← All vessels
PRIMETIME
Commercial Fishing Vessel · Fishing Vessel class · Built 1970s · USCG Southwest District (CGD-SW) · Other hulls named PRIMETIME
PRIMETIME is a 1973 commercial fishing vessel. The Coast Guard has recorded 60 inspections since 1985, most recently in January 2025, along with 196 deficiencies and 1 casualty investigation in 2019.
Records from 1985 to 2025. Most recent: inspection, 5 January 2025.
- Built
- 1973
- Last inspected
- 5 January 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 196 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2019
Identity
548306
KUS54830
47529
Flag
UNITED STATES
303313000
Maury page id
psix-47529
Inspections, by type
…with no type recorded12
Years with a record
26 calendar years (1985–2025)
The 60 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)36.1 ft × 12.1 ft × 5.1 ft
Registered tonnagegross 18 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMODUTECH PLASTICS INC · TACOMA, WA, UNITED STATES · built 1973
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHALF MOON BAY, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 11 August 2026 · expires 31 August 2027
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Regulatory (Subpart C or D), Net Ton
18 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDN4838MMSI 303313000 · active · compulsorily equipped · granted 9 November 2022, expires 9 November 2032
WDG6093MMSI 303313000 · cancelled · compulsorily equipped · granted 14 November 2012, cancelled 2 November 2022
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 60
5 January 2025
Type not recorded
No type recorded · Station Golden Gate · USCG Southwest District (CGD-SW) · Activity 8059692
20 December 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6891145
9 April 2009
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3449289
4 April 2008
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3177717
14 February 2008
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3135189
8 November 2007
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3095838
2 November 2007
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3092167
13 July 2007
Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2991650
9 July 2007
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2989858
25 June 2007
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2973744
21 June 2007
Administrative Inspection
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2970270
2 October 2006
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2789427
28 September 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2789217
5 September 2006
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2757875
21 August 2006
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2755432
16 August 2006
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2750271
29 November 2005
Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 2543032
18 November 2005
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2788067
26 April 2005
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2315736
16 March 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2312654
21 June 2004
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2106224
19 May 2004
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2072519
3 June 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1807990
30 April 2003
Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1779051
13 August 2002
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1661085
20 August 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1469704
2 April 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1060004
28 March 2001
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1406931
30 May 2000
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1404982
21 May 1999
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1429160
29 March 1999
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1411849
3 July 1997
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1113091
11 March 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1416459
6 June 1996
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1428645
3 August 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 56500
3 April 1995
Deficiency Check · Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1355170
13 June 1994
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1431368
6 July 1993
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1157865
24 June 1993
Inclining Experiment
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1156470
1 June 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 839460
22 April 1993
Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1403634
22 February 1993
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1407115
10 November 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 956018
24 June 1992
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1257392
13 May 1992
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 950269
29 April 1991
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 918618
9 April 1991
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1222909
30 October 1990
Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1237840
23 July 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 922028
22 June 1990
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1238390
17 May 1989
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1030786
20 April 1989
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1035180
1 December 1988
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 894917
6 May 1988
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1344790
31 March 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 992378
19 May 1987
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1004274
19 May 1986
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1306149
27 March 1986
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1305504
14 November 1985
Credit Drydock
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 990701
14 May 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1288427
Deficiency record · 196
Documentation › Logs/Records › Drug Test Records
Issued 9 April 2009
Resolved
Company could not provide a Substance Abuse Professional (SAP) name and contact information as required by 49 CFR 40.287
Documentation › Logs/Records › Drug Test Records
Issued 9 April 2009
Resolved
Owner did not have a copy of 2008 MIS report at the time of the audit as required by 46 CFR 16.500.
Documentation › Certificates/Documents › FCC SSL
Issued 4 April 2008
Resolved
Provide current FCC Station License, FCC Safety License, Marine Radio Operator Permit for Master.
Documentation › Certificates/Documents › Stability Letter
Issued 4 April 2008
Resolved
Properly post stability letter.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2008
Resolved
Properly support wiring in engine room with metallic supports IAW 46CFR183.340(b)(4).
Navigation › Piloting/Steering › Marine Charts
Issued 4 April 2008
Resolved
Provide marine chart for vessel's operating area.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 4 April 2008
Resolved
Properly secure bilge pump in engine room.
Engineering › Steering Gear System › Hydraulic Hose
Issued 4 April 2008
Resolved
Repair leaks on hydraulic lines for steering system under pilot house console.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 4 April 2008
Resolved
Correct vessel NOAA EPIRB registration form with owners e-mail address.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 4 April 2008
Resolved
Provide log entries for monthly EPIRB tests, NOAA registration information, EPIRB battery expiration/installation date, and hydrostatic release expiration date.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2008
Resolved
Provide supports for bilge pump and high water alarm wiring in lazarette.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 4 April 2008
Resolved
Replace all of the batteries for the life jacket water lights. Batteries are expired.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 April 2008
Resolved
Remove or cap the pipe leading through the forward engine room bulkhead to the amidships bilge area to ensure bulkhead is water tight.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 4 April 2008
Resolved
Provide 7 adult type I PFD's for a total of 22 adult PFD's onboard vessel.
Electrical › Electric Supply System (service) › Cable
Issued 4 April 2008
Resolved
Replace the frayed battery cable in the forward most cable box in the amidships bilge area with marine grade battery cables.
Engineering › Steering Gear System › Hydraulic Hose
Issued 4 April 2008
Resolved
Repair hydraulic leak in aft starboard corner of the amidships compartment. Hydraulic lines for crab pot winch is leaking all over the electrical wiring/cables in compartment.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 4 April 2008
Resolved
Replace expired hydrostatic release for EPIRB. Current hydrostatic release will expire in April 2008.
Stability › Weathertight Integrity › General
Issued 14 February 2008
Resolved
Provide securing devices for engine room hatch cover IAW 46 CFR 174.220.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 14 February 2008
Resolved
Properly lock/secure overboard discharge for sewage tank. Valve was found in the open position at the mooring in Emeryville.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 14 February 2008
Resolved
Provide proper/current lifesaving maintenance logs.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 14 February 2008
Resolved
Submit plan proposal for work lights mounted on top of pilot house. Lights shall not be used until plans are approved, lights are properly installed, and the installation is approved by attending marine inspector.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 14 February 2008
Resolved
Conduct DAPI audit with D11 DAPI, [name withheld] must be reviewed and compliant to the satisfaction of the D11 DAPI Auditor. Deficiency must be cleared prior to carrying passengers.
Operations/Management › Drills/Instruction › Fire
Issued 14 February 2008
Resolved
Conduct a satisfactory fire drill prior to carrying passengers.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
Company program missing as required by 46 CFR part 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
No acceptable proof of five-panel testing as required by 49 CFR 40.85.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
Positive drug test records not kept for 5 years as required by 46 CFR 16.260.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
Negative test results not maintained for 1 year as required by 46 CFR 16.260.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
Company currently does not receive result/exemptions for pre-employment testing prior to an individual working in a safety sensitive position, as required by 46 CFR 16.210.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
Documentation of pre-employment testing not kept for entire employment period as required by 46 CFR 16.260.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
Drug and alcohol history checks not being completed as required by 49 CFR 40.25.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
Random drug testing was found to not be conducted in accordance with 46 CFR 16.230. Company owner was unaware of any employee being randomly tested.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
Statistically based method not currently being used to determine when random testing takes place as required by 46 CFR part 16.230. Owner had no knowledge, or proof, that any of his employees had ever been randomly tested.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
Testing is not spread equally throughout the year as required by 46 CFR 16.230. No record of random drug testing having ever been conducted.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
All required personnel are not in the random drug testing pool as required by 46 CFR 16.230. Based on fragmented paperwork it apears that two employees no longer employed are still on the list and the two employees who do actually work do not have pre-employment tests on record.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
Arrangements not made for post-casualty testing as required by 46 CFR part 16.240. Owner did not remember time limitations for testing and alcohol testing devices were not onboard two of the three vessels.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
Alcohol testing devices not onboard two of the three vessels as required by 46 CFR part 4.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
Employee assistance program statement not posted as required by 46 CFR 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
Employee Assistance Program (EAP) hotline phone number not posted as required by 46 CFR part 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
Supervisors had not received 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR part 16.401. Owner provided signed list provided by [name withheld] but could not articulate what the training source was, where it had came from, or what the training had entailed.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information to make available to employees, per 49 CFR 40.287.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
No copy of contract or proof of enrollment in Consortium as required by 46 CFR 16. Owner unsure as to whether his company is a part of the National Testing Association, Inc. or Maritime Consortium.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
Covered employees list not up to date in accordance with 46 CFR 16.230. List presented was not recent, included two persons owner said were no longer employed.
Documentation › Logs/Records › Drug Test Records
Issued 8 November 2007
Resolved
Security of records not maintained in accordance with 49 CFR 40.333. Owner indicated he only has his own drug test results and believes employees have received and maintained copies of their own pre-employement test results.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 2 November 2007
Resolved
Replace two child size Type I PFD's saturated with hydraulic oil.
Electrical › Electric Supply System (service) › Cable
Issued 13 July 2007
Resolved
Repair exposed electrical wire to bilge bump in way of lazarette.
Stability › Watertight Integrity › General
Issued 13 July 2007
Resolved
Seal cable penetration in bulkhead between lazarette and engine room making it watertight.
Engineering › Fuel Oil Service System › Filter
Issued 13 July 2007
Resolved
Remount hanging fuel filter housing on main engine.
Operations/Management › Passenger Operations › Safety Orientation
Issued 9 July 2007
Resolved
Vessel restricted from carrying passengers for hire until a credit hull exam is completed by an attending Marine Inspector.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 25 June 2007
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007
Resolved
Company policy missing as required by 46 CFR part 16.401. (Sample policy provided.)
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007
Resolved
No acceptable proof of five-panel testing as required by 49 CFR 40.85.
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007
Resolved
Company currently does not conduct any pre-employment tests on employees, as required by 46 CFR 16.210.
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007
Resolved
Drug and alcohol history checks not being completed as required by 49 CFR 40.25.
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007
Resolved
Statistically based method not currently being used to determine when random testing takes place. (Employees currently get tested every May.)
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007
Resolved
Testing is not spread equally throughout the year as required by 46 CFR 16.230. (Employees currently tested every May.)
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007
Resolved
All required personnel are not in the random drug testing pool as required by 46 CFR 16.230. (Company currently only updates list annually when prompted by consortium.)
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007
Resolved
Arrangements not made for post-casualty testing as required by 46 CFR part 16.240. (Employer needs to know where collection facilities are and what hours/days they are open.)
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007
Resolved
Arrangements not made for reasonable testing as required by 46 CFR part 16.250. (Employer needs to know where collection facilities are and what hours/days they are open.)
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007
Resolved
Employee Assistance Program (EAP) hotline phone number not posted as required by 46 CFR part 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007
Resolved
Supervisors had not received 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR part 16.401.
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007
Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information to make available to employees, per 49 CFR 40.287.
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007
Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007
Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007
Resolved
No copy of contract or proof of enrollment in a consortium. (Owner indicated that the company does work with a consortium.)
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007
Resolved
Crewmembers not properly training, made aware of drug and alcohol policy, prior to assuming a safety sensitive position. (Employer needs to develop, post, and distribute company policy.)
Documentation › Logs/Records › Drug Test Records
Issued 21 June 2007
Resolved
Employee Assistance Program (EAP) hotline phone number not posted as required by 46 CFR part 16.401.
Documentation › Certificates/Documents › FCC SSL
Issued 5 September 2006
Resolved
Properly post current FCC Station License.
Documentation › Certificates/Documents › Stability Letter
Issued 5 September 2006
Resolved
Properly post vessel's stability letter.
Documentation › Logs/Records › Logbook (official)
Issued 5 September 2006
Resolved
Provide current training logbook IAW 46 CFR 185.420.
Documentation › Logs/Records › Logbook (official)
Issued 5 September 2006
Resolved
Provide lifesaving equipment maintenance records IAW 46 CFR 185.702.
Documentation › Logs/Records › Logbook (official)
Issued 5 September 2006
Resolved
Provide bridge log IAW 46 CFR 185.702, 46 CFR 185.520, and 46 CFR 185.524.
Lifesaving › Lifefloat › Retroreflective Material
Issued 5 September 2006
Resolved
Replace retro reflective material.
Lifesaving › Lifefloat › Markings
Issued 5 September 2006
Resolved
Properly mark life float with max capacity of 22 passengers as per specification label.
Lifesaving › Lifefloat › Paddle
Issued 5 September 2006
Resolved
Properly label paddle with vessels name.
Stability › Watertight Integrity › General
Issued 5 September 2006
Resolved
Make bulkhead watertight in way of stbd side aft engine room bulkhead.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 September 2006
Resolved
Secure/remove loose wires on topside of MDE, on top side of hydraulic pump on forward part of MDE, on the distribution panel on port side of forward engine room bulkhead, grounding wire on starboard side of MDE, on the aft bulkhead in the lazarette.
Electrical › Electric Generation Source (service) › Conductor
Issued 5 September 2006
Resolved
Remove old inverter and all associated wiring in space below galley/passenger area.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 September 2006
Resolved
Replace/remove electrical box/light switch at the entrance to the engine room.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 5 September 2006
Resolved
Replace one (1) adult lifejacket/PFD.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 5 September 2006
Resolved
Provide documentation for current NOAA registration.
Lifesaving › Lifefloat › Capacity
Issued 5 September 2006
Resolved
Provide primary lifesaving for total number of persons allowed on board. Current life float has max capacity for 22 persons. Vessel is required to have lifesaving for 24 persons.
Stability › Unintentional Flooding › General
Issued 5 September 2006
Resolved
Prove proper repair of shaft packing prior to carrying passengers.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 5 September 2006
Resolved
Replace batteries in water lights for all lifejackets.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 September 2006
Resolved
Replace lanyard for the water light attached to the lifebuoy.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 September 2006
Resolved
Properly secure water light holder.
Fire Fighting › Fire Bucket › Lanyard
Issued 5 September 2006
Resolved
Attach proper lanyards to all fire buckets.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 5 September 2006
Resolved
Vessel is required to replace FE241 system no later than September 15, 2006. Vessel will be restricted from carrying passengers for hire if requirement is not completed by this date.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 September 2006
Resolved
Change vessel's service from "Commercial Fishing Vessel" to "Passenger (inspected)" through the National Vessel Documentation Center.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 16 August 2006
Resolved
Provide proof of operation of vessel's fixed fire fighting system. Ensure it has a current inspection of servicing.
Construction/Loadline › Hull › Keel
Issued 26 April 2005
Resolved
Remove 2 spot circle in yellow under the keel and make it available for inspection.
Engineering › Freshwater Generation System › Pump
Issued 26 April 2005
Resolved
Properly secure the bait pump.
Engineering › Bilge Water Management System › Pump
Issued 26 April 2005
Resolved
Properly secure all electrical bilge pump.
Engineering › Bilge Water Management System › Piping
Issued 26 April 2005
Resolved
Reroute the electrical bilge pump overboard piping for the electric bilge in the void under the passenger space. Install a metallic positive shutoff valve near the thru-hull penetration IAW 46CFR182.520
Construction/Loadline › Structures › End Bulkhead
Issued 26 April 2005
Resolved
Renew the crack in the engine room IAW NVIC 8-87.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 April 2005
Resolved
Renew the cracks on the collision bulkhead IAW NVIC 8-87.
Engineering › Freshwater Generation System › Piping
Issued 26 April 2005
Resolved
Drain and properly cap off the piping for the forward bait tank.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 April 2005
Resolved
Properly mount the electric conductors every 18-24 inches IAW 46CFR183.340
Stability › Watertight Integrity › General
Issued 26 April 2005
Resolved
Make the hydraulic hose penetration in the lazarette watertight.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 20 May 2004
Resolved
Adjust emergency fuel shut offs to allow valves to close completely.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 20 May 2004
Resolved
Put retroreflective tape on 1 child PFD
Lifesaving › Buoyant Apparatus
Issued 20 May 2004
Resolved
Attach weak-link for lifefloat to vessel. LEGACY COMPONENT DESC: Weak-link
Engineering › Freshwater Generation System
Issued 20 May 2004
Resolved
Install hose clamp on fresh water tank vent line. LEGACY COMPONENT DESC: Tank vent
Fire Fighting
Issued 20 May 2004
Resolved
Label and attach lanyard to 1 fire bucket. LEGACY COMPONENT DESC: Fire Bucket
Construction/Loadline › Structures › Scuttle
Issued 20 May 2004
Resolved
Attach lazarette hatch lanyard to vessel in different location to prevent lanyard from fouling around rudder post.
Engineering › Shafting/Propeller Arrangements
Issued 30 April 2003
Resolved
Remove propeller for inspection of shaft keyway prior to placing vessel into water. LEGACY COMPONENT DESC: Propeller Shaft
Deck/Cargo › Mooring/Anchoring
Issued 30 April 2003
Resolved
Tighten port and starboard cleats. LEGACY COMPONENT DESC: Cleats
Navigation › Collision/Grounding Avoidance
Issued 30 April 2003
Resolved
Properly mount aft light per COLREGs prior to carrying passengers during night time or reduced visibility. LEGACY COMPONENT DESC: Navigation Lights
Navigation › Collision/Grounding Avoidance
Issued 30 April 2003
Resolved
Provide or replace forward light per COLREGS prior to carrying passengers at night or during reduced visibility. LEGACY COMPONENT DESC: Navigation Lights
Electrical › Lighting (service)
Issued 30 April 2003
Resolved
Provide cover for engine space light switch. LEGACY COMPONENT DESC: Switch
Stability › Watertight Integrity
Issued 30 April 2003
Resolved
Renew lazarette hatch gasket. LEGACY COMPONENT DESC: Hatch
Construction/Loadline › Hull
Issued 30 April 2003
Resolved
Repair in kind, cracked port outboard keelson located in battery space per NVIC 8-87 prior to carrying passengers. LEGACY COMPONENT DESC: Keelson
Stability › Watertight Integrity
Issued 30 April 2003
Resolved
Provide metallic fitting for collision bulkhead for hose used for bow bait tank per 46 CFR 182.40-1. LEGACY COMPONENT DESC: Collision bulkhead
Engineering › Bilge Water Management System
Issued 30 April 2003
Resolved
Remove excess oil in battery space and anchor space bilges per 46 CFR 176.830. LEGACY COMPONENT DESC: Bilge slop
Documentation › Certificates/Documents
Issued 30 April 2003
Resolved
Renew expired Certificate of Documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Electrical › Electric Supply System (service) › Cable
Issued 13 August 2002
Resolved
Properly dead end wires no longer in use in lazzerette.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 13 August 2002
Resolved
Document crew drills and training
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 13 August 2002
Resolved
Provide on board vessel current copy of applicable sections of U.S. Coast Pilot
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 13 August 2002
Resolved
Provide and place on board vessel current copy of Coast Guard Light List publication.
Lifesaving › Lifebuoys
Issued 13 August 2002
Resolved
Install non-corrosive detachable clip for waterlight lanyard. LEGACY COMPONENT DESC: Stowage
Unknown
Issued 11 March 1997
Resolved
PROVIDE INDIVIDUAL BILGE LINES FOR FORWARD TWO COMPARTMENTS PRIOR TO OPERATION.
Unknown
Issued 11 March 1997
Resolved
RENEW PROPELLOR PRIOR TO OPERATION.
Unknown
Issued 11 March 1997
Resolved
PROVIDE RETAINING WIRE FOR LAZARETTE HATCH PRIOR TO OPERATION.
Unknown
Issued 11 March 1997
Resolved
PROPERLY REPAIR ERODED AREA IN FIBERGLASS IN BILGE BELOW BILGE MANIFOLD ACCESS, OUTBOARD OF STARBOARD ENGINE LOG PRIOR TO OPERATION.
Unknown
Issued 11 March 1997
Resolved
PROVIDE MEANS OF SECURING FORWARD ACCESS HATCH PRIOR TO OPERATION.
Unknown
Issued 11 March 1997
Resolved
RENEW TO GOOD WOOD PORT SIDE OF CABIN, IN WAY OF WINDOWS AND PILOT HOUSE, WITH ASSOCIATED ROTTEN MEMBERS; PREPARE FOR USCG INSPECTION PRIOR TO REPAIR. THIS TO BE COMPLETED PRIOR TO OPERATION.
Unknown
Issued 11 March 1997
Resolved
MAKE SECURE STARBOARD COMPANIONWAY GRAB RAIL, IN MIDDLE AT ROTTED WOOD, PRIOR TO OPERATION.
Unknown
Issued 11 March 1997
Resolved
RENEW OR HYDROSTATICALLY TEST PORT FUEL TANK TO USCG SATISFACTION PRIOR TO OPERATION.
Unknown
Issued 11 March 1997
Resolved
RECONNECT STARBOARD EMERGENCY FUEL SHUTOFF AND PROVE OPERATION PRIOR TO OPERATION.
Unknown
Issued 11 March 1997
Resolved
RENEW ENGINEROOM HATCH COVER WHERE ROTTED PRIOR TO OPERATION.
Unknown
Issued 11 March 1997
Resolved
REMOVE FIBERGLASS FROM PORT BOW BENCH SEAT VERTICAL SUPPORT, WHERE DELAMINATED, AND PREPARE FOR USCG INSPECTION PRIOR TO OPERATION.
Unknown
Issued 11 March 1997
Resolved
RENEW STARBOARD FUEL TANK PRIOR TO OPERATION.
Unknown
Issued 11 March 1997
Resolved
PROPERLY LABEL BILGE MANIFOLD PRIOR TO OPERATION.
Unknown
Issued 11 March 1997
Resolved
RENEW PORT AND STARBOARD PILOT HOUSE DOORS PRIOR TO OPERATION.
Unknown
Issued 11 March 1997
Resolved
RENEW BILGE MANIFOLD VALVE WITH ERODED STEM PRIOR TO OPERATION.
Unknown
Issued 11 March 1997
Resolved
REMOVE DELAMINATED FIBERGLASS FROM DECK AT SCUPPERS, AND PREPARE FOR USCG INSPECTION, PRIOR TO OPERATION.
Unknown
Issued 6 June 1996
Resolved
CONDUCT UNDERWAY DRILLS IN THE PRESENCE OF A USCG MARINE INSPECTOR PRIOR TOVESSEL OPERATION.
Navigation
Issued 3 April 1995
Resolved
REPOSITION ANCHOR LIGHT FOR 360 VISIBILITY, PRIOR TO OPERATING AT NIGHT.
Construction/Loadline
Issued 3 April 1995
Resolved
REPLACE NUMBER 4 AND NUMBER 8 UNDERDECK STRINGERS IN SECOND COMPARTMENT AFT, PRIOR TO NEXT CREDIT DRYDOCK (03APR97).
Electrical
Issued 3 April 1995
Resolved
REMOVE ALL 2 PRONG ELECTRICAL CHORDS (UNGROUNDED) FROM VESSEL._x001C_
Construction/Loadline
Issued 3 April 1995
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVE PROPER OPERATION OF ALL BILGE PUMPS.
Navigation
Issued 3 April 1995
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVE PROPER OPERATION OF ALL ELECTRONIC NAVIGATION EQUIPMENT.
Engineering
Issued 3 April 1995
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVE PROPER OPERATION OF MAIN PROPULSION ENGINES.
Engineering
Issued 3 April 1995
Resolved
HYDROSTATICALLY TEST STARBOARD FUEL TANK.
Navigation
Issued 3 April 1995
Resolved
PROVIDE GRAY'S HARBOR CHART.
Lifesaving
Issued 3 April 1995
Resolved
PROVIDE 2 ADDITIONAL OPERABLE WATERLIGHTS, 1 FOR RING BUOY, 1 FOR BUOYANT APPARATUS, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Navigation
Issued 3 April 1995
Resolved
PROVIDE CURRENT TIDE TABLES.
Lifesaving
Issued 3 April 1995
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, RECOIL PAINTER LINE TO BUOYANT APPARTATUS TO ALLOW IT TO FLOAT FREE.
Accommodation/Occupational Safety
Issued 3 April 1995
Resolved
PEMANENTLY REPAIR STOVE PIPE TOP.
Accommodation/Occupational Safety
Issued 3 April 1995
Resolved
REPLACE HANDLE ON PORT SIDE BRIDGE DOOR.
Lifesaving
Issued 3 April 1995
Resolved
PROVIDE 6 VALID SIGNAL FLARES, 3 RED HAND FLARES, 3 ORANGE SMOKE FLARES, PRIOR TO CARRYING PASSENGERS FOR HIRE FOR ROUTES OVER 30 MINUTES LONG.
Engineering
Issued 3 April 1995
Resolved
CLEAN FUEL OUT OF BILGES AND PUT PLUGS IN FUEL FILTERS, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Fire Fighting
Issued 3 April 1995
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE ONE ADDITIONAL CHARGED B-II FIRE EXTINGUISHER.
Construction/Loadline
Issued 13 June 1994
Resolved
CONDUCTED OPERATIONAL TEST OF BILGE SYSTEM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Engineering
Issued 13 June 1994
Resolved
CONDUCT OPERATIONAL TEST OF NEW ENGINE TO THE SATISFACTION OF THE ATTENDINGMARINE INSPECTOR.
Navigation
Issued 13 June 1994
Resolved
CONDUCT OPERATIONAL TEST OF THE NAVIGATIONAL LIGHTS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Navigation
Issued 13 June 1994
Resolved
CONDUCT OPERATIONAL TEST OF LORAN AND VHF RADIO TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Electrical
Issued 13 June 1994
Resolved
PROPERLY MOUNT ALL ELECTRICAL WIRING.
Electrical
Issued 13 June 1994
Resolved
INSTALL PROPER BATTERY BOX TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Fire Fighting
Issued 13 June 1994
Resolved
PROVIDE PROOF OF SERVICING OF ALL PORTABLE FIRE EXTINGUISHERS.
Documentation
Issued 13 June 1994
Resolved
PROVIDE PROOF OF ENROLLMENT IN RANDOM DRUG TESTING PROGRAM.
Engineering
Issued 13 June 1994
Resolved
INSTALL PROPER REMOTE FUEL SHUTOFFS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Lifesaving
Issued 13 June 1994
Resolved
PROVIDE PROPER TYPE AND AMOUNT OF PFD'S.
Documentation
Issued 13 June 1994
Resolved
PROVIDE AND POST VESSEL STABILITY LETTER.
Documentation
Issued 13 June 1994
Resolved
PROVIDE PROOF OF CURRENT DOCUMENTATION.
Documentation
Issued 1 June 1993
Resolved
SCHEDULE VESSEL FOR A COAST GUARD SIMPLIFIED STABILITY TEST FOR EXPOSED WATERS.
Engineering
Issued 22 April 1993
Resolved
PROVIDE PROPER FUEL HOSE BETWEEN FUEL TANKS.
Construction/Loadline
Issued 22 April 1993
Resolved
PROVIDE PROTECTIVE GUARD FOR BILGE PUMP.
Navigation
Issued 22 April 1993
Resolved
PROVIDE LIGHT LIST, TIDE TABLE AND COAST PILOT.
Lifesaving
Issued 22 April 1993
Resolved
REPAIR INOPERATIVE WATERLIGHT FOR RING BUOY.
Construction/Loadline
Issued 24 June 1992
Resolved
REPAIR DECK DRAINAGE HOSE WHICH IS LOOSE IN LAZARETTE. DEWATER COMPARTMENTAND IDENTIFY SOURCE OF FUEL LEAK INTO LAZARETTE BILGE.
Lifesaving
Issued 24 June 1992
Resolved
RENEW NAME OF VESSEL ON ADULT PFD.
Construction/Loadline
Issued 13 May 1992
Resolved
REPLACE MSD THRU HULL HOSE THAT IS CURRENTLY COVERED W/DUCT TAPE.
Electrical
Issued 13 May 1992
Resolved
PROVIDE FLASHLIGHT FOR EMERGENCY LIGHTING.
Documentation
Issued 13 May 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Construction/Loadline
Issued 13 May 1992
Resolved
PROVIDE DOUBLE HOSE CLAMPS ON THRU HULL VALVE IN LAZARETTE.
Engineering
Issued 13 May 1992
Resolved
INSTALL 30X30 INCH MESH SCREEN OVER PORT SIDE F/O TANK VENT.
Lifesaving
Issued 13 May 1992
Resolved
PAINT BUOYANT APPARATUS INTERNATIONAL ORANGE.
Lifesaving
Issued 13 May 1992
Resolved
PROVIDE TWO (2) USCG APPROVED TYPE I PFD'S.
Lifesaving
Issued 13 May 1992
Resolved
LABEL WITH NUMBER AND TYPE STOWAGE OF PFD'S - INSURE CHILD PFD'S ARE STOWEDSEPARATELY.
Fire Fighting
Issued 13 May 1992
Resolved
PROVIDE USCG APPROVED TYPE B-I FIRE EXTINGUISHER IN PROPER HYDRO.
Engineering
Issued 22 June 1990
Resolved
PROVIDE BILGE STRAINERS FOR ALL FIXED BILGE PIPING.
Accommodation/Occupational Safety
Issued 22 June 1990
Resolved
PROPERLY SECURE STOVE.
Accommodation/Occupational Safety
Issued 20 April 1989
Resolved
PROVIDE MSD HOLDING TANK, AS PER 33 CFR 159.7
Navigation
Issued 20 April 1989
Resolved
MAKE VESSEL AVAIBLE ONCE BACK IN THE WATER SO OPERATIONAL TESTS CAN BE CONDUCTED ON NAVIGATION (ELECTRONIC) EQUIPMENT AND ON ENGINE AND BILGE PUMP.
Fire Fighting
Issued 19 May 1987
Resolved
PROVIDE ADDITIONAL B-II FIRE EXTINGUISHER FOR GALLEY STOVE.
Navigation
Issued 19 May 1987
Resolved
PROVE OPERATIONAL TEST OF ALL NAVIGATION ELECTRONICS EQUIPMENT.
Lifesaving
Issued 19 May 1987
Resolved
PROVIDE 6 ORANGE CG APPROVED FLARES.
Lifesaving
Issued 19 May 1987
Resolved
REPAIR OR REPLACE WATERLIGHT FOR RING BUOY.
Navigation
Issued 19 May 1986
Resolved
SECURE WITH NEW BOLTS STBD. STEERING HYDRAULIC SUPPORT BEAM.
Construction/Loadline
Issued 19 May 1986
Resolved
REPAIR WITH NEW WOOD ROTTED DECK PLYWOOD AND ASSOCIATED UNDER DECK LONGITUDINAL AND TRANSVERSE DECK BEAMS WHERE NECESSARY AT STBD. MAIN DECK AFT AND LAZERETTE HATCH.
Lifesaving
Issued 19 May 1986
Resolved
PROVIDE 6 NEW RED HAND HELD FLARES.
Navigation
Issued 19 May 1986
Resolved
REPACK RUDDER STOCK STUFFING TUBE.
Engineering
Issued 19 May 1986
Resolved
SECURE ENGINE ROOM AND LAZERETTE FIXED BILGE PIPING.
Deck/Cargo
Issued 14 November 1985
Resolved
FIX BILGE PIPE BROKEN IN MIDSECTION COMPARTMENT TO MAKE THE BILGE SYSTEM OPERATIVE FOR THE FORWARD COMPARTMENT. MUST BE COMPLETED PRIOR TO CARRYINGPASSENGERS.
Construction/Loadline
Issued 14 November 1985
Resolved
REPLACE BOTH (2) SIX INCH DIAMETER PORTS ON THE AFT DECK.
Casualty record · 1
20 December 2019Routine · role: Involved in a Marine Casualty · activity 6891145
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.