MAURY USCG vessel records
← All vessels

GLADYS S

GLADYS S is a 1973 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2016, most recently in September 2025, along with 58 deficiencies, 5 operational controls and 1 casualty investigation in 2009.

Records from 2009 to 2025. Most recent: inspection, 5 September 2025.

Built
1973
Last inspected
5 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 September 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB9526
Flag
UNITED STATES
Maury page id
psix-47525

Documentation record

Registered dimensions (L × B × D)90.0 ft × 21.0 ft × 8.8 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAMCRAFT INC · CROWN POINT, LA, UNITED STATES · built 1973
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Regulatory (Subpart C or D), Net Ton
96 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

26 inspections, each with its date, unit and type; 58 deficiencies with the resolution recorded against each; 5 operational controls with the dates imposed and removed; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 26

5 September 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8182696
21 April 2025 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8100327
11 September 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7975806
11 September 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7762724
23 March 2023 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7639599
25 January 2023 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7627181
3 October 2022 Appeal
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7602060
16 September 2022 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7559224
24 June 2022 Deficiency Check · COI Inspection · Re-Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7485873
16 June 2022 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7476646
10 February 2022 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7411647
25 August 2021 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7296642
20 August 2021 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7292235
11 August 2021 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7284024
7 July 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7248103
9 July 2020 Administrative Inspection · Deficiency Check · In-Service Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6991434
14 August 2019 Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6713355
9 July 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6632970
3 July 2019 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6831007
9 July 2018 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6473672
28 November 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6314084
26 September 2017 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6282876
27 July 2017 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6214424
11 April 2017 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6073772
12 August 2016 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5970895
27 May 2016 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5886942

Deficiency record · 58

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 September 2025 Resolved
The installation and location of portable fire extinguishers must be to the satisfaction of the officer in charge, marine inspection. The mount for the portable fire extinguisher in the Galley space was the wrong size and incorrectly mounted. Correctly/securely mount fire extinguisher and make available for inspection to the attending marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2025
Resolved 15 September 2025
Resolution: O/O ordered new bracket and had portable fire ext. properlly mounted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 September 2024 Resolved
Each fire hose must be lined commercial fire hose that conforms to UL 19, or hose that is listed and labeled by an independent laboratory recognized by the Commandant as being equivalent in performance. MI identified that 02 non operational fire
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 2 October 2024
Resolution: Installed approved hoses.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 September 2024 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. MI identified inoperable emergency lights.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 2 October 2024
Resolution: Lights are fixed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 September 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to guards and rails in hazardous places for passengers and crew. MI identified that the steering gear pumps had no guards around the rotating shaft.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 2 October 2024
Resolution: Guards installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 September 2024 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Sight glass for hydraulic oil tank is improperly installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 2 October 2024
Resolution: sight glass removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2024 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries. MI id'd missing lagging on both generator exhaust piping.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 2 October 2024
Resolution: Lagging replaced.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 11 September 2024 Resolved
Owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure including the following: Accessible parts of the exterior & interior of the hull. MI identified a hole in the stbd side overhead of lazarette.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 2 October 2024
Resolution: Clad welded hole in deck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 September 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI identified that the fuel oil priming pump was incorrectly wired.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 2 October 2024
Resolution: Pump properly installed.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 11 September 2024 Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. MI identified that the internal PA system was inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 2 October 2024
Resolution: PA system is working all around vessel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 September 2024 Resolved
Owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure including the following: Accessible parts of the exterior & interior of the hull. MI id'd cracked welds & bent frames on stbd side overhead of lazarette.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 2 October 2024
Resolution: O/O replaced broken beams.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 September 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI identified several electrical boxes were broken or missing covers.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 2 October 2024
Resolution: All wiring issues corrected.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 11 September 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: Prevent electrical ignition of flammable vapors. MI identified exposed wiring & missing cover for directional control valve for steering system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 2 October 2024
Resolution: Wires covered by a plate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 September 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating without exceeding its designed limitations. MI identified that the center main diesel engine had an alarm for over voltage.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 2 October 2024
Resolution: CAT Tech came out and cleared the alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 February 2022 Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel except that a float-free link is not required if the vessel operates only on waters not as deep as the length of the painter; Vessel did not have IBA stowed with in a way to float free.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2022
Resolved 10 February 2022
Resolution: Vessel properly installed hydrostatic release. Cleared 01 deficiency
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 25 August 2021 Resolved
Head intake valve is seized and could not be removed for inspection. Replace head intake valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 August 2021
Resolution: Head intake valve replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 25 August 2021 Resolved
Portside fresh water intake valve is not attached to a tank below deck. Cap off or remove pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 August 2021
Resolution: Pipe is capped off and watertight.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 25 August 2021 Resolved
STBD side fresh water pipe vent is missing the goose neck at the top of pipe. Replace goose neck on top of pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 August 2021
Resolution: Goose neck for fresh water vent replaced.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 7 July 2021 Resolved
Where cable protection is carried through watertight bulkheads, the installation shall ensure the watertight integrity. Vessel has multiple cable runs on port side forward bulkhead of engine room that is not watertight. Vessel to prove watertight integrity of bulkhead. 46 CFR 183.10-20
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2021
Resolved 22 July 2021
Resolution: MI attended vessel and saw satisfactory rectification of penetrations.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 July 2021 Resolved
Marine employers shall establish programs for chemical testing on a random basis for crew members. Vessel's consortium information is expired. Vessel to provide valid consortium information. 46 CFR 16.230
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 7 July 2021
Resolution: Vessel provided documentation prior to the end of the inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 July 2021 Resolved
At each inspection bilges and other spaces may be examined to see that there is no accumulation of oil. MI noted excessive hydraulic oil in bilges below accommodation spaces. Crew cleaned before the end of the inspection. 46 CFR 176.830
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 7 July 2021
Resolution: Crew cleaned the space prior to the end of the inpsection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2021 Resolved
All cable and wire must be installed with metal supports not more than 24 inches apart. Plastic tie wraps are limited to bundling. MI noted plastic tie wraps used as supports throughout the engine room. Vessel to provide proper supports.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2021
Resolved 22 July 2021
Resolution: Vessel installed metal supports throughout spaces.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 July 2021 Resolved
An inspection of bridge-to-bridge radio stations must be conducted by an FCC licensed technician. Vessel's Radiotelephony Certificate is expired. Vessel to provide valid certificate. 47 CFR 80.59
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2021
Resolved 11 August 2021
Resolution: Vessel submitted satisfactory evidence of obtaining an approved FCC radiotelephony certificate.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 July 2020 Resolved
A fire hose with a nozzle must be attached to each fire hydrant at all times. Only one out of two fire hydrants had an attached hose with nozzle. Provide and install additional hose with nozzle on second hydrant.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2020
Resolved 25 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 July 2020 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Starboard generator engine oil temperature sensor leaking.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 August 2020
Resolved 25 August 2020
Resolution: Removed and replaced sensor.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2020 Resolved
The operator must secure each type III device in a manner which prevents discharge of sewage. Discharge valve missing locking mechanism. Padlock valve in closed position.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 9 July 2020
Resolved 25 August 2020
Resolution: Installed lock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2019 Resolved
Shutoff valves installed so as to close against the fuel flow shall be fitted in the fuel supply lines. The shutoff valve at the tank must be operable from outside the compartment in which the valve is located. Emergency fuel shutoff valve on STBD main engine fuel tank sheared off and is inoperable. Prove proper installation / operation of new valve. 46CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 July 2019
Resolved 10 July 2019
Resolution: MI WITNESSED PROPER OPERATION OF NEWLY INSTALLED EMERGENCY FUEL SHUTOFF VALVE.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 9 July 2019 Resolved
THE CONSTRUCTION AND ARRANGEMENT OF A VESSEL MUST ALLOW THE SAFE OPERATION OF THE VESSEL IN ACCORDANCE WITH THE TERMS OF ITS COI GIVING CONSIDERATION TO PROVISIONS FOR A SEAWORTHY HULL. FRACTURE DISCOVERED IN FOREPEAK TANK ON CENTER GIRDER / KEEL FRAME. EFFECT PROPER REPAIRS AND CONDUCT WEEKLY CHECKS ON DAMAGE, TO BE LOGGED IN SHIPS OFFICIAL LOGBOOK, UNTIL SUCH REPAIRS ARE COMPLETE. 46CFR 177.110
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 14 August 2019
Resolution: Welded fracture.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 9 July 2019 Resolved
PIPING, THE TEMPERATURE OF WHICH EXCEEDS 65.5C (150F) MUST BE SUITABLY INSULATED WHERE NECCESARY TO PREVENT INJURIES. HYDRAULIC LINES RUNNING THE LENGTH OF THE VESSEL ARE EXCESSIVELY HOT AND REQUIRE LAGGING / COVERS. PROVE PROPER INSTALLATION.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 10 September 2019
Resolution: deficency rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 July 2019 Resolved
A VESSEL MUST BE PROVIDED WITH SATISFACTORY ARRANGEMENT FOR DRAINING ANY WATER TIGHT COMPARTMENT. BILGE LINE CONNECTION IN GALLEY SPACE HAD WASTED GASKE. EFFECT PROPER REPAIRS AND PROVE OPERATION.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 5 September 2019
Resolution: Replaced with new gasket.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 July 2019 Resolved
ELECTRICAL EQUIPMENT ON A VESSEL MUST BE INSTALLED AND MAINTAINED TO: PROTECT PASSENGERS, CREW, OTHER PERSONS, AND THE VESSEL, FROM ELECTRICAL HAZARD, INCLUDING FIRE, CAUSED BY OR ORIGINATING IN ELECTRICAL EQUIPMENT. EXPOSED LIVE WIRING FOUND ON AIR COMPRESSORS. COVER OR PROVE PROPER INSTALLATION.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 5 September 2019
Resolution: Installed cover
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 July 2019 Resolved
ELECTRICAL EQIPMENT ON A VESSEL MUST BE INSTALLED AND MAINTAINED TO: MINIMIZE ACCIDENTAL PERSONNEL CONTACT WITH ENERGIZED PARTS. DISCOVERED MISSING BLANK IN PAX SPACE ELECTRICAL PANEL. PROVE PROPER INSTALLATION.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 5 September 2019
Resolution: Installed blank in panel.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 9 July 2019 Resolved
AN EXPOSED HAZARD, SUCH AS GEARS OR ROTATING MACHINERY, MUST BE PROPERLY PROTECTED BY A COVER, GUARD, OR RAIL. MACHINERY GUARD ON PORT GENERATOR ROTATING MACHINERY MISSING. PROVE PROPER INSTALLATION.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 14 August 2019
Resolution: Installed guard on port generator.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 July 2019 Resolved
THE INSTALLATION AND LOCATION OF PORTABLE FIRE EXTINGUISHERS MUST BE TO THE SATISFACTION OF THE [name withheld] SPACE MISSING BRACKET (SECURED W/ BUNGEY CORD). REPLACE BRACKET AND PROVE PROPER INSTALLATION.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 14 August 2019
Resolution: Installed new bracket for portable fire extinguisher.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2019 Resolved
MATERIALS USED IN PIPING SYSTEM S MUST MEET THE REQUIREMENTS OF THIS SUBPART AND OTHERWISE BE ACCEPTABLE TO THE [name withheld] WATER PUMP FOR MSD WAS ACTIVELY LEAKING. EFFECT REPAIRS AND PROVE PROPER OPERATION.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 14 August 2019
Resolution: Installed new pipping and leaking stopped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2019 Resolved
THE GENERAL CONSTRUCTION OF THE VESSEL MUST BE SUCH AS TO MINIMIZE FIRE HAZARDS. HYDRAULIC LEAK FROM LINES UNDER STEERING CONSOLE IN WAY OF ELECTRICAL WIRING DISCOVERED. EFFECT PROPER REPAIRS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 10 September 2019
Resolution: deficency rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 9 July 2019 Resolved
ALL MACHINERY AND EQUIPMENT MUST BE INSTALLED AND MAINTAINED IN SUCH A MANNER AS TO AFFORD ADEQUATE PROTECTION FROM CAUSING FIRE, EXPLOSION, OR PERSONNEL INJURY. EXPANSION TANK ON STBD GENERATOR UNCAPPED. PROVE PROPER INSTALLATION.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2019
Resolved 5 September 2019
Resolution: Expansion tank cap installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 July 2019 Resolved
The vessels COI requires 50 adult life jackets to be onboard. During inspection eight life jackets (PFD vest style) were found to be in unsatisfactory condition. The eight PFD's were removed from service. The vessels passenger count is reduced to 42 persons until the eight PFD's are replaced and verified by the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2019
Resolved 3 July 2019
Resolution: Operator placed eight PFD's onboard the vessel. PFD's found to be in satisfactory condition and properly labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 July 2019 Resolved
A fire hazard was found to exist within the vessels pilot house. Three battery boxes under the control panel do not have lids/covers to keep the terminals free from water/debris exposure. Additionally, use rags are stored at the base of the battery boxes and should be removed to reduce fire hazard. Lids/covers should be placed on the three battery boxes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2019
Resolved 3 July 2019
Resolution: Operator placed lids/covers onto the battery boxes and removed rags.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 July 2018 Resolved
PROVE PROPER OPERATION OF BILGE PUMP PRIOR TO MOVEMENT.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 July 2018
Resolved 2 August 2018
Resolution: Witnessed satisfactory test of bilge pump.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 July 2018 Resolved
REPAIR FUEL LEAKS AS INDICATED BY MARINE INSPECTOR PRIOR TO MOVEMENT.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 July 2018
Resolved 2 August 2018
Resolution: Sighted fuel lines have been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2018 Resolved
REPAIR EXHAUST LEAK NEAR PORT ENGINE TURBO AS INDICATED BY MARINE INSPECTOR PRIOR TO OPERATING MACHINERY.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 July 2018
Resolved 2 August 2018
Resolution: Sighted repaired exhaust pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2018 Resolved
CLEAN ALTERNATOR AND GENERATOR WINDINGS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 July 2018
Resolved 2 August 2018
Resolution: Found generator and alternators satisfactory.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 July 2018 Resolved
CLEAN OILY MIX IN BILGE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2018
Resolved 2 August 2018
Resolution: Bilge found clean.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2018 Resolved
MAKE EXHAUST MANIFOLD AVAILABLE FOR INSPECTION FOR ALL ENGINES.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 July 2018
Resolved 2 August 2018
Resolution: Exhaust pipes where available for inspection.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 July 2018 Resolved
REPAIR/PROVE PROPER OPERATION OF FIREMAIN.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2018
Resolved 2 August 2018
Resolution: Witnessed satisfactory test of fire pump.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 17 August 2017 Resolved
Renew Type III sewage tank.
Due 30 September 2017
Resolved 19 October 2017
Resolution: A new sewage type III holding tanks was installed.
Construction/Loadline › Hull › Hull Plating
Issued 3 August 2017 Resolved
Forepeak Conduct NDT (dye pen) on marked indented area to determine if a crack or fracture exist.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 11 August 2017
Construction/Loadline › Hull › Side Shell
Issued 3 August 2017 Resolved
Grind out and reweld fractured weld as morked on the starboard side shell.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 11 August 2017
Construction/Loadline › Hull › Side Shell
Issued 3 August 2017 Resolved
Cut back to good aluminum and insert minimium 18 x 18 insert with radius corners on the port bow.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 14 August 2017
Construction/Loadline › Hull › Bottom Plating
Issued 3 August 2017 Resolved
Make port and starboard skegs watertight and conduct pressure test.
Due 18 August 2017
Resolved 17 August 2017
Construction/Loadline › Hull › Weld
Issued 3 August 2017 Resolved
Drill out and weld deep pitted area on the starboard strut reinforcement ring.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 11 August 2017
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 3 August 2017 Resolved
Make sewage tank available for inspection.
Action required: 705 - Other - as specified
Due 18 August 2017
Resolved 17 August 2017
Stability › Watertight Integrity › General
Issued 27 July 2017 Resolved
Make superstructure (pilot house) windows watertight.
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 6 September 2017
Engineering › Bilge Water Management System › Not Operational
Issued 11 April 2017 Resolved
Prove proper operation of bilge suction from galley compartment, prior to carrying passengers. 46CFR182.25-10
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2017
Resolution: Operator replaced faulty valve and corroded piping and proved proper operation of bilge suction from the galley compartment.
Communications › Alarms/Indicators › High Water Alarm
Issued 11 April 2017 Resolved
Provide a visual and audible alarm at the operating station for the bilge high level alarm in the salon space prior to carrying passengers. 46CFR182.530(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 April 2017
Resolution: Operator installed new alarm in operating station.
Engineering › Bilge Water Management System › Valve
Issued 11 April 2017 Resolved
Install a positive shutoff valve at the hull penetration for electric bilge pumps in the engine room and lazarette. 46CFR182.520(e)(7)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: Operator installed ball valves at the hull penetrations for the electric bilge pumps in both the engine room and lazarette.
Documentation › Markings/Placards › Warning Signs
Issued 11 April 2017 Resolved
Properly label forward escape hatch on both sides. 46 CFR 185.606
Action required: 705 - Other - as specified
Resolved 11 April 2017
Resolution: Operator labeled emergency escape hatch on outside portion of the hatch.
Construction/Loadline › Hull › Hull Plating
Issued 12 August 2016 Resolved
Remove bodno and make vessel ready for ISE
Due 9 September 2016
Resolved 14 September 2016
Resolution: ISE Completed

Casualty record · 1

26 April 2009Routine · role: Involved in a Marine Casualty · activity 3468949
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.