MAURY USCG vessel records Sign in
← All vessels

SNOW GOOSE

SNOW GOOSE is a 1973 passenger vessel (inspected). The Coast Guard has recorded 81 inspections since 1985, most recently in March 2026, along with 90 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 18 March 2026.

Built
1973
Last inspected
18 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE5729
Flag
UNITED STATES
367370870
Maury page id
psix-47532

Inspections, by type

…with no type recorded7
Years with a record 41 calendar years (1985–2026)
The 81 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)62.8 ft × 18.0 ft × 7.9 ft
Registered tonnagegross 97 / net 75
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDONALD SMOTHERS · KETCHIKAN AK, UNITED STATES · built 1973
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBELLINGHAM, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 7 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
75 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE5729MMSI 367370870 · active · compulsorily equipped · granted 24 May 2018, expires 30 July 2028
WCY6018MMSI not assigned · expired · compulsorily equipped · granted 29 July 1998, cancelled 4 October 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 81

18 March 2026 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8318707
3 December 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8276568
5 March 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8084701
26 March 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7885474
6 December 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7834769
7 March 2023 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7643288
23 March 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7421793
18 March 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7420995
8 December 2021 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7360223
4 May 2021 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7189053
11 March 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6923370
3 December 2019 Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6862543
11 September 2019 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6809445
11 March 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6636202
28 February 2018 COI Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6362140
30 November 2017 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6313672
3 March 2017 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6099978
4 March 2016 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5822573
2 December 2015 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5769938
26 March 2014 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4831005
8 February 2012 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4241395
7 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4203950
22 March 2010 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3700523
22 February 2010 Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3682029
11 March 2009 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3427588
27 February 2008 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3154876
14 December 2007 Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3115571
6 March 2007 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2883081
13 March 2006 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2601679
3 November 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2527613
17 March 2005 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2313782
15 April 2004 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2047969
12 January 2004 Hull Examination · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1991025
24 October 2003 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1935523
30 July 2003 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1863894
14 March 2003 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1757259
27 March 2002 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1598048
27 November 2001 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1444656
20 March 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1427988
14 March 2000 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1386735
29 October 1999 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1384296
10 May 1999 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1440131
4 May 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1368728
3 December 1997 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1112593
27 October 1997 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1402537
21 May 1997 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1104151
7 May 1997 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1464033
3 March 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 229786
10 February 1997 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1104024
6 May 1996 Deficiency Check · Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1463965
9 August 1995 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 879489
31 May 1995 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1446203
1 May 1995 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1427051
30 June 1994 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1463095
16 May 1994 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1354704
2 May 1994 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 858763
30 April 1993 Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1419120
15 October 1992 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 959292
14 May 1992 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 955026
1 May 1992 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 956713
18 June 1991 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1197272
29 May 1991 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 904687
5 April 1991 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1215543
1 June 1990 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 899585
18 May 1990 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1228076
8 May 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 906048
8 May 1990 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1225262
13 April 1990 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1234658
2 April 1990 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 930842
1 March 1990 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1224614
12 May 1989 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1041481
28 April 1989 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1203025
21 April 1989 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1207961
17 June 1988 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1202933
15 April 1988 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 906047
15 April 1988 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 917863
15 April 1988 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1034446
12 June 1987 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1336680
20 August 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 987943
6 March 1986 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 988216
7 March 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 982214

Deficiency record · 90

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 March 2025 Resolved
46 CFR 183.10-10; [...] distribution panels shall be dripproof protected. Driproof protected means that equipment is so constructed and protected that its successful operation is not interfered with when subject to falling moisture, and uninsulated parts cannot be inadvertently touched or approached nearer than a safe distance. 120v distribution panel had open breaker slots. Vessel to install blanks or spare breakers to fully enclose inner wiring.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 2 April 2025
Resolution: Provided photos showing blanks in place.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 March 2025 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel stern light inop during inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2025
Resolved 2 April 2025
Resolution: Photo of functional stern light.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 5 March 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems. IBA off vessel for annual servicing. Vessel to send proof of installation and annual servicing when completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2025
Resolved 2 April 2025
Resolution: Liferaft servicing reports received.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 March 2025 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: [...] For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel attested to annual servicing, but no documentation from the servicing tech other than tags on the bottles. Vessel to supply documentation from servicing tech for components tested.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2025
Resolved 2 April 2025
Resolution: Received servicing report for fixed co2 system.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 5 March 2025 Resolved
47 CFR 80.903; Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessel radio safety certificate expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2025
Resolved 2 April 2025
Resolution: Received report for FCC certifications
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 March 2024 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMC. Marine inspector observed alcohol testing devices were not readily accessible due to being expired.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2024
Resolved 1 April 2024
Resolution: Recieved photo of new alcohol testing devices. Deficiency cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 March 2024 Resolved
At least one ring life buoy must be fitted with a lifeline. Marine inspector observed lifeline for starboard bridge wing life ring buoy to be heavily deteriorated by UV light and of insufficient length.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2024
Resolved 1 April 2024
Resolution: Recieved photo of new ring life buoy lifeline. Deficiency cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 March 2024 Resolved
Each life jacket carried on board the vessel must be marked in accordance with 46 CFR § 185.604. Marine inspector observed 01 child sized life without a mark of the vessel name.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2024
Resolved 1 April 2024
Resolution: Recieved photo of child life jacket with approved marking. Deficiency cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2023 Resolved
Provide evidence of pre-employment and enrolment in random chemical testing for all crewmembers
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 7 April 2023
Resolved 21 March 2023
Resolution: Received documentation of crew chemical testing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 March 2022 Resolved
Missing 01 child lifejacket
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 6 April 2022
Resolution: Replaced missing childs life jacket.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 March 2022 Resolved
Missing vessel name and hailing port on stern.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 6 April 2022
Resolution: Name and hailing port labeled on stern.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 December 2021 Resolved
Provide one line electrical diagram to MSC.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2022
Resolved 11 December 2023
Resolution: Owner in communication with MSC for final drawing approval.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2021 Resolved
Provide one line electrical diagram prior to completion on next dry dock exam, 31DEC21
Action required: 705 - Other - as specified
Due 31 December 2021
Resolved 14 December 2021
Resolution: Member provided unit with one line diagram.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 March 2020 Resolved
An alarm for a fixed gas fire extinguishing system must be clearly and conspicuously marked: "WHEN ALARM SOUNDS-VACATE AT ONCE. CARBON DIOXIDE BEING RELEASED". Noted that the alarm in the engineroom is not labeled. Required to label. 46CFR185.612(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2020
Resolved 17 March 2020
Resolution: Received pictures from operator of CO2 signage. All sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 March 2020 Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: Spaces storing carbon dioxide (1): "CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION". (2) Spaces protected by carbon dioxide: "CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING." Noted that the entrance to the engineroom that is protected by carbon dioxide and the space storing the cylinders is not marked. Required to mark. 46CFR185.612(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2020
Resolved 17 March 2020
Resolution: Received pictures from operator of CO2 signage. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 September 2019 Resolved
The owner/operator shall provide adequate number of watchmen patrol throughout the vessel during nighttime whether or not the Vessel is underway. 46CFR 185.410
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 6 November 2019
Resolution: Operator provided updated watch schedule for underway overnight operations
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 September 2019 Resolved
Vessel must have at least one fire axe located In or adjacent to primary operating station. 46 CFR 181.600
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 November 2019
Resolved 6 November 2019
Resolution: Vessel is under 65 feet and not required to comply with this regulation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 March 2019 Resolved
All 42 adult life jackets unserviceable. Provide 42 adult life jackets with proper markings. 46 CFR 180.71
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2019
Resolved 20 March 2019
Resolution: Replaced with new adult lifejackets.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 March 2019 Resolved
Radio station authorization expired. Provide valid station authorization certificate. 46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2019
Resolved 20 March 2019
Resolution: Had FCC the whole time.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 March 2019 Resolved
Multiple expired items in first aid kit. Provide approved kit or equivalent. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2019
Resolved 20 March 2019
Resolution: Replaced with new first aid kit.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 28 February 2018 Resolved
Provide evidence of pre-employment chemical testing for all crewmembers. 46 CFR 16.210
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 29 March 2018
Resolution: CAPT emailed picture of addressed descrepancy. All Sat.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 28 February 2018 Resolved
Provide comprehensive list of all crew members enrolled in consortium. 46 CFR 16.230(g)
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 29 March 2018
Resolution: CAPT emailed picture of addressed descrepancy. All Sat.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 28 February 2018 Resolved
Install exit signs on passenger accommodation deck near both exits in clearly legible letters at least 02 inches high that reads: "EMERGENCY EXIT, KEEP CLEAR". 46 CFR 185.606
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 5 March 2018
Resolution: CAPT emailed picture of addressed descrepancy. All Sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 February 2018 Resolved
Install unexpired battery in life ring light. 46 CFR 180.70(d)
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 5 March 2018
Resolution: CAPT emailed picture of addressed descrepancy. All Sat.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 28 February 2018 Resolved
Label life ring with vessel's name. 46 CFR 185.604(b)
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 5 March 2018
Resolution: CAPT emailed picture of addressed descrepancy. All Sat.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 26 March 2014 Resolved
Prove proper breaking strength on float-free link on buoyant apparatus or replace with one that is approved for 12-pers. Approval tag is missing from existing link.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 April 2014
Resolved 10 April 2014
Resolution: New approved link installed on buoyant apparatus.
Communications › Radio Communications › EPIRB
Issued 26 March 2014 Resolved
Replace battery in EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 April 2014
Resolved 7 April 2014
Resolution: New battery installed.
Lifesaving › Lifefloat › Float-free Link
Issued 24 March 2010 Resolved
Breaking strength for life float weak link cannot be determined. Provide new weak link with supporting documents for breaking strength IAW 46CFR180.137(b).
Action required: 705 - Other - as specified
Due 24 April 2010
Resolved 25 August 2010
Resolution: Weak link strength determined IAW NVIC 1-83.
Lifesaving › Hand Flares › Quantity
Issued 22 March 2010 Resolved
Vessel is required to carry 12 flares per 46CFR180.68(a). Vessel only has 11 flares. Vessel must provide one additional flare in accordance with cite.
Action required: 705 - Other - as specified
Due 24 April 2010
Resolved 31 March 2010
Resolution: Vessel purchased additional flares and now carries proper amount.
Lifesaving › Lifefloat › Retroreflective Material
Issued 22 March 2010 Resolved
Retroreflective tape on life float is worn beyond acceptable standards. Replace/Renew retroreflective tape on life float IAW 46CFR176.830.
Action required: 705 - Other - as specified
Due 24 April 2010
Resolved 31 March 2010
Resolution: Installed new retroreflective tape on life float.
Lifesaving › Lifebuoys › Stowage
Issued 22 March 2010 Resolved
Life ring light not properly attached IAW 46CFR180.70(d)(2),(3). Provide corrosion resistant clip and proper lanyard IAW CFR.
Action required: 705 - Other - as specified
Due 24 April 2010
Resolved 31 March 2010
Resolution: Properly attached life ring to light.
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 March 2010 Resolved
Drills not conducted. Perform satisfactory drills IAW 46CFR185.520, 185.524.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2010
Resolution: Conducted drills with master and crew. All sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 March 2009 Resolved
Clip/lanyard on life ring light was not properly attached around body of ring and routing of lanyard prevented ring from being readily available. O/O to reattach IAW 46 CFR 180.70(d)(2-3).
Action required: 705 - Other - as specified
Due 11 March 2009
Resolved 11 March 2009
Resolution: O/O attached light lanyard IAW 46 CFR 180.70(d)(2-3).
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 7 March 2008 Resolved
Replace STBD Lifering Lightline & retroreflective tape to the satisfaction of the Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2008
Resolved 17 March 2008
Resolution: Replaced STBD Lifering Lightline & retroreflective tape to the satisfaction of the Marine Inspector.
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 6 March 2007 Resolved
Swing compass and post updated deviation table.
Due 6 April 2007
Resolved 7 March 2008
Resolution: Compass swung and new deviation table posted.
Lifesaving › Lifejacket/PFD (General)
Issued 15 April 2004 Resolved
All adult life jackets need new reflective tape. LEGACY COMPONENT DESC: Retroreflective Material
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2004
Lifesaving › Lifebuoys
Issued 15 April 2004 Resolved
The ring buoy needs a new buoyant line. LEGACY COMPONENT DESC: Buoyant Lifeline
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2004
Lifesaving › Rigid Liferafts
Issued 15 April 2004 Resolved
The life float needs a buoyant line and weak link. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2004
Communications › Radio Communications
Issued 15 April 2004 Resolved
The hydrostatic release for the EBIRP needs to be renewed. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Resolved 4 May 2004
Personnel › Manning/Qualifications
Issued 15 April 2004 Resolved
50% of the crew needs to provide proof of first aid/CPR training. LEGACY COMPONENT DESC: CPR Certified Personnel
Action required: 705 - Other - as specified
Due 15 May 2004
Resolved 19 April 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 15 April 2004 Resolved
All expired materials in the first aid kit need to be updated. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Due 15 May 2004
Resolved 22 April 2004
Navigation › Piloting/Steering
Issued 15 April 2004 Resolved
Vessel needs a light list. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 15 May 2004
Resolved 19 April 2004
Construction/Loadline › Hull
Issued 24 October 2003 Resolved
Vessel required to undergo all required hull examinations prior to being placed back into service following the current due drydock date of 27NOV03, but no later than 15JAN04, to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 January 2004
Resolved 12 January 2004
Lifesaving
Issued 10 May 1999 Resolved
Properly mark stowage of lifejackets IAW 46 CFR 185.604(f) & 180.78(a)(5).
Condition: Unknown
Due 21 May 1999
Resolved 27 May 1999
Accommodation/Occupational Safety
Issued 27 October 1997 Resolved
REPLACE TWO BROKEN WINDOWS IN MAIN SALON.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Accommodation/Occupational Safety
Issued 27 October 1997 Resolved
MAKE RAILS AT BOW AREA SAFE BY INSTALLING COURSOS OR FENCING WITH SPACE NOTGREATER THAN 4 INCHES, OR MAKE THE AREA RESTRICTED FROM PASSENGER USE.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Lifesaving
Issued 7 May 1997 Resolved
INSTALL RETROREFLECTIVE MATERIAL ON LIFE FLOAT AND BUOYANT APPARATUS
Condition: Unknown
Due 21 May 1997
Resolved 22 May 1997
Lifesaving
Issued 7 May 1997 Resolved
REPLACE RING BUOY AND INSTALL RETROREFLECTIVE MATERIAL ALONG WITH DETACHABLE CLIP TO WATER LIGHT.
Condition: Unknown
Due 21 May 1997
Resolved 22 May 1997
Documentation
Issued 6 May 1996 Resolved
FCC CERT. OUT OF DATE. PROVIDE COPY OF NEW FCC LIC.
Condition: Unknown
Due 17 June 1996
Resolved 8 July 1996
Construction/Loadline
Issued 6 May 1996 Resolved
PROVIDE QUICK ACTING WTD MECHANISM FOR E/R ENTRANCE.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Lifesaving
Issued 6 May 1996 Resolved
PROVIDE LIFE-JACKET DONNING INSTRUCTION, TO BE POSTED IN LOUNGE.
Condition: Unknown
Due 17 June 1996
Resolved 8 July 1996
Engineering
Issued 6 May 1996 Resolved
INSTALL FLAME IMPIGMENT BOWL ON GENERATOR FUEL OIL FILTER.
Condition: Unknown
Due 17 June 1996
Resolved 8 July 1996
Construction/Loadline
Issued 31 May 1995 Resolved
CONTACT MSO PUGET SOUND WHEN HEATING BOILER IS REMOVED FROM ENGINE COMPARTMENT. WEIGH BOILER AND PROVIDE WEIGHT TO THIS OFFICE SO EFFECT OF REMOVAL OF SUCH WEIGHT ON VESSEL'S STABILITY CAN BE DETERMINED.
Condition: Unknown
Due 31 May 1995
Resolved 31 May 1995
Electrical
Issued 1 May 1995 Resolved
REPAIR FREQUENCY GAGE FOR DIESEL GENERATOR
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Electrical
Issued 1 May 1995 Resolved
REPAIR OR REMOVE LIGHT FIXTURE AFT OF PILOT HOUSE
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Accommodation/Occupational Safety
Issued 1 May 1995 Resolved
ESTABLISH AND PROVIDE PROOF OF PARTICIPATION IN A DRUG TESTING PROGRAM IN ACCORDANCE WITH 46CFR16.
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Engineering
Issued 1 May 1995 Resolved
AUX HEATING BOILER TO BE TESTED AND INSPECTED IAW 46 CFR 182.10-5C AND 176.25-30C TO INCLUDE BUT NOT BE LIMITED TO HYDRO, FIRESIDE, WATERSIDE EXAMAND FLAME MANAGEMENT TESTS WITNESSED BY USCG MARINE INSPECTOR PRIOR TO PLACING BOILER IN OPERATION WITH PASSENGERS ABOARD.
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Documentation
Issued 30 April 1993 Resolved
PROVIDE ON BOARD VALID CERT. OF DOCUMENTATION.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Documentation
Issued 30 April 1993 Resolved
PROVIDE PROOF OF ENROLLMENT IN RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Electrical
Issued 30 April 1993 Resolved
REPLACE/REPAIR COVER OVER GENERATOR BRUSH HOUSING RECTIFIER.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Lifesaving
Issued 1 May 1992 Resolved
STENCIL VESSEL NAME ON LIFE FLOAT AND BUOYANT APPARATUS.
Condition: Unknown
Due 1 May 1992
Resolved 1 May 1992
Construction/Loadline
Issued 1 May 1992 Resolved
RENEW RUBBER GASKET AND REMOVE PAINT FROM KNIFE EDGE OF ENGINE ROOM WATERTIGHT DOOR. PERFORM CHALK TEST TO PROVE INTEGRITY.
Condition: Unknown
Due 1 May 1992
Resolved 1 May 1992
Navigation
Issued 1 May 1992 Resolved
MAKE MASTHEAD LIGHT FUNCTIONAL AND MAKE VERTICAL SEPARATION BETWEEN PORT AND STBD RUNNING LIGHTS AND MASTHEAD LIGHT ONE METER.
Condition: Unknown
Due 1 May 1992
Resolved 1 May 1992
Documentation
Issued 29 May 1991 Resolved
PLACE COI AND DOCUMENTS UNDER PLEXIGLASS._x001C_
Condition: Unknown
Due 29 May 1991
Resolved 29 May 1991
Construction/Loadline
Issued 29 May 1991 Resolved
CLEAR DRAIN LINES FOR MAIN DECK HATCH TO ENGINE ROOM.
Condition: Unknown
Due 29 May 1991
Resolved 29 May 1991
Fire Fighting
Issued 29 May 1991 Resolved
REPLACE GASKET ON MANIFOLD AT FIRE PUMP.
Condition: Unknown
Due 29 May 1991
Resolved 29 May 1991
Navigation
Issued 29 May 1991 Resolved
PROVIDE OPERABLE EPIRB.
Condition: Unknown
Due 29 May 1991
Resolved 29 May 1991
Navigation
Issued 29 May 1991 Resolved
RENEW AND REROUTE GROUNDING STRAPS ON STEERING RAMS.
Condition: Unknown
Due 29 May 1991
Resolved 29 May 1991
Fire Fighting
Issued 29 May 1991 Resolved
INSTALL PRESSURE GAUGE ON DISCHARGE SIDE OF FIRE PUMP.
Condition: Unknown
Due 29 May 1991
Resolved 29 May 1991
Construction/Loadline
Issued 29 May 1991 Resolved
PROVE WATERTIGHTNESS OF MAIN DECK HATCH TO ENGINE ROOM.
Condition: Unknown
Due 29 May 1991
Resolved 29 May 1991
Fire Fighting
Issued 5 April 1991 Resolved
TEST INSTALLED CO2 SYSTEM IN PRESENCE OF USCG.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Accommodation/Occupational Safety
Issued 5 April 1991 Resolved
SERVICE FURNACE TO ELIMINATE FUMES IN ENGINE ROOM.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Engineering
Issued 5 April 1991 Resolved
CLEAN ENGINE ROOM BILGES.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Engineering
Issued 5 April 1991 Resolved
PROVE SATISFACTORY OPERATION OF ENGINES, STEERING, FIRE PUMP, AND EMERGENCYLIGHTING.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Engineering
Issued 5 April 1991 Resolved
PLUG AUX FUEL FILTERS WHERE PETCOCKS ARE PRESENT.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Electrical
Issued 5 April 1991 Resolved
LINE BATTERY BOX.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Documentation
Issued 5 April 1991 Resolved
PROVIDE FCC RT CERTIFICATE.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Lifesaving
Issued 21 April 1989 Resolved
POST LIFEJACKET DONNING INSTRUCTIONS PRIOR TO CARRIAGE OF PASSENGERS TO THESATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 21 April 1989
Resolved 21 April 1989
Lifesaving
Issued 21 April 1989 Resolved
FRESHEN LIFEFLOAT COVERING AND RESTENCIL WITH CAPACITY AND VESSEL NAME PRIOR TO 02 MAY 1989 TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 21 April 1989
Resolved 21 April 1989
Lifesaving
Issued 21 April 1989 Resolved
RENEW BATTERIES IN FLOAT LIGHTS PRIOR TO CARRIAGE OF PASSENGERS TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 21 April 1989
Resolved 21 April 1989
Fire Fighting
Issued 21 April 1989 Resolved
SERVICE ALL FIRE EXTINGUISHERS ON BOARD PRIOR TO THE CARRAIGE OF PASSENGERSTO THE SATRISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 21 April 1989
Resolved 21 April 1989
Electrical
Issued 21 April 1989 Resolved
BATTERY FITTINGS TO BE BROUGHT INTO COMPLIANCE WITH 46 CFR PRIOR TO 02 MAY 1989 TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 21 April 1989
Resolved 21 April 1989
Electrical
Issued 21 April 1989 Resolved
BLOCK BATTERIES PRIOR TO 02 MAY 1989 TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 21 April 1989
Resolved 21 April 1989
Construction/Loadline
Issued 15 April 1988 Resolved
PROVIDE INSIDE HINGED DEAD COVERS IAW 46 CFR 171.119. DEAD COVERS OF THE STORED TYPE MUST MEET THE REQUIREMENTS OF 46 CFR 171.117, PARTICULARLY IN THAT IT SHALL NOT NECESSARY TO RELEASE ANY SPECIAL NUTS IN ORDER TO SECURE THE DEAD COVER. ABOVE SHALL BE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Electrical
Issued 6 March 1986 Resolved
REPLACE NYLON TIE WRAPS ON ALL OVERHEAD AND VERTICAL ELECTRIC WIRE RUNS, MOUNT ACCORDING TO APPROPRIATE REGS.
Condition: Unknown
Due 6 March 1986
Resolved 6 March 1986
Electrical
Issued 6 March 1986 Resolved
INSTALL COVERS ON BATTERIES FOR AUX. MACHINERY.
Condition: Unknown
Due 6 March 1986
Resolved 6 March 1986
Documentation
Issued 6 March 1986 Resolved
RENEW CERTIFICATE OF DOCUMENTATION WITH NEW OWNERS NAME, ADDRESS AND UPDATESTAMP.
Condition: Unknown
Due 6 March 1986
Resolved 6 March 1986
Navigation
Issued 6 March 1986 Resolved
REPAIR PORT RUNNING LIGHT WIRING BY PROPER REPAIR METHODS OR REPLACE AND MOUNT IN PROPER MANNER.
Condition: Unknown
Due 6 March 1986
Resolved 6 March 1986
Lifesaving
Issued 6 March 1986 Resolved
REPLACE LIFELINE ON 12 MAN LIFEFLOAT.
Condition: Unknown
Due 6 March 1986
Resolved 6 March 1986
Lifesaving
Issued 6 March 1986 Resolved
REPAIR OF REPLACE 1 CHILDS LIFEJACKETS.
Condition: Unknown
Due 6 March 1986
Resolved 6 March 1986

Ownership record