Records from 2013 to 2025. Most recent: inspection, 4 March 2025.
Inspection history · 20
4 March 2025
COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8084946
8 April 2024
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7892539
26 March 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7879891
11 March 2024
Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7872872
22 December 2023
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7841827
4 April 2023
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7646585
23 December 2022
Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7612553
14 October 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7574775
14 January 2022
Hull Examination · Annual Inspection · Deficiency Check · Plan Review "T" Boat
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7380691
23 September 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7316363
1 April 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7165135
10 March 2020
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6900780
28 January 2020
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6894606
23 September 2019
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6815889
2 April 2019
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6646348
20 March 2018
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6368677
19 January 2018
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6339242
20 June 2017
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6180530
19 April 2016
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5857009
19 January 2016
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5800345
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 March 2024
Resolved
On vessels described by 46 CFR 175.110(d) of this chapter, a passenger safety bill must be posted by the master in each cabin or stateroom, and in passenger accommodation spaces. Vessel did not have the passenger safety bill posted in passenger accommodation spaces. Post passenger safety bill to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2024
Resolved 8 April 2024
Resolution: Vessel created and posted Passenger Safety Bill.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 March 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First aid kit was missing ammonia inhalants and tourniquet with scissors, and 12 safety pins. Replenish first aid kit with ammonia inhalants and tourniquet kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2024
Resolved 8 April 2024
Resolution: Vessel replenished medical first-aid kit.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 March 2024
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years.
Vessel's dry dock examination date was overdue on 01FEB24. Vessel is not to carry passengers until a satisfactory dry dock examination is completed.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2024
Resolution: Drydock complete.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 April 2023
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel was missing fire buckets. Provide three 2 1/2 gallon buckets as described above.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2023
Resolved 18 April 2023
Resolution: Vessel provided fire buckets.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 4 April 2023
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. The starboard side engine ventilation closure above the salon did not latch properly. Repair and demonstrate proper operation.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2023
Resolved 18 April 2023
Resolution: Vessel repaired closure clasp.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 1 April 2021
Resolved
Provide galley ventilation hood cleaning and inspection plan in accordance with G-MOC policy letter as alternative to UL certified ventilation hood with fixed fire suppression.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2021
Resolved 2 April 2021
Resolution: Vessel provided a maintenance and cleaning plan.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 April 2021
Resolved
Repair worn clasp system for starboard engine room ventilation closure. Demonstrate capability to close ventilation and provide vapor tight seal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2021
Resolved 2 April 2021
Resolution: Vessel repaired worn clasp and demonstrated operation.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 April 2021
Resolved
Remove combustible refuse containers from accomodation spaces. Two plastic trash cans found in salon/galley.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2021
Resolved 2 April 2021
Resolution: Vessel removed plastic refuse containers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 April 2021
Resolved
Bilge pump found inoperable. Demonstrate bilge pumping from all bilge spaces.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 1 April 2021
Resolved 2 April 2021
Resolution: Vessel discovered a blockage in the bilge piping. After removing blockage vessel was able to demonstrate removal of bilge water form all compartments served by the manifold system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 March 2020
Resolved
Provide additional 40 - B:C fire extinguisher at entrance to machinery space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2020
Resolved 3 June 2020
Resolution: Vessel provided additional fire extinguisher.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 23 September 2019
Resolved
Extend captive chain for bunkroom escape hatch to allow full opening. Correct prior to carrying overnight passengers.
Action required: 705 - Other - as specified
Due 23 September 2019
Resolved 26 September 2019
Resolution: Vessel provided longer chain and demonstrated ability to fully open emergency escape hatch.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 23 September 2019
Resolved
Provide station bill prior to carrying overnight passengers.
Action required: 705 - Other - as specified
Due 23 September 2019
Resolved 26 September 2019
Resolution: Vessel provided station bill.
10 - Safety of Navigation › N/A - No Subsystem › Monitoring of voyage or passage plan
Issued 23 September 2019
Resolved
Provide voyage plan prior to carrying overnight passengers.
Action required: 705 - Other - as specified
Due 23 September 2019
Resolved 26 September 2019
Resolution: Vessel amended passenger manifest to include area for voyage plan.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 September 2019
Resolved
Provide crew manifest prior to carrying overnight passengers.
Action required: 705 - Other - as specified
Due 23 September 2019
Resolved 26 September 2019
Resolution: Vessel amended passenger manifest to include area for crew manifest.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 September 2019
Resolved
Provide UL217 listed smoke detector for bunkroom prior to carrying overnight passengers. Current detector not UL217 listed.
Action required: 705 - Other - as specified
Due 23 September 2019
Resolved 26 September 2019
Resolution: Vessel replaced non-approved smoke detector with UL217 listed combination smoke/CO detector and tested in presence of inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 September 2019
Resolved
Provide protection from electrical cables in starboard bunks prior to carrying overnight passengers.
Action required: 705 - Other - as specified
Due 23 September 2019
Resolved 26 September 2019
Resolution: Cover provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 September 2019
Resolved
Provide ammeter in battery charging circuit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2019
Resolved 10 October 2019
Resolution: New battery charger installed.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 23 September 2019
Resolved
Conduct abandon ship drills.
Action required: 10 - Deficiency Rectified
Due 23 September 2019
Resolved 23 September 2019
Resolution: Vessel conducted abandon ship drill and training during inspection.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 23 September 2019
Resolved
Crew not familiar with emergency instructions.
Action required: 10 - Deficiency Rectified
Due 23 September 2019
Resolved 23 September 2019
Resolution: Emergency instructions located and crew reviewed during inspection.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 September 2019
Resolved
Provide connection insde of protective enclosure. Bunkroom emergency lighting connected with expoed wire nut.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2019
Resolved 26 September 2019
Resolution: Vessel moved connection into emergency lighting enclosure.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 September 2019
Resolved
Demonstrate flame retardant properties of mattresses for overnight passenger and crew bunks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 October 2019
Resolved 10 October 2019
Resolution: Vessel O/O provided a signed statement attesting the age of the mattresses and provided a spray fire retardant.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 April 2019
Resolved
Provide fire hose nozzle.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2019
Resolved 4 April 2019
Resolution: Fire hose nozzle provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 April 2019
Resolved
Replace clip on water light line.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2019
Resolved 4 April 2019
Resolution: New clip installed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 20 March 2018
Resolved
Prove proper operation of emergency light in berthing prior to operating with passengers overnight.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 20 March 2018
Resolution: Verified operation of emergency light in berthing.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 20 March 2018
Resolved
Provide ready vent plugs for E/R vents prior to operating with passengers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 20 March 2018
Resolution: Verified availability of ready vent plugs for E/R vents.
Communications › Radio Communications › VHF Radiotelephone
Issued 20 June 2017
Resolved
Connect GPS to the VHF-DSC radio.
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 28 June 2017
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 20 June 2017
Resolved
Repair pull cable for stbd fire damper.
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 28 June 2017
Fire Fighting › Remote Fuel Shutoff › General
Issued 20 June 2017
Resolved
Mark aft fuel shut-off valve.
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 28 June 2017
Fire Fighting › Means of Escape › Escape Route Signs
Issued 20 June 2017
Resolved
Mark pin locations on fwd escape hatch.
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 28 June 2017
Electrical › Electrical Distribution System (service) › Switch
Issued 20 April 2016
Resolved
Replace household-grade switches in E/R with switches suitable for a wet environment.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 25 May 2016
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 20 April 2016
Resolved
Modify E/R deckboards to eliminate tripping hazard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 25 May 2016
Documentation › Markings/Placards › Warning Signs
Issued 20 April 2016
Resolved
Label all electrical panels and switches in E/R.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 25 May 2016
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 20 April 2016
Resolved
Replace broken hose clamp on port shaft water seal (shaft boot).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 April 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 20 April 2016
Resolved
Repair wet exhaust leak (port MDE)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 25 May 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 April 2016
Resolved
Remove unused electrical installations/wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 25 May 2016
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (electric)
Issued 19 April 2016
Resolved
Prove proper operation of genset.
Action required: 705 - Other - as specified
Due 20 April 2016
Resolved 20 May 2016