MAURY USCG vessel records Sign in
← All vessels

PRIMETIME

PRIMETIME is a 1973 commercial fishing vessel. The Coast Guard has recorded 60 inspections since 1985, most recently in January 2025, along with 196 deficiencies and 1 casualty investigation in 2019.

Records from 1985 to 2025. Most recent: inspection, 5 January 2025.

Built
1973
Last inspected
5 January 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

KUS54830
Flag
UNITED STATES
303313000
Maury page id
psix-47529

Inspections, by type

…with no type recorded12
Years with a record 26 calendar years (1985–2025)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)36.1 ft × 12.1 ft × 5.1 ft
Registered tonnagegross 18 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMODUTECH PLASTICS INC · TACOMA, WA, UNITED STATES · built 1973
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHALF MOON BAY, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 11 August 2026 · expires 31 August 2027
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Regulatory (Subpart C or D), Net Ton
18 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN4838MMSI 303313000 · active · compulsorily equipped · granted 9 November 2022, expires 9 November 2032
WDG6093MMSI 303313000 · cancelled · compulsorily equipped · granted 14 November 2012, cancelled 2 November 2022
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 60

5 January 2025 Type not recorded
No type recorded · Station Golden Gate · USCG Southwest District (CGD-SW) · Activity 8059692
20 December 2019 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6891145
9 April 2009 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3449289
4 April 2008 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3177717
14 February 2008 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3135189
8 November 2007 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3095838
2 November 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3092167
13 July 2007 Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2991650
9 July 2007 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2989858
25 June 2007 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2973744
21 June 2007 Administrative Inspection
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2970270
2 October 2006 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2789427
28 September 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2789217
5 September 2006 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2757875
21 August 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2755432
16 August 2006 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2750271
29 November 2005 Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 2543032
18 November 2005 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2788067
26 April 2005 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2315736
16 March 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2312654
21 June 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2106224
19 May 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2072519
3 June 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1807990
30 April 2003 Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1779051
13 August 2002 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1661085
20 August 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1469704
2 April 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1060004
28 March 2001 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1406931
30 May 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1404982
21 May 1999 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1429160
29 March 1999 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1411849
3 July 1997 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1113091
11 March 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1416459
6 June 1996 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1428645
3 August 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 56500
3 April 1995 Deficiency Check · Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1355170
13 June 1994 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1431368
6 July 1993 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1157865
24 June 1993 Inclining Experiment
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1156470
1 June 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 839460
22 April 1993 Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1403634
22 February 1993 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1407115
10 November 1992 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 956018
24 June 1992 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1257392
13 May 1992 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 950269
29 April 1991 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 918618
9 April 1991 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1222909
30 October 1990 Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1237840
23 July 1990 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 922028
22 June 1990 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1238390
17 May 1989 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1030786
20 April 1989 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1035180
1 December 1988 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 894917
6 May 1988 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1344790
31 March 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 992378
19 May 1987 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1004274
19 May 1986 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1306149
27 March 1986 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1305504
14 November 1985 Credit Drydock
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 990701
14 May 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1288427

Deficiency record · 196

Documentation › Logs/Records › Drug Test Records
Issued 9 April 2009 Resolved
Company could not provide a Substance Abuse Professional (SAP) name and contact information as required by 49 CFR 40.287
Due 8 May 2009
Resolved 9 April 2009
Resolution: Company faxed over SAP contact information provided by company''s consortium
Documentation › Logs/Records › Drug Test Records
Issued 9 April 2009 Resolved
Owner did not have a copy of 2008 MIS report at the time of the audit as required by 46 CFR 16.500.
Due 9 April 2009
Resolved 9 April 2009
Resolution: Company faxed over 2008 MIS report.
Documentation › Certificates/Documents › FCC SSL
Issued 4 April 2008 Resolved
Provide current FCC Station License, FCC Safety License, Marine Radio Operator Permit for Master.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2020
Documentation › Certificates/Documents › Stability Letter
Issued 4 April 2008 Resolved
Properly post stability letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2008 Resolved
Properly support wiring in engine room with metallic supports IAW 46CFR183.340(b)(4).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Navigation › Piloting/Steering › Marine Charts
Issued 4 April 2008 Resolved
Provide marine chart for vessel's operating area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 4 April 2008 Resolved
Properly secure bilge pump in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Engineering › Steering Gear System › Hydraulic Hose
Issued 4 April 2008 Resolved
Repair leaks on hydraulic lines for steering system under pilot house console.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 4 April 2008 Resolved
Correct vessel NOAA EPIRB registration form with owners e-mail address.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 4 April 2008 Resolved
Provide log entries for monthly EPIRB tests, NOAA registration information, EPIRB battery expiration/installation date, and hydrostatic release expiration date.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2008 Resolved
Provide supports for bilge pump and high water alarm wiring in lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 4 April 2008 Resolved
Replace all of the batteries for the life jacket water lights. Batteries are expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 April 2008 Resolved
Remove or cap the pipe leading through the forward engine room bulkhead to the amidships bilge area to ensure bulkhead is water tight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 April 2008 Resolved
Provide 7 adult type I PFD's for a total of 22 adult PFD's onboard vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Electrical › Electric Supply System (service) › Cable
Issued 4 April 2008 Resolved
Replace the frayed battery cable in the forward most cable box in the amidships bilge area with marine grade battery cables.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Engineering › Steering Gear System › Hydraulic Hose
Issued 4 April 2008 Resolved
Repair hydraulic leak in aft starboard corner of the amidships compartment. Hydraulic lines for crab pot winch is leaking all over the electrical wiring/cables in compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 4 April 2008 Resolved
Replace expired hydrostatic release for EPIRB. Current hydrostatic release will expire in April 2008.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2020
Stability › Weathertight Integrity › General
Issued 14 February 2008 Resolved
Provide securing devices for engine room hatch cover IAW 46 CFR 174.220.
Due 14 March 2008
Resolved 4 April 2008
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 14 February 2008 Resolved
Properly lock/secure overboard discharge for sewage tank. Valve was found in the open position at the mooring in Emeryville.
Due 14 February 2008
Resolved 14 February 2008
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 14 February 2008 Resolved
Provide proper/current lifesaving maintenance logs.
Due 14 March 2008
Resolved 4 April 2008
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 14 February 2008 Resolved
Submit plan proposal for work lights mounted on top of pilot house. Lights shall not be used until plans are approved, lights are properly installed, and the installation is approved by attending marine inspector.
Due 14 March 2008
Resolved 4 April 2008
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 14 February 2008 Resolved
Conduct DAPI audit with D11 DAPI, [name withheld] must be reviewed and compliant to the satisfaction of the D11 DAPI Auditor. Deficiency must be cleared prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Operations/Management › Drills/Instruction › Fire
Issued 14 February 2008 Resolved
Conduct a satisfactory fire drill prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
Company program missing as required by 46 CFR part 16.401.
Due 6 December 2007
Resolved 5 March 2008
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
No acceptable proof of five-panel testing as required by 49 CFR 40.85.
Due 6 December 2007
Resolved 5 March 2008
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
Positive drug test records not kept for 5 years as required by 46 CFR 16.260.
Due 6 December 2007
Resolved 5 March 2008
Resolution: Training conducted.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
Negative test results not maintained for 1 year as required by 46 CFR 16.260.
Due 6 December 2007
Resolved 8 November 2007
Resolution: Training conducted. Owner will retain future negatives for 1 year.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
Company currently does not receive result/exemptions for pre-employment testing prior to an individual working in a safety sensitive position, as required by 46 CFR 16.210.
Due 6 December 2007
Resolved 4 April 2008
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
Documentation of pre-employment testing not kept for entire employment period as required by 46 CFR 16.260.
Due 6 December 2007
Resolved 4 April 2008
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
Drug and alcohol history checks not being completed as required by 49 CFR 40.25.
Due 6 December 2007
Resolved 5 March 2008
Resolution: Documentation showing history checks for three crewmembers provided.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
Random drug testing was found to not be conducted in accordance with 46 CFR 16.230. Company owner was unaware of any employee being randomly tested.
Due 6 December 2007
Resolved 4 April 2008
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
Statistically based method not currently being used to determine when random testing takes place as required by 46 CFR part 16.230. Owner had no knowledge, or proof, that any of his employees had ever been randomly tested.
Due 6 December 2007
Resolved 5 March 2008
Resolution: Provided Maritime Consortium documentation that all enrolled personnel will be tested at 50% annually.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
Testing is not spread equally throughout the year as required by 46 CFR 16.230. No record of random drug testing having ever been conducted.
Due 6 December 2007
Resolved 4 April 2008
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
All required personnel are not in the random drug testing pool as required by 46 CFR 16.230. Based on fragmented paperwork it apears that two employees no longer employed are still on the list and the two employees who do actually work do not have pre-employment tests on record.
Due 6 December 2007
Resolved 5 March 2008
Resolution: All three current employees are enrolled and in good standing with the Maritime Consortium.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
Arrangements not made for post-casualty testing as required by 46 CFR part 16.240. Owner did not remember time limitations for testing and alcohol testing devices were not onboard two of the three vessels.
Due 6 December 2007
Resolved 4 April 2008
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
Alcohol testing devices not onboard two of the three vessels as required by 46 CFR part 4.
Due 6 December 2007
Resolved 4 April 2008
Resolution: Devices confirmed to be on the Prime Time- the only vessel being evaluated for a COI.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
Employee assistance program statement not posted as required by 46 CFR 16.401.
Due 6 December 2007
Resolved 4 April 2008
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
Employee Assistance Program (EAP) hotline phone number not posted as required by 46 CFR part 16.401.
Due 6 December 2007
Resolved 4 April 2008
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 6 December 2007
Resolved 4 April 2008
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
Supervisors had not received 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR part 16.401. Owner provided signed list provided by [name withheld] but could not articulate what the training source was, where it had came from, or what the training had entailed.
Due 6 December 2007
Resolved 4 April 2008
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information to make available to employees, per 49 CFR 40.287.
Due 6 December 2007
Resolved 4 April 2008
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
No copy of contract or proof of enrollment in Consortium as required by 46 CFR 16. Owner unsure as to whether his company is a part of the National Testing Association, Inc. or Maritime Consortium.
Due 6 December 2007
Resolved 5 March 2008
Resolution: Proof of enrollment in the Maritime Consortium provided.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
Covered employees list not up to date in accordance with 46 CFR 16.230. List presented was not recent, included two persons owner said were no longer employed.
Due 6 December 2007
Resolved 5 March 2008
Resolution: All three current employees were enrolled and in good standing with the Maritime Consortium.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007 Resolved
Security of records not maintained in accordance with 49 CFR 40.333. Owner indicated he only has his own drug test results and believes employees have received and maintained copies of their own pre-employement test results.
Due 6 December 2007
Resolved 5 March 2008
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 November 2007 Resolved
Replace two child size Type I PFD's saturated with hydraulic oil.
Due 16 November 2007
Resolved 15 November 2007
Resolution: Corrected on the spot.
Electrical › Electric Supply System (service) › Cable
Issued 13 July 2007 Resolved
Repair exposed electrical wire to bilge bump in way of lazarette.
Due 13 August 2007
Resolved 17 August 2007
Stability › Watertight Integrity › General
Issued 13 July 2007 Resolved
Seal cable penetration in bulkhead between lazarette and engine room making it watertight.
Due 13 August 2007
Resolved 14 February 2008
Engineering › Fuel Oil Service System › Filter
Issued 13 July 2007 Resolved
Remount hanging fuel filter housing on main engine.
Due 13 August 2007
Resolved 17 August 2007
Operations/Management › Passenger Operations › Safety Orientation
Issued 9 July 2007 Resolved
Vessel restricted from carrying passengers for hire until a credit hull exam is completed by an attending Marine Inspector.
Due 9 September 2007
Resolved 13 July 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 25 June 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2007
Resolved 28 June 2007
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007 Resolved
Company policy missing as required by 46 CFR part 16.401. (Sample policy provided.)
Due 21 July 2007
Resolved 17 August 2007
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007 Resolved
No acceptable proof of five-panel testing as required by 49 CFR 40.85.
Due 21 July 2007
Resolved 17 August 2007
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007 Resolved
Company currently does not conduct any pre-employment tests on employees, as required by 46 CFR 16.210.
Due 21 July 2007
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007 Resolved
Drug and alcohol history checks not being completed as required by 49 CFR 40.25.
Due 21 July 2007
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007 Resolved
Statistically based method not currently being used to determine when random testing takes place. (Employees currently get tested every May.)
Due 21 July 2007
Resolved 17 August 2007
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007 Resolved
Testing is not spread equally throughout the year as required by 46 CFR 16.230. (Employees currently tested every May.)
Due 21 July 2007
Resolved 17 August 2007
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007 Resolved
All required personnel are not in the random drug testing pool as required by 46 CFR 16.230. (Company currently only updates list annually when prompted by consortium.)
Due 21 July 2007
Resolved 17 August 2007
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007 Resolved
Arrangements not made for post-casualty testing as required by 46 CFR part 16.240. (Employer needs to know where collection facilities are and what hours/days they are open.)
Due 21 July 2007
Resolved 17 August 2007
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007 Resolved
Arrangements not made for reasonable testing as required by 46 CFR part 16.250. (Employer needs to know where collection facilities are and what hours/days they are open.)
Due 21 July 2007
Resolved 17 August 2007
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007 Resolved
Employee Assistance Program (EAP) hotline phone number not posted as required by 46 CFR part 16.401.
Due 21 July 2007
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007 Resolved
Supervisors had not received 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR part 16.401.
Due 21 July 2007
Resolved 17 August 2007
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007 Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information to make available to employees, per 49 CFR 40.287.
Due 21 July 2007
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007 Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Due 21 July 2007
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007 Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Due 21 July 2007
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007 Resolved
No copy of contract or proof of enrollment in a consortium. (Owner indicated that the company does work with a consortium.)
Due 21 July 2007
Resolved 17 August 2007
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007 Resolved
Crewmembers not properly training, made aware of drug and alcohol policy, prior to assuming a safety sensitive position. (Employer needs to develop, post, and distribute company policy.)
Due 21 July 2007
Resolved 17 August 2007
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007 Resolved
Employee Assistance Program (EAP) hotline phone number not posted as required by 46 CFR part 16.401.
Due 21 July 2007
Resolved 12 May 2020
Resolution: N/A to this vessel, thisvessel is now a commercial fishing vessel only.
Documentation › Certificates/Documents › FCC SSL
Issued 5 September 2006 Resolved
Properly post current FCC Station License.
Action required: 705 - Other - as specified
Due 5 October 2006
Resolved 11 September 2006
Documentation › Certificates/Documents › Stability Letter
Issued 5 September 2006 Resolved
Properly post vessel's stability letter.
Action required: 705 - Other - as specified
Due 5 October 2006
Resolved 13 November 2006
Resolution: Mailed owner copy of Stability Letter.
Documentation › Logs/Records › Logbook (official)
Issued 5 September 2006 Resolved
Provide current training logbook IAW 46 CFR 185.420.
Action required: 705 - Other - as specified
Due 5 October 2006
Resolved 2 October 2006
Documentation › Logs/Records › Logbook (official)
Issued 5 September 2006 Resolved
Provide lifesaving equipment maintenance records IAW 46 CFR 185.702.
Action required: 705 - Other - as specified
Due 5 October 2006
Resolved 2 October 2006
Documentation › Logs/Records › Logbook (official)
Issued 5 September 2006 Resolved
Provide bridge log IAW 46 CFR 185.702, 46 CFR 185.520, and 46 CFR 185.524.
Action required: 705 - Other - as specified
Due 5 October 2006
Resolved 2 October 2006
Lifesaving › Lifefloat › Retroreflective Material
Issued 5 September 2006 Resolved
Replace retro reflective material.
Action required: 705 - Other - as specified
Due 5 October 2006
Resolved 2 October 2006
Lifesaving › Lifefloat › Markings
Issued 5 September 2006 Resolved
Properly mark life float with max capacity of 22 passengers as per specification label.
Action required: 705 - Other - as specified
Due 5 October 2006
Resolved 13 November 2006
Lifesaving › Lifefloat › Paddle
Issued 5 September 2006 Resolved
Properly label paddle with vessels name.
Action required: 705 - Other - as specified
Due 5 September 2006
Resolved 5 September 2006
Stability › Watertight Integrity › General
Issued 5 September 2006 Resolved
Make bulkhead watertight in way of stbd side aft engine room bulkhead.
Action required: 705 - Other - as specified
Due 5 October 2006
Resolved 2 October 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 September 2006 Resolved
Secure/remove loose wires on topside of MDE, on top side of hydraulic pump on forward part of MDE, on the distribution panel on port side of forward engine room bulkhead, grounding wire on starboard side of MDE, on the aft bulkhead in the lazarette.
Action required: 705 - Other - as specified
Due 5 October 2006
Resolved 2 October 2006
Electrical › Electric Generation Source (service) › Conductor
Issued 5 September 2006 Resolved
Remove old inverter and all associated wiring in space below galley/passenger area.
Action required: 705 - Other - as specified
Due 5 October 2006
Resolved 2 October 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 September 2006 Resolved
Replace/remove electrical box/light switch at the entrance to the engine room.
Action required: 705 - Other - as specified
Due 5 October 2006
Resolved 8 September 2006
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 5 September 2006 Resolved
Replace one (1) adult lifejacket/PFD.
Action required: 705 - Other - as specified
Due 5 October 2006
Resolved 11 October 2006
Resolution: Vessel''s total persons count was reduced on the COI as per owner/operator''s wishes.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 5 September 2006 Resolved
Provide documentation for current NOAA registration.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 11 September 2006
Lifesaving › Lifefloat › Capacity
Issued 5 September 2006 Resolved
Provide primary lifesaving for total number of persons allowed on board. Current life float has max capacity for 22 persons. Vessel is required to have lifesaving for 24 persons.
Action required: 705 - Other - as specified
Due 5 October 2006
Resolved 11 October 2006
Resolution: Vessel''s total persons count was reduced on COI as per owner/operator''s wishes.
Stability › Unintentional Flooding › General
Issued 5 September 2006 Resolved
Prove proper repair of shaft packing prior to carrying passengers.
Action required: 705 - Other - as specified
Due 8 September 2006
Resolved 8 September 2006
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 5 September 2006 Resolved
Replace batteries in water lights for all lifejackets.
Action required: 705 - Other - as specified
Due 5 October 2006
Resolved 2 October 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 September 2006 Resolved
Replace lanyard for the water light attached to the lifebuoy.
Action required: 705 - Other - as specified
Due 5 October 2006
Resolved 2 October 2006
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 September 2006 Resolved
Properly secure water light holder.
Action required: 705 - Other - as specified
Due 5 September 2006
Resolved 5 September 2006
Fire Fighting › Fire Bucket › Lanyard
Issued 5 September 2006 Resolved
Attach proper lanyards to all fire buckets.
Action required: 705 - Other - as specified
Due 5 October 2006
Resolved 2 October 2006
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 5 September 2006 Resolved
Vessel is required to replace FE241 system no later than September 15, 2006. Vessel will be restricted from carrying passengers for hire if requirement is not completed by this date.
Action required: 705 - Other - as specified
Due 15 September 2006
Resolved 14 September 2006
Resolution: Received technician report from Global Fire and Safety.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 September 2006 Resolved
Change vessel's service from "Commercial Fishing Vessel" to "Passenger (inspected)" through the National Vessel Documentation Center.
Action required: 705 - Other - as specified
Due 31 March 2007
Resolved 17 August 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 16 August 2006 Resolved
Provide proof of operation of vessel's fixed fire fighting system. Ensure it has a current inspection of servicing.
Action required: 705 - Other - as specified
Due 16 September 2006
Resolved 21 August 2006
Resolution: Obtained service report from Global Fire & Safety, Inc., stating that vessel''s fixed fire fighting system was in normal operation with a temporary inspection tag given until 9/15/06.
Construction/Loadline › Hull › Keel
Issued 26 April 2005 Resolved
Remove 2 spot circle in yellow under the keel and make it available for inspection.
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 28 April 2005
Resolution: Bay Ship and Yacht repair a small crack at the keel IAW NVIC 8-87.
Engineering › Freshwater Generation System › Pump
Issued 26 April 2005 Resolved
Properly secure the bait pump.
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 5 September 2006
Engineering › Bilge Water Management System › Pump
Issued 26 April 2005 Resolved
Properly secure all electrical bilge pump.
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 5 September 2006
Engineering › Bilge Water Management System › Piping
Issued 26 April 2005 Resolved
Reroute the electrical bilge pump overboard piping for the electric bilge in the void under the passenger space. Install a metallic positive shutoff valve near the thru-hull penetration IAW 46CFR182.520
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 5 September 2006
Construction/Loadline › Structures › End Bulkhead
Issued 26 April 2005 Resolved
Renew the crack in the engine room IAW NVIC 8-87.
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 28 April 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 April 2005 Resolved
Renew the cracks on the collision bulkhead IAW NVIC 8-87.
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 28 April 2005
Engineering › Freshwater Generation System › Piping
Issued 26 April 2005 Resolved
Drain and properly cap off the piping for the forward bait tank.
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 5 September 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 April 2005 Resolved
Properly mount the electric conductors every 18-24 inches IAW 46CFR183.340
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 5 September 2006
Stability › Watertight Integrity › General
Issued 26 April 2005 Resolved
Make the hydraulic hose penetration in the lazarette watertight.
Due 26 May 2005
Resolved 26 April 2005
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 20 May 2004 Resolved
Adjust emergency fuel shut offs to allow valves to close completely.
Due 20 June 2004
Resolved 3 June 2004
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 20 May 2004 Resolved
Put retroreflective tape on 1 child PFD
Due 20 May 2004
Resolved 20 May 2004
Resolution: Corrected on spot.
Lifesaving › Buoyant Apparatus
Issued 20 May 2004 Resolved
Attach weak-link for lifefloat to vessel. LEGACY COMPONENT DESC: Weak-link
Due 20 May 2004
Resolved 20 May 2004
Resolution: Corrected on spot.
Engineering › Freshwater Generation System
Issued 20 May 2004 Resolved
Install hose clamp on fresh water tank vent line. LEGACY COMPONENT DESC: Tank vent
Due 20 May 2004
Resolved 20 May 2004
Resolution: Corrected on spot.
Fire Fighting
Issued 20 May 2004 Resolved
Label and attach lanyard to 1 fire bucket. LEGACY COMPONENT DESC: Fire Bucket
Due 20 May 2004
Resolved 20 May 2004
Resolution: Corrected on spot.
Construction/Loadline › Structures › Scuttle
Issued 20 May 2004 Resolved
Attach lazarette hatch lanyard to vessel in different location to prevent lanyard from fouling around rudder post.
Due 20 May 2004
Resolved 20 May 2004
Resolution: Corrected on spot.
Engineering › Shafting/Propeller Arrangements
Issued 30 April 2003 Resolved
Remove propeller for inspection of shaft keyway prior to placing vessel into water. LEGACY COMPONENT DESC: Propeller Shaft
Action required: 705 - Other - as specified
Due 30 April 2003
Resolved 1 May 2003
Resolution: Propeller was removed and shaft keyway inspected satisfactory.
Deck/Cargo › Mooring/Anchoring
Issued 30 April 2003 Resolved
Tighten port and starboard cleats. LEGACY COMPONENT DESC: Cleats
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 1 May 2003
Resolution: Tightened cleats.
Navigation › Collision/Grounding Avoidance
Issued 30 April 2003 Resolved
Properly mount aft light per COLREGs prior to carrying passengers during night time or reduced visibility. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 1 May 2003
Resolution: Mounted aft light per COLREGs.
Navigation › Collision/Grounding Avoidance
Issued 30 April 2003 Resolved
Provide or replace forward light per COLREGS prior to carrying passengers at night or during reduced visibility. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 1 May 2003
Resolution: Installed proper forward light.
Electrical › Lighting (service)
Issued 30 April 2003 Resolved
Provide cover for engine space light switch. LEGACY COMPONENT DESC: Switch
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 4 June 2003
Resolution: Provided cover.
Stability › Watertight Integrity
Issued 30 April 2003 Resolved
Renew lazarette hatch gasket. LEGACY COMPONENT DESC: Hatch
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 4 June 2003
Resolution: Installed hatch with watertight gasket.
Construction/Loadline › Hull
Issued 30 April 2003 Resolved
Repair in kind, cracked port outboard keelson located in battery space per NVIC 8-87 prior to carrying passengers. LEGACY COMPONENT DESC: Keelson
Action required: 705 - Other - as specified
Resolved 6 May 2003
Resolution: Repaired in accordance with NVIC 8-87.
Stability › Watertight Integrity
Issued 30 April 2003 Resolved
Provide metallic fitting for collision bulkhead for hose used for bow bait tank per 46 CFR 182.40-1. LEGACY COMPONENT DESC: Collision bulkhead
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 4 June 2003
Resolution: Provided metallic fitting.
Engineering › Bilge Water Management System
Issued 30 April 2003 Resolved
Remove excess oil in battery space and anchor space bilges per 46 CFR 176.830. LEGACY COMPONENT DESC: Bilge slop
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 1 May 2003
Resolution: Removed excess oil.
Documentation › Certificates/Documents
Issued 30 April 2003 Resolved
Renew expired Certificate of Documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 4 June 2003
Resolution: Showed receipt for COD payment. Also, called Vessel Docementation Center and they acknowlegded payment.
Electrical › Electric Supply System (service) › Cable
Issued 13 August 2002 Resolved
Properly dead end wires no longer in use in lazzerette.
Due 16 August 2002
Resolved 16 August 2002
Resolution: Unused wires in lazzerette properly terminated.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 13 August 2002 Resolved
Document crew drills and training
Due 16 August 2002
Resolved 16 August 2002
Resolution: Operator provided logbook and is now documenting crew training and drills
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 13 August 2002 Resolved
Provide on board vessel current copy of applicable sections of U.S. Coast Pilot
Due 16 August 2002
Resolved 16 August 2002
Resolution: Coast Pilot available on board vessel
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 13 August 2002 Resolved
Provide and place on board vessel current copy of Coast Guard Light List publication.
Due 16 August 2002
Resolved 16 August 2002
Resolution: Coast guard Light List publication provided on vessel.
Lifesaving › Lifebuoys
Issued 13 August 2002 Resolved
Install non-corrosive detachable clip for waterlight lanyard. LEGACY COMPONENT DESC: Stowage
Due 16 August 2002
Resolved 16 August 2002
Unknown
Issued 11 March 1997 Resolved
PROVIDE INDIVIDUAL BILGE LINES FOR FORWARD TWO COMPARTMENTS PRIOR TO OPERATION.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 11 March 1997 Resolved
RENEW PROPELLOR PRIOR TO OPERATION.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 11 March 1997 Resolved
PROVIDE RETAINING WIRE FOR LAZARETTE HATCH PRIOR TO OPERATION.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 11 March 1997 Resolved
PROPERLY REPAIR ERODED AREA IN FIBERGLASS IN BILGE BELOW BILGE MANIFOLD ACCESS, OUTBOARD OF STARBOARD ENGINE LOG PRIOR TO OPERATION.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 11 March 1997 Resolved
PROVIDE MEANS OF SECURING FORWARD ACCESS HATCH PRIOR TO OPERATION.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 11 March 1997 Resolved
RENEW TO GOOD WOOD PORT SIDE OF CABIN, IN WAY OF WINDOWS AND PILOT HOUSE, WITH ASSOCIATED ROTTEN MEMBERS; PREPARE FOR USCG INSPECTION PRIOR TO REPAIR. THIS TO BE COMPLETED PRIOR TO OPERATION.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 11 March 1997 Resolved
MAKE SECURE STARBOARD COMPANIONWAY GRAB RAIL, IN MIDDLE AT ROTTED WOOD, PRIOR TO OPERATION.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 11 March 1997 Resolved
RENEW OR HYDROSTATICALLY TEST PORT FUEL TANK TO USCG SATISFACTION PRIOR TO OPERATION.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 11 March 1997 Resolved
RECONNECT STARBOARD EMERGENCY FUEL SHUTOFF AND PROVE OPERATION PRIOR TO OPERATION.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 11 March 1997 Resolved
RENEW ENGINEROOM HATCH COVER WHERE ROTTED PRIOR TO OPERATION.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 11 March 1997 Resolved
REMOVE FIBERGLASS FROM PORT BOW BENCH SEAT VERTICAL SUPPORT, WHERE DELAMINATED, AND PREPARE FOR USCG INSPECTION PRIOR TO OPERATION.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 11 March 1997 Resolved
RENEW STARBOARD FUEL TANK PRIOR TO OPERATION.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 11 March 1997 Resolved
PROPERLY LABEL BILGE MANIFOLD PRIOR TO OPERATION.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 11 March 1997 Resolved
RENEW PORT AND STARBOARD PILOT HOUSE DOORS PRIOR TO OPERATION.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 11 March 1997 Resolved
RENEW BILGE MANIFOLD VALVE WITH ERODED STEM PRIOR TO OPERATION.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 11 March 1997 Resolved
REMOVE DELAMINATED FIBERGLASS FROM DECK AT SCUPPERS, AND PREPARE FOR USCG INSPECTION, PRIOR TO OPERATION.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Unknown
Issued 6 June 1996 Resolved
CONDUCT UNDERWAY DRILLS IN THE PRESENCE OF A USCG MARINE INSPECTOR PRIOR TOVESSEL OPERATION.
Condition: Unknown
Due 6 June 1996
Resolved 6 June 1996
Navigation
Issued 3 April 1995 Resolved
REPOSITION ANCHOR LIGHT FOR 360 VISIBILITY, PRIOR TO OPERATING AT NIGHT.
Condition: Unknown
Due 3 April 1995
Resolved 3 April 1995
Construction/Loadline
Issued 3 April 1995 Resolved
REPLACE NUMBER 4 AND NUMBER 8 UNDERDECK STRINGERS IN SECOND COMPARTMENT AFT, PRIOR TO NEXT CREDIT DRYDOCK (03APR97).
Condition: Unknown
Due 20 June 1995
Resolved 20 June 1995
Electrical
Issued 3 April 1995 Resolved
REMOVE ALL 2 PRONG ELECTRICAL CHORDS (UNGROUNDED) FROM VESSEL._x001C_
Condition: Unknown
Due 15 June 1995
Resolved 20 June 1995
Construction/Loadline
Issued 3 April 1995 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVE PROPER OPERATION OF ALL BILGE PUMPS.
Condition: Unknown
Due 15 June 1995
Resolved 20 June 1995
Navigation
Issued 3 April 1995 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVE PROPER OPERATION OF ALL ELECTRONIC NAVIGATION EQUIPMENT.
Condition: Unknown
Due 15 June 1995
Resolved 20 June 1995
Engineering
Issued 3 April 1995 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVE PROPER OPERATION OF MAIN PROPULSION ENGINES.
Condition: Unknown
Due 15 June 1995
Resolved 20 June 1995
Engineering
Issued 3 April 1995 Resolved
HYDROSTATICALLY TEST STARBOARD FUEL TANK.
Condition: Unknown
Due 15 June 1995
Resolved 20 June 1995
Navigation
Issued 3 April 1995 Resolved
PROVIDE GRAY'S HARBOR CHART.
Condition: Unknown
Due 15 June 1995
Resolved 20 June 1995
Lifesaving
Issued 3 April 1995 Resolved
PROVIDE 2 ADDITIONAL OPERABLE WATERLIGHTS, 1 FOR RING BUOY, 1 FOR BUOYANT APPARATUS, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 15 June 1995
Resolved 20 June 1995
Navigation
Issued 3 April 1995 Resolved
PROVIDE CURRENT TIDE TABLES.
Condition: Unknown
Due 15 June 1995
Resolved 20 June 1995
Lifesaving
Issued 3 April 1995 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, RECOIL PAINTER LINE TO BUOYANT APPARTATUS TO ALLOW IT TO FLOAT FREE.
Condition: Unknown
Due 15 June 1995
Resolved 20 June 1995
Accommodation/Occupational Safety
Issued 3 April 1995 Resolved
PEMANENTLY REPAIR STOVE PIPE TOP.
Condition: Unknown
Due 15 June 1995
Resolved 20 June 1995
Accommodation/Occupational Safety
Issued 3 April 1995 Resolved
REPLACE HANDLE ON PORT SIDE BRIDGE DOOR.
Condition: Unknown
Due 15 June 1995
Resolved 20 June 1995
Lifesaving
Issued 3 April 1995 Resolved
PROVIDE 6 VALID SIGNAL FLARES, 3 RED HAND FLARES, 3 ORANGE SMOKE FLARES, PRIOR TO CARRYING PASSENGERS FOR HIRE FOR ROUTES OVER 30 MINUTES LONG.
Condition: Unknown
Due 15 June 1995
Resolved 20 June 1995
Engineering
Issued 3 April 1995 Resolved
CLEAN FUEL OUT OF BILGES AND PUT PLUGS IN FUEL FILTERS, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 15 June 1995
Resolved 20 June 1995
Fire Fighting
Issued 3 April 1995 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE ONE ADDITIONAL CHARGED B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 15 June 1995
Resolved 20 June 1995
Construction/Loadline
Issued 13 June 1994 Resolved
CONDUCTED OPERATIONAL TEST OF BILGE SYSTEM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Engineering
Issued 13 June 1994 Resolved
CONDUCT OPERATIONAL TEST OF NEW ENGINE TO THE SATISFACTION OF THE ATTENDINGMARINE INSPECTOR.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Navigation
Issued 13 June 1994 Resolved
CONDUCT OPERATIONAL TEST OF THE NAVIGATIONAL LIGHTS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Navigation
Issued 13 June 1994 Resolved
CONDUCT OPERATIONAL TEST OF LORAN AND VHF RADIO TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Electrical
Issued 13 June 1994 Resolved
PROPERLY MOUNT ALL ELECTRICAL WIRING.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Electrical
Issued 13 June 1994 Resolved
INSTALL PROPER BATTERY BOX TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Fire Fighting
Issued 13 June 1994 Resolved
PROVIDE PROOF OF SERVICING OF ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Documentation
Issued 13 June 1994 Resolved
PROVIDE PROOF OF ENROLLMENT IN RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Engineering
Issued 13 June 1994 Resolved
INSTALL PROPER REMOTE FUEL SHUTOFFS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Lifesaving
Issued 13 June 1994 Resolved
PROVIDE PROPER TYPE AND AMOUNT OF PFD'S.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Documentation
Issued 13 June 1994 Resolved
PROVIDE AND POST VESSEL STABILITY LETTER.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Documentation
Issued 13 June 1994 Resolved
PROVIDE PROOF OF CURRENT DOCUMENTATION.
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Documentation
Issued 1 June 1993 Resolved
SCHEDULE VESSEL FOR A COAST GUARD SIMPLIFIED STABILITY TEST FOR EXPOSED WATERS.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Engineering
Issued 22 April 1993 Resolved
PROVIDE PROPER FUEL HOSE BETWEEN FUEL TANKS.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Construction/Loadline
Issued 22 April 1993 Resolved
PROVIDE PROTECTIVE GUARD FOR BILGE PUMP.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Navigation
Issued 22 April 1993 Resolved
PROVIDE LIGHT LIST, TIDE TABLE AND COAST PILOT.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Lifesaving
Issued 22 April 1993 Resolved
REPAIR INOPERATIVE WATERLIGHT FOR RING BUOY.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Construction/Loadline
Issued 24 June 1992 Resolved
REPAIR DECK DRAINAGE HOSE WHICH IS LOOSE IN LAZARETTE. DEWATER COMPARTMENTAND IDENTIFY SOURCE OF FUEL LEAK INTO LAZARETTE BILGE.
Condition: Unknown
Due 30 June 1992
Resolved 30 June 1992
Lifesaving
Issued 24 June 1992 Resolved
RENEW NAME OF VESSEL ON ADULT PFD.
Condition: Unknown
Due 30 June 1992
Resolved 30 June 1992
Construction/Loadline
Issued 13 May 1992 Resolved
REPLACE MSD THRU HULL HOSE THAT IS CURRENTLY COVERED W/DUCT TAPE.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Electrical
Issued 13 May 1992 Resolved
PROVIDE FLASHLIGHT FOR EMERGENCY LIGHTING.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Documentation
Issued 13 May 1992 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Construction/Loadline
Issued 13 May 1992 Resolved
PROVIDE DOUBLE HOSE CLAMPS ON THRU HULL VALVE IN LAZARETTE.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Engineering
Issued 13 May 1992 Resolved
INSTALL 30X30 INCH MESH SCREEN OVER PORT SIDE F/O TANK VENT.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Lifesaving
Issued 13 May 1992 Resolved
PAINT BUOYANT APPARATUS INTERNATIONAL ORANGE.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Lifesaving
Issued 13 May 1992 Resolved
PROVIDE TWO (2) USCG APPROVED TYPE I PFD'S.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Lifesaving
Issued 13 May 1992 Resolved
LABEL WITH NUMBER AND TYPE STOWAGE OF PFD'S - INSURE CHILD PFD'S ARE STOWEDSEPARATELY.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Fire Fighting
Issued 13 May 1992 Resolved
PROVIDE USCG APPROVED TYPE B-I FIRE EXTINGUISHER IN PROPER HYDRO.
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Engineering
Issued 22 June 1990 Resolved
PROVIDE BILGE STRAINERS FOR ALL FIXED BILGE PIPING.
Condition: Unknown
Due 22 June 1990
Resolved 22 June 1990
Accommodation/Occupational Safety
Issued 22 June 1990 Resolved
PROPERLY SECURE STOVE.
Condition: Unknown
Due 22 June 1990
Resolved 22 June 1990
Accommodation/Occupational Safety
Issued 20 April 1989 Resolved
PROVIDE MSD HOLDING TANK, AS PER 33 CFR 159.7
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Navigation
Issued 20 April 1989 Resolved
MAKE VESSEL AVAIBLE ONCE BACK IN THE WATER SO OPERATIONAL TESTS CAN BE CONDUCTED ON NAVIGATION (ELECTRONIC) EQUIPMENT AND ON ENGINE AND BILGE PUMP.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Fire Fighting
Issued 19 May 1987 Resolved
PROVIDE ADDITIONAL B-II FIRE EXTINGUISHER FOR GALLEY STOVE.
Condition: Unknown
Due 19 May 1987
Resolved 19 May 1987
Navigation
Issued 19 May 1987 Resolved
PROVE OPERATIONAL TEST OF ALL NAVIGATION ELECTRONICS EQUIPMENT.
Condition: Unknown
Due 19 May 1987
Resolved 19 May 1987
Lifesaving
Issued 19 May 1987 Resolved
PROVIDE 6 ORANGE CG APPROVED FLARES.
Condition: Unknown
Due 19 May 1987
Resolved 19 May 1987
Lifesaving
Issued 19 May 1987 Resolved
REPAIR OR REPLACE WATERLIGHT FOR RING BUOY.
Condition: Unknown
Due 19 May 1987
Resolved 19 May 1987
Navigation
Issued 19 May 1986 Resolved
SECURE WITH NEW BOLTS STBD. STEERING HYDRAULIC SUPPORT BEAM.
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986
Construction/Loadline
Issued 19 May 1986 Resolved
REPAIR WITH NEW WOOD ROTTED DECK PLYWOOD AND ASSOCIATED UNDER DECK LONGITUDINAL AND TRANSVERSE DECK BEAMS WHERE NECESSARY AT STBD. MAIN DECK AFT AND LAZERETTE HATCH.
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986
Lifesaving
Issued 19 May 1986 Resolved
PROVIDE 6 NEW RED HAND HELD FLARES.
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986
Navigation
Issued 19 May 1986 Resolved
REPACK RUDDER STOCK STUFFING TUBE.
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986
Engineering
Issued 19 May 1986 Resolved
SECURE ENGINE ROOM AND LAZERETTE FIXED BILGE PIPING.
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986
Deck/Cargo
Issued 14 November 1985 Resolved
FIX BILGE PIPE BROKEN IN MIDSECTION COMPARTMENT TO MAKE THE BILGE SYSTEM OPERATIVE FOR THE FORWARD COMPARTMENT. MUST BE COMPLETED PRIOR TO CARRYINGPASSENGERS.
Condition: Unknown
Due 14 November 1985
Resolved 14 November 1985
Construction/Loadline
Issued 14 November 1985 Resolved
REPLACE BOTH (2) SIX INCH DIAMETER PORTS ON THE AFT DECK.
Condition: Unknown
Due 14 November 1985
Resolved 14 November 1985

Casualty record · 1

20 December 2019Routine · role: Involved in a Marine Casualty · activity 6891145
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record