October 2018
Resolution: Proper flame bowls installed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 September 2018
Resolved
Fix auto pilot ram mount to the rudder.
Due 9 October 2018
Resolved 15 October 2018
Resolution: Ram mount was rebuilt. Performed steering test. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 September 2018
Resolved
Add double cmaps to the generator raw water and exhaust lines.
Due 9 October 2018
Resolved 15 October 2018
Resolution: After further inspection, it was determined there was not enough room on engine fixtures to accomodate double clamps.
Sail Rigging › Mast Step › Base
Issued 12 April 2018
Resolved
Provide a repair proposal for cracked main mast to MSC.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2018
Resolution: O/O provide drawings and calcs. to MSC, MI attended for vearification, cleared outstanding def.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 21 June 2017
Resolved
Provide valid FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 6 July 2017
Resolution: Rec'd updated FCC Safety Radio
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 21 June 2017
Resolved
Provide proof of MIS submission for 2016.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 23 June 2017
Resolution: Provided.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 21 June 2017
Resolved
Provide copy of last Random drug testing results.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 23 June 2017
Resolution: Provided last random tests for Shannon and Cameron.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 21 June 2017
Resolved
Provide arrangements for post casualty alcohol testing.
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 23 June 2017
Resolution: Provided alcohol test strips.
Sail Rigging › Running Rigging › Halyards
Issued 16 December 2016
Resolved
All rigging is to be replaced over the next 3years. Provide a plan to replace rigging. Act. 6010323
Action required: 705 - Other - as specified
Due 16 January 2017
Resolved 20 December 2016
Resolution: provided proposal to replace rigging over the next 3 years
Sail Rigging › Spars › Boom and Gooseneck Fitting
Issued 27 September 2016
Resolved
Repair cracked weld on main boom at gooseneck (replace eyes). IAW manuf guidelines. May not use main sail when carrying passengers.
Action required: 705 - Other - as specified
Due 27 September 2016
Resolved 14 October 2016
Resolution: Liberty weld performed removal and placement of new eyes in way of gooseneck. Welds were NDT'd with Dye Pen test satisfactory.
Sail Rigging › Stays/Shrouds › Wires
Issued 27 September 2016
Resolved
Provide thimble for topping lift connection at main and mizzen booms. (w/out the thimble the wire is bent and breaking).
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 19 October 2016
Resolution: Thimbles have been placed in topping lift application.
Sail Rigging › Catamaran › Crossbeam
Issued 27 September 2016
Resolved
Address forward crossbeam cracking w/builder (around anchor and at the hulls, keep USCG informed)
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 25 October 2016
Resolution: repaired with builders specs for FRP build up
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 27 September 2016
Resolved
Provide copy of last employee random drug testing.
Action required: 705 - Other - as specified
Due 27 October 2016
Resolved 11 October 2016
Resolution: Rec'd copy of last employee random tests.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 27 September 2016
Resolved
Provide Preventative Maintenance Plan (PMP) for sail rigging.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 20 December 2016
Resolution: provided draft for review and finalization