Records from 1982 to 2019. Most recent: inspection, 16 May 2019.
Documentation record
Registered dimensions (L × B × D)167.3 ft × 38.0 ft × 13.5 ft
Registered tonnagegross 271 / net 184
ITC dimensions (L × B × D)167.3 ft × 38.0 ft × 13.5 ft
ITC tonnagegross 647 / net 194
BuilderHALTER MARINE SERVICES · LOCKPORT, LA, UNITED STATES · built 1973
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portREEDVILLE, VA
Trade endorsementsFishery
DocumentationValid · issued 10 February 2026 · expires 31 January 2027
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it184 - Regulatory (Subpart C or D), Net Ton
194 - Convention (Subpart B), Net Ton
271 - Regulatory (Subpart C or D), Gross Ton
647 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 51
16 May 2019
Type not recorded
No type recorded · USCGC RAZORBILL (WPB 87332) · USCG Heartland District (CGD-H) · Activity 6686944
3 August 2017
Type not recorded
No type recorded · USCGC CROCODILE (WPB 87369) · USCG East District (CGD-E) · Activity 6230569
14 January 2010
Cargo Tank Internal · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3663643
12 March 2009
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3432467
5 June 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3228124
4 April 2007
Examination of Repairs · Hull Examination · Internal Structural Exam · Cargo Tank Internal · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2919102
7 June 2006
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2652803
24 March 2005
Examination of Repairs · Hull Examination · Cargo Tank Internal · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2318888
17 September 2004
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2197928
16 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1965041
28 November 2003
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1959017
3 September 2003
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1895651
26 June 2003
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1827289
12 February 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1758898
2 May 2002
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1602980
27 June 2001
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1067557
15 October 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 17006
29 June 2000
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441650
16 February 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 816281
10 April 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1115625
4 June 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 793215
4 June 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 809442
2 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783365
10 December 1997
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 762696
9 November 1997
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 192021
31 October 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 762489
30 October 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 192018
10 April 1997
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442532
3 September 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354001
11 September 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 5782
3 July 1995
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1353776
12 April 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 670217
13 March 1995
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1180323
13 December 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212908
16 March 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366999
22 March 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 670215
21 March 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 102011
21 January 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447208
10 July 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1256966
21 February 1992
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1264467
7 May 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915135
6 March 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1212155
5 March 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1212429
31 January 1990
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234578
13 January 1989
COI Inspection · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205099
19 January 1988
Re-Inspection · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1017958
13 January 1987
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013370
1 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1307171
24 May 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 981654
23 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977350
12 March 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273929
Electrical › Electric Generation Source (service) › Generator
Issued 14 January 2010
Resolved
Clean generator armature.
Action required: 705 - Other - as specified
Due 3 March 2010
Resolved 19 March 2010
Resolution: Cleared by attending inspector.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 14 January 2010
Resolved
Provide E-Lighting for forward hallway door.
Action required: 705 - Other - as specified
Due 3 March 2010
Resolved 19 March 2010
Resolution: Cleared by attending inspector.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 14 January 2010
Resolved
Provide bilge strainers for bilge piping suction.
Action required: 705 - Other - as specified
Due 3 March 2010
Resolved 19 March 2010
Resolution: Cleared by attending inspector.
Operations/Management › FireFighting › Patrol System (Special Category Spaces)
Issued 14 January 2010
Resolved
Replace paint locker gasket.
Action required: 705 - Other - as specified
Due 3 March 2010
Resolved 19 March 2010
Resolution: Cleared by attending inspector.
Electrical › Electric Supply System (service)
Issued 3 September 2003
Resolved
Remove wing nuts iwo battery cable in engine room. LEGACY COMPONENT DESC: Cable
Due 2 October 2003
Resolved 3 September 2003
Navigation › Piloting/Steering › Marine Charts
Issued 3 September 2003
Resolved
Missing Navigational Chart 11347
Due 2 October 2003
Resolved 3 September 2003
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 3 September 2003
Resolved
Clean aft draft marks to make them more visible.
Due 2 October 2003
Resolved 3 September 2003
Communications › Internal Communications System › Sound-powered Telephone
Issued 2 May 2002
Resolved
PROPERLY REPAIR ENGINE ROOM SOUND POWERED PHONE VISUAL CALL INDICATOR.
Condition: Improper Installation
Due 2 May 2002
Resolved 2 May 2002
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 2 May 2002
Resolved
PROPERLY REPAIR GROUND ON "B" LEG OF POWER DISTRIBUTION SYSTEM.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2002
Resolved 2 May 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 2 May 2002
Resolved
REPAIR ALL PILOTHOUSE GAUGES LEGACY COMPONENT DESC: GAUGES
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2002
Resolved 2 May 2002
Engineering › Fuel Oil Service System › Hose
Issued 2 May 2002
Resolved
PROPERLY REROUTE ALL GENERATOR FUEL OIL LINES AWAY FROM ROTATING MACHINERY.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2002
Resolved 2 May 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 2 May 2002
Resolved
INSTALL REMOTE SHUTDOWN FOR ENGINE DRIVEN LIQUID MUD PUMP.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2002
Resolved 3 May 2002
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 May 2002
Resolved
INSTALL 02 ADDITIONAL EMERGENCY EGRESS LIGHTS. ONE AT EACH ENGINE ROOM EMERGENCY EXIT.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2002
Resolved 2 May 2002
Documentation
Issued 29 June 2000
Resolved
Provide new tonnage information to National Vessel Documentation Center fornew issue of VSL DOC w/ new tonnage.
Condition: Unknown
Due 29 June 2000
Resolved 29 June 2000
Documentation
Issued 3 July 1995
Resolved
VESSEL LOAD LINE CERTIFICATE TO BE REISSUED DUE TO STABILITY ISSUES.
Condition: Unknown
Due 7 August 1995
Resolved 7 August 1995
Documentation
Issued 3 July 1995
Resolved
VESSEL RESTRICTED FROM OPERATION UNTILL NEW STABILITY LETTER IS ISSUED.
Condition: Unknown
Due 7 August 1995
Resolved 7 August 1995
Electrical
Issued 5 March 1991
Resolved
INSTALL EMERGENCY LIGHT COMPANIONWAY TO RUDDER ROOM.
Condition: Unknown
Due 5 March 1991
Resolved 5 March 1991
Fire Fighting
Issued 5 March 1991
Resolved
POST ONBOARD GENERAL ARRANGEMENT PLAN IAW 46 CFR 97.36-1.
Condition: Unknown
Due 5 March 1991
Resolved 5 March 1991
Engineering
Issued 5 March 1991
Resolved
MAKE PERMANENT REPAIRS F/O DAY TANK. TANK MUST BE GAS FREED PRIOR TO _x001C_ CONDUCTING REPAIRS.
Condition: Unknown
Due 5 March 1991
Resolved 5 March 1991
Unknown
Issued 23 March 1984
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 23 March 1984
Resolved 23 March 1984