Inspection history · 29
8 January 2026
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8272378
11 March 2025
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8064796
16 May 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7871136
24 March 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7886663
17 January 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7833299
13 October 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7792286
12 October 2023
In-Service Inspection · Special Consideration · Appeal
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7826950
5 April 2023
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7627726
5 April 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7654649
17 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7652755
29 December 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7614243
22 November 2022
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7596378
13 June 2022
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7444811
20 April 2022
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7426529
1 February 2022
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7389304
17 November 2021
In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7353306
15 September 2021
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7312923
10 September 2021
Plan Review "T" Boat · Simplified Stability Test
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7309557
3 May 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7188148
16 March 2020
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6924264
31 January 2020
Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6900447
17 October 2019
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6833057
28 May 2019
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6685051
5 July 2018
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6501764
14 June 2018
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6388016
10 January 2018
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6333252
1 June 2017
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6147035
5 April 2016
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5845632
5 January 2016
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5790892
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 May 2024
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. A. 40-B:C fire extinguisher located under the ladder to the wheel house found to be unserviceable. Service or replace extinguisher to meet minimum requirements as indicated on the COI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 May 2024
Resolution: New fire extinguisher installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 5 April 2023
Resolved
Each vessel must meet the applicable requirements in Subchapter S of this chapter. MI found two hatch coveres with out securing devices.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2023
Resolved 6 April 2023
Resolution: All sat. Recieved pictures.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 22 November 2022
Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion resistant clip. No clip was on the light.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2022
Resolved 6 April 2023
Resolution: All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 22 November 2022
Resolved
The floating waterlight must be attached around the body of the life float. 2 of 2 floating waterlights tied to inside grab line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2022
Resolved 6 April 2023
Resolution: All Sat.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 22 November 2022
Resolved
The owner or operator shall be prepared to test steering system and make available for inspection to determine to the extent necessary to prove proper operation. Hydraulic ram to jockey bar bolt loost at jockey bar mount. (defer to January 2023 drydock)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2023
Resolved 6 April 2023
Resolution: All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 June 2022
Resolved
At least one ring life buoy must be fitted with a lifeline. MI found life buoy with no life line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2022
Resolved 27 June 2022
Resolution: Line Installed. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 June 2022
Resolved
Each floating watertight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. MI found floating light with not corrosion-resistant clip.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2022
Resolved 27 June 2022
Resolution: Corrosion-resistant clip installed. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 13 June 2022
Resolved
ach paddle must be lashed to the life float to which it belongs. MI found life float paddle not lashed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2022
Resolved 27 June 2022
Resolution: Paddle lashed. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 13 June 2022
Resolved
he name of the vessel must be marked or painted in clearly legible letters on each life float paddle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2022
Resolved 27 June 2022
Resolution: Letter stenciled. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 June 2022
Resolved
ach vessel must meet the applicable requirements in Sub chapter S of this chapter. MI found bulkhead penetration in the port lazarette and the sonar space not water tight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2022
Resolved 27 June 2022
Resolution: Penetration made water tight. All Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 June 2022
Resolved
The MI shall examine and test the following items to the extent necessary to determine that they are in proper operating condition and fit for the service in which they are intended. MI found hot water heater not strapped down.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2022
Resolved 27 June 2022
Resolution: Heater strapped down. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 13 June 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: MI found electronic and paper charts to be out-of-date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2022
Resolved 27 June 2022
Resolution: New updated charts provided. All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 June 2022
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacle must be constructed of non-combustible materials with no opening in the sides or bottom. MI found combustible waste receptacle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2022
Resolved 27 June 2022
Resolution: Metal waste receptacle provided. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Monitoring of voyage or passage plan
Issued 13 June 2022
Resolved
Must have mean available, satisfactory to the OCMI to obtain or monitor the latest marine broadcast in order to comply with requirements of paragraph (a) of this section. MI found vessel does not monitor local notice to mariners.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2022
Resolved 27 June 2022
Resolution: Master prints out LNTM. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2022
Resolved
An adult life jacket must be provided for each person carried on board. MI found one adult life jacket non-servicable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 June 2022
Resolved 13 June 2022
Resolution: Corrected on the spot
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2022
Resolved
In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. MI found on child size life jacket non-servicable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 June 2022
Resolved 13 June 2022
Resolution: Corrected on the spot
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 20 April 2022
Resolved
Except where specifically stated otherwise, an existing vessel must comply with the intact stability and seaworthiness- regulation which were applicable to the vessel on March10, 1996, or as an alternative, the vessel may comply with the regulations in this part. Vessel's stability letter is no longer IAW the standard due to recent re power.
Vessel is restricted from carrying passengers until it meets stability requirements.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 May 2022
Resolved 4 May 2022
Resolution: Vessel conducted satisfactory stability test.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 November 2021
Resolved
The master of the vessel shall ensure that:
Each EPIRB must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; The EPIRB test required shall be logged or otherwise documented, as applicable.
The monthly EPIRB tests were not properly logged in the log book. Last test was logged in September 2021.
46 CFR 185.728(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2021
Resolved 7 December 2021
Resolution: Vessel master provided proof of monthly EPIRB test completed and properly documented in vessel logbook.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 March 2020
Resolved
46CFR180.20-1(a)(8)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2020
Resolved 22 April 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 March 2020
Resolved
46CFR182.25-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2020
Resolved 22 April 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 January 2020
Resolved
Vessel must complete a satisfactory hull exam prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2020
Resolved 25 February 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 October 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Two outlets in the galley/salon were found improperly wired with revered polarities, and one outlet on bridge was found not grounded. Properly wire electrical receptacles.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2019
Resolved 30 October 2019
Resolution: Vessel found wires were reversed in outlet boxes and corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 October 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead end wires were found on bridge and in the engine room. Remove dead end wires.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2019
Resolved 30 October 2019
Resolution: Dead end wires removed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 October 2019
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. Wire run in engine room found hung with plastic wire ties. Provide metallic wire hangers at intervals of not more than 24 inches.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2019
Resolved 30 October 2019
Resolution: Vessel provided wire hangers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 October 2019
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of non-combustible materials with no openings in the sides or bottom. Plastic waste receptacle found in galley/salon area. Remove plastic waste receptacle.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2019
Resolved 30 October 2019
Resolution: Vessel removed receptacle. Owner decided to remove receptacles within the accomodation spaces and rely on ones located on deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 October 2019
Resolved
A vessel must carry at least one floating waterlight. Waterlight attached to ring life buoy was inoperable. Demonstrate proper operation of waterlight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2019
Resolved 30 October 2019
Resolution: Vessel replaced waterlight and demonstrated operation.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 17 October 2019
Resolved
A vessel with more than one passenger deck and a vessel with overnight accomodations must have a public address system operable from the bridge. Public address sytem was not audible in the passenger acomodation bunk room. Demonstrate proper operation of bunk room public address speaker.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2019
Resolved 30 October 2019
Resolution: Vessel installed and demonstrated additional speaker in bunk room.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 October 2019
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Emergency lighting installed in the passenger accomodation bunk room was not operable. Demonstrate proper operation of emergency lighting.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2019
Resolved 30 October 2019
Resolution: Vessel demonstrated operation of 12V emergency lighting.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 October 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Wire run goes through starbard passenger bunk without installation to protect the passeger from electrical shock. Provide covering for electrical wire run or other means to protect passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2019
Resolved 30 October 2019
Resolution: Vessel provided plastic conduit material to protect passengers from wire runs.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 May 2019
Resolved
PROVIDE UPDATED SAFETY CERTIFICATE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2019
Resolved 17 June 2019
Resolution: CERTIFICATE UPDATED.
Lifesaving › Lifefloat › Serviceable
Issued 14 June 2018
Resolved
Total persons onboard reduced to 40 due to 01-11 man life float out of service.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2018
Resolved 24 July 2018
Resolution: COI amended
Fire Fighting › Structural Fire Protection - General › Superstructure Construction
Issued 14 June 2018
Resolved
Make E/R vapor tight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2018
Resolved 24 July 2018
Resolution: E/R vapor tight
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 14 June 2018
Resolved
Prove proper operation of smoke detector in pax berthing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 June 2018
Resolved 14 June 2018
Resolution: Replaced battery, all sat.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 14 June 2018
Resolved
Prove proper operation of E-lighting in pax berthing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 June 2018
Resolved 14 June 2018
Resolution: Bulb replaced, all sat.
Lifesaving › Lifebuoys › Serviceable
Issued 14 June 2018
Resolved
Replace life ring and water light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 June 2018
Resolved 14 June 2018
Resolution: Both replaced.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 June 2018
Resolved
Prove proper operation of port aft fuel shut off valve.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 June 2018
Resolved 14 June 2018
Resolution: Valve replaced.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 June 2018
Resolved
Label aft remote fuel shut off valves.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2018
Resolved 24 July 2018
Resolution: Labelled
Electrical › Lighting (service) › Lighting Fixture
Issued 14 June 2018
Resolved
Replace light cover in galley portside aft.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 14 June 2018
Resolved 14 June 2018
Resolution: Light cover replaced.
Lifesaving › Lifefloat › Retroreflective Material
Issued 14 June 2018
Resolved
Replace retro tape on both life floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2018
Resolved 24 July 2018
Resolution: Retro replaced.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 10 January 2018
Resolved
Make forward bulkhead in 2nd compartment watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 January 2018
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 10 January 2018
Resolved
Make forward engine room bulkhead watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 11 January 2018
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 1 June 2017
Resolved
Prove proper operation of fireboy shutdown of port genset; vessel restricted to use of stbd genset until corrected.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 12 June 2017
Resolution: Witnessed proper shutdown of gensets with fireboy.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 1 June 2017
Resolved
Provide 5 additional adult and 1 child lifejacket for a total of 51 adult and 6 child; vessel restricted to 46 persons and 5 children on board.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 14 June 2018
Resolution: 45 adult and 7 child for a total of 52.
Communications › Radio Communications › EPIRB
Issued 1 June 2017
Resolved
Register new EPIRB with NOAA.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 12 June 2017
Resolution: New EPIRB registered with NOAA.
Documentation › Certificates/Documents › FCC SSL
Issued 1 June 2017
Resolved
Provide current FCC SSL.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 12 June 2017
Resolution: FCC SSL renewed.
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 1 June 2017
Resolved
Provide FCC Marine Operator's Permit.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 12 June 2017
Resolution: FCC Marine Operator's Permit provided.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 1 June 2017
Resolved
Install battery for smoke detector in berthing space.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 1 June 2017
Resolution: Corrected on the spot.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 1 June 2017
Resolved
Properly mark location of fireboy manual pull station.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 12 June 2017
Resolution: Manual pull station marked.
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 June 2017
Resolved
Properly secure P/S fwd reach rods to the fuel shut-off valves.
Action required: 705 - Other - as specified
Due 1 June 2017
Resolved 1 June 2017
Resolution: Corrected on the spot with mousing wire.
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 June 2017
Resolved
Properly mark stbd fwd and aft fuel shut-off valves.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 12 June 2017
Resolution: Fuel shut-off valves marked.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 1 June 2017
Resolved
Provide captive chain for fish hold hatch cover.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 12 June 2017
Resolution: Chain provided.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 1 June 2017
Resolved
Locate or update a new drill logbook.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 12 June 2017
Resolution: Drill logbook updated.
Lifesaving › Lifefloat › Float-free Link
Issued 1 June 2017
Resolved
Provide line and weak link for lifefloats.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 12 June 2017
Resolution: Weak link and line installed.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 5 April 2016
Resolved
Install grab rails or other device to allow safe access to L/F and EPIRB.
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 28 April 2016
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 5 April 2016
Resolved
Prove proper operation of SSB, restricted to 20nm.
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 5 April 2016
Resolution: SSB operational.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 5 April 2016
Resolved
Provide batteries for 18 L/J lights, restricted to 33 passengers beyond 20nm.
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 5 April 2016
Resolution: New batteries installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 April 2016
Resolved
Prove proper operation of mast head, stern and anchor lights; restricted to daylight and good visibility.
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 7 April 2016
Resolution: Nav lights operational
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 April 2016
Resolved
Provide waterlight for L/F, restricted to 36 passengers.
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 7 April 2016
Resolution: Waterlight provided.
Navigation › Piloting/Steering › Magnetic Compass
Issued 5 April 2016
Resolved
Re-install compass.
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 8 April 2016
Resolution: Compass re-installed.
Lifesaving › Lifefloat › Serviceable
Issued 5 April 2016
Resolved
Patch and paint 15-man lifefloat.
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 17 June 2016