← All vessels
GRANDE MARINER
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Northeast District (CGD-NE) · Other hulls named GRANDE MARINER
GRANDE MARINER is a 1998 passenger vessel (inspected). The Coast Guard has recorded 95 inspections since 1998, most recently in July 2026, along with 67 deficiencies, 1 operational control and 19 casualty investigations between 2006 and 2018.
Records from 1998 to 2026. Most recent: inspection, 17 July 2026.
- Built
- 1998
- Last inspected
- 17 July 2026
- Documentation
- Case Pending · documentation file of 10 September 2026
- Deficiencies
- 67 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 19 investigations · 2006–2018
Identity
1066911
WDP5465
475167
Flag
UNITED STATES
368363680, 369024000
Maury page id
psix-475167
Inspections, by type
…with no type recorded20
Years with a record
25 calendar years (1998–2026)
The 95 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)146.8 ft × 39.0 ft × 10.0 ft
Registered tonnagegross 97 / net 72
ITC dimensions (L × B × D)146.8 ft × 39.0 ft × 10.0 ft
ITC tonnagegross 829 / net 248
BuilderBLOUNT INDUSTRIES, INC. · WARREN, RI, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationCase Pending · issued 2 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
829 - Convention (Subpart B), Gross Ton
72 - Regulatory (Subpart C or D), Net Ton
248 - Convention (Subpart B), Net Ton
829 - Convention (Subpart B), Gross Ton
72 - Regulatory (Subpart C or D), Net Ton
248 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDP5465MMSI 368363680 · active · compulsorily equipped · granted 23 April 2024, expires 23 April 2034
WCY6594MMSI 369024000 · active · compulsorily equipped · granted 27 June 2018, expires 27 August 2028
EX221MMSI 369024000 · expired · exemption · granted 18 April 2016, cancelled 18 April 2020
EX156MMSI 369024000 · expired · exemption · granted 2 February 2012, cancelled 5 March 2016
EX79MMSI 369024000 · expired · exemption · granted 22 November 2004, cancelled 5 December 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 95
17 July 2026
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8440352
7 January 2026
Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8289474
3 December 2025
In-Service Inspection · Plan Review (Other than "T")
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8276657
22 March 2024
Internal Structural Exam · Plan Review (Other than "T") · Drydock Exam · In-Service Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7982541
22 September 2020
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7063045
12 February 2020
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6914254
6 December 2019
MARPOL Annex IV Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6869017
28 October 2019
COI Inspection · Internal Structural Exam · Examination of Repairs · MTSA/ISPS Verification · Administrative Inspection · Deficiency Check · DAPI Audit · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6848461
16 October 2019
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6835490
19 September 2019
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6827188
10 September 2019
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6808230
14 December 2018
COI Inspection · DAPI Audit · Deficiency Check · MTSA/ISPS Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6597793
20 November 2018
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6575477
24 October 2018
ISM SMC Audit
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6568866
26 September 2018
In-Service Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6549579
11 April 2018
Damage Survey
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6423294
10 April 2018
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6411240
10 April 2018
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6611200
9 February 2018
Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6353860
5 February 2018
Administrative Inspection · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6349487
7 December 2017
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6320120
30 November 2017
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6318804
3 November 2017
COI Inspection · Internal Structural Exam · Drydock Exam · DAPI Audit · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6301774
22 October 2017
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6294869
21 July 2017
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6219326
21 December 2016
Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6060978
26 October 2016
DAPI Audit · ISM Oversight · COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6030261
23 September 2016
ISM Oversight
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6009392
6 July 2016
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5931554
9 December 2015
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5773886
19 November 2015
COI Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5763048
28 October 2014
Examination of Repairs · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5013518
27 October 2014
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5012852
24 July 2012
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4395802
24 July 2012
In-Service Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4396505
7 May 2012
MARPOL Annex I Examination · DAPI Audit · COI Inspection · Plan Review (Other than "T") · MARPOL Annex VI Survey · MTSA/ISPS Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4294838
19 December 2011
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4227463
11 November 2010
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3931533
26 October 2010
Plan Review (Other than "T") · Construction Oversight · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3875390
17 September 2010
Deficiency Check · Damage Survey
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3851991
17 September 2010
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3853647
16 September 2010
ISM Oversight
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3856274
30 July 2009
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3550324
16 July 2009
Type not recorded
No type recorded · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 3536403
3 July 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3701812
5 May 2009
COI Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3435560
14 April 2009
In-Service Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3454577
16 December 2008
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3381789
20 November 2008
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3366498
27 October 2008
Administrative Inspection · ISM Oversight
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3354130
18 August 2008
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3302904
17 June 2008
Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3239651
11 June 2008
ISM Oversight
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3234558
25 April 2008
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3191962
23 April 2008
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3491361
10 January 2008
Damage Survey
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3128903
3 December 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3108717
10 November 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3097791
19 October 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3061471
22 June 2007
Administrative Inspection
Administrative · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2970047
14 June 2007
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2961742
10 June 2007
MTSA/ISPS Verification
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2961144
15 May 2007
MARPOL Annex I Examination · Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2929960
26 August 2006
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2761820
16 August 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2819748
27 July 2006
ISM Oversight
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2748640
16 June 2006
MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2681381
15 May 2006
COI Inspection · MTSA/ISPS Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2616477
1 December 2005
Examination of Repairs
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2544750
4 November 2005
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2528182
12 May 2005
MTSA/ISPS Verification · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2354061
29 April 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2345556
7 March 2005
Hull Examination · Construction Oversight
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2305173
2 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2302207
28 September 2004
ISM Oversight
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2207222
12 August 2004
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2174956
10 August 2004
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2161715
9 July 2004
MTSA Verification
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2127420
25 June 2004
MTSA/ISPS Verification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2110341
10 June 2004
COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2094667
16 May 2003
COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1794282
10 September 2002
In-Service Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1733981
12 June 2002
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1629087
9 May 2002
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1601107
8 November 2001
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 772536
16 August 2001
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1069022
14 June 2001
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1429579
10 May 2001
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1433854
19 May 2000
Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1361574
9 July 1999
Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1464930
26 January 1999
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 789693
28 December 1998
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 56680
14 December 1998
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 808219
9 November 1998
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 805601
25 June 1998
Deadweight Survey · Hull Examination · Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 792721
Deficiency record · 67
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 7 January 2026
Resolved
Each survival craft must be (b) stowed so that when the vessel sinks the survival craft floats free and, if inflatable inflates automatically. MI observed IBA rigged improperly rendering hydrostatic release inoperable and missed service dates. Remove or service.
46 CFR 117.130
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 January 2026
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date (1) Charts of large enough scale to make safe navigation possible. MI observed no nautical charts on board subject vessel.
46 CFR 121.420
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 20 December 2024
Resolved
2.4 Serial Communication Failure was unable to be successfully preformed during design verification test procedures. Repair and demonstrate in presence of CG MI within 14 day.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 December 2024
Resolved
Provide proof of approved first aid kit on board.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 November 2019
Resolved
High water bilge alarm in bow thruster room. Non operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 November 2019
Resolved
Old AC wire to hot water dead end. Grey water transfer tear drop float function box pulled wire.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 November 2019
Resolved
Low voltage tank wire connections. Repair.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 7 November 2019
Resolved
Grey water cross over pipe. Repair/replace.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 28 October 2019
Resolved
Rudder angle indicator at emergency steering station not marked and degree of angle missing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 October 2019
Resolved
Duty MI received report of loss of STBD Main Engine during transit down the Hudson river with 68 POB.
Provide written causal analysis for failure of STBD Main engine. Complete permanent repairs to the satisfaction of CG Marine Inspector.
705C- PRIOR TO MOVEMENT
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 December 2018
Resolved
Smoke floats expired on bridge wings. Replace with new.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 December 2018
Resolved
Stenciled life rings faded name and homeport.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 December 2018
Resolved
Replaced wasted and improper sized fire extinguisher bracket.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 10 April 2018
Resolved
Proceed to Port of Palm Beach to conduct repairs to port MDE and conduct sea trial to the satisfaction of attending USCG Marine Inspector.
Engineering › Diesel Engine (propulsion-direct drive) › Seal
Issued 7 December 2017
Resolved
Port engine was discovered spraying out oil and immediately brought offline. Mechanic in route to identify issue.
Construction/Loadline › Hull › Bottom Plating
Issued 6 November 2017
Resolved
C/R P/S and S/S bottom plate adjacent to CVK, approximately 3' X 4' section, along with transom 2.5' X 8" section marked, located in steering flat.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 6 November 2017
Resolved
Address SFP items; Fwd Bow Thruster room, SS side passenger bulkhead, insulation missing. Engine room (5 locations total) in overhead, repair/install previously removed insulation.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 22 October 2017
Resolved
Vessel failed to submit an Advanced Notice of Arrival at least 24 hours before arriving at Warren, RI.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 4 November 2016
Resolved
Forpeak section, top of seachest, valve containted small pin hole below nipple causing leak.
Engineering › Bilge Water Management System › Piping
Issued 4 November 2016
Resolved
Bilge pipe penetrating WTB in forpeak totally wated and able to be struck with inpsection hammer causing holes.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 November 2016
Resolved
frame located at 1st bulkhead fwd of stern, stbd side adjacent to shaft tube, wasted and weld washed out.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 November 2016
Resolved
First frame fwd of stern steering compartment, centerline stbd side, approx 3" X 8" section wasted.
Engineering › Generator (propulsion-electric) › Reverse Power Protection Relay Circuitry
Issued 26 October 2016
Resolved
Make #2 ship service generator available for testing and inspection by attending Marine Inspector. Generator out of service due to rebuild, overspeed, reverse power relay and inspection needed.
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 23 September 2016
Resolved
Conduct internal audit on the Grande Mariner.
Operations/Management › Drills/Instruction › Not Conducted
Issued 19 November 2015
Resolved
Conduct drills underway with crew to include; fire, security and abandon ship.
Engineering › Generator (propulsion-electric) › Reverse Power Protection Relay Circuitry
Issued 19 November 2015
Resolved
Provide proof of paralleling of generators and functional testing of reverse power protection relays.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 19 November 2015
Resolved
Provide proof of FCC documents and servicing of equipment on navigational bridge. (Bridge-to-Bridge and Radio Telephony)
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 24 July 2012
Resolved
Prove proper operation of port main engine.
Communications › Public Address System › Loudspeaker
Issued 7 May 2012
Resolved
Repair speakers for PA system in aft crew quarters.
Communications › Radio Communications › Satellite Communications Capability
Issued 7 May 2012
Resolved
Prove proper operation of INMARSAT C.
Fire Fighting › Automatic Sprinkler System › Pump
Issued 7 May 2012
Resolved
Prove proper operation of sprinkler pump.
Documentation › Certificates/Documents › Passenger Ship Safety Certificate
Issued 7 May 2012
Resolved
Vessel limited to domestic voyages until SOLAS documents are issued.
Engineering › Freshwater Generation System › Piping
Issued 26 October 2010
Resolved
Do not operate new water maker system until approved by the Coast Guard.
Engineering › Steering Gear System › Ram
Issued 17 September 2010
Resolved
At next US port prove proper operation and adequate repairs to Main Steering System to the satisfaction of attending USCG Marine Inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 May 2009
Resolved
Renew or pressure test CO2 discharge flexible hoses in E-gen space and flexible hose with recently hydroed CO2 bottle protecting engine room in accordance with 46 CFR 147.65.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 10 January 2008
Resolved
VESSEL MUST PROVIDE A REPAIR PROPOSAL FOR REPLACEMENT OF THE PORT PROPELLER AND COMPLETION OF THE REPLACEMENT PRIOR TO 23JAN08. VESSEL IS RESTRICTED TO THE U.S. VIRGIN ISLANDS AND BRITISH VIRGIN ISLANDS NOT MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 27 July 2006
Resolved
Replace or line all combustible waste receptacles with non-combustible material IAW 46 CFR
Electrical › Electric Supply System (service) › Cable
Issued 27 July 2006
Resolved
Remove or properly terminate dead end cable inboard of port eng under deck plate.
Fire Fighting › Fire Hoses › Condition
Issued 15 May 2006
Resolved
Renew holed firefighting hose identified during hydrostatic test.
Communications › Audible Communications › SPD (Other)
Issued 15 May 2006
Resolved
Properly repair the public address system, ensure override system for each speaker is operational, conduct weekly test of power supply for override system.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 15 May 2006
Resolved
Replace pull cable for the CO2 fixed fire fighting system in the bow thruster compartment
Lifesaving › Rescue Boat › Propulsion Engine
Issued 15 May 2006
Resolved
Conduct & log weekly tests of the rescue boats outboard engine.
Fire Fighting › Fire Pumps › Impeller
Issued 15 May 2006
Resolved
Properly repair and test the auxiliary fire pump
Fire Fighting › Means of Escape › Blocked
Issued 15 May 2006
Resolved
Ensure emergency egress route from emergency generator compartment is cleared of equipment
Fire Fighting › Means of Escape › Blocked
Issued 15 May 2006
Resolved
Ensure lockers and furniture in the crews berthing area are secured to prevent shifting and blocking of escape hatch
Communications › Alarms/Indicators › Fire Alarm
Issued 15 May 2006
Resolved
Troubleshoot and properly repair fire alarm trouble indication alarm for the steering and pump room
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 May 2006
Resolved
Properly repair and test E/R bilge high level alarm.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 15 May 2006
Resolved
Provide an approved SOLAS rescue boat prior to carrying passengers on an international voyage, excluding Great Lakes voyages
Engineering › Thrusters › Motor
Issued 1 December 2005
Resolved
Verify proper installation both on land/water as well as proper operation of newly installed Bow Thruster prior
Construction/Loadline › Structures › Door
Issued 1 December 2005
Resolved
Verify proper installation of new gaskets installed on top, port, and starboard sides of bow loading door for weathertight requirements prior to carrying passengers to the satisfaction of the attending Marine Inspector.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 4 November 2005
Resolved
Remove all combustible (non approved) furniture from crew berthing areas.
Fire Fighting › Means of Escape › Blocked
Issued 4 November 2005
Resolved
Remove lockers from blocking escape hatch in male berthing area.
Accommodation/Occupational Safety › Potable Water System › General
Issued 4 November 2005
Resolved
Properly install missing guards on water tank level gauge.
Fire Fighting › Automatic Sprinkler System › Pressure Tank
Issued 4 November 2005
Resolved
Properly install missing guards on sprinkler tank level gauge.
Stability › Water on Deck › General
Issued 4 November 2005
Resolved
Ensure drainage holes in engine room and lazarette are unplugged/installed so as to allow for proper drainage to lowest point in the space.
Stability › Watertight Integrity › General
Issued 4 November 2005
Resolved
Remove standing water from underneath the potable water tanks to allow for internal structure exam.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 12 May 2005
Resolved
Provide A class penetration for laundry dryer vents exiting laundry room.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 12 May 2005
Resolved
Provide A15 class door without vent grills or louvers in laundry room.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 12 May 2005
Resolved
Ensure each door used as a means of escape is obvious from both sides during darkened conditions
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 12 May 2005
Resolved
Provide low level alarm for steering gear oil level I.A.W 46CFR 119.600 & 58.25-25
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 12 May 2005
Resolved
Ensure carpet does not pass through doorways for all A class fire doors
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 12 May 2005
Resolved
Ensure hazard classifications for accommodation and service spaces are included on fire control plan.
Engineering › Diesel Engine (propulsion-direct drive) › Waste Heat Recovery
Issued 10 August 2004
Resolved
Stbd main engine inoperative. Water in oil.
Unknown
Issued 14 June 2001
Resolved
INSPECT PRESSURE VESSEL.
Unknown
Issued 10 May 2001
Resolved
VESSEL TO INSTALL A MARINE SAFETY INFORMATION RECEIVER WITH ENHANCED GROUP CALLING (ie; INMARSAT-C) IAW IV/4.1.7.
Unknown
Issued 10 May 2001
Resolved
VESSEL TO INSTALL A VHF RADIO WITH DSC CAPABLE OF ENCODE AND WATCH RECEIVE IAW SOLAS IV/4.1.1.
Unknown
Issued 10 May 2001
Resolved
VESSEL TO INSTALL A SECOND 406 SATELLITE EPIRB IN ORDER TO MEET DUPLICATE "SOLAS REQUIRED" RADIO COMMUNICATION EQUIPMENT IAW IV/15.7: _x001C_
Casualty record · 19
26 August 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2761820
16 November 2006Routine · role: Involved in a Marine Casualty · activity 3050686
3 August 2007Routine · role: Involved in a Marine Casualty · 1 injured · activity 3019268
10 November 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3097791
23 April 2008Routine · role: Involved in a Marine Casualty · activity 3491361
18 August 2008Routine · role: Involved in a Marine Casualty · activity 3302904
16 December 2008Routine · role: Involved in a Marine Casualty · activity 3381789
3 July 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3701812
11 August 2010Routine · role: Involved in a Marine Casualty · activity 3827320
17 September 2010Routine · role: Involved in a Marine Casualty · activity 3853647
24 July 2012Routine · role: Involved in a Marine Casualty · activity 4395802
19 May 2013Routine · role: Involved in a Marine Casualty · activity 4596658
2 December 2013Routine · role: Involved in a Marine Casualty · activity 4764131
8 December 2013Routine · role: Involved in a Marine Casualty · activity 4802731
1 July 2014Routine · role: Involved in a Marine Casualty · activity 4908119
6 July 2016Routine · role: Involved in a Marine Casualty · activity 5931554
21 July 2017Routine · role: Alleged Pollution Source · activity 6219326
30 November 2017Routine · role: Acknowledged Pollution Source · activity 6318804
10 April 2018Routine · role: Involved in a Marine Casualty · activity 6611200
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.