MAURY USCG vessel records Sign in
← All vessels

OCEAN INTERVENTION

OCEAN INTERVENTION is a 1998 offshore supply vessel. The Coast Guard has recorded 58 inspections since 1998, most recently in February 2026, along with 47 deficiencies and 4 casualty investigations between 2007 and 2024.

Records from 1998 to 2026. Most recent: inspection, 13 February 2026.

Built
1998
Last inspected
13 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9203227 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCY4505
475112
Flag
UNITED STATES
366614000
Maury page id
psix-475112

Inspections, by type

…with no type recorded17
Years with a record 25 calendar years (1998–2026)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)221.3 ft × 54.0 ft × 19.0 ft
Registered tonnagegross 2,262 / net 678
ITC dimensions (L × B × D)221.3 ft × 54.0 ft × 19.0 ft
ITC tonnagegross 2,262 / net 678
BuilderOCEANEERING INTL INC · GIBSON LA · built 1998
Hull materialSteel
PropulsionDiesel Electric
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 30 January 2026 · expires 28 February 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2262 - Convention (Subpart B), Gross Ton
678 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY4505MMSI 366614000 · active · compulsorily equipped · granted 12 April 2018, expires 13 June 2028
WCY4505MMSI 366614000 · cancelled · voluntarily equipped · granted 11 April 2008, cancelled 12 June 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 58

13 February 2026 Periodic Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8313577
6 January 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8290461
19 February 2025 MTSA/ISPS Verification · Administrative Inspection · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8077711
27 September 2024 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8016507
26 June 2024 Administrative Inspection · In-Service Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7943272
25 June 2024 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8044854
30 January 2024 Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7857644
1 February 2023 COI Inspection · MTSA/ISPS Verification · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7630154
27 May 2022 MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Activities Europe · Activity 7463793
20 December 2020 Drydock Exam · Damage Survey · Internal Structural Exam · Periodic Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7114505
19 December 2020 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7117205
25 September 2020 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7079553
8 July 2020 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7000341
6 July 2020 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6998396
23 January 2020 Ballast Water Examination · MARPOL Annex I Examination · MTSA/ISPS Verification · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6895189
27 March 2019 Annual Inspection · Administrative Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6639767
26 February 2018 COI Inspection · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6361594
12 January 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6336768
7 November 2016 MARPOL Annex VI Survey · Annual Inspection · Administrative Inspection · MTSA/ISPS Verification · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6038666
9 December 2015 Administrative Inspection · Deficiency Check · MTSA/ISPS Verification · MARPOL Annex VI Survey · COI Inspection · ISM Oversight · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5775753
23 November 2015 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5777860
18 September 2015 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5747281
5 January 2012 Annual Inspection · Hull Examination · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4219310
11 January 2011 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3924774
25 January 2010 MTSA Verification · Re-Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3668052
12 May 2009 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3473017
27 February 2009 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3424940
28 January 2009 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3401958
13 November 2008 Administrative Inspection · MTSA Verification · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3362357
11 June 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3234610
17 January 2008 MARPOL Annex I Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3132717
9 June 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2956398
1 September 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2781896
28 May 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2672488
8 November 2005 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2530575
14 February 2005 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2291998
20 January 2004 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1988958
6 January 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1977035
12 November 2003 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1946450
23 January 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1734242
19 March 2002 Inclining Experiment
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1602289
19 March 2002 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1603780
13 February 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1486028
7 August 2001 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431072
28 June 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 188084
19 June 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 82982
17 June 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 22332
6 February 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1058250
19 October 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 823395
20 September 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1054011
22 August 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2599
7 July 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1051764
9 December 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 812307
30 November 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410117
18 November 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446846
6 May 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1128582
16 November 1998 Construction Oversight · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1368909
18 October 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 70608

Deficiency record · 47

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 February 2025 Resolved
The marine employer must have a sufficient number of urine-specimen collection and shipping kits meeting the requirements of 49 CFR part 40 that are readily accessible for use following Serious Marine Incidents (SMI); the specimen collection and shipping kits need not be carried on board each vessel if obtaining the kits and collecting the specimen can be completed within 32 hours from the time of the occurrence of the SMI. The vessel does not have collection and shipping kits on board, and its current route and operations would at times be at a greater distance than would allow for shore-side testing within 32 hours.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2025
Resolved 8 March 2025
Resolution: Received email from vessel Master showing that drug testing specimen kits had been obtained by the vessel.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 15 February 2024 Resolved
All ships of 400GT and above shall comply with the provisions of MARPOL ANNEX VI (air & energy pollution). From 01JAN2023, all ships shall calculate their attained Energy Efficiency Existing Ship index (EEXI) to measure their energy efficiency. No evidence of EEXI calculations were found onboard. Management to engage with Classification Society (ABS) for submittal and approval of EEXI calculations & re-issuance of IEEC to capture new MARPOL ANNEX VI requirements. 78MARPOL(2017)VI/19.1 78MARPOL(2017)VI/22.1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 February 2024
Resolution: IEEC and supplement issued to boat, EEXI exempt per non-conventional propulsion (diesel electric)
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 27 May 2022 Resolved
If an inspection, or examination under section 3308 of this title, reveals that a life preserver, lifesaving device, or firehose is defective and incapable of being repaired, the owner or master shall destroy the life preserver, lifesaving device, or firehose in the presence of the official conducting the inspection or examination. During the pressure test of the fire hose, 01 was found defective. 46 USC 3305(b)
Action required: 10 - Deficiency Rectified
Due 28 May 2022
Resolved 28 May 2022
Resolution: Fire hose was replaced and bad fire hose was destroyed in the presence of a Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 May 2022 Resolved
There shall be at least two means of escape from all general areas accessible to the passengers if carried, or where the crew may be quartered or normally employed. At least one of these two means of escape shall be independent of watertight doors. One emergency exit in the portable module on the aft deck was stuck. 46 CFR 92.10-5(a)
Action required: 10 - Deficiency Rectified
Due 28 May 2022
Resolved 28 May 2022
Resolution: The door was serviced and found in proper working order.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 14 April 2021 Resolved
Where the general emergency alarm signal cannot be heard over the background noise, there must be a red-flashing light or rotating beacon, in addition to the general emergency alarm signal, that: (2)Is activated whenever the general emergency alarm signal in the space are activated. Machinery space emergency red-flashing light was inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2021
Resolved 20 April 2021
Resolution: Witnessed satisfactory repair of machinery space general emergency alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 April 2021 Resolved
Test procedure documents must be in a step-by-step or checkoff list format. Each test instruction must specify equipment status, apparatus necessary to perform the tests, safety precautions, safety control and alarm set points, the procedure to be followed, and the expected test result. Test instruction for tests to be conducted on two bilge alarms and the generator reverse power relay were missing. Additionally, the generator prime mover lube oil pressure "low" test instructions did not match the approved PSTPs test instructions. Resubmit the revised PSTPs test instructions incorporating all the changes found during testing for review and approval to MSC.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2021
Resolved 19 April 2023
Resolution: PSTP's updated.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 January 2021 Resolved
Unless one or more extensions are authorized by the Commandant (CG-CVC), each OSV must be placed in drydock or hauled out for examination twice each 5 years with no interval between examinations exceeding 3 years. The internal structural members of an OSV must be examined at the same intervals required for drydocking by paragraph (a) of this section. Vessel's drydock and internal structural exams were due 23 November 2020 as indicated on their COI dated 23 April 2018, and the vessel has not completed either exam as of 07 January 2021. 46 CFR 126.140(a)&(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2021
Resolution: Vessel completed credit drydock and ISE.
01 - Certificates & Documentation › 013 - Documents › SAR co-operation plan for pass. ships on fixed trade
Issued 20 December 2020 Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer In Charge of Marine Inspection. Vessel experienced failure of #3 Main Generator resulting in damage to the generator and surrounding area and systems. Provide survey of damage, repair proposal and once approved by the OCMI, complete repairs to the satisfaction of the OCMI. 46 CFR 91.45-1 (a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2021
Resolution: Vessel repairs completed satisfactory.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 12 January 2018 Resolved
Retro-reflective tape on all lifejackets is cracked/faded. Replace all tape on all jackets.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 12 February 2018
Resolved 23 April 2018
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 January 2018 Resolved
Retro-reflective tape on all ring buoys is cracked/faded/soiled. Replace all tape on all ring buoys.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 12 February 2018
Resolved 23 April 2018
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 12 January 2018 Resolved
Remove aluminum paint locker from deck. Paint locker must be of steel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 November 2018
Resolved 23 April 2018
Electrical › Electric Generation Source (service) › Generator
Issued 7 November 2016 Resolved
Repair and prove proper operation of the #2 generator (910 KW) to the satisfaction of the attending American Bureau of Shipping (ABS) Surveyor prior to conducting operations.
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 21 November 2016
Resolution: ABS Recommendation issued for ABS Surveyor to verify proper repair to the No. 2 Auxiliary Generator to the satisfaction of the attending surveyor by next annual machinery survey (31Jan2018). No impact on DP-2 or vessel maneuverability.
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 7 November 2016 Resolved
Provide onboard approved Periodic Safety Test Procedures required by 46 CFR 62.20-1. (46 CFR 61.40).
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 23 April 2018
Fire Fighting › Structural - A Class Divisions › Doors
Issued 9 December 2015 Resolved
Provide doors fitted in category-A machinery space boundary bulkheads of engine room with self-closing devices per SOLAS 74 (1997) II-2/47. Vessel restricted from conducting international voyage until corrected to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 December 2016
Resolved 23 April 2018
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 November 2005 Resolved
Relabel all ruel reach rods on main deck.
Due 8 December 2005
Resolved 25 January 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 8 November 2005 Resolved
Provide 18 spare charges.
Due 8 December 2005
Resolved 25 January 2007
Lifesaving › Lifebuoys › Serviceable
Issued 8 November 2005 Resolved
Renew 5 life rings rings prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2006
Fire Fighting › Ventilation Systems
Issued 12 November 2003 Resolved
PRIOR TO 09JAN04, MAKE REPAIRS TO 03 FIRE DAMPERS IN FORWARD MACHINERY SPACE AND BOW THRUSTER ROOM. LEGACY COMPONENT DESC: fire dampers
Condition: Improper/Lack of Maintenance
Due 20 January 2004
Resolved 20 January 2004
Resolution: Rcvd faxed ABS survey report.
Deck/Cargo › Towing
Issued 23 January 2003 Resolved
RENEW 3 HYDRAULIC HOSES ON A FRAME UNIT ON AFT MAIN DECK HYDRAULIC SYSTEM ON PORT AND STARBOARD SIDES. LEGACY COMPONENT DESC: HYDRAULIC HOSES
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 February 2003
Resolved 30 January 2003
Resolution: ALL FOUR HOSES RENEWED USING CERTIFIED ABS HOSES.
Stability › Watertight Integrity
Issued 23 January 2003 Resolved
RENEW WATERTIGHT GASKET ON WATERTIGHT DOOR LEADING TO DRY STORES VOID SPACE. LEGACY COMPONENT DESC: DOOR
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2003
Resolved 30 January 2003
Resolution: RENEWED GASKET ON WATER TIGHT DOOR.
Lifesaving › Line-Throwing Appliances
Issued 23 January 2003 Resolved
PROVIDE 4 ROCKET IMPULSE GUNS AS PER SOLAS REQUIREMENTS. LEGACY COMPONENT DESC: Projectiles
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2003
Resolved 30 January 2003
Resolution: PROVIDED 4 ROCKET IMPULSE GUNS, TRAINED CREW ON HOW TO USE IMPULSE GUN.
Pollution Prevention/Response › Prevention Equipment
Issued 23 January 2003 Resolved
PROVIDE OPERATIONAL OILY WATER SEPARATOR. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 23 February 2003
Resolved 30 January 2003
Resolution: TEST RAN OILY WATER SEPARATOR, TEST SAT.
Electrical › Electrical Distribution System (service)
Issued 23 January 2003 Resolved
REPAIR REMOTE SHUTDOWN ON CLEAN LUBE OIL PUMP IN ENGINEROOM. LEGACY COMPONENT DESC: Switch
Action required: 705 - Other - as specified
Due 23 February 2003
Resolved 30 January 2003
Resolution: PUMP HAS REMOTE SHUTDOWN IN TH EOC.
Engineering › Fuel Oil Service System
Issued 23 January 2003 Resolved
PROVIDE METALLIC PLUGS FOR ALL RACOR UNITS IN ENGINEROOM. LEGACY COMPONENT DESC: Filter
Action required: 17 - Rectify deficiencies prior to departure
Due 23 February 2003
Resolved 30 January 2003
Resolution: PROVIDED PLUGS FOR ALL RACOR UNITS IN THE ENGINEROOM.
Navigation › Collision/Grounding Avoidance
Issued 13 February 2002 Resolved
DEMONSTRATE PROPER OPERATION OF THE RECORDING CAPABILITIES OF THE VESSELS DEPTH RECORDER IAW 33CFR164.35 LEGACY COMPONENT DESC: Echo-sounding Device Recorder
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 March 2002
Resolved 19 April 2002
Engineering › Generator (propulsion/auxiliary-electric)
Issued 13 February 2002 Resolved
DEMONSTRATE PROPER OPERATION OF BOTH O/B MAIN PROPULSION GENERATOR OVERSPEED AND OVERCURRENT PROTECTION DEVICES. LEGACY COMPONENT DESC: Overcurrent Devices Circuitry
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2002
Resolved 19 April 2002
Fire Fighting › Structural - Main Vertical Zones
Issued 13 February 2002 Resolved
CONDUCT MAINTENANCE ON BOTH STACK EXHAUST DAMPERS TO ALLOW COMPLETE CLOSURE LEGACY COMPONENT DESC: DAMPERS
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 February 2002
Resolved 13 February 2002
Construction/Loadline › Structures
Issued 13 February 2002 Resolved
PRIOR TO SAILING CONDUCT MAINTENANCE ON THE MAIN DECK SUPERSTRUCTURE ENTERANCE WATERTIGHT DOOR, THE ENG CONTROL STATION WATERTIGHT DOOR, AND THE CHANGE GASKET ON THE AFT ENG CONTROL STATION WATERTIGHT DOOR.. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 February 2002
Resolved 13 February 2002
Electrical › Electrical Distribution System (service) › Panelboard
Issued 13 February 2002 Resolved
INSTAL BREAKER BLANKS IN ELECTRICAL PANEL L7 FWD AUX MACH FLAT
Condition: Improper/Lack of Maintenance
Due 13 February 2002
Resolved 13 February 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 13 February 2002 Resolved
STENCIL ENG ROOM EMERGENCY ESCAPE. LEGACY COMPONENT DESC: MARKINGS
Due 13 February 2002
Resolved 13 February 2002
Engineering › Steering Gear System
Issued 13 February 2002 Resolved
PRIOR TO SAILING PROVIDE AND POST AT THE PILOT HOUSE AND EMERGENCY STEERING STATIONS PROPER EMERGENCY STEERING INSTRUCTIONS. LEGACY COMPONENT DESC: INSTRUCTIONS
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 13 February 2002
Resolved 13 February 2002
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 13 February 2002 Resolved
REMOVE ALL EXPIRED CHEMICAL LIGHTS FROM ALL PFDS
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 February 2002
Resolved 13 February 2002
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 13 February 2002 Resolved
PROPERLY SECURE CENTER WASHER AND DRYER, AND PORT SIDE DRYER.
Condition: Improper Installation
Due 13 February 2002
Resolved 13 February 2002
Engineering › Steering Gear System
Issued 13 February 2002 Resolved
INSTALL CHAFING GEAR ON THE PORT "Z" DRIVE MOTOR ELECTRICAL CABLES LEGACY COMPONENT DESC: HYDRAULIC HOSES
Condition: Improper/Lack of Maintenance
Due 13 February 2002
Resolved 13 February 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 13 February 2002 Resolved
INSTALL GUARDS ON THE CENTER SHAFTS FOR THE PORT AND STBD "Z" DRIVE MOTORS. LEGACY COMPONENT DESC: GUARDS
Condition: Improper Installation
Due 13 February 2002
Resolved 13 February 2002
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 February 2002 Resolved
INSTALL COVER ON JUNCTION BOX ABOVE "Z" DRIVE MOTORS.
Condition: Improper Installation
Due 13 February 2002
Resolved 13 February 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 13 February 2002 Resolved
REMOVE ALL PAINT FROM STBD MAIN DECK CO2 LOCKER AND PROPERLY STORE LEGACY COMPONENT DESC: LOCKER
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 13 February 2002
Resolved 13 February 2002
Personnel › Certificates/Documents/Licenses
Issued 13 February 2002 Resolved
PROVIDE PROPER STCW CERTIFICATES FOR CREW PRIOR TO CONDUCTING AN INTERNATIONAL VOYAGE
Due 13 February 2002
Resolved 13 February 2002
Unknown
Issued 7 August 2001 Resolved
As per 46 CFR 54.01-5 (e) provide plans certified by a professional engineer for the following pressure vessels: SN 265357, 265358, and 246827 to the satisfaction of an attending marine inspector.
Condition: Unknown
Due 7 August 2001
Resolved 7 August 2001
Documentation
Issued 7 July 2000 Resolved
Submit plans to G-MSC for review/approval under 46CFR Subpart "I".
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Documentation
Issued 7 July 2000 Resolved
Submit necessary information for automation QFA/DVT, 46CFR Subpart 62, to G-MSC for review/approval._x001C_
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000
Deck/Cargo
Issued 30 November 1999 Resolved
PROVIDE APPROVED PLANS FOR A-FRAME.
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Lifesaving
Issued 30 November 1999 Resolved
PROVIDE LABEL PLATE TO SHOW RESCUE BOAT DAVIT IS SOLAS APPROVED. ATTACH LABEL PLATE TO DAVIT.
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Fire Fighting
Issued 30 November 1999 Resolved
PROVIDE APPROVED PLANS FOR FIRE DOOR CLOSURES.
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Unknown
Issued 30 November 1999 Resolved
COMPLETE INSTALLATION OF DIVE AIR SYSTEM. PROVIDE APPROVED PLANS. HYDRO PIPE SYSTEM AFTER COMPLETION OF SYSTEM TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR. SYSTEM IS NOT TO BE USED UNTIL ABOVE REQUIREMENT COMPLETE.
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Deck/Cargo
Issued 16 November 1998 Resolved
02. REDUCE FLEXIBLE HOSE LENGTHS OF HYDRAULIC POWER UNIT LOCATED IN STARBOARD DECK LOCKER, TO LESS THAN 30".
Condition: Unknown
Due 16 November 1998
Resolved 16 November 1998
Engineering
Issued 16 November 1998 Resolved
01. PROVIDE APPROVED PRESSURE VESSEL PLANS REVIEWED BY REGISTERED PROFESSIONAL ENGINEER IN ACCORDANCE WITH 46 CFR 54.01 (e).
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 13 February 2002
Resolution: PRESSURE VESSEL PLANS OBTAINED AND FORWARDED WITH CASE

Casualty record · 4

9 June 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2956398
1 March 2013Routine · role: Acknowledged Pollution Source · activity 4541643
19 December 2020Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7117205
25 June 2024Routine · role: Involved in a Marine Casualty · activity 8044854
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.