← All vessels
AMIGO
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southwest District (CGD-SW) · Other hulls named AMIGO
AMIGO is a 1973 passenger vessel (inspected). The Coast Guard has recorded 89 inspections since 1985, most recently in January 2026, along with 149 deficiencies, 5 operational controls and 1 casualty investigation in 2018.
Records from 1985 to 2026. Most recent: inspection, 8 January 2026.
- Built
- 1973
- Last inspected
- 8 January 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 149 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2018
Identity
547850
WDL4642
47507
Flag
UNITED STATES
367792890, 368133430
Maury page id
psix-47507
Inspections, by type
…with no type recorded9
Years with a record
39 calendar years (1985–2026)
The 89 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)61.0 ft × 17.3 ft × 5.4 ft
Registered tonnagegross 55 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL FIBERGLASS · MARYSVILLE, WA, UNITED STATES · built 1973
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portVENTURA, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it55 - Regulatory (Subpart C or D), Gross Ton
37 - Regulatory (Subpart C or D), Net Ton
37 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDL4642MMSI 368133430 · active · compulsorily equipped · granted 21 February 2020, expires 21 February 2030
WDJ5950MMSI 367792890 · active · compulsorily equipped · granted 6 June 2017, expires 6 June 2027
WYX2312MMSI 367171530 · expired · compulsorily equipped · granted 7 March 2007, cancelled 8 July 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 89
8 January 2026
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8272378
11 March 2025
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8064796
16 May 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7871136
24 March 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7886663
17 January 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7833299
13 October 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7792286
12 October 2023
In-Service Inspection · Special Consideration · Appeal
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7826950
5 April 2023
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7627726
5 April 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7654649
17 March 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7652755
29 December 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7614243
22 November 2022
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7596378
13 June 2022
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7444811
20 April 2022
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7426529
1 February 2022
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7389304
17 November 2021
In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7353306
15 September 2021
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7312923
10 September 2021
Plan Review "T" Boat · Simplified Stability Test
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7309557
3 May 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7188148
16 March 2020
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6924264
31 January 2020
Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6900447
17 October 2019
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6833057
28 May 2019
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6685051
5 July 2018
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6501764
14 June 2018
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6388016
10 January 2018
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6333252
1 June 2017
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6147035
5 April 2016
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5845632
5 January 2016
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5790892
14 August 2015
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5216842
14 August 2015
Damage Survey
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5216849
9 May 2012
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4282829
3 November 2010
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3884422
14 October 2010
Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3893894
12 May 2009
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3472443
22 April 2009
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3470859
30 March 2009
Administrative Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3444943
21 January 2009
Type not recorded
No type recorded · USCGC ASPEN (WLB 208) · USCG Arctic District (CGD-A) · Activity 3397927
8 May 2008
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3167687
18 November 2007
Type not recorded
No type recorded · USCGC BLACKTIP (WPB 87326) · USCG Arctic District (CGD-A) · Activity 3104890
4 May 2007
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2922299
30 March 2007
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2893551
1 May 2006
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2606160
19 April 2005
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2326278
29 March 2005
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2310729
29 June 2004
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2116564
15 June 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2099559
10 June 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1810282
1 April 2003
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1767226
2 December 2002
Type not recorded
No type recorded · USCGC ALERT (WMEC 630) · Activity 1719856
19 June 2002
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1637317
17 April 2002
Construction Oversight · Plan Review "T" Boat
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1612423
31 May 2001
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1373632
5 April 2001
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1362095
25 April 2000
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1423372
26 May 1999
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1413548
22 April 1999
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1462749
11 March 1999
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 804924
17 June 1998
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 794055
5 May 1998
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1430549
30 April 1997
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1406103
4 April 1997
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1416481
5 June 1996
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1385730
25 April 1995
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 862518
11 April 1995
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1374252
3 June 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1017285
3 May 1994
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 858682
19 May 1993
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1151807
17 May 1993
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 832884
4 May 1993
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1149444
29 June 1992
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 960358
19 May 1992
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 949389
30 May 1991
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1241605
13 May 1991
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 910905
19 April 1991
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1221021
31 October 1990
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1241625
16 August 1990
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1225381
11 June 1990
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 907414
12 June 1989
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1207048
18 April 1989
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1345900
13 December 1988
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1210690
13 June 1988
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1205036
27 May 1987
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1333215
7 April 1987
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1026546
2 January 1987
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1309661
25 June 1986
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 986528
3 July 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 982883
20 June 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1290630
13 June 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 982706
Deficiency record · 149
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 May 2024
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. A. 40-B:C fire extinguisher located under the ladder to the wheel house found to be unserviceable. Service or replace extinguisher to meet minimum requirements as indicated on the COI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 5 April 2023
Resolved
Each vessel must meet the applicable requirements in Subchapter S of this chapter. MI found two hatch coveres with out securing devices.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 22 November 2022
Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion resistant clip. No clip was on the light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 22 November 2022
Resolved
The floating waterlight must be attached around the body of the life float. 2 of 2 floating waterlights tied to inside grab line.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 22 November 2022
Resolved
The owner or operator shall be prepared to test steering system and make available for inspection to determine to the extent necessary to prove proper operation. Hydraulic ram to jockey bar bolt loost at jockey bar mount. (defer to January 2023 drydock)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 June 2022
Resolved
At least one ring life buoy must be fitted with a lifeline. MI found life buoy with no life line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 June 2022
Resolved
Each floating watertight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. MI found floating light with not corrosion-resistant clip.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 13 June 2022
Resolved
ach paddle must be lashed to the life float to which it belongs. MI found life float paddle not lashed.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 13 June 2022
Resolved
he name of the vessel must be marked or painted in clearly legible letters on each life float paddle.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 June 2022
Resolved
ach vessel must meet the applicable requirements in Sub chapter S of this chapter. MI found bulkhead penetration in the port lazarette and the sonar space not water tight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 June 2022
Resolved
The MI shall examine and test the following items to the extent necessary to determine that they are in proper operating condition and fit for the service in which they are intended. MI found hot water heater not strapped down.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 13 June 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: MI found electronic and paper charts to be out-of-date.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 June 2022
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacle must be constructed of non-combustible materials with no opening in the sides or bottom. MI found combustible waste receptacle.
10 - Safety of Navigation › N/A - No Subsystem › Monitoring of voyage or passage plan
Issued 13 June 2022
Resolved
Must have mean available, satisfactory to the OCMI to obtain or monitor the latest marine broadcast in order to comply with requirements of paragraph (a) of this section. MI found vessel does not monitor local notice to mariners.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2022
Resolved
An adult life jacket must be provided for each person carried on board. MI found one adult life jacket non-servicable.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2022
Resolved
In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. MI found on child size life jacket non-servicable.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 20 April 2022
Resolved
Except where specifically stated otherwise, an existing vessel must comply with the intact stability and seaworthiness- regulation which were applicable to the vessel on March10, 1996, or as an alternative, the vessel may comply with the regulations in this part. Vessel's stability letter is no longer IAW the standard due to recent re power.
Vessel is restricted from carrying passengers until it meets stability requirements.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 November 2021
Resolved
The master of the vessel shall ensure that:
Each EPIRB must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; The EPIRB test required shall be logged or otherwise documented, as applicable.
The monthly EPIRB tests were not properly logged in the log book. Last test was logged in September 2021.
46 CFR 185.728(c)
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 March 2020
Resolved
46CFR180.20-1(a)(8)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 March 2020
Resolved
46CFR182.25-1
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 January 2020
Resolved
Vessel must complete a satisfactory hull exam prior to carrying passengers.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 October 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Two outlets in the galley/salon were found improperly wired with revered polarities, and one outlet on bridge was found not grounded. Properly wire electrical receptacles.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 October 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead end wires were found on bridge and in the engine room. Remove dead end wires.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 October 2019
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. Wire run in engine room found hung with plastic wire ties. Provide metallic wire hangers at intervals of not more than 24 inches.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 October 2019
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of non-combustible materials with no openings in the sides or bottom. Plastic waste receptacle found in galley/salon area. Remove plastic waste receptacle.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 October 2019
Resolved
A vessel must carry at least one floating waterlight. Waterlight attached to ring life buoy was inoperable. Demonstrate proper operation of waterlight.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 17 October 2019
Resolved
A vessel with more than one passenger deck and a vessel with overnight accomodations must have a public address system operable from the bridge. Public address sytem was not audible in the passenger acomodation bunk room. Demonstrate proper operation of bunk room public address speaker.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 October 2019
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. Emergency lighting installed in the passenger accomodation bunk room was not operable. Demonstrate proper operation of emergency lighting.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 October 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Wire run goes through starbard passenger bunk without installation to protect the passeger from electrical shock. Provide covering for electrical wire run or other means to protect passengers.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 May 2019
Resolved
PROVIDE UPDATED SAFETY CERTIFICATE.
Lifesaving › Lifefloat › Serviceable
Issued 14 June 2018
Resolved
Total persons onboard reduced to 40 due to 01-11 man life float out of service.
Fire Fighting › Structural Fire Protection - General › Superstructure Construction
Issued 14 June 2018
Resolved
Make E/R vapor tight.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 14 June 2018
Resolved
Prove proper operation of smoke detector in pax berthing.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 14 June 2018
Resolved
Prove proper operation of E-lighting in pax berthing.
Lifesaving › Lifebuoys › Serviceable
Issued 14 June 2018
Resolved
Replace life ring and water light.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 June 2018
Resolved
Prove proper operation of port aft fuel shut off valve.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 June 2018
Resolved
Label aft remote fuel shut off valves.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 June 2018
Resolved
Replace light cover in galley portside aft.
Lifesaving › Lifefloat › Retroreflective Material
Issued 14 June 2018
Resolved
Replace retro tape on both life floats.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 10 January 2018
Resolved
Make forward bulkhead in 2nd compartment watertight.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 10 January 2018
Resolved
Make forward engine room bulkhead watertight.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 1 June 2017
Resolved
Prove proper operation of fireboy shutdown of port genset; vessel restricted to use of stbd genset until corrected.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 1 June 2017
Resolved
Provide 5 additional adult and 1 child lifejacket for a total of 51 adult and 6 child; vessel restricted to 46 persons and 5 children on board.
Communications › Radio Communications › EPIRB
Issued 1 June 2017
Resolved
Register new EPIRB with NOAA.
Documentation › Certificates/Documents › FCC SSL
Issued 1 June 2017
Resolved
Provide current FCC SSL.
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 1 June 2017
Resolved
Provide FCC Marine Operator's Permit.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 1 June 2017
Resolved
Install battery for smoke detector in berthing space.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 1 June 2017
Resolved
Properly mark location of fireboy manual pull station.
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 June 2017
Resolved
Properly secure P/S fwd reach rods to the fuel shut-off valves.
Fire Fighting › Remote Fuel Shutoff › General
Issued 1 June 2017
Resolved
Properly mark stbd fwd and aft fuel shut-off valves.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 1 June 2017
Resolved
Provide captive chain for fish hold hatch cover.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 1 June 2017
Resolved
Locate or update a new drill logbook.
Lifesaving › Lifefloat › Float-free Link
Issued 1 June 2017
Resolved
Provide line and weak link for lifefloats.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 5 April 2016
Resolved
Install grab rails or other device to allow safe access to L/F and EPIRB.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 5 April 2016
Resolved
Prove proper operation of SSB, restricted to 20nm.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 5 April 2016
Resolved
Provide batteries for 18 L/J lights, restricted to 33 passengers beyond 20nm.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 April 2016
Resolved
Prove proper operation of mast head, stern and anchor lights; restricted to daylight and good visibility.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 April 2016
Resolved
Provide waterlight for L/F, restricted to 36 passengers.
Navigation › Piloting/Steering › Magnetic Compass
Issued 5 April 2016
Resolved
Re-install compass.
Lifesaving › Lifefloat › Serviceable
Issued 5 April 2016
Resolved
Patch and paint 15-man lifefloat.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 August 2015
Resolved
Prior to operating with pasengers, make proper repairs to starboard wet exhaust piping in fish hold.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 9 May 2012
Resolved
Replace 7 adult PFDs and 2 child-size PFDs. Vessel restricted to not more than 44 total persons on Limited Coastwise route.
Documentation › Logs/Records › Drug Test Records
Issued 9 May 2012
Resolved
Provide pre-employment drug test results for Conor Shanahan and add him to the random drug testing crew list from ASTS prior to Conor working in a safety sensitive position.
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 May 2012
Resolved
Repair audible and visual high-water bilge alarm for lazarette.
Fire Fighting › Fire Bucket › Availability
Issued 9 May 2012
Resolved
Label and provide lanyards for (3) fire buckets.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 8 May 2008
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering › Bilge Water Management System › Not Operational
Issued 8 May 2008
Resolved
PROVIDE ADEQUATE BILGE PUMPS IN ACCORDANCE WITH 46 CFR 182.520
Navigation › Piloting/Steering › Marine Charts
Issued 8 May 2008
Resolved
PROVIDE UPDATED CHARTS ON BOARD FOR VESSEL'S OPERATING AREA
Lifesaving › Rescue Boat › Carriage Requirement
Issued 4 May 2007
Resolved
It has been determined that the vessel is arranged such that an unconscious person cannot be recovered from the water without additional equipment. Provide rescue boat or platform or other suitable arrangement IAW 46 CFR 180.210 within 30 days to the satisfaction of attending USCG Marine Inspector.
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 19 April 2005
Resolved
Recharge or replace fixed firefighting equipment.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 15 June 2004
Resolved
Add/repair retroreflective tape to lifejackts
Lifesaving › Buoyant Apparatus
Issued 15 June 2004
Resolved
Properly connect lifefloats to painter line and weak link.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 15 June 2004
Resolved
Replace 4 condemned adult life jackts and 1 child size life jacket IAW 46 CDR 180.71 LEGACY COMPONENT DESC: Condition
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 15 June 2004
Resolved
Clean excess oily water from engine room bilge IAW 46 CFR 176.830(b)
Lifesaving › Lifejacket/PFD (General)
Issued 10 June 2003
Resolved
5 adult lifejackets and 1 child lifejacket failed due to punctured kapok bags. Passenger count is reduced to 46 adults and 5 children until the matter is corrected. LEGACY COMPONENT DESC: Condition
Lifesaving › Lifebuoys › Quantity
Issued 19 June 2002
Resolved
Lifering lifeline not secured properly and the inner ring was wasted.
Engineering › Fuel Oil Service System
Issued 3 May 2002
Resolved
USCG Type A1 hose in the fuel oil return system for the new main diesel engines exceeded 30 inches in length. Fuel return system must meet 46 CFR 182.455 (annealed copper tubing), 182.720(e) [SAE-J-1942], or 182.720 (e)(3)(v) [USCG Type A1, less than 30 inches with proper connections]. LEGACY COMPONENT DESC: Piping
Engineering
Issued 5 April 2001
Resolved
Starboard side strut cutless bearing had no rubber the last 1 1/2 inches, water grooves could not be seen and the metal was badly chipped.
Construction/Loadline
Issued 5 April 2001
Resolved
PORT SIDE, OUTBOARD AFT CORNER, STAINLESS STEEL BOLT ON THE INTERMEDIATE STRUT CHIPPED AND DETERIORATING DUE TO STRAY CURRENT OR DISSIMILAR METALS.
Construction/Loadline
Issued 25 April 2000
Resolved
Attach a chain to the passenger cabin emergency exit hatch.
Construction/Loadline
Issued 25 April 2000
Resolved
Secure coaming and cover for fishhold.
Lifesaving
Issued 25 April 2000
Resolved
Provide first aid kit with current non-expired contents.
Fire Fighting
Issued 26 May 1999
Resolved
Install smoke detectors in berthing IAW 46 CFR 181.450.
Accommodation/Occupational Safety
Issued 26 May 1999
Resolved
Install lock on MSD overboard IAW 33 CFR.
Engineering
Issued 26 May 1999
Resolved
Install new approved F/O hose on port M/E racor filter IAW 46 CFR 182.720.
Fire Fighting
Issued 26 May 1999
Resolved
Install vent closures on engine room vents IAW 46 CFR 182.465
Navigation
Issued 26 May 1999
Resolved
Provide proof of new publication of 46 CFR subchapter T
Construction/Loadline
Issued 26 May 1999
Resolved
Make collision bulkhead watertight or provide proof that collision bulkheadpenetration is watertight IAW 46 CFR 179.310.
Construction/Loadline
Issued 22 April 1999
Resolved
Install metallic fittings in PVC bilge system outside of engineroom where piping penetrates bulkheads.
Construction/Loadline
Issued 22 April 1999
Resolved
Replace PVC piping in engine room bilge system with metallic piping.
Engineering
Issued 5 May 1998
Resolved
Make all flexible fuel lines on main engine double clamped with proper fittings or manufactured with approved hose. This item must be corrected before operating with passengers.
Engineering
Issued 5 May 1998
Resolved
Repair fuel leak on port generator. This item must be completed before operating with passengers.
Electrical
Issued 3 May 1994
Resolved
REPLACE WING NUTS ON BATTERY TERMINALS.
Engineering
Issued 3 May 1994
Resolved
REMOVE OILY WATER FROM E/R BILGES.
Lifesaving
Issued 3 May 1994
Resolved
PROVIDE SPACER BETWEEN STACKED LIFE FLOATS.
Lifesaving
Issued 3 May 1994
Resolved
CLEAN MANUFACTURER'S PLATE ON LIFE FLOATS.
Electrical
Issued 3 May 1994
Resolved
PROVIDE COVERS FOR BATTERY BOXES.
Lifesaving
Issued 3 May 1994
Resolved
PROVIDE 10 ADDITIONAL ADULT PFD'S. VESSEL LIMITED TO 41 POB ON LIMITED COASTWISE ROUTE UNITL PFD'S ARE PROVIDED.
Lifesaving
Issued 17 May 1993
Resolved
PROVIDE WATERLIGHT FOR 25 PERSON LIFE FLOAT.
Engineering
Issued 17 May 1993
Resolved
PROVE PROPER OPERATION OF (2) EMERGENCY FUEL SHUTOFFS IN LAZARETTE.
Construction/Loadline
Issued 17 May 1993
Resolved
REMOVE VALVE INSTALLED IN COLLISION BULKHEAD, OR INSTALL METALLIC FIXED PIPING BETWEEN VALVE AND BILGE MANIFOLD.
Fire Fighting
Issued 17 May 1993
Resolved
PROVIDE PROPER FIRE HOSE.
Lifesaving
Issued 17 May 1993
Resolved
PROVIDE CLIP TO PROPERLY ATTACH WATERLIGHT TO RING BUOY.
Construction/Loadline
Issued 17 May 1993
Resolved
PROVE PROPER OPERATION OF HAND FIRE/BILGE PUMP.
Construction/Loadline
Issued 4 May 1993
Resolved
REPAIR DAMAGED AREA OF HULL, NEAR BOW ON PORT SIDE, ABOVE WATERLINE, NEAR CHINE.
Lifesaving
Issued 4 May 1993
Resolved
REPAIR OR REMOVE CRACKED TROLLING ROD HOLDER ON PORT SIDE OF TRANSOM.
Construction/Loadline
Issued 4 May 1993
Resolved
REPAIR OR REPLACE SECURING LATCHES FOR PORT AND STARBOARD REMOVABLE (PASSENGER ACCESS) RAILS.
Fire Fighting
Issued 19 May 1992
Resolved
REPLACE BRACKETS FOR THREE B-II FIRE EXTINGUISHERS.
Electrical
Issued 19 May 1992
Resolved
REMOVE OLD GROUNDING STRAPS IN AFT STEERING SPACE.
Electrical
Issued 19 May 1992
Resolved
RECONNECT AND COVER JUNCTION BOX, LOCATED PORTSIDE ENGINE ROOM.
Construction/Loadline
Issued 19 May 1992
Resolved
TREAT ROT IN ENGINE ROOM BELOW STBD SIDE PASSENGER TOILET.
Construction/Loadline
Issued 19 May 1992
Resolved
DOUBLE CLAMP THREE FLEX HOSES LEADING FROM SEA VALVES IN ENGINE ROOM.
Navigation
Issued 19 May 1992
Resolved
INSTALL COTTER PINS IN BOTH TIE ROD PINS IN STEERING GEAR.
Lifesaving
Issued 19 May 1992
Resolved
REAPPLY RETROREFLECTIVE TAPE TO THREE (03) PFD'S.
Electrical
Issued 19 May 1992
Resolved
PROVIDE MEANS TO DISCONNENCT SHORE POWER CABLE AT OR NEAR MAIN DISTRIBUTIONPANEL.
Construction/Loadline
Issued 19 May 1992
Resolved
PROVE FISHHOLD HATCH WATERTIGHT OR RAISE COAMING TO 12 INCHES AND MAKE WEATHERTIGHT.
Construction/Loadline
Issued 19 May 1992
Resolved
SEAL THRU-BULKHEAD PENETRATIONS IN FWD BULKHEADS IN ENGINEROOM AND AFT STEERING SPACE.
Lifesaving
Issued 13 May 1991
Resolved
REPLACE OARS FOR BOTH LIFEFLOATS. PROVE OPERATION OF WATERLIGHT FOR 25 PERSON LIFEFLOAT. VESSEL NOT TO OPERATE WITH PASSENGERS UNTIL THIS IS COMPLETED.
Navigation
Issued 13 May 1991
Resolved
PROVIDE BELL FOR VESSEL.
Navigation
Issued 13 May 1991
Resolved
PROVIDE TIDE AND CURRENT TABLES AND COPY OF RULES OF THE ROAD.
Electrical
Issued 13 May 1991
Resolved
PROVIDE AMP METER FOR 110V SYSTEM.
Engineering
Issued 13 May 1991
Resolved
DOUBLE CLAMP HOSES ON EXHAUST WATER-INJECTION SYSTEM.
Electrical
Issued 13 May 1991
Resolved
PROVIDE COVER FOR LIGHT FIXTURE IN WAY OF FORWARD FUEL TANK SPACE.
Engineering
Issued 13 May 1991
Resolved
PROPERLY SECURE PORT FUEL-SHUTOFF REACH ROD.
Construction/Loadline
Issued 13 May 1991
Resolved
COVER HOLE IN FORWARD BULKHEAD OF FORWARD FUEL TANK SPACE.
Electrical
Issued 11 June 1990
Resolved
REPAIR MOUNTING TO PORT DECK LIGHT ON TOP OF HOUSE.
Deck/Cargo
Issued 11 June 1990
Resolved
PROVIDE A SUCTION AND A DISCHARGE HOSE ON HAND FIRE/BILGE PUMP OF ADEQUATE LENGTH TO REACH THE WATER FROM THE BOAT AND TO REACH THE INTERIOR SECTION OF THE BOAT.
Accommodation/Occupational Safety
Issued 11 June 1990
Resolved
REMOVE GREASE BUILDUP FROM THE GALLEY VENT.
Lifesaving
Issued 11 June 1990
Resolved
REPLACE OUTDATED BATTERY IN EPIRP.
Engineering
Issued 11 June 1990
Resolved
PROVIDE FLAME SCREENS FOR THREE FUEL TANK VENTS IAW 46 CFR 182.20-35(D).
Accommodation/Occupational Safety
Issued 11 June 1990
Resolved
LABEL EMERGENCY ESCAPE HATCH IAW 46 CFR 185.30-15.
Electrical
Issued 11 June 1990
Resolved
LABEL CIRCUIT BREAKER WITH NAME OF CIRCUIT PROTECTED.
Deck/Cargo
Issued 11 June 1990
Resolved
PROVIDE A BILGE SUCTION STRAINER IN FORWARD BUNKROOM IAW 46 CFR 182.25-5(B)
Electrical
Issued 11 June 1990
Resolved
PROVIDE A FREQUENCY METER FOR AC GENERATOR IAW 46 CFR 183.10-5(A)(8).
Lifesaving
Issued 11 June 1990
Resolved
RETIE PENDANTS ON BOTH LIFE FLOATS IAW 46 CFR 160.010-3(G).
Lifesaving
Issued 11 June 1990
Resolved
LABEL PADDLES (4) TO LIFEFLOATS IAW 46 CFR 185.30-5(A) AND LASH PADDLE TO 11 MAN LIFEFLOAT TO LIFEFLOAT IAW 46 CFR 180.15-10.
Lifesaving
Issued 12 June 1989
Resolved
PROVIDE APPROPRIATE SIZE WEAK LINK FOR LIFE FLOATS IAW 46 CFR 180.20-1(A).
Construction/Loadline
Issued 12 June 1989
Resolved
INSTALL SCREEN IN BILGE SUCTION IN BUNKROOM COMPT. IAW 46 CFR 182.25-5(B).
Lifesaving
Issued 12 June 1989
Resolved
PROVIDE VSL WITH 6 ADDITIONAL ADULT PFDS.
Lifesaving
Issued 12 June 1989
Resolved
PROVIDE VSL WITH 6 APPROVED HAND HELD ORANGE SMOKE DISTRESS SIGNALS IAW 46 CFR 180.35-5(A).
Accommodation/Occupational Safety
Issued 18 April 1989
Resolved
REPLACE SEA VALVE TO STARBOARD HEAD.
Engineering
Issued 27 May 1987
Resolved
PROVIDE STRAINERS AND CHECK VALVES FOR ALL BILGE SUCTION LINES.
Lifesaving
Issued 27 May 1987
Resolved
PROVIDE PAINTER FOR LIFE FLOATS THAT IS AT LEAST 100 FEET IN LENGTH.
Lifesaving
Issued 27 May 1987
Resolved
PUT VESSEL NAME ON LIFE FLOAT PADDLES.
Construction/Loadline
Issued 27 May 1987
Resolved
RENEW CRACKED PILOTHOUSE WINDOW (STBD SIDE)
Electrical
Issued 13 June 1985
Resolved
REPAIR AND PROVE OPERATIONAL SHIP'S EMERGENCY LIGHTING.
Engineering
Issued 13 June 1985
Resolved
PROVIDE METAL COVER FOR GLASS FUEL FILTER BOWL.
Lifesaving
Issued 13 June 1985
Resolved
PROVIDE ESCAPE HATCH WITH CAPTURE CHAIN.
Lifesaving
Issued 13 June 1985
Resolved
PROVIDE NEW PADDLES FOR 11 PERSON LIFE FLOAT.
Casualty record · 1
5 July 2018Routine · role: Involved in a Marine Casualty · 1 dead · activity 6501764
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.