FAST SERVICE is a 1998 passenger vessel (inspected). The Coast Guard has recorded 31 inspections since 1998, most recently in May 2016, along with 42 deficiencies.

Records from 1998 to 2016. Most recent: inspection, 13 May 2016.

Built
1998
Last inspected
13 May 2016
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8968698 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDE5275
475354
Flag
UNITED STATES
366333000, 367364310 (licence lapsed)
Maury page id
psix-475354

Inspections, by type

…with no type recorded6
Years with a record 17 calendar years (1998–2016)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)150.3 ft × 32.0 ft × 13.0 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)150.3 ft × 32.0 ft × 13.0 ft
ITC tonnagegross 382 / net 114
BuilderBREAUX BROTHERS ENT INC · LOREAUVILLE LA, UNITED STATES · built 1998
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 24 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it382 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
114 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE5275MMSI 367364310 · expired · compulsorily equipped · granted 21 June 2008, cancelled 25 August 2018
WCY4417MMSI 366333000 · expired · compulsorily equipped · granted 21 July 1998, cancelled 9 August 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 31

13 May 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5876215
1 October 2015 Deficiency Check
Physical examination · Activities Europe · Activity 5733257
29 August 2014 Annual Inspection · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 4952288
20 January 2012 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4228508
27 September 2010 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3856593
18 March 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3419695
16 May 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3208108
3 April 2008 Deficiency Check · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3176950
18 June 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2966015
17 June 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2965978
4 May 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2922439
4 May 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2922467
12 April 2007 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2906737
30 January 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2864075
28 January 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2864057
27 March 2006 Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2610352
27 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2502074
8 November 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2237236
8 June 2004 MTSA/ISPS Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2091999
25 March 2004 Internal Structural Exam · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2034155
25 August 2003 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1886865
12 June 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1815537
14 May 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1617053
15 April 2002 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1606672
28 June 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464397
25 July 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395508
28 June 2000 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435072
20 July 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447984
24 September 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 799766
1 August 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 794973
9 July 1998 Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423034

Deficiency record · 42

Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 March 2009 Resolved
Install bolts on exhaust trunk for port MDE.
Due 18 April 2009
Resolved 18 March 2009
Engineering › Freshwater Generation System › Piping
Issued 18 March 2009 Resolved
Secure piping in engine room on stbd side.
Condition: Improper/Lack of Maintenance
Due 18 April 2009
Resolved 18 March 2009
Stability › Watertight Integrity › General
Issued 18 March 2009 Resolved
Correct watertight integrity issues (watertight door closures) as noted by ABS during Load Line survey.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2009
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 18 March 2009 Resolved
Fix distrobution panel for range disconnect (to allow opening).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 March 2009 Resolved
Renew first aid kit on bridge.
Due 18 April 2009
Resolved 18 March 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 April 2008 Resolved
Repair bilge alarm system; ensure both audible and visual. The crew members removed the fuse so that it would not go off everytime someone opened a watertight door; bilge alarm and watertight door alarm are connected.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2008
Communications › Radio Communications › EPIRB
Issued 3 April 2008 Resolved
Replace hydrostatic release for EPRIB; expired in 2007.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2008
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 3 April 2008 Resolved
Repair stbd remote emergency fuel shut off valve.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2008
Communications › Audible Communications › Horn/Whistle
Issued 3 April 2008 Resolved
Show proper operation of he ships horn.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2008
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 3 April 2008 Resolved
Provide all three (3) air receivers for visual inspection
Action required: 705 - Other - as specified
Resolved 7 May 2008
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 3 April 2008 Resolved
Paint draft marks contrasting color to the hull.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2008
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 3 April 2008 Resolved
Repair/Replace rescue platform so that is is functional in the recovery of a man overboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 April 2007 Resolved
Dead ended wiring was found forward of the rudder compartment at the hydraulic pump.
Action required: 705 - Other - as specified
Due 19 April 2007
Resolved 18 April 2007
Electrical › Electric Generation Source (service) › Generator
Issued 12 April 2007 Resolved
The starboard generator was missing exhaust lagging and had a water leak.
Due 19 April 2007
Resolved 18 April 2007
Fire Fighting › Fire Pumps › Gland Sealing
Issued 12 April 2007 Resolved
The fire pump had worn seals and was not operable due to poor suction.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 April 2007 Resolved
One exhaust fan in the engine room was missing a rotating machinery guard.
Action required: 705 - Other - as specified
Due 19 April 2007
Resolved 18 April 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 12 June 2003 Resolved
PROVIDE CURRENT COPY OF CG LIGHT LIST PRIOR TO SAILING.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2003
Resolved 13 June 2003
Resolution: PROVIDED CURRENT COPY OF CG LIGHT LIST.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 12 June 2003 Resolved
PROVIDE AND INSTALL BLANK IN GENERATOR ROOM POWER PANEL.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 July 2003
Resolved 13 June 2003
Resolution: INSTALLED BLANK IN GENERATOR ROOM POWER PANEL.
Electrical › Electric Supply System (service) › Battery Charger
Issued 12 June 2003 Resolved
REPAIR OR RENEW TWO BATTERY CHARGERS IN GENERATOR ROOM.
Action required: 705 - Other - as specified
Due 12 July 2003
Resolved 13 June 2003
Resolution: INSTALLED TWO NEW BATTERY CHARGERS IN GENERATOR ROOM.
Construction/Loadline › Hull › Weld
Issued 12 June 2003 Resolved
REPAIR CRACKS IN BOTH PORT AND STARBOARD MAIN DECK AROUND MID-BODY PRIOR TO SAILING.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2003
Resolved 13 June 2003
Resolution: WELDED CRACKS IN MAIN DECK.
Construction/Loadline › Structures › Door
Issued 12 June 2003 Resolved
ADJUST WATER-TIGHT DOOR AS DISCUSSED PRIOR TO SAILING.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2003
Resolved 13 June 2003
Resolution: ADJUSTED WATER-TIGHT DOORS AS DISCUSSED.
Engineering › Fuel Oil Service System › Hose
Issued 12 June 2003 Resolved
RENEW ONE FUEL OIL HOSE PRIOR TO SAILING.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2003
Resolved 13 June 2003
Resolution: REPLACED/RENEWED FUEL OIL HOSE.
Lifesaving › Buoyant Apparatus
Issued 12 June 2003 Resolved
REPAIR ONE LIFE FLOAT PRIOR TO SAILING. LEGACY COMPONENT DESC: Life Float
Action required: 17 - Rectify deficiencies prior to departure
Due 12 July 2003
Resolved 13 June 2003
Resolution: REPAIRED ONE LIFE FLOAT.
Operations/Management › Drills/Instruction
Issued 14 May 2002 Resolved
Post Station Bill. LEGACY COMPONENT DESC: Station Bill
Action required: 705 - Other - as specified
Due 14 June 2002
Resolved 12 June 2003
Fire Fighting › Ventilation Systems
Issued 14 May 2002 Resolved
Repair vent closures to engine room insuring proper operation. LEGACY COMPONENT DESC: Duct Hatches
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2002
Resolved 12 June 2003
Stability › Watertight Integrity
Issued 14 May 2002 Resolved
Repair/replace two broken ball check valves on deck. LEGACY COMPONENT DESC: Gooseneck Vents
Action required: 17 - Rectify deficiencies prior to departure
Due 14 June 2002
Resolved 12 June 2003
Pollution Prevention/Response › Prevention Equipment
Issued 14 May 2002 Resolved
Properly secure sewage overboard discharge valve. LEGACY COMPONENT DESC: Sewage System Valve
Action required: 705 - Other - as specified
Due 14 June 2002
Resolved 12 June 2003
Engineering › Fuel Oil Service System
Issued 14 May 2002 Resolved
Replace petcocks on fuel filters with type that enables the use of plugs. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 14 June 2002
Resolved 12 June 2003
Construction/Loadline › Hull › Hull Plating
Issued 15 April 2002 Resolved
C/R IWO STBD MIDSHIPS DECK BY BULWORKS (1) 18 X 18 PLATE.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2002
Resolved 15 April 2002
Fire Fighting
Issued 24 September 1998 Resolved
MAKE CHANGES TO THE FIRE DETECTION SYSTEM DEEMING ALL COMPONENTS FROM A SINGLE COAST GUARD APPROVED TYPE AS REQUIRED BY G-MSC-2 LTR. SER. #E2- 9803177 DATED 16SEP98.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Lifesaving
Issued 9 July 1998 Resolved
PROVIDE ON BOARD THE HARNESS FOR THE RESCUE DAVIT.
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Accommodation/Occupational Safety
Issued 9 July 1998 Resolved
REPAIR THE PORT WALK-IN REEFER.
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Construction/Loadline
Issued 9 July 1998 Resolved
MAKE OPERABLE THE BILGE EDUCTION SYSTEM AND DEMONSTRATE TO THE ATTENDING U.S.C.G. MARINE INSPECTOR PRIOR TO SAILING.
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Electrical
Issued 9 July 1998 Resolved
NSTALL A BREAKER LEGEND CARD FOR THE PANEL BOX LOCATED IN THE ENGINE ROOM FWD. BULKHEAD PORT SIDE.
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Documentation
Issued 9 July 1998 Resolved
PROVIDE ON BOARD A VALID F.C.C. RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Documentation
Issued 9 July 1998 Resolved
PROVIDE ON BOARD A VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY AS DIRECTED BY [name withheld] DATED 03JUN98 SER. #M-80162 PRIOR TO GOING ON AN INTERNATIONAL VOYAGE.
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Navigation
Issued 9 July 1998 Resolved
REPAIR THE 110 VOLT POWER SUPPLY TO THE RADIOS.
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Documentation
Issued 9 July 1998 Resolved
PROVIDE ON BOARD A CURRENT COPY OF NAVRULS.
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Navigation
Issued 9 July 1998 Resolved
MAKE NECESSARY REPAIRS TO THE BOW THRUSTER AND DEMONSTRATE TO THE ATTENDINGU.S.C.G. MARINE INSPECTOR.
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Navigation
Issued 9 July 1998 Resolved
PROVIDE ON BOARD A VALID COMPASS DEVIATION CARD.
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Fire Fighting
Issued 9 July 1998 Resolved
CONDUCT ABONDON SHIP, MAN OVERBOARD, AND FIRE FIGHTING DRILLS AS REQUIRED BY 46 CFR 185.520 AND 185.524 PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 7 August 1998
Resolved 7 August 1998
Navigation
Issued 9 July 1998 Resolved
REPAIR THE STEERING PUMP FAILURE ALARM.