CAPTAIN GABE

CAPTAIN GABE is a 1973 passenger vessel (inspected). The Coast Guard has recorded 95 inspections since 1982, most recently in June 2025, along with 192 deficiencies and 1 casualty investigation in 2005.

Records from 1982 to 2025. Most recent: inspection, 18 June 2025.

Built
1973
Last inspected
18 June 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE9278
Flag
UNITED STATES
338022000, 368486820
Maury page id
psix-47508

Inspections, by type

…with no type recorded17
Years with a record 37 calendar years (1982–2025)
The 95 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)85.1 ft × 21.0 ft × 8.8 ft
Registered tonnagegross 93 / net 73
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAMCRAFT INC · CROWN POINT, LA, UNITED STATES · built 1973
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 1 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
73 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDR3156MMSI 368486820 · active · compulsorily equipped · granted 15 July 2026, expires 15 July 2036
WDE9278MMSI 338022000 · active · compulsorily equipped · granted 3 April 2019, expires 18 June 2029 · licensed under a name not among this hull’s recorded names (not shown)
WDC7815MMSI 366403000 · expired · compulsorily equipped · granted 18 November 2005, cancelled 23 January 2016
WCP3717MMSI not assigned · expired · compulsorily equipped · granted 13 December 1994, cancelled 12 February 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 95

18 June 2025 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8126883
26 February 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8085144
25 July 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7967147
19 June 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7938252
23 August 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7785655
12 July 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7740863
14 April 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7668631
7 February 2023 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7633457
3 January 2023 Examination of Repairs · In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7616082
14 September 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7558918
3 August 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7278005
4 February 2021 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7135925
19 June 2020 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6979778
29 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6844844
6 August 2019 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6774449
7 February 2019 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6621502
11 July 2018 DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6475565
4 April 2018 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6389458
22 June 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6183224
25 March 2017 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6112863
2 August 2016 DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5960906
19 September 2011 Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4130234
1 February 2011 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3937400
1 January 2011 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3996678
30 October 2010 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3891980
21 October 2010 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3874610
21 September 2010 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3834272
13 June 2008 Internal Structural Exam · Deficiency Check · Inclining Experiment · Drydock Exam · Hull Examination · COI Inspection · Welding Related Inspections Qualification Testing
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3235798
9 January 2006 Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2563700
13 March 2005 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2313116
23 December 2004 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2264084
30 November 2004 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2250747
16 November 2004 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2241974
16 December 2003 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1980005
30 October 2002 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1698631
25 September 2002 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1679885
12 September 2002 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1677227
6 August 2002 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1668874
19 November 2001 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1077248
31 October 2001 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 1448378
30 April 2001 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1447092
9 October 2000 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1379196
6 September 2000 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 822559
31 August 2000 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1433724
10 July 2000 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 819946
4 November 1999 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 799734
29 September 1999 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1410174
24 June 1999 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1456715
28 October 1998 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 804140
8 October 1998 Deficiency Check · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1395039
29 September 1998 Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 802020
9 September 1998 Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 796863
26 August 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1372340
14 August 1998 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1386319
14 October 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1439923
9 October 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1405982
11 September 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 828071
18 July 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1088882
10 July 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1460883
26 June 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 934914
27 December 1995 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1185975
20 October 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1374402
7 September 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1185366
7 July 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 882104
7 July 1995 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1192774
8 February 1995 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 837642
29 December 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 851835
31 October 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1183666
6 October 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1172658
29 September 1994 Inclining Experiment
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 870326
29 September 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1178668
15 September 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1181812
1 July 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1178562
29 June 1994 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1137641
10 September 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1143476
1 May 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397936
14 December 1992 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407095
8 June 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1263050
8 June 1991 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1249432
11 January 1991 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 933286
10 December 1990 Hull Examination · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1230103
20 November 1990 Deficiency Check · Drydock Extension
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 906230
8 June 1990 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 901346
13 July 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350232
15 June 1989 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1195706
17 June 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002812
10 July 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988161
30 December 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995092
3 January 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977892
11 December 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1283958
29 December 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970756
20 October 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273516
12 September 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970234
7 January 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 967417
6 January 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1274248

Deficiency record · 192

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 June 2025 Resolved
vessel must be provided with individual bilge lines and bilge suctions for each watertight compartment. The engine room, bilge suction was inoperable. Demonstrate bilge suction from the engine room, galley and berthing space. 46 CFR 182.510
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2025
Resolution: Witnessed operation, all sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 June 2025 Resolved
The port generator starting battery was found to be unsecured. Provide battery with proper securing device to prevent movement in all sea conditions. 46 CFR 183.354
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 June 2025
Resolution: Witnessed correction, all sat
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 June 2025 Resolved
The engine room escape scuttle was found with unreadable labeling. Provide hatch with “EMERGENCY EXIT, KEEP CLEAR” 46 CFR 185.606
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 June 2025
Resolution: Witnessed correction, all sat
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 June 2025 Resolved
Both fire hydrants were found without spanner wrenches. Provide each fire station with appropriate spanner wrenches. 46 CFR 181.310
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 June 2025
Resolution: Witnessed installation, all sat
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 June 2024 Resolved
Provide vessel with complete but simple instructions for the operation of the fixed CO2 system. Instructions can include steps like: make sure no persons are in the compartment, get captains permission, secure ventilation, secure fuel valves....etc.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2024
Resolved 9 July 2024
Resolution: Instructions were provided.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 June 2024 Resolved
Provide bunk room emergency escape with "KEEP CLEAR"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2024
Resolved 9 July 2024
Resolution: Labeling was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 June 2024 Resolved
Label upper adult life jacket storage with type (Adult) and quantity.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2024
Resolved 9 July 2024
Resolution: Labeling was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 June 2024 Resolved
Label Child life jacket storage with type (Child) and quantity.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2024
Resolved 9 July 2024
Resolution: Labeling was provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 June 2024 Resolved
Port generator was found with exposed wire nuts on two wires. Make connections permanent with crimped connections or provide junction box for wire nuts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2024
Resolved 9 July 2024
Resolution: Crimped connectors with heat shrink was installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 July 2023 Resolved
Fixed firefighting systems are required to conduct annual inspections by an approved party. Vessel fixed firefighting system found to be overdue for inspection. Provide service report.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2023
Resolution: Received servicing report. Servicing was conducted on 14 July 2023 by Global Fire.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2023 Resolved
Nonconducting mats or grating must be provided on the deck in front of each switchboard. Switchboard located in generator space found to be missing non-conductive matting. Install non conductive matting in front of switchboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2023
Resolved 14 July 2023
Resolution: Vessel acquired new matting.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 3 January 2023 Resolved
Each vessel certificated on an Oceans Route in cold water must provide IBA/life rafts with an aggregate capacity of 100% of persons permitted on board. One (01) life raft (25 man capacity) and mount detached from vessel while underway. Total personnel count reduced to fifty-five (55) until proper repairs are made and life raft mounted to it's original condition to the satisfaction of the CG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 16 March 2023
Resolution: Total person count reduced to fifty-five (55) until deficiency is rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2021 Resolved
Must secure Battery Boxes in lazerete space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2021
Resolved 18 August 2021
Resolution: Pic sent to attending MI...[name withheld]
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 19 June 2020 Resolved
Crew members missing proof of medical certificates. Must provide proof to CG Marine Inspectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2020
Resolved 16 July 2020
Resolution: Verified by email...[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Remove electrical strips in wheel house and install required junction boxes for navigation equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 2 December 2019
Resolution: Removed power strips.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Remove / Replace / Repair outlet marked "Bad" in galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 2 December 2019
Resolution: Outlet repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Replace / Repair switch for the main water heater.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 2 December 2019
Resolution: Switch removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 30 January 2020
Resolved 14 August 2020
Resolution: Electrical plan has been submitted, reviewed, approved and filed...[name withheld]
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 August 2019 Resolved
Obtain valid FCC safety radio certificate.
Action required: 10 - Deficiency Rectified
Due 6 August 2019
Resolved 6 August 2019
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 August 2019 Resolved
Grease port fuel shut-off valve (wouldn't fully close).
Action required: 10 - Deficiency Rectified
Due 6 August 2019
Resolved 6 August 2019
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 August 2019 Resolved
Replace non-CG approved life buoys.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2019
Resolved 20 August 2019
Resolution: Replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 6 August 2019 Resolved
Replace life float (no longer serviceable). Total persons on board reduced to 80 until corrected.
Action required: 705 - Other - as specified
Due 5 September 2019
Resolved 22 August 2019
Resolution: Removed & COI amended to reduce pax
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 August 2019 Resolved
Provide pressure vessel relief valve setting and pressure gauge calibration report.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2019
Resolved 22 August 2019
Resolution: Pressure vessel removed and COI amended.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 August 2019 Resolved
Correct dead-end wiring found above center MDE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2019
Resolved 20 August 2019
Resolution: Cables removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 August 2019 Resolved
Replace broken gauge on hydraulics on fwd anchor winch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2019
Resolved 20 August 2019
Resolution: Gauge replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 11 July 2018 Resolved
Provide marking for forward emergency exit on exterior of vessel in 2 inch lettering "Emergency Exit, Keep Clear".
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 31 July 2018
Resolution: Emergency exit marking provided.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 11 July 2018 Resolved
Make aft engine room/forward Laz bulkhead permanently watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 31 July 2018
Resolution: Bulkhead perm watertight.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 April 2018 Resolved
Repair damaged rails located amidship on both port and starboard side.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2018
Resolved 11 April 2018
Resolution: Rails were properly welded.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2018 Resolved
Make proper repairs to damaged shore power cable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2018
Resolved 11 April 2018
Resolution: Shore power cable replaced.
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 March 2017 Resolved
Identify loss of propulsion and repair to satisfaction of attending CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2017
Resolution: The failure was identified as non servicable batteries, new batteries have been installed.
Construction/Loadline › Structures › Machinery Space Opening
Issued 30 October 2010 Resolved
Remove water tight door in way of forward bulkhead in the engine room and make watertight. Vessel is currently working as a passenger vessel and not in the mineral and oil industry. This is a condition stated on the stability letter allowing the water tight door in way of the forward bulkhead in the engine room.
Action required: 705 - Other - as specified
Due 31 March 2011
Resolved 31 March 2011
Resolution: Water Tight door was removed in forward bulkhead in the engine room and replaced with welded both sides sheet to make water tight. A water tight hatch was installed on forward of interior accommodation space aft entrance with ladder IAW 46 CFR 177.500.
Engineering › Lubricating Oil Storage/Transfer System › Inlet
Issued 21 September 2010 Resolved
Replace flexible hose between deck and lube oil storage tank IAW 46 CFR 182.720
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2010
Resolved 21 October 2010
Resolution: New hose and clamps have been installed.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 21 September 2010 Resolved
Securely install power cable in way of stbd generator IAW 46 CFR 183
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 October 2010
Resolved 21 October 2010
Resolution: Cable is properly secured.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 21 September 2010 Resolved
Provide protective cover for breaker box for air compressor located portside aft engine room IAW 46 CFR 183.330
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2010
Resolved 21 October 2010
Resolution: New protective cover has been installed.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 21 September 2010 Resolved
Repair exhaust leak on port generator located at flange.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2010
Resolved 21 October 2010
Resolution: Cracked weld was revealed to have been the cause, weld was rewelded and tested sat.
Engineering › Steering Gear System › Ram Seal
Issued 3 February 2006 Resolved
Make repairs as necessary to eliminate loss of hydraulic fluid from steering gear hydraulic ram.
Due 3 March 2006
Resolved 10 March 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 12 January 2006 Resolved
Issued requirement by e-mail to upgrade three B-I estinguishers to B-II extinguishers, as required by COI and "Old T", and provide hydro servicing for two portables (laundry room B-III & E/R Stbd B-II).
Due 3 March 2006
Resolved 10 March 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 January 2006 Resolved
Replace port/STBD entry way railing (existing is plastic chain and cotton rope) with cable
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 3 February 2006
Fire Fighting › Fire Main › Condition
Issued 11 January 2006 Resolved
Prove proper operation of fire pump.
Due 31 January 2006
Resolved 3 February 2006
Engineering › Pressure Vessel › Relief Valve
Issued 11 January 2006 Resolved
Prove proper operation of S/R valve.
Due 31 January 2006
Resolved 3 February 2006
Engineering › Pressure Vessel › Relief Valve
Issued 6 January 2006 Resolved
Make pressure vessel available for ISE and test operational test of the safety relief valve.
Action required: 705 - Other - as specified
Due 12 January 2006
Resolved 11 January 2006
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 6 January 2006 Resolved
Clean bilge IWO the E/R.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 11 January 2006
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 6 January 2006 Resolved
Secure circuit breaker box cover in the generator room.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 11 January 2006
Engineering › Steering Gear System › Bracket/Clamp
Issued 6 January 2006 Resolved
Make repair to the STBD side rudder stop.
Action required: 705 - Other - as specified
Due 3 March 2006
Resolved 10 March 2006
Fire Fighting › Ventilation Systems › Ducts
Issued 6 January 2006 Resolved
Clean exhaust IWO the dryer discharge.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 3 February 2006
Engineering › Bilge Water Management System › Not Operational
Issued 6 January 2006 Resolved
Repair bilge high water alarm IWO galley comp.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 3 February 2006
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 6 January 2006 Resolved
Make temp repair of the pin holes to the sewage tank.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 11 January 2006
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 6 January 2006 Resolved
Replace the sewage tank at the next DD.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 16 September 2009
Resolution: Corrected
Electrical › Electric Supply System (service) › Cable
Issued 6 January 2006 Resolved
Secure electrical control board under the bridge control.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 11 January 2006
Lifesaving › Lifefloat › Capacity
Issued 6 January 2006 Resolved
Stencil L/F capacity and vsl name.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 11 January 2006
Communications › Radio Communications › EPIRB
Issued 6 January 2006 Resolved
Registration of the EPIRB.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 3 February 2006
Lifesaving › Lifefloat › Float Free
Issued 6 January 2006 Resolved
Properly rig L/F painters, make all grab lines and painters orderly, and remove zip ties.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 3 February 2006
Navigation › Piloting/Steering › US Coast Pilot
Issued 6 January 2006 Resolved
Obtain proper navigation publications.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 11 January 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 January 2006 Resolved
Deck railing courses should not exceed 12." NOTE: As of 03 FEB 06, most railing course distance violations had been addressed. Remainder to be corrected at next D/D.
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 16 September 2009
Resolution: corrected
Electrical › Electrical Distribution System (service) › Junction Box
Issued 6 January 2006 Resolved
Provide junction box cover IWO control panel in the pilot house.
Action required: 705 - Other - as specified
Due 31 January 2006
Resolved 11 January 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 January 2006 Resolved
Owner/operator failed to schedule periodic exam within 3 months after COI anniversary date.
Due 6 January 2006
Resolved 6 January 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 January 2006 Resolved
Replace port & stbd entry way railing w/wire cable or equivalent
Due 31 January 2006
Resolved 3 February 2006
Communications › Radio Communications › EPIRB
Issued 16 December 2004 Resolved
Renew battery and hydrostatic release unit for 406 MHz EPIRB.
Action required: 705 - Other - as specified
Due 16 December 2004
Resolved 16 December 2004
Communications › Visual Communication
Issued 16 December 2004 Resolved
Stencil "Emergency Exit, Keep Clear" on galley and engine room escapes.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2004
Resolved 16 December 2004
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 16 December 2004 Resolved
Install proper size flex hose on suction side of sewage discharge pump.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2004
Resolved 16 December 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 16 December 2004 Resolved
Properly mount B-II portable fire extinguisher outside aft salon door.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2004
Resolved 16 December 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 December 2004 Resolved
Properly mount bilge high water alarm float switch in compartment below galley.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2004
Resolved 16 December 2004
Fire Fighting › Fire Hydrants › Condition
Issued 16 December 2004 Resolved
Repair or replace gate valves at fire hose stations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2004
Resolved 16 December 2004
Communications › Visual Communication
Issued 16 December 2004 Resolved
Stencil door from accommodation space to engine room IAW 46CFR185.610.
Action required: 705 - Other - as specified
Due 16 December 2004
Resolved 16 December 2004
Stability › Watertight Integrity
Issued 16 December 2004 Resolved
Adjust water tight scuttle from engine room to main deck to close properly.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2004
Resolved 16 December 2004
Fire Fighting › Fire Main
Issued 16 December 2004 Resolved
Repair broken brackets for firemain piping in engine room.
Action required: 705 - Other - as specified
Due 16 December 2004
Resolved 16 December 2004
Engineering › Lubricating Oil Storage/Transfer System › Gauge
Issued 16 December 2004 Resolved
Install proper sight glass for lube oil storage tank in lazarette.
Action required: 705 - Other - as specified
Due 16 December 2004
Resolved 16 December 2004
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 16 December 2004 Resolved
Provide non-conductive matting for deck at main distribution panel.
Action required: 705 - Other - as specified
Due 16 December 2004
Resolved 16 December 2004
Electrical › Electrical Distribution System (service) › Switchboard
Issued 16 December 2004 Resolved
Install proper safety device on main distribution panel to prevent accidentally energizing of shore tie and ships generator simultaneously.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 December 2004
Resolved 16 December 2004
Engineering › Compressed Air System (start air)
Issued 16 December 2004 Resolved
Conduct hydrostatic testing of air receivers iaw 46 CFR 61.10(d). LEGACY COMPONENT DESC: Receiver/Bottle
Action required: 705 - Other - as specified
Due 16 December 2004
Resolved 16 December 2004
Lifesaving › Lifefloat › Float Free
Issued 30 November 2004 Resolved
Provide float free arrangement for lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2004
Resolved 30 November 2004
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 30 November 2004 Resolved
Replace/repair MSD (sewage tank) fixing associated leaks/holes as necessary.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 7 December 2004
Lifesaving › Buoyant Apparatus › Readily Accessible
Issued 30 November 2004 Resolved
Remove items being stored in area of lifefloat lauching areas.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 7 December 2004
Engineering › Freshwater Generation System › Pump
Issued 30 November 2004 Resolved
Mount fresh water pump located in area next to MSD storage tank.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 7 December 2004
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 30 November 2004 Resolved
Provide means of securing MSD overboard discharge valve in closed position.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 7 December 2004
Fire Fighting › Fire Hoses › Condition
Issued 30 November 2004 Resolved
Renew starboard fire hose.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 7 December 2004
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 30 November 2004 Resolved
Provide tending line for crewman to use during man overboard drills.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 7 December 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 November 2004 Resolved
Remove/connect dead-end wiring located on starboard main engine.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 7 December 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 November 2004 Resolved
Provide non-expired aspirin for first aid kit.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 7 December 2004
Engineering › Steering Gear System › Rudder Stock
Issued 30 November 2004 Resolved
Reposition rudder stop on starboard rudder.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 22 December 2004
Lifesaving › Lifefloat › Paddle
Issued 30 November 2004 Resolved
Re-stencil name of vessel on L/F paddles.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 7 December 2004
Engineering › Bilge Water Management System › Strainer
Issued 30 November 2004 Resolved
Demonstrate clean overboard bilge suction.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 22 December 2004
Engineering › Pressure Vessel › Relief Valve
Issued 30 November 2004 Resolved
Renew/test pop-offs for both air receivers.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 7 December 2004
Resolution: Air receivers tested and both relieved @ 160 PSI and reset properly - tanks are rated at 200 PSI.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 25 September 2002 Resolved
Recharge/Renew portable fire extinguisher in pilot house.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 October 2002
Resolved 25 September 2002
Resolution: New extinguisher purchased and installed.
Engineering › Lubricating Oil Storage/Transfer System
Issued 25 September 2002 Resolved
Install proper sight glass gauge for lube oil storage tank in lazarette. LEGACY COMPONENT DESC: Gauge
Action required: 705 - Other - as specified
Due 25 October 2002
Resolved 8 January 2004
Fire Fighting › Fire Main
Issued 25 September 2002 Resolved
Repair broken brackets for fire main piping in engine room.
Action required: 705 - Other - as specified
Due 25 October 2002
Resolved 8 January 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 25 September 2002 Resolved
Stencil upper deck capacity at stair well leading to upper deck.
Action required: 705 - Other - as specified
Due 25 October 2002
Resolved 8 January 2004
Engineering › Compressed Air System (control)
Issued 25 September 2002 Resolved
Prove proper operation of safety relief valves on both air receivers. LEGACY COMPONENT DESC: Valve
Action required: 705 - Other - as specified
Due 25 October 2002
Resolved 30 October 2002
Resolution: Witnessed satisfactory operational test of safety relief valves on both engine room air receivers.
Engineering › Shafting/Propeller Arrangements
Issued 12 September 2002 Resolved
Renew cutlass bearing on Port Shaft. LEGACY COMPONENT DESC: Bearing
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 17 September 2002
Construction/Loadline › Hull
Issued 12 September 2002 Resolved
Crop and renew hull plating around starboard exhaust penetration on transom. LEGACY COMPONENT DESC: Hull Plating
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 19 September 2002
Resolution: 18" X 18" insert and new section of exhaust piping installed.
Communications › Alarms/Indicators
Issued 12 September 2002 Resolved
Replace wiring for bilge high water alarms with marine grade wiring. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2002
Resolved 19 September 2002
Engineering › Compressed Air System (control)
Issued 12 September 2002 Resolved
Remove flake rust on port air receiver.
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 17 September 2002
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 12 September 2002 Resolved
Reroute cooling line for port engine exhaust colling supply and renew flex hose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2002
Resolved 17 September 2002
Engineering › Bilge Water Management System
Issued 12 September 2002 Resolved
Renew broken section of fore peak bilge suction line at forward bulkhead in bilge below galley. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2002
Resolved 19 September 2002
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 12 September 2002 Resolved
Install missing screws in electrical cover for hot water heater switch box.
Action required: 705 - Other - as specified
Due 30 September 2002
Resolved 17 September 2002
Operations/Management › Pollution › Control of Garbage
Issued 31 October 2001 Resolved
Vessel operator was not keeping a trash disposal log iaw 33 CFR 151. Provide added section to vessel log to begin logging after each charter trip.
Due 30 November 2001
Resolved 2 November 2001
Resolution: Provided added section to vessel log.
Lifesaving › Hand Flares
Issued 31 October 2001 Resolved
Vessel operator did not have proper red hand held pyrotechnic flares. Flares on board were for recreational vessel's only. Provide proper red hand held flares.
Due 30 November 2001
Resolved 2 November 2001
Resolution: Provided proper red hand held flares.
Communications › Audible Communications
Issued 31 October 2001 Resolved
Emergency broadcast instructions were not easily available to the passengers in the event of an emergency. Provide and post emergency broadcast instructions in vicinity of VHF radio.
Due 30 November 2001
Resolved 3 November 2001
Resolution: Provided and posted emergency broadcast instructions in vicinity of VHF radio.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 31 October 2001 Resolved
The antenna wire for the GPS was run through the STBD weathertight door. Properly run antenna wire to preserve weathertight integrity.
Due 30 November 2001
Resolved 2 November 2001
Resolution: Secured antenna wire through weathertight means.
Communications › Audible Communications › Horn/Whistle
Issued 31 October 2001 Resolved
Horn bell above pilot house was broken off with jagged edges causing a personnel hazard. Repair broken horn.
Due 30 November 2001
Resolved 2 November 2001
Resolution: Repaired broken horn.
Communications › Audible Communications › Horn/Whistle
Issued 31 October 2001 Resolved
The public address speaker was mounted using lines from the lifefloat above the pilot house. Properly mount PA speaker.
Due 30 November 2001
Resolved 2 November 2001
Resolution: Properly mounted PA speaker.
Accommodation/Occupational Safety › Occupational Safety
Issued 31 October 2001 Resolved
The emergency escape hatch from the galley was not labeled on exterior "Emergency Exit, Keep Clear". Provide proper labeling on emergency escape hatch.
Due 30 November 2001
Resolved 2 November 2001
Resolution: Provided proper labeling on emergency escape hatch.
Accommodation/Occupational Safety › Occupational Safety
Issued 31 October 2001 Resolved
The dogs on the emergency escape hatch from galley were frozen from lack of maintenance. Provide proper operation of escape dogs.
Due 30 November 2001
Resolved 2 November 2001
Resolution: Provided proper operation of escape dogs.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 October 2001 Resolved
Dated material in the first aid kit had expired. Replace expired medication in first aid kit.
Due 30 November 2001
Resolved 2 November 2001
Resolution: Replaced expired medication in first aid kit.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 31 October 2001 Resolved
EPIRB hydrostatic release unit was past expiration date. Provide proper hydrostatic release unit.
Due 30 November 2001
Resolved 2 November 2001
Resolution: Provided proper hydrostatic release unit.
Lifesaving › Buoyant Apparatus
Issued 31 October 2001 Resolved
Painter for the port side lifefloat was not connected to a weaklink. Connect lifefloat to a weaklink.
Due 30 November 2001
Resolved 2 November 2001
Resolution: Connected lifefloat to a weaklink.
Lifesaving › Buoyant Apparatus
Issued 31 October 2001 Resolved
Painter for the starboard side lifefloat was securely bundled together with plastic wire ties. Remove wire ties to provide easy deployment.
Due 30 November 2001
Resolved 2 November 2001
Resolution: Removed wire ties to provide easy deployment.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 31 October 2001 Resolved
B-I fire extinguisher in the pilot house was not mounted. Properly mount fire extinguisher. LEGACY COMPONENT DESC: Mounting Bracket
Action required: 705 - Other - as specified
Due 30 November 2001
Resolved 2 November 2001
Resolution: Properly mounted fire extinguisher.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 31 October 2001 Resolved
Minor leak noted on port engine fuel line. Properly repair leak on fuel line.
Due 30 November 2001
Resolved 2 November 2001
Resolution: Properly repaired leak on fuel line.
Engineering › Fuel Oil Service System › Valve
Issued 31 October 2001 Resolved
Emergency fuel shut-off valve locations were not properly marked. Properly mark emergency fuel shut-off valves.
Due 30 November 2001
Resolved 2 November 2001
Resolution: Properly marked emergency fuel shut-off valves.
Engineering › Reduction Gearing/Clutches › Bolt
Issued 31 October 2001 Resolved
Securing nut for morse control cable on transmission control port engine found severely loose. Correct loose cable on morse control.
Due 30 November 2001
Resolved 2 November 2001
Resolution: Corrected loose cable on morse control.
Engineering › Fuel Oil Service System
Issued 31 October 2001 Resolved
Racor flame impingement bowl on generator was missing. Issued CG- 835 to provide proper flame impingement bowl. LEGACY COMPONENT DESC: Filter
Due 30 November 2001
Resolved 9 November 2001
Resolution: Provided proper flame impingement bowl.
Engineering › Compressed Air System (control)
Issued 31 October 2001 Resolved
Vessel operator not familiar with methods of testing safety relief valves on air receivers. Prove proper operation of air receiver safety relief valves. LEGACY COMPONENT DESC: Receiver/Bottle
Due 30 November 2001
Resolved 9 November 2001
Resolution: Proved proper operation of air receiver safety relief valves.
Electrical › Electric Supply System (service)
Issued 31 October 2001 Resolved
Wires connected to terminal block behind control console did not have proper crimp connectors. Provide proper crimp connectors. LEGACY COMPONENT DESC: Cable
Due 30 November 2001
Resolved 2 November 2001
Resolution: Provide proper crimp connectors.
Engineering › Bilge Water Management System › Manifold
Issued 31 October 2001 Resolved
Bilge manifold valves in engine room were not labeled to identify space served. Label bilge manifold valves.
Due 30 November 2001
Resolved 2 November 2001
Resolution: Labeled bilge manifold valves.
Engineering › Steering Gear System › Hydraulic Hose
Issued 31 October 2001 Resolved
Noted minor leakage on forward hydraulic line attached to hydraulic motor in lazarette. Repair leak on hydraulic line.
Due 30 November 2001
Resolved 2 November 2001
Resolution: Repair leak on hydraulic line.
Engineering
Issued 31 August 2000 Resolved
Repair as new port main engine inboard exhaust system in way of leak._x001C_ R
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Engineering
Issued 31 August 2000 Resolved
Repair as new lube oil supply lines to stboard main engine outboard turbo charger. Use "approved" hose as required by 46 CFR 182.720.
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Accommodation/Occupational Safety
Issued 31 August 2000 Resolved
Clean engineroom and lazarette bilges and make available for inspection.
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Engineering
Issued 31 August 2000 Resolved
Renew pedro connection in way of port main engine R/W cooling ovbd connection.
Condition: Unknown
Due 31 August 2000
Resolved 31 August 2000
Lifesaving
Issued 29 September 1999 Resolved
RENEW LIFE LINES ON FORWARD PORT AND STARBOARD RING BUOYS.
Condition: Unknown
Due 15 October 1999
Resolved 4 November 1999
Lifesaving
Issued 29 September 1999 Resolved
DESIGNATE IN WRITING AND PROVIDE ADEQUATE CPR TRAINING FOR THE SENIOR DECKHAND.
Condition: Unknown
Due 15 October 1999
Resolved 4 November 1999
Lifesaving
Issued 29 September 1999 Resolved
PROVIDE AND POST A SHIPS STATION BILL IN ACCORDANCE WITH 46 CFR 185.514.
Condition: Unknown
Due 15 October 1999
Resolved 4 November 1999
Lifesaving
Issued 29 September 1999 Resolved
REPLACE RETROREFLECTIVE TAPE ON 37 ADULT PFD'S. RESTRICTED TO CARRYING NO MORE THAN 121 PERSONS UNTIL COMPLETE.
Condition: Unknown
Due 15 October 1999
Resolved 4 November 1999
Lifesaving
Issued 29 September 1999 Resolved
REPLACE LIFE LINES, PENNANT LINES, PAINTER LINES, AND WATERLIGHT LINES ON ALL SIX LIFE FLOATS.
Condition: Unknown
Due 15 October 1999
Resolved 4 November 1999
Construction/Loadline
Issued 8 October 1998 Resolved
REPAIR BROKEN DOGGING DEVICE ON WATER TIGHT HATCH TO ENGIEROOM
Condition: Unknown
Due 8 October 1998
Resolved 8 October 1998
Engineering
Issued 8 October 1998 Resolved
REPAIR AS NEW MINOR OIL LEAK ON #3 (PORT) ENGINE INWAY OF OIL FILTER
Condition: Unknown
Due 8 October 1998
Resolved 8 October 1998
Engineering
Issued 8 October 1998 Resolved
REPAIR AS NEW WATER LEAKS ON CENTER MAIN ENGINE EXHAUST SYSTEM
Condition: Unknown
Due 8 October 1998
Resolved 8 October 1998
Lifesaving
Issued 8 October 1998 Resolved
ADD WORKABLE SHACKLE TO MAN OVBED HARNESS
Condition: Unknown
Due 8 October 1998
Resolved 8 October 1998
Engineering
Issued 8 October 1998 Resolved
REPAIR AS NEW ALL ENGINE ALARMS
Condition: Unknown
Due 8 October 1998
Resolved 8 October 1998
Electrical
Issued 8 October 1998 Resolved
REPLACE MISSING BREAKERS OR INSTALL BLANKS IN LAZARETTE POWER PANEL
Condition: Unknown
Due 8 October 1998
Resolved 8 October 1998
Navigation
Issued 8 October 1998 Resolved
HAVE ON BOARD UPDATED COPIES OF COAST PILOT, LIGHT LISTS FOR LOCAL AREA
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Electrical
Issued 8 October 1998 Resolved
MOUNT BATTERY UNDER OPERATING STATION AND ISOLATE EXPOSED WIRING
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Electrical
Issued 8 October 1998 Resolved
INSTALL COVER ON 110 VAC RECEPTICAL UNDER BRIDGE CONSOLE
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Electrical
Issued 8 October 1998 Resolved
INSTALL COVER ON LIGHT IN LAUNDRY ROOM
Condition: Unknown
Due 8 October 1998
Resolved 8 October 1998
Navigation
Issued 8 October 1998 Resolved
UPDATE CHARTS WITH LOCAL NTM'S
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Navigation
Issued 8 October 1998 Resolved
REPAIR AS NEW HYDRAULIC RAM ON STEERING SYSTEM (STBD RAM LEAKS)
Condition: Unknown
Due 8 October 1998
Resolved 8 October 1998
Accommodation/Occupational Safety
Issued 8 October 1998 Resolved
INSTALL HOSE CLAMP ON SEWAGE FLEX LINE FROM TOILET TO MSD TANK
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Lifesaving
Issued 8 October 1998 Resolved
REMOVE CARPET FROM MACHINERY SPACES
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Engineering
Issued 8 October 1998 Resolved
REPAIR AS NEW GUAGE CONSOLE ON BRIDGE IN WAY OF OVHD AT OPERATING STATION
Condition: Unknown
Due 8 October 1998
Resolved 8 October 1998
Fire Fighting
Issued 8 October 1998 Resolved
SHOW PROPER OPERATION OF FIRE PUMP
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Documentation
Issued 8 October 1998 Resolved
SHOW PROOF OF DRUG TESTING PROGRAM
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Lifesaving
Issued 8 October 1998 Resolved
MAKE TWO 12 PERSON LIFEFLOATS FLOAT FREE
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Electrical
Issued 8 October 1998 Resolved
INSTALL GUAGES IN ENCLOSURE IN WAY OF BRIDGE
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Electrical
Issued 26 August 1998 Resolved
REPAIR AS NEW LIGHT SWITCH BOX TO LIGHTING IN LOWER BUNK ROOM
Condition: Unknown
Due 27 August 1998
Resolved 27 August 1998
Electrical
Issued 26 August 1998 Resolved
INSTALL COVER ON COMPUTER IN LOWER BUNK ROOM OR REMOVE COMPUTER
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Engineering
Issued 26 August 1998 Resolved
RENEW OVBD PEDRO CONNECTION ON PORT MAIN ENGINE W/APPROVED HOSE
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Engineering
Issued 26 August 1998 Resolved
REBRACKET MORSE CONTROL CABE CONDUIT'S IN WAY OF ENGINERROM
Condition: Unknown
Due 27 August 1998
Resolved 27 August 1998
Lifesaving
Issued 26 August 1998 Resolved
BOLT DOWN WASHER/DRYER
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Lifesaving
Issued 26 August 1998 Resolved
INSTALL GUARD ON COUPLING TO SEWAGE PUMP
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Electrical
Issued 26 August 1998 Resolved
REMOVE TEMP WIRING TO COMPUTERS AND SUBMIT PLAN TO INSTALL PERM DEDICATED WIRING
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Construction/Loadline
Issued 26 August 1998 Resolved
REFASTEN STANCHION BOLTS TO STANCHION IN WAY OF FWD BUNK ROOM
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Electrical
Issued 26 August 1998 Resolved
INSTALL COVER TO GALLEY ELECTRICAL POWER PANEL
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Engineering
Issued 26 August 1998 Resolved
INSTALL FLAME SCREENS ON PORT AND STARBOARD F/O VENTS
Condition: Unknown
Due 27 August 1998
Resolved 27 August 1998
Accommodation/Occupational Safety
Issued 26 August 1998 Resolved
REMOVE ALL UN-USED GEAR ON BOAT AND ALL FIRE HAZARDS
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Electrical
Issued 26 August 1998 Resolved
INSTALL COVER TO LIGHT IN FWD BILGE
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Construction/Loadline
Issued 26 August 1998 Resolved
MAKE FWD GALLEY BILGE AVAILABLE FOR CLOSE UP INSPECTION, CLEAN BILGES AND MAKE FREE OF RAW SEWAGE
Condition: Unknown
Due 27 August 1998
Resolved 27 August 1998
Construction/Loadline
Issued 26 August 1998 Resolved
MAKE LAZARETTE BILGES AVAILABLE FOR CLOSE UP INSPECTION
Condition: Unknown
Due 27 August 1998
Resolved 27 August 1998
Lifesaving
Issued 26 August 1998 Resolved
RENEW AIR COMPRESSOR FLEXIBLE NON-METALLIC HOSE IN WAY OF PORT AIR RECEIVER
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Construction/Loadline
Issued 26 August 1998 Resolved
MAKE LAZARARETTE AND E/R FREE FROM OIL
Condition: Unknown
Due 27 August 1998
Resolved 27 August 1998
Electrical
Issued 26 August 1998 Resolved
INSTALL SHIELD ABOVE MOTOR CONTROLLOR PORT SIDE IN WAY OF ENGINEROOM ER VENTILATION CONTROLLOR
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Electrical
Issued 26 August 1998 Resolved
INSTALL COVER ON THERMOSTAT TO HW DOMESTIC HEATER
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Electrical
Issued 26 August 1998 Resolved
REMOVE UNUSED AND EXPOSED WIRING IN BUNK ROOM BILGE
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Construction/Loadline
Issued 26 August 1998 Resolved
REPAIR AS NEW FRACTURES IN WAY ON LONGS STBD SIDE BUNK ROOM
Condition: Unknown
Due 27 August 1998
Resolved 27 August 1998
Lifesaving
Issued 26 August 1998 Resolved
MOUNT HYDROPNEUMATIC F/W PUMP AND INSTALL HOSE USING GOOD MARINE PRACTICE
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Accommodation/Occupational Safety
Issued 26 August 1998 Resolved
REPAIR AS NEW MSD HOLDING TANK, CLEAN BILGES OF RAW SEWAGE
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Lifesaving
Issued 26 August 1998 Resolved
MARK LIFERING BUOY WITH VESSELS NAME PER 46 CFR 185.604(B)
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Engineering
Issued 26 August 1998 Resolved
PLUG F/O PRIMING LINE ON CENTER ENGINE
Condition: Unknown
Due 27 August 1998
Resolved 27 August 1998
Electrical
Issued 26 August 1998 Resolved
REMOVE ALL TWIST ON TYPE ELECTRICAL CONNECTIONS THROUGHOUT VESSEL
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Lifesaving
Issued 20 October 1995 Resolved
Perform U/W drills man overboard, fire drills, abandon ship, and loss of power drills.
Condition: Unknown
Due 28 November 1995
Resolved 28 November 1995
Lifesaving
Issued 20 October 1995 Resolved
Provide proper B/A stowage with proper weak links.
Condition: Unknown
Due 28 November 1995
Resolved 28 November 1995
Documentation
Issued 20 October 1995 Resolved
Establis drug testing program that complies with regs.
Condition: Unknown
Due 28 November 1995
Resolved 28 November 1995
Documentation
Issued 7 September 1995 Resolved
Accomplish outstanding comments of MSC letter dated 09MAY95 serial number H1-9501872 and MSO San Francisco letter dated 07JUL95, prior to the carriage of over 60 passengers.
Condition: Unknown
Due 7 September 1995
Resolved 7 September 1995
Documentation
Issued 31 October 1994 Resolved
Prior to a coastwise voyage, Provide a waste management plan.
Condition: Unknown
Due 31 October 1994
Resolved 31 October 1994
Lifesaving
Issued 31 October 1994 Resolved
Prior to a coastwise voyage, place retroreflective tape on ring buoys.
Condition: Unknown
Due 31 October 1994
Resolved 31 October 1994
Documentation
Issued 31 October 1994 Resolved
Prior to making a voyage beyond 1000 feet from shore, Post a valid radio station license.
Condition: Unknown
Due 31 October 1994
Resolved 31 October 1994
Accommodation/Occupational Safety
Issued 31 October 1994 Resolved
Repair the broken portside window in the passenger lounge.
Condition: Unknown
Due 31 October 1994
Resolved 31 October 1994
Accommodation/Occupational Safety
Issued 31 October 1994 Resolved
Mark location of children life preservers.
Condition: Unknown
Due 31 October 1994
Resolved 31 October 1994
Navigation
Issued 31 October 1994 Resolved
Provide a deviation card for compass.
Condition: Unknown
Due 31 October 1994
Resolved 31 October 1994
Engineering
Issued 31 October 1994 Resolved
Demonstrate proper operation of the starboard engine RPM gauge on the bridge.
Condition: Unknown
Due 31 October 1994
Resolved 31 October 1994
Navigation
Issued 31 October 1994 Resolved
Reposition mast navigational lights.
Condition: Unknown
Due 31 October 1994
Resolved 31 October 1994
Accommodation/Occupational Safety
Issued 31 October 1994 Resolved
Mark galley emergency exit - "Emergency Exit - Keep Clear" - both sides.
Condition: Unknown
Due 31 October 1994
Resolved 31 October 1994
Construction/Loadline
Issued 29 June 1994 Resolved
Remove oil from engineroom bilges prior to getting underway.
Condition: Unknown
Due 29 June 1994
Resolved 29 June 1994
Documentation
Issued 29 June 1994 Resolved
Provide a copy of vessel's hull guaging report.
Condition: Unknown
Due 29 June 1994
Resolved 29 June 1994
Navigation
Issued 29 June 1994 Resolved
Renew the starboard rudder bearing.
Condition: Unknown
Due 29 June 1994
Resolved 29 June 1994
Engineering
Issued 29 June 1994 Resolved
Clean sea suction supply pipe to starboard main engine.
Condition: Unknown
Due 27 July 1994
Resolved 27 July 1994
Engineering
Issued 29 June 1994 Resolved
Make permanent repair to temporary patch on the 1 1/2" fuel oil supply lineon portside tank.
Condition: Unknown
Due 29 June 1994
Resolved 29 June 1994
Construction/Loadline
Issued 20 November 1990 Resolved
FRACTURE WELDS IN BILGE UNDER PASS COMPT.
Condition: Unknown
Due 20 November 1990
Resolved 20 November 1990
Unknown
Issued 15 June 1989 Resolved
REPAIR/RENEW TO PROPER OPERATION INSTALLED RADIO STATION.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Unknown
Issued 12 September 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL RALPH JR. DN547447.
Condition: Unknown
Due 12 September 1983
Resolved 12 September 1983
Construction/Loadline
Issued 12 September 1983 Resolved
MAKE PERMANENT REPAIRS IN WAY OF CRACKED STARBOARD SIDE PLATE & COVERED OVERBOARD DISCHARGE HOLE.
Condition: Unknown
Due 12 September 1983
Resolved 12 September 1983
Documentation
Issued 12 September 1983 Resolved
POST CERTIFIED TRUE COPY OF STABILITY LETTER DATED 20JUN73 ON VESSEL.
Condition: Unknown
Due 12 September 1983
Resolved 12 September 1983

Casualty record · 1

13 March 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2313116
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

RACHEL G (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.