Records from 2016 to 2026. Most recent: inspection, 18 March 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
18 March 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8318707
3 December 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8276568
5 March 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8084701
26 March 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7885474
6 December 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7834769
7 March 2023
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7643288
23 March 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7421793
18 March 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7420995
8 December 2021
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7360223
4 May 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7189053
11 March 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6923370
3 December 2019
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6862543
11 September 2019
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6809445
11 March 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6636202
28 February 2018
COI Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6362140
30 November 2017
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6313672
3 March 2017
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6099978
4 March 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5822573
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 March 2025
Resolved
46 CFR 183.10-10; [...] distribution panels shall be dripproof protected. Driproof protected means that equipment is so constructed and protected that its successful operation is not interfered with when subject to falling moisture, and uninsulated parts cannot be inadvertently touched or approached nearer than a safe distance. 120v distribution panel had open breaker slots. Vessel to install blanks or spare breakers to fully enclose inner wiring.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 2 April 2025
Resolution: Provided photos showing blanks in place.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 March 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel stern light inop during inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 2 April 2025
Resolution: Photo of functional stern light.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 March 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems. IBA off vessel for annual servicing. Vessel to send proof of installation and annual servicing when completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2025
Resolved 2 April 2025
Resolution: Liferaft servicing reports received.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 March 2025
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: [...] For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel attested to annual servicing, but no documentation from the servicing tech other than tags on the bottles. Vessel to supply documentation from servicing tech for components tested.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2025
Resolved 2 April 2025
Resolution: Received servicing report for fixed co2 system.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 5 March 2025
Resolved
47 CFR 80.903; Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessel radio safety certificate expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2025
Resolved 2 April 2025
Resolution: Received report for FCC certifications
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 March 2024
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMC. Marine inspector observed alcohol testing devices were not readily accessible due to being expired.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2024
Resolved 1 April 2024
Resolution: Recieved photo of new alcohol testing devices. Deficiency cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 March 2024
Resolved
At least one ring life buoy must be fitted with a lifeline. Marine inspector observed lifeline for starboard bridge wing life ring buoy to be heavily deteriorated by UV light and of insufficient length.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2024
Resolved 1 April 2024
Resolution: Recieved photo of new ring life buoy lifeline. Deficiency cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 March 2024
Resolved
Each life jacket carried on board the vessel must be marked in accordance with 46 CFR § 185.604. Marine inspector observed 01 child sized life without a mark of the vessel name.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2024
Resolved 1 April 2024
Resolution: Recieved photo of child life jacket with approved marking. Deficiency cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2023
Resolved
Provide evidence of pre-employment and enrolment in random chemical testing for all crewmembers
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 7 April 2023
Resolved 21 March 2023
Resolution: Received documentation of crew chemical testing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 March 2022
Resolved
Missing 01 child lifejacket
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 6 April 2022
Resolution: Replaced missing childs life jacket.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 March 2022
Resolved
Missing vessel name and hailing port on stern.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 6 April 2022
Resolution: Name and hailing port labeled on stern.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 December 2021
Resolved
Provide one line electrical diagram to MSC.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2022
Resolved 11 December 2023
Resolution: Owner in communication with MSC for final drawing approval.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2021
Resolved
Provide one line electrical diagram prior to completion on next dry dock exam, 31DEC21
Action required: 705 - Other - as specified
Due 31 December 2021
Resolved 14 December 2021
Resolution: Member provided unit with one line diagram.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 March 2020
Resolved
An alarm for a fixed gas fire extinguishing system must be clearly and conspicuously marked: "WHEN ALARM SOUNDS-VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED". Noted that the alarm in the engineroom is not labeled. Required to label.
46CFR185.612(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2020
Resolved 17 March 2020
Resolution: Received pictures from operator of CO2 signage. All sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 March 2020
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: Spaces storing carbon dioxide (1): "CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION". (2) Spaces protected by carbon dioxide: "CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING." Noted that the entrance to the engineroom that is protected by carbon dioxide and the space storing the cylinders is not marked. Required to mark.
46CFR185.612(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2020
Resolved 17 March 2020
Resolution: Received pictures from operator of CO2 signage. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 September 2019
Resolved
The owner/operator shall provide adequate number of watchmen patrol throughout the vessel during nighttime whether or not the Vessel is underway. 46CFR 185.410
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 6 November 2019
Resolution: Operator provided updated watch schedule for underway overnight operations
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 September 2019
Resolved
Vessel must have at least one fire axe located In or adjacent to primary operating station. 46 CFR 181.600
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 6 November 2019
Resolution: Vessel is under 65 feet and not required to comply with this regulation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 March 2019
Resolved
All 42 adult life jackets unserviceable. Provide 42 adult life jackets with proper markings. 46 CFR 180.71
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2019
Resolved 20 March 2019
Resolution: Replaced with new adult lifejackets.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 March 2019
Resolved
Radio station authorization expired. Provide valid station authorization certificate. 46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2019
Resolved 20 March 2019
Resolution: Had FCC the whole time.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 March 2019
Resolved
Multiple expired items in first aid kit. Provide approved kit or equivalent. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2019
Resolved 20 March 2019
Resolution: Replaced with new first aid kit.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 28 February 2018
Resolved
Provide evidence of pre-employment chemical testing for all crewmembers. 46 CFR 16.210
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 29 March 2018
Resolution: CAPT emailed picture of addressed descrepancy. All Sat.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 28 February 2018
Resolved
Provide comprehensive list of all crew members enrolled in consortium. 46 CFR 16.230(g)
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 29 March 2018
Resolution: CAPT emailed picture of addressed descrepancy. All Sat.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 28 February 2018
Resolved
Install exit signs on passenger accommodation deck near both exits in clearly legible letters at least 02 inches high that reads: "EMERGENCY EXIT, KEEP CLEAR". 46 CFR 185.606
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 5 March 2018
Resolution: CAPT emailed picture of addressed descrepancy. All Sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 February 2018
Resolved
Install unexpired battery in life ring light. 46 CFR 180.70(d)
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 5 March 2018
Resolution: CAPT emailed picture of addressed descrepancy. All Sat.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 28 February 2018
Resolved
Label life ring with vessel's name. 46 CFR 185.604(b)
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 5 March 2018
Resolution: CAPT emailed picture of addressed descrepancy. All Sat.