Records from 2016 to 2026. Most recent: inspection, 22 April 2026.
Inspection history · 21
22 April 2026
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8354237
12 November 2025
Administrative Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8267767
2 July 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8170851
6 August 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7975893
30 July 2024
Type not recorded
No type recorded · Maritime Safety & Security Team Seattle (91101) · Activity 7971739
22 May 2024
Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7915917
1 August 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7758321
25 July 2022
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7513204
23 May 2022
Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7465871
9 September 2021
Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7342160
21 May 2021
Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7202827
7 May 2021
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7205711
18 August 2020
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7145065
5 August 2020
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7023820
3 June 2020
Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6967379
31 May 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6683141
2 May 2018
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6403586
22 May 2017
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6235573
2 February 2017
Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6081760
23 March 2016
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5854408
22 March 2016
Drydock Exam · COI Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5892753
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 April 2026
Resolved
Tested fire control space alarms in alignment w/ fire control panel (red panel in ladderwell in wheel house) - audible alarms worked but would not indicate spaces correctly on panel at operating station (panel stated "battery" rather than the space number, as required). Red battery light was consistent w/ flashing AC/DC green light on fire control panel, indicating an error.
Action required: 705 - Other - as specified
Due 28 June 2026
Resolved 9 June 2026
Resolution: Cleared
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 April 2026
Resolved
Flares expired.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2026
Resolution: Corrected while MI onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 April 2026
Resolved
Alcohol test strips expired.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2026
Resolution: Corrected while MI onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 22 May 2024
Resolved
Provide a plan to restore structure of transom gunwale to the OCMI prior to next drydock for credit.
Action required: 705 - Other - as specified
Resolved 6 August 2024
Resolution: gunwale reinforced
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 July 2022
Resolved
Vessel required to carry 6 day and 6 night distress flares. Vessel ohly has 3 day and 4 night. Restricted to Kachemak Bay until required distress flares are onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 26 July 2022
Resolution: required flares onboard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2022
Resolved
Provide lagging on exposed exhaust piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 24 August 2022
Resolution: Installed
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 July 2022
Resolved
Update first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 24 August 2022
Resolution: Updated
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 25 July 2022
Resolved
Passenger vessels are required FCC Safety Radiotelephony Cert.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 24 August 2022
Resolution: Onboard
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 25 July 2022
Resolved
Renew missing pin on EPIRB
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 26 July 2022
Resolution: Renewed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 May 2021
Resolved
Remove inproper installation of heater wiring in engine room. Not use correct wiring (marine).
Action required: 10 - Deficiency Rectified
Resolved 27 May 2021
Resolution: corrected
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 27 May 2021
Resolved
Vessel is not logging drills, EPIRB, tests, trips, etc.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2021
Resolved 22 June 2021
Resolution: corrected
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 27 May 2021
Resolved
Vessel does not have a garbage management plan. Issued in error.
Action required: 10 - Deficiency Rectified
Resolved 27 May 2021
Resolution: found on board
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 May 2021
Resolved
Vessel does not have current charts onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2021
Resolved 22 June 2021
Resolution: corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 May 2021
Resolved
Properly install outlet covers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2021
Resolved 22 June 2021
Resolution: repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 May 2021
Resolved
Make all bilge suctions available for operational testing.
Action required: 10 - Deficiency Rectified
Resolved 28 May 2021
Resolution: witnessed satisfactory operation
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 May 2021
Resolved
Replace the forward starboard bow draft marks that were removed as a result of steel repair.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 January 2022
Resolved 8 October 2021
Resolution: Stenciled and welded.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 August 2020
Resolved
Vessel to provide valid lifesaving appliance carrying capacity with proper servicing with proper servicing for the amounts shown on the COI. *Restricted to carry no more than 50 passengers.*
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 August 2020
Resolved 22 June 2021
Resolution: Renewed
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 August 2020
Resolved
Vessel to have distress signals stored in an approved container and marked accordingly.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 22 June 2021
Resolution: corrected
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 August 2020
Resolved
Vessel to replace the expired medicines found onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 22 June 2021
Resolution: replaced
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 18 August 2020
Resolved
Vessel Masters to show proof of holding a valid FCC radio operator permit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 22 June 2021
Resolution: corrected
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 31 May 2019
Resolved
Replace wasted piping on fuel tank vents - starboard 'saddle' tank & port foward tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 25 June 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 May 2019
Resolved
Provide a pressure gauge for fire pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 4 August 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 31 May 2019
Resolved
Provide a current FCC ship station license
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2019
Resolved 4 June 2020
Resolution: Vessel has a valid FCC ship station license.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 31 May 2019
Resolved
Provide an FCC safety radiotelephony certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2019
Resolved 4 June 2020
Resolution: Vessel has a valid FCC safety radiotelephony certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 May 2019
Resolved
Clean up connections on battery for VHF radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2019
Resolved 25 June 2019
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 31 May 2019
Resolved
Replace EPIRB battery & hydrostatic release.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 May 2019
Resolved
provide 6 red & 6 orange smoke flares or 12 red flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 31 May 2019
Resolved
Provide contents for first aid kit: Aspirin, Ammonia Inhalants, Iodine Applicators.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2019
Resolved 25 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 May 2019
Resolved
Replace retroreflective tape on port life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2019
Resolved 22 June 2021
Resolution: corrected
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 May 2019
Resolved
Replace retroreflective tape on 15 adult & 12 child lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2019
Resolved 4 August 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 May 2019
Resolved
Vessel limited to 42 adult passengers until new lifejackets are onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 31 May 2019
Resolved
Replace gasket on watertight doors - port & starboard to house & port to wheelhouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 25 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 May 2019
Resolved
Replace port waterlight bracket next to lifering.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 25 June 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 May 2019
Resolved
Provide a spanner wrench for stbd fire hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2019
Resolved 22 June 2021
Resolution: corrected
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 31 May 2019
Resolved
Provide new labels for fuel vents - port fwd & stbd 'saddle'
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 4 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 May 2019
Resolved
Replace stern light with proper bulb.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2019
Resolved 25 June 2019
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 22 May 2017
Resolved
Vessel retroreflective material is faded and required to be replaced.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 30 May 2019
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 May 2017
Resolved
Vessel missing Certificate of Documentation, and only had previous COD's.Vessel must provide proof of COD and place original on board the vessel.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 23 May 2017
Resolution: Vessel owner had original COD on board.
Communications › Radio Communications › EPIRB
Issued 22 May 2017
Resolved
Vessel replaced EPIRB Battery and didn't mark the dates as required. Corrected on the spot.
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 22 May 2017
Resolution: Master provided proof of purchase and allowed to correct on the spot.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 22 May 2017
Resolved
Master could not provide proof of current CPR certification.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 23 May 2017
Resolution: Vessel master and deckhand had CPR and First Aid cert.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 May 2017
Resolved
Vessel's anchor light was a househould bulb. Vessel must replace to certified nav light.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 30 May 2019
Electrical › Lighting (service) › Lighting Fixture
Issued 22 May 2017
Resolved
Vessel has stbd deck light unfixed to vessel and sitting atop house structure and endangering passengers as they walk by. Vessel must remove and replace in kind.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 30 May 2019
Lifesaving › Lifebuoys › Serviceable
Issued 22 May 2017
Resolved
Vessel's port and stbd liferings were not serviceable and must be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2017
Resolution: Vessel owner replaced both liferings with new and approved ones.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 May 2017
Resolved
Vessel's first aid kit had expired medication.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2019
Engineering › Bilge Water Management System › Strainer
Issued 22 March 2016
Resolved
Make repairs to cargo bilge strainer and piping to coupling. Located just fwd of Engine room.
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 22 May 2017
Resolution: Verified at Annual Inspection. All sat.
Engineering › Bilge Water Management System › Valve
Issued 22 March 2016
Resolved
Make repairs to bilge valve for crew quarters space. Vlv located under hydraulic tank in E/R.
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 22 May 2017
Resolution: Verified at Annual Inspection. All sat.