MAURY USCG vessel records
← All vessels

CAPTAIN GABE

CAPTAIN GABE is a 1973 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in June 2025, along with 30 deficiencies and 1 casualty investigation in 2005.

Records from 2005 to 2025. Most recent: inspection, 18 June 2025.

Built
1973
Last inspected
18 June 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 June 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE9278
Flag
UNITED STATES
Maury page id
psix-47508

Documentation record

Registered dimensions (L × B × D)85.1 ft × 21.0 ft × 8.8 ft
Registered tonnagegross 93 / net 73
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAMCRAFT INC · CROWN POINT, LA, UNITED STATES · built 1973
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 1 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
73 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

18 June 2025 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8126883
26 February 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8085144
25 July 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7967147
19 June 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7938252
23 August 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7785655
12 July 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7740863
14 April 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7668631
7 February 2023 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7633457
3 January 2023 Examination of Repairs · In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7616082
14 September 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7558918
3 August 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7278005
4 February 2021 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7135925
19 June 2020 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6979778
29 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6844844
6 August 2019 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6774449
7 February 2019 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6621502
11 July 2018 DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6475565
4 April 2018 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6389458
22 June 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6183224
25 March 2017 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6112863
2 August 2016 DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5960906

Deficiency record · 30

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 June 2025 Resolved
vessel must be provided with individual bilge lines and bilge suctions for each watertight compartment. The engine room, bilge suction was inoperable. Demonstrate bilge suction from the engine room, galley and berthing space. 46 CFR 182.510
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2025
Resolution: Witnessed operation, all sat
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 June 2025 Resolved
The port generator starting battery was found to be unsecured. Provide battery with proper securing device to prevent movement in all sea conditions. 46 CFR 183.354
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 June 2025
Resolution: Witnessed correction, all sat
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 June 2025 Resolved
The engine room escape scuttle was found with unreadable labeling. Provide hatch with “EMERGENCY EXIT, KEEP CLEAR” 46 CFR 185.606
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 June 2025
Resolution: Witnessed correction, all sat
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 June 2025 Resolved
Both fire hydrants were found without spanner wrenches. Provide each fire station with appropriate spanner wrenches. 46 CFR 181.310
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 June 2025
Resolution: Witnessed installation, all sat
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 June 2024 Resolved
Provide vessel with complete but simple instructions for the operation of the fixed CO2 system. Instructions can include steps like: make sure no persons are in the compartment, get captains permission, secure ventilation, secure fuel valves....etc.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2024
Resolved 9 July 2024
Resolution: Instructions were provided.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 19 June 2024 Resolved
Provide bunk room emergency escape with "KEEP CLEAR"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2024
Resolved 9 July 2024
Resolution: Labeling was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 June 2024 Resolved
Label upper adult life jacket storage with type (Adult) and quantity.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2024
Resolved 9 July 2024
Resolution: Labeling was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 June 2024 Resolved
Label Child life jacket storage with type (Child) and quantity.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2024
Resolved 9 July 2024
Resolution: Labeling was provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 June 2024 Resolved
Port generator was found with exposed wire nuts on two wires. Make connections permanent with crimped connections or provide junction box for wire nuts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2024
Resolved 9 July 2024
Resolution: Crimped connectors with heat shrink was installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 July 2023 Resolved
Fixed firefighting systems are required to conduct annual inspections by an approved party. Vessel fixed firefighting system found to be overdue for inspection. Provide service report.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2023
Resolution: Received servicing report. Servicing was conducted on 14 July 2023 by Global Fire.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2023 Resolved
Nonconducting mats or grating must be provided on the deck in front of each switchboard. Switchboard located in generator space found to be missing non-conductive matting. Install non conductive matting in front of switchboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2023
Resolved 14 July 2023
Resolution: Vessel acquired new matting.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 3 January 2023 Resolved
Each vessel certificated on an Oceans Route in cold water must provide IBA/life rafts with an aggregate capacity of 100% of persons permitted on board. One (01) life raft (25 man capacity) and mount detached from vessel while underway. Total personnel count reduced to fifty-five (55) until proper repairs are made and life raft mounted to it's original condition to the satisfaction of the CG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 16 March 2023
Resolution: Total person count reduced to fifty-five (55) until deficiency is rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2021 Resolved
Must secure Battery Boxes in lazerete space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2021
Resolved 18 August 2021
Resolution: Pic sent to attending MI...[name withheld]
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 19 June 2020 Resolved
Crew members missing proof of medical certificates. Must provide proof to CG Marine Inspectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2020
Resolved 16 July 2020
Resolution: Verified by email...[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Remove electrical strips in wheel house and install required junction boxes for navigation equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 2 December 2019
Resolution: Removed power strips.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Remove / Replace / Repair outlet marked "Bad" in galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 2 December 2019
Resolution: Outlet repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Replace / Repair switch for the main water heater.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2019
Resolved 2 December 2019
Resolution: Switch removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 30 January 2020
Resolved 14 August 2020
Resolution: Electrical plan has been submitted, reviewed, approved and filed...[name withheld]
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 August 2019 Resolved
Obtain valid FCC safety radio certificate.
Action required: 10 - Deficiency Rectified
Due 6 August 2019
Resolved 6 August 2019
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 6 August 2019 Resolved
Grease port fuel shut-off valve (wouldn't fully close).
Action required: 10 - Deficiency Rectified
Due 6 August 2019
Resolved 6 August 2019
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 August 2019 Resolved
Replace non-CG approved life buoys.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2019
Resolved 20 August 2019
Resolution: Replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 6 August 2019 Resolved
Replace life float (no longer serviceable). Total persons on board reduced to 80 until corrected.
Action required: 705 - Other - as specified
Due 5 September 2019
Resolved 22 August 2019
Resolution: Removed & COI amended to reduce pax
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 August 2019 Resolved
Provide pressure vessel relief valve setting and pressure gauge calibration report.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2019
Resolved 22 August 2019
Resolution: Pressure vessel removed and COI amended.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 August 2019 Resolved
Correct dead-end wiring found above center MDE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2019
Resolved 20 August 2019
Resolution: Cables removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 August 2019 Resolved
Replace broken gauge on hydraulics on fwd anchor winch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2019
Resolved 20 August 2019
Resolution: Gauge replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 11 July 2018 Resolved
Provide marking for forward emergency exit on exterior of vessel in 2 inch lettering "Emergency Exit, Keep Clear".
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 31 July 2018
Resolution: Emergency exit marking provided.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 11 July 2018 Resolved
Make aft engine room/forward Laz bulkhead permanently watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2018
Resolved 31 July 2018
Resolution: Bulkhead perm watertight.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 April 2018 Resolved
Repair damaged rails located amidship on both port and starboard side.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2018
Resolved 11 April 2018
Resolution: Rails were properly welded.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2018 Resolved
Make proper repairs to damaged shore power cable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2018
Resolved 11 April 2018
Resolution: Shore power cable replaced.
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 March 2017 Resolved
Identify loss of propulsion and repair to satisfaction of attending CG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2017
Resolution: The failure was identified as non servicable batteries, new batteries have been installed.

Casualty record · 1

13 March 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2313116
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

RACHEL G (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.