Records from 2016 to 2026. Most recent: inspection, 5 February 2026.
Inspection history · 17
5 February 2026
Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8304984
17 June 2025
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8161077
8 July 2024
Administrative Inspection · Annual Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7952861
3 January 2024
Hull Examination · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7844442
11 July 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7738918
6 July 2022
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7488665
18 January 2022
Internal Structural Exam · Deficiency Check · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7380584
17 August 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7289207
6 October 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7072352
2 April 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6936210
24 February 2020
Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6913139
10 October 2019
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6832902
9 October 2018
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6557866
1 March 2018
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6363713
27 June 2017
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6188589
31 May 2016
Plan Review "T" Boat · Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5887976
11 February 2016
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5813961
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2024
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection... The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. Marine inspector observed fuel supply lines for port and starboard fuel tanks do not have shut off valves capable of operation outside the space, at the tank connection. 46 CFR 182.455(b)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2024
Resolved 15 November 2024
Resolution: Verified port and starboard fuel tanks shut off valves operational.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 July 2024
Resolved
The lights prescribed in these Rules (Subpart C) shall have an intensity as specified in Annex I to these Rules (33 CFR part 84), so as to be visible at the following minimum ranges: In a vessel of 12 meters or more in length but less than 50 meters in length...A sidelight, 2 miles; and A white, red, green or yellow all-round light, 2 miles. Starboard side light is obstructed by horn and does not meet minimum visibility requirements. Additionally all around light wiring is damaged and light is inoperable. 33 CFR 83.22(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2024
Resolved 23 July 2024
Resolution: Received photographs showing proper operation of anchor light and side light visibility.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 8 July 2024
Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. HRU for EPIRB is expired. 46 CFR 176.808(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2024
Resolved 23 July 2024
Resolution: Received photograph of newly installed and marked HRU.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 8 July 2024
Resolved
The equipment required for lifefloats and buoyant apparatus must meet the following specifications: Paddle. Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant. Paddles provided for lifefloats are not lashed to the float. 46 CFR 180.175(f)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2024
Resolved 15 November 2024
Resolution: Paddles verified lashed to life float
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 8 July 2024
Resolved
The equipment required for lifefloats and buoyant apparatus must meet the following specifications: Light. The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. Lines attaching light to lifefloat are deteriorating in the sun. 46 CFR 180.175(f)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2024
Resolved 23 July 2024
Resolution: Received photographs of new line installed for waterlights.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 July 2024
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. MI observed fire buckets onboard missing complete required marking. 46 CFR 181.610
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2024
Resolved 25 November 2024
Resolution: Witnessed "fire bucket" stencilling
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 July 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. MI observed expired ammonia inhalants in approved first aid kit. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 July 2024
Resolved 8 July 2024
Resolution: Operator provided proof of purchase for new inhalants.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 July 2023
Resolved
A pre-engineered fixed gas fire extinguishing system must: (3) Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space; and
(4) Be installed in accordance with the manufacturer's instructions. Pre-engineered fire extinguishing system in genertor space allows Gen to be started in charged position. Vessels pre-engineered system requires servicing to ensure generator unable to start unless system overide is selected.
46 CFR 181.420 (a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2023
Resolved 19 July 2023
Resolution: Operator provided satisfactory report of servicing and operational test of shutdowns for generator.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 11 July 2023
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF–DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). VHF Radio missing GPS + MMSI number. Verify input of MMSI number into VHF radio and link GPS to VHF to allow DSC feature to be operational.
46 CFR 184.502
47 CFR 80.905 (a) (1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2023
Resolved 2 August 2023
Resolution: Provided photo of correct MMSI number plus GPS Coordinates loaded into VHF Radio. Photo attached to documents tab.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 July 2022
Resolved
Fuel shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The fuel shutoff valve does not stop the supply of fuel to the generator.
46 CFR 182.455(b)
Action required: 705 - Other - as specified
Resolved 12 July 2022
Resolution: Vessel owner sent in photos showing the re-arranged configuration for engine shutoff valve.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 July 2022
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The vessel's station license has expired last year and the vessel's Safety Radiotelephony Certificate will expire tomorrow. 46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 30 August 2022
Resolution: Vessel received both FCC certificates.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 August 2021
Resolved
A pre-engineered fixed gas fire extinguishing system must: (3) Automatically shut down all engines that draw intake air from within the protected space. The generator compartment fireboy system and the main propulsion engine compartment fireboy system share the same automatic shutdown/override switch and circuitry. Install the automatic shutdown/override switch for independent operation of each fireboy system to ensure activation of one fireboy does not render the internal combustion engine in the other space inoperable.
46 CFR 181.420(a)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 17 September 2021
Resolution: Verified operation to the satisfaction of the attending Marine Inspectors.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 17 August 2021
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. The vessel did not have a readily available means of closing the engine compartment ventilation. Demonstrate proper means of closure for the engine compartment supply ventilation.
46 CFR 182.460(j)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 20 August 2021
Resolution: Operator provided photographs of cloth covers for the engine room supply ventilation to the satisfaction of the Marine Inspector.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 August 2021
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned space. The aft compartment visual alarm was inoperable. Repair the visual indicator.
46 CFR 182.530(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 1 September 2021
Resolution: Operator provided video of operational visual and audible alarm for aft compartment bilge high water level.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 August 2021
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The aft automatic bilge pump visual indicator is inoperable. Repair the visual indicator.
46 CFR 182.530(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2021
Resolved 1 September 2021
Resolution: Operator provided photograph of visual indicator when aft bilge pump is operating automatically.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 August 2021
Resolved
Sailing vessels shall have rails or equivalent protection as considered necessary by the Officer in charge, Marine Inspection. The vessel does not have four inch courses, and operates as an "excursion" vessel. Provide four inch courses or an equivalent level of safety to the satisfaction of the OCMI prior to next credit dry dock.
46 CFR 177.35-1(h)
"Old T"
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 18 January 2022
Resolution: Course heights were corrected to meet excursion vessel requirements
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 6 October 2020
Resolved
Survival Craft. Life Floats must meet the standard under approval series 46 CFR 160.027-2(a) (which points to 46 CFR 160.10). Lifeline missing on aft float and neither of the two 18 person floats had pennants affixed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2020
Resolved 24 November 2020
Resolution: Photos received of corrected pendants and grab lines.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 6 October 2020
Resolved
Emergency broadcast placard required next to all radio installations and specific to the individual vessel. Broadcast placard missing vessel callsign.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2020
Resolved 2 November 2020
Resolution: Operator provided email with broadcast placard next to radio.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 10 October 2019
Resolved
All cable and wire must: Be installed with metal supports spaced not more than 24 inches apart, in such a manner as to avoid chafing and other damage. Wires throughout the vessel not properly supported. Install metal supports in accordance with the requirements.
46 CFR 183.340(b)(4)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2019
Resolved 13 December 2019
Resolution: Received email/photos from owner with supports in place.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 October 2018
Resolved
The pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturer's instructions.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2018
Resolved 10 October 2018
04 - Emergency Systems › N/A - No Subsystem › Damage control plan
Issued 9 October 2018
Resolved
Emergency procedures needs to be updated to included using a space blanket to plug up the wire runs exiting the Lazerett to make the space vapor tight.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2018
Resolved 10 October 2019
Resolution: Verified emergency procedures properly updated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 October 2018
Resolved
The Bilge pumps must be listed by an independent laboratory as meeting the requirements in UL 1113.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2018
Resolved 27 July 2020
Resolution: Received videos of required installation and operation for new bilge pumps in the mid hold and lazarette spaces.
Sail Rigging › Deck Hardware › Shackles
Issued 5 March 2018
Resolved
Provide preventative maintenance plan (PMP) for sail rigging IAW NVIC 2-16. 46CFR176.802
Due 5 April 2018
Resolved 10 July 2018
Resolution: Verified Sail PMP.
Stability › Weathertight Integrity › General
Issued 1 March 2018
Resolved
Forepeak and Lazarette Hatches are missing securing devices. 46CFR179.360 (b)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 10 April 2018
Resolution: Latching Devices were added to the hatches.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 1 March 2018
Resolved
Metallic Piping at transom is corroded and leaking. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 10 April 2018
Resolution: Exhaust Piping at transom was replaced.
Stability › Unintentional Flooding › General
Issued 1 March 2018
Resolved
Sea Water Valve for Main Engine is located within an enclosure that is scewed shut and not accessible without removing screws from an access panel. Owner required to install a means to make valve accessible from outside of the space. 46 CFR 179.350
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 April 2018
Resolved 10 April 2018
Resolution: Deck Access was installed to make salt water valve accessible.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 10 July 2017
Resolved
Provide complete Drug and Alcohol program/ complete DAPI audit 46 CFR 16.401
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2017
Resolved 21 July 2017
Resolution: Completed DAPI audit, company in process of hiring last crewmember
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 10 July 2017
Resolved
Provide cover over steering rope pass through near helm to close space off from fire pass thru. 46 CFR 181.410
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 July 2017
Resolved 21 July 2017
Resolution: Due to the odd shape and rigging running thru pass through a designated fire blanket is located next to the helm to close the space off as far as practicle from fire.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 July 2017
Resolved
Label/ remove dead end wiring from electrical panels. 46 CFR 183.340
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2017
Resolved 3 August 2017
Resolution: All dead end wiring removed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 July 2017
Resolved
Replace expired ammonia inhalants 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2017
Resolved 14 July 2017
Resolution: replaced expired tablets.
Sail Rigging › Deck Hardware › Shackles
Issued 10 July 2017
Resolved
Provide proper pin at shackle on main sheet 46 CFR 177.330
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2017
Resolved 21 July 2017
Resolution: Installed correct Pin at shackle.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 July 2017
Resolved
Remove household lighting plugged in under benches 46 CFR 183.340
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 July 2017
Resolved 3 August 2017
Resolution: Household lighting removed.
Construction/Loadline › Hull › Bottom Plating
Issued 27 June 2017
Resolved
Clean bilge hull under non-integral water tanks for inspection 46 CFR 176.802
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2017
Resolved 21 July 2017
Resolution: Cleaned and treated bilge under water tanks; inspected all sat