Records from 1985 to 2026. Most recent: inspection, 22 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 68
22 April 2026
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8354237
12 November 2025
Administrative Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8267767
2 July 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8170851
6 August 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7975893
30 July 2024
Type not recorded
No type recorded · Maritime Safety & Security Team Seattle (91101) · Activity 7971739
22 May 2024
Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7915917
1 August 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7758321
25 July 2022
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7513204
23 May 2022
Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7465871
9 September 2021
Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7342160
21 May 2021
Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7202827
7 May 2021
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7205711
18 August 2020
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7145065
5 August 2020
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7023820
3 June 2020
Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6967379
31 May 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6683141
2 May 2018
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6403586
22 May 2017
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6235573
2 February 2017
Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6081760
23 March 2016
Liferaft Servicing
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5854408
22 March 2016
Drydock Exam · COI Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5892753
21 July 2015
Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5191349
27 June 2014
Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 4901902
22 June 2012
Annual Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4352287
3 February 2012
Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 4238080
7 May 2009
Hull Examination · DAPI Audit · Annual Inspection · Spot Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3469547
14 August 2008
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3298730
30 May 2007
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 3014859
8 March 2007
Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2884450
22 April 2006
COI Inspection · Hull Examination
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2631251
24 May 2005
Re-Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2393667
4 May 2004
Re-Inspection · Hull Examination
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2062141
6 May 2003
Re-Inspection
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1805679
30 May 2002
Re-Inspection · Hull Examination
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1637682
26 April 2001
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1420508
6 July 2000
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 822701
12 May 2000
Re-Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1361476
22 April 1999
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1388789
1 June 1998
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 792971
27 April 1998
COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 790074
10 December 1997
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 51292
7 April 1997
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1093875
19 May 1996
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1081506
17 April 1996
Re-Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1085773
19 April 1995
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 872378
27 May 1994
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 97094
29 April 1994
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1358392
25 April 1994
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1471313
5 May 1993
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1385065
23 September 1992
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 643275
18 September 1992
Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 109159
30 April 1992
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 956790
17 April 1992
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1259391
15 April 1992
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 957887
18 July 1991
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1243628
18 May 1991
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 932568
13 November 1990
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 932565
18 April 1990
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1224705
21 February 1990
Hull Examination · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1214750
27 May 1989
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1196252
22 May 1989
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1034700
22 May 1989
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1347281
7 June 1988
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 890394
30 April 1987
Hull Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1018170
7 October 1986
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1315605
6 June 1986
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 994043
13 January 1986
Credit Drydock
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1299811
8 April 1985
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 982591
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 April 2026
Resolved
Tested fire control space alarms in alignment w/ fire control panel (red panel in ladderwell in wheel house) - audible alarms worked but would not indicate spaces correctly on panel at operating station (panel stated "battery" rather than the space number, as required). Red battery light was consistent w/ flashing AC/DC green light on fire control panel, indicating an error.
Action required: 705 - Other - as specified
Due 28 June 2026
Resolved 9 June 2026
Resolution: Cleared
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 28 April 2026
Resolved
Flares expired.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2026
Resolution: Corrected while MI onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 April 2026
Resolved
Alcohol test strips expired.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2026
Resolution: Corrected while MI onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 22 May 2024
Resolved
Provide a plan to restore structure of transom gunwale to the OCMI prior to next drydock for credit.
Action required: 705 - Other - as specified
Resolved 6 August 2024
Resolution: gunwale reinforced
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 July 2022
Resolved
Vessel required to carry 6 day and 6 night distress flares. Vessel ohly has 3 day and 4 night. Restricted to Kachemak Bay until required distress flares are onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 26 July 2022
Resolution: required flares onboard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 July 2022
Resolved
Provide lagging on exposed exhaust piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 24 August 2022
Resolution: Installed
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 July 2022
Resolved
Update first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 24 August 2022
Resolution: Updated
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 25 July 2022
Resolved
Passenger vessels are required FCC Safety Radiotelephony Cert.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 24 August 2022
Resolution: Onboard
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 25 July 2022
Resolved
Renew missing pin on EPIRB
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 August 2022
Resolved 26 July 2022
Resolution: Renewed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 May 2021
Resolved
Remove inproper installation of heater wiring in engine room. Not use correct wiring (marine).
Action required: 10 - Deficiency Rectified
Resolved 27 May 2021
Resolution: corrected
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 27 May 2021
Resolved
Vessel is not logging drills, EPIRB, tests, trips, etc.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2021
Resolved 22 June 2021
Resolution: corrected
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 27 May 2021
Resolved
Vessel does not have a garbage management plan. Issued in error.
Action required: 10 - Deficiency Rectified
Resolved 27 May 2021
Resolution: found on board
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 May 2021
Resolved
Vessel does not have current charts onboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2021
Resolved 22 June 2021
Resolution: corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 May 2021
Resolved
Properly install outlet covers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2021
Resolved 22 June 2021
Resolution: repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 May 2021
Resolved
Make all bilge suctions available for operational testing.
Action required: 10 - Deficiency Rectified
Resolved 28 May 2021
Resolution: witnessed satisfactory operation
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 May 2021
Resolved
Replace the forward starboard bow draft marks that were removed as a result of steel repair.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 January 2022
Resolved 8 October 2021
Resolution: Stenciled and welded.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 18 August 2020
Resolved
Vessel to provide valid lifesaving appliance carrying capacity with proper servicing with proper servicing for the amounts shown on the COI. *Restricted to carry no more than 50 passengers.*
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 August 2020
Resolved 22 June 2021
Resolution: Renewed
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 August 2020
Resolved
Vessel to have distress signals stored in an approved container and marked accordingly.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 22 June 2021
Resolution: corrected
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 August 2020
Resolved
Vessel to replace the expired medicines found onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 22 June 2021
Resolution: replaced
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 18 August 2020
Resolved
Vessel Masters to show proof of holding a valid FCC radio operator permit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2020
Resolved 22 June 2021
Resolution: corrected
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 31 May 2019
Resolved
Replace wasted piping on fuel tank vents - starboard 'saddle' tank & port foward tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 25 June 2019
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 May 2019
Resolved
Provide a pressure gauge for fire pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 4 August 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 31 May 2019
Resolved
Provide a current FCC ship station license
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2019
Resolved 4 June 2020
Resolution: Vessel has a valid FCC ship station license.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 31 May 2019
Resolved
Provide an FCC safety radiotelephony certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2019
Resolved 4 June 2020
Resolution: Vessel has a valid FCC safety radiotelephony certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 May 2019
Resolved
Clean up connections on battery for VHF radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2019
Resolved 25 June 2019
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 31 May 2019
Resolved
Replace EPIRB battery & hydrostatic release.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 May 2019
Resolved
provide 6 red & 6 orange smoke flares or 12 red flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 31 May 2019
Resolved
Provide contents for first aid kit: Aspirin, Ammonia Inhalants, Iodine Applicators.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2019
Resolved 25 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 May 2019
Resolved
Replace retroreflective tape on port life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2019
Resolved 22 June 2021
Resolution: corrected
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 May 2019
Resolved
Replace retroreflective tape on 15 adult & 12 child lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2019
Resolved 4 August 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 May 2019
Resolved
Vessel limited to 42 adult passengers until new lifejackets are onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 31 May 2019
Resolved
Replace gasket on watertight doors - port & starboard to house & port to wheelhouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 25 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 May 2019
Resolved
Replace port waterlight bracket next to lifering.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 25 June 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 May 2019
Resolved
Provide a spanner wrench for stbd fire hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2019
Resolved 22 June 2021
Resolution: corrected
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 31 May 2019
Resolved
Provide new labels for fuel vents - port fwd & stbd 'saddle'
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2019
Resolved 4 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 May 2019
Resolved
Replace stern light with proper bulb.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2019
Resolved 25 June 2019
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 22 May 2017
Resolved
Vessel retroreflective material is faded and required to be replaced.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 30 May 2019
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 May 2017
Resolved
Vessel missing Certificate of Documentation, and only had previous COD's.Vessel must provide proof of COD and place original on board the vessel.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 23 May 2017
Resolution: Vessel owner had original COD on board.
Communications › Radio Communications › EPIRB
Issued 22 May 2017
Resolved
Vessel replaced EPIRB Battery and didn't mark the dates as required. Corrected on the spot.
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 22 May 2017
Resolution: Master provided proof of purchase and allowed to correct on the spot.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 22 May 2017
Resolved
Master could not provide proof of current CPR certification.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 23 May 2017
Resolution: Vessel master and deckhand had CPR and First Aid cert.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 May 2017
Resolved
Vessel's anchor light was a househould bulb. Vessel must replace to certified nav light.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 30 May 2019
Electrical › Lighting (service) › Lighting Fixture
Issued 22 May 2017
Resolved
Vessel has stbd deck light unfixed to vessel and sitting atop house structure and endangering passengers as they walk by. Vessel must remove and replace in kind.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 30 May 2019
Lifesaving › Lifebuoys › Serviceable
Issued 22 May 2017
Resolved
Vessel's port and stbd liferings were not serviceable and must be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2017
Resolution: Vessel owner replaced both liferings with new and approved ones.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 May 2017
Resolved
Vessel's first aid kit had expired medication.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2019
Engineering › Bilge Water Management System › Strainer
Issued 22 March 2016
Resolved
Make repairs to cargo bilge strainer and piping to coupling. Located just fwd of Engine room.
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 22 May 2017
Resolution: Verified at Annual Inspection. All sat.
Engineering › Bilge Water Management System › Valve
Issued 22 March 2016
Resolved
Make repairs to bilge valve for crew quarters space. Vlv located under hydraulic tank in E/R.
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 22 May 2017
Resolution: Verified at Annual Inspection. All sat.
Communications › Radio Communications › EPIRB
Issued 21 July 2015
Resolved
Replace outdated HRU on EPIRB.
Action required: 705 - Other - as specified
Due 5 August 2015
Resolved 2 February 2017
Lifesaving › Lifebuoys › Serviceable
Issued 21 July 2015
Resolved
Replace/ renew unservicable 30" Ring Life Buoy on starboard side of vessel.
Action required: 705 - Other - as specified
Due 5 August 2015
Resolved 2 February 2017
Lifesaving › Hand Flares › Not on Board
Issued 27 June 2014
Resolved
Provide proof of required flares and keep onboard at all times.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2014
Resolution: Corrected on the spot.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 June 2014
Resolved
Repair port running light. Restricted to daylight opertaion.
Due 23 July 2014
Resolved 23 July 2014
Resolution: Proof of fixed light proven.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 14 August 2008
Resolved
Crew member had not gone through new hire testing. Issued requirement to have crew member get tested and neg results returned before he could act in a safety sensitive position and ensure that a crew member is onboard that was enrolled.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2008
Resolution: Owner provided proof of drug enrollment and results.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 August 2008
Resolved
Vsl only had 46 serviceable Type I PFD onboard. Vsl restricted to 46 total persons until 53 serviceable Type I PFDs are onboard.
Action required: 705 - Other - as specified
Resolved 27 August 2008
Resolution: Visited vsl and saw 7 new life jackets that labelled properly.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 14 August 2008
Resolved
Vsl only had 4 handheld red flares and 7 parachute flares. Vsl required to 6 day and 6 night flares or 12 parachute flares.
Due 14 September 2008
Resolved 27 August 2008
Resolution: Visited vsl and ensured vsl had 6 day and 6 night flares.
Communications › Alarms/Indicators › Fire Alarm
Issued 14 August 2008
Resolved
Vsl did not know how to test fire detection system or if it had been tested. Vsl required to show proof of satisfactory test of fire detection system or self test system.
Due 14 September 2008
Resolved 18 August 2008
Resolution: Spoke with owner who verified that fire detection system was tested when the annual test on fire supression system was completed.
Fire Fighting › Nozzles › Approval
Issued 14 August 2008
Resolved
Vsl had a plastic, straight stream nozzle on fire hose. Vsl required to have approved fire nozzle on fire hose.
Due 14 September 2008
Resolved 27 August 2008
Resolution: Visited vsl and saw metallic veri nozzle on fire hose.
Operations/Management › Drills/Instruction › Not Conducted
Issued 24 May 2005
Resolved
Conduct and log crew training IAW 46 CFR 185.420.
Due 30 June 2005
Resolved 30 May 2005
Operations/Management › Equipment Service/Testing › EPIRB
Issued 24 May 2005
Resolved
Log monthly EPIRB tests.
Due 30 June 2005
Resolved 30 June 2005
Fire Fighting › Firemans Outfit › Axe
Issued 6 May 2003
Resolved
Stencil vessel name on fire axe.
Due 15 May 2003
Resolved 8 May 2003
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 6 May 2003
Resolved
Replace 60' of line on ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2003
Resolved 8 May 2003
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 May 2003
Resolved
Install halyard clip on lanyard from ring buoy to waterlight.
Due 15 May 2003
Resolved 8 May 2003
Engineering › Bilge Water Management System › Manifold
Issued 6 May 2003
Resolved
Label bilge system in engine room to show which compartment each valve serves.
Due 15 May 2003
Resolved 8 May 2003
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 26 April 2001
Resolved
Test emergency fire pump by 27May01.
Condition: Unknown
Due 27 May 2001
Resolved 27 May 2001
Construction/Loadline
Issued 12 May 2000
Resolved
PROVE PROPER OPERATION OF VESSEL BILGE ALARMS.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Accommodation/Occupational Safety
Issued 12 May 2000
Resolved
LABEL FORWARD EMERGENCY ESCAPE.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Electrical
Issued 12 May 2000
Resolved
PROVIDE EXHAUST LAGGING ON FLEXIBLE SECTION OF PORT SSG GENERATOR EXHAUST.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Electrical
Issued 12 May 2000
Resolved
PROVIDE NEW ELECTRICAL JUNCTION BOX COVERS IN WAY OF DAMAGED COVERS IN FWD HOLD SPACE.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Lifesaving
Issued 27 April 1998
Resolved
INSTALL BIGHTS ON LIFELINE NOT LONGER THAN 3 FEET EACH OF AT LEAST 3/8 AND BUOYANT ON 15 PERSON LIFEFLOAT.
Condition: Unknown
Due 28 April 1998
Resolved 30 April 1998
Lifesaving
Issued 27 April 1998
Resolved
PROVIDE WIRE SPLINT IN FIRST AID KIT.
Condition: Unknown
Due 28 April 1998
Resolved 30 April 1998
Lifesaving
Issued 27 April 1998
Resolved
PROVIDE MORE SURVIVAL EQUIPMENT TO ENSURE 50% ONBOARD.
Condition: Unknown
Due 27 April 1998
Resolved 30 April 1998
Fire Fighting
Issued 27 April 1998
Resolved
PROVIDE 1 AI, 1 BI AND 2 BII PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 27 April 1998
Resolved 30 April 1998
Documentation
Issued 27 April 1998
Resolved
PROVIDE PROOF OF CURRENT ENROLLMENT FOR CREW IN RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Construction/Loadline
Issued 27 April 1998
Resolved
PROVIDE GAUGING REPORT WITH A MINIMUM OF THREE BELTS.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Documentation
Issued 27 April 1998
Resolved
PROVIDE CURRETN FCC STATION LICENSE.
Condition: Unknown
Due 27 April 1998
Resolved 30 April 1998
Lifesaving
Issued 27 April 1998
Resolved
MARK BOTH LIFEFLOATS WITH CAPACITY IN LETTERS OF AT LEAST 1 1/2 INCHES.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Lifesaving
Issued 27 April 1998
Resolved
REPLACE ROTTEN PADDLES FOR BOTH LIFEFLOATD WITH PADDLES OF AT LEAST 4 FEET.T [name withheld] LIFEFLOAT AND MARK ALL 4 WITH VESSEL NAME.
Condition: Unknown
Due 28 April 1998
Resolved 30 April 1998
Lifesaving
Issued 27 April 1998
Resolved
PROVIDE WATERLIGHT FOR 8 PERSON LIFEFLOAT.
Condition: Unknown
Due 28 April 1998
Resolved 30 April 1998
Lifesaving
Issued 7 April 1997
Resolved
CONDUCT FIRE, ABANDON SHIP AND MAN OVERBOARD DRILLS AND PROVIDE RECORD OF DRILLS.
Condition: Unknown
Due 7 May 1997
Resolved 8 May 1997
Documentation
Issued 7 April 1997
Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 6 May 1997
Resolved 8 May 1997
Lifesaving
Issued 7 April 1997
Resolved
PROVIDE LIFE JACKET DONNING PLACARD.
Condition: Unknown
Due 6 May 1997
Resolved 8 May 1997
Navigation
Issued 7 April 1997
Resolved
PROVIDE UP TO DATE CHARTS OF AREA OF OPERATION.
Condition: Unknown
Due 6 May 1997
Resolved 8 May 1997
Navigation
Issued 7 April 1997
Resolved
PROVIDE CURRENT LIGHT LIST FOR AREA OF OPERATION.
Condition: Unknown
Due 6 May 1997
Resolved 8 May 1997
Navigation
Issued 7 April 1997
Resolved
PROVIDE CURRENT TIDAL CURRENT TABLES FOR AREA OF OPERATION.
Condition: Unknown
Due 6 May 1997
Resolved 8 May 1997
Navigation
Issued 7 April 1997
Resolved
PROVIDE CURRENT TIDE TABLES FOR AREA OF OPERATION.
Condition: Unknown
Due 6 May 1997
Resolved 8 May 1997
Lifesaving
Issued 7 April 1997
Resolved
MARK VESSEL NAME ON EPIRB.
Condition: Unknown
Due 6 May 1997
Resolved 8 May 1997
Lifesaving
Issued 7 April 1997
Resolved
PROVIDE COVERED METAL TRASH CONTAINER IN LOUNGE.
Condition: Unknown
Due 7 May 1997
Resolved 8 May 1997
Lifesaving
Issued 7 April 1997
Resolved
TEST EPIRB MONTHLY AND PROVIDE RECORD.
Condition: Unknown
Due 7 May 1997
Resolved 8 May 1997
Engineering
Issued 7 April 1997
Resolved
INSTALL LAGGING ON MAIN ENGINE EXHAUST PIPING.
Condition: Unknown
Due 6 May 1997
Resolved 8 May 1997
Engineering
Issued 7 April 1997
Resolved
REPAIR EXCESSIVE LEAK NO ENGINE SHAFT.
Condition: Unknown
Due 7 May 1997
Resolved 8 May 1997
Construction/Loadline
Issued 7 April 1997
Resolved
REPLACE GASKETS ON ALL WATERTIGHT DOORS AND HATCHES.
Condition: Unknown
Due 7 May 1997
Resolved 8 May 1997
Documentation
Issued 17 April 1996
Resolved
PROVIDE PROOF OF CURRENT RANDOM DRUG TESTING PROGRAM FOR CREWMEMBERS.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Lifesaving
Issued 17 April 1996
Resolved
REPAIR OR REPLACE OARS FOR LIFE FLOAT.
Condition: Unknown
Due 17 April 1996
Resolved 17 April 1996
Lifesaving
Issued 17 April 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 April 1996
Resolved 19 April 1996
Lifesaving
Issued 17 April 1996
Resolved
PROVIDE NAME OF VESSEL AND LIGHTS ON ALL FOUR IMMERSION SUITS.
Condition: Unknown
Due 17 April 1996
Resolved 19 April 1996
Lifesaving
Issued 17 April 1996
Resolved
PROPERLY MOUNT EPIRB.
Condition: Unknown
Due 17 April 1996
Resolved 19 April 1996
Lifesaving
Issued 17 April 1996
Resolved
UNTIE BUOYANT APPARATUS FROM VESSEL.
Condition: Unknown
Due 17 April 1996
Resolved 19 April 1996
Fire Fighting
Issued 17 April 1996
Resolved
MARK ENGINE ROOM DOORS TO "CLOSE PRIOR TO ACTIVATION OF FIXED CO2 SYSTEM" AND "THIS SPACE PROTECTED BY CO2". THIS DEFICIENCY ALSO NOTED BY FIXED FIREFIGHTING SERVICE COMPANY WHO WAS CONDUCTING INSPECTION.
Condition: Unknown
Due 17 April 1996
Resolved 19 April 1996
Documentation
Issued 19 April 1995
Resolved
PROVIDE EVIDENCE OF DRUG TESTING PROGRAM (PRE-EMPLOYMENT & RANDOM)
Condition: Unknown
Due 30 May 1995
Resolved 11 June 1995
Accommodation/Occupational Safety
Issued 19 April 1995
Resolved
Repair aft port side port light glass.
Condition: Unknown
Due 6 June 1995
Resolved 11 June 1995
Deck/Cargo
Issued 19 April 1995
Resolved
WEIGHT TEST CRANE BOOM.
Condition: Unknown
Due 6 May 1995
Resolved 11 June 1995
Engineering
Issued 19 April 1995
Resolved
INSTALL BONDING STRAP TO STARBOARD FUEL TANK.
Condition: Unknown
Due 6 June 1995
Resolved 11 June 1995
Accommodation/Occupational Safety
Issued 19 April 1995
Resolved
INSTALL RELIEF VALVE TO WATER TANKS (AIR RECEIVER)._x001C_
Condition: Unknown
Due 6 June 1995
Resolved 11 June 1995
Lifesaving
Issued 17 April 1992
Resolved
SERVICE VESSEL LIFERAFT. VESSEL RESTRICTED TO CARRY NOT MORE THAN 46 PASSENGERS WHEN ON COASTWISE ROUTE.
Condition: Unknown
Due 17 April 1992
Resolved 17 April 1992
Lifesaving
Issued 18 May 1991
Resolved
Provide five (5) additional adult life preservers. Total number of personslimited to fifty (50) until this item completed.
Condition: Unknown
Due 18 May 1991
Resolved 18 May 1991
Lifesaving
Issued 18 May 1991
Resolved
Provide weak link for 8 man bouyant apparatus. Total persons limited to 42persons on coastwise route until corrected.
Condition: Unknown
Due 23 August 1991
Resolved 23 August 1991
Fire Fighting
Issued 18 April 1990
Resolved
PROVIDE PORTABLE FIRE/BILGE PUMP WITH SUCTION & DISCHARGE HOSES. (HAND OPERATED)
Condition: Unknown
Due 18 April 1990
Resolved 18 April 1990
Lifesaving
Issued 18 April 1990
Resolved
PROVIDE SEPERAT STOWAGE FOR CHILDS LIFE JACKETS.
Condition: Unknown
Due 18 April 1990
Resolved 18 April 1990
Navigation
Issued 18 April 1990
Resolved
PROVIDE CONTAINER FOR PYROTECHNIC SIGNALS.
Condition: Unknown
Due 18 April 1990
Resolved 18 April 1990
Lifesaving
Issued 18 April 1990
Resolved
PROVIDE A PROPER HYDROSTATIC RELEASE FOR THE INF LIFE RAFT.
Condition: Unknown
Due 18 April 1990
Resolved 18 April 1990
Construction/Loadline
Issued 18 April 1990
Resolved
REPLACE CRACKED PORT HOLE, PORT SIDE FWD.
Condition: Unknown
Due 18 April 1990
Resolved 18 April 1990
Fire Fighting
Issued 18 April 1990
Resolved
PROVIDE MARINE BRACKETS FOR ALL ON BOARD PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 18 April 1990
Resolved 18 April 1990
Electrical
Issued 21 February 1990
Resolved
PROVIDE USCG APPROVED ELECTRICAL DRAWINGS FOR VESSEL'S ELECTRICAL SYSTEM.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Electrical
Issued 22 May 1989
Resolved
PROVIDE LIGHT COVER FOR LIGHT SWITCH IN HEAD.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Electrical
Issued 22 May 1989
Resolved
PROVIDE BULB FOR EMERGENCY LIGHT IN CARGO HOLD ROOM.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Electrical
Issued 22 May 1989
Resolved
PROVIDE EMERGENCY LIGHT IN FORWARD BERTHING AREA.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Electrical
Issued 22 May 1989
Resolved
PROVIDE GUARD TO FLYWHEEL ON GENERATOR.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Electrical
Issued 22 May 1989
Resolved
PROVIDE GLOBE FOR EMERGENCY LIGHT IN ER.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Electrical
Issued 22 May 1989
Resolved
REMOVE PLUG (TEMPORARY) FROM ENGINE ROOM WHICH IS CONNECTED TO REFRIG.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Electrical
Issued 22 May 1989
Resolved
REMOVE WIRING DEAD ENDED FROM FUEL TRANSFER PUMP.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Electrical
Issued 22 May 1989
Resolved
REMOVE ALL DEAD END WIRE IN FORWARD HEAD.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Unknown
Issued 22 May 1989
Resolved
PROVIDE COPY OF FIRE SERVICING CERTIFICATE AND GIVENS LIFERAFT CERT. TO OCMI.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Construction/Loadline
Issued 22 May 1989
Resolved
PROVIDE COVER TO FORWARD BERTHING VENT.
Condition: Unknown
Due 22 May 1989
Resolved 22 May 1989
Fire Fighting
Issued 30 April 1987
Resolved
PRIOR TO 30 MAY 1987, PROVIDE USCG MSD KENAI WITH A COPY OF THE FIRE EXT- INGUISHING EQUIPMENT SERVICING CERTIFICATE ISSUED BY THE COMPANY WHICH CONDUCTED THE TESTS.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Lifesaving
Issued 6 June 1986
Resolved
PROVIDE 6 CURRENT DATED RED HAND HELD FLARES PRIOR TO 6 JULY 1986.
Condition: Unknown
Due 6 June 1986
Resolved 6 June 1986
Electrical
Issued 6 June 1986
Resolved
PROVIDE GLOGE AND GUARD FOR LIGHTING FIXTURE IN FORWARD BERTHING PRIOR TO 6 JULY 1986.
Condition: Unknown
Due 6 June 1986
Resolved 6 June 1986
Fire Fighting
Issued 6 June 1986
Resolved
PROVIDE MSD KENAI WITH A COPY OF FIRE EXTINGUISHER SERVICING REPORT PRIOR TO 6 JULY 1986.
Condition: Unknown
Due 6 June 1986
Resolved 6 June 1986
Electrical
Issued 6 June 1986
Resolved
PROVIDE PROTECTIVE COVER OVER FLY WHEEL ON SERVICE GENERATOR PRIOR TO 6 JULY 1986.
Condition: Unknown
Due 6 June 1986
Resolved 6 June 1986
Electrical
Issued 6 June 1986
Resolved
PROVIDE COVER OVER GENERATOR DRIVE BELTS PRIOR TO 6 JULY 1986.
Condition: Unknown
Due 6 June 1986
Resolved 6 June 1986
Unknown
Issued 13 January 1986
Resolved
PRIOR TO 31 JANUARY 1986 STENCIL THE FWD. ESCAPE HATCH WITH "EMERGENCY ESCAPE HATCH".
Condition: Unknown
Due 13 January 1986
Resolved 13 January 1986
Deck/Cargo
Issued 13 January 1986
Resolved
PRIOR TO CARRYING PASSENGERS AND NO LATER THAN 21 JANUARY 1986 REMOVE FROM THE VESSEL THE FUEL OIL TRANSFER HOSE LOCATED ON THE BOW, PORT SIDE.
Condition: Unknown
Due 13 January 1986
Resolved 13 January 1986
Electrical
Issued 13 January 1986
Resolved
PRIOR TO 31 JANUARY 1986 REMOVE ALL ROMEX TYPE SOLID CORE HOUSE HOLD WIRE IN THE MAIN HOLD AND REPLACE WITH MARINE APPROVED TYPE WIRE AND OUTLETS.
Condition: Unknown
Due 13 January 1986
Resolved 13 January 1986
Construction/Loadline
Issued 13 January 1986
Resolved
PRIOR TO 31 JANUARY 1986 PROVIDE A GLASS SIGHT GLASS AND METAL GUARDS TO THE VESSELS FUEL OIL DAY TANK.
Condition: Unknown
Due 13 January 1986
Resolved 13 January 1986
Lifesaving
Issued 8 April 1985
Resolved
HAVE THE SIX(6) MAN GIVENS INFALATABLE LIFE RAFT SERVICED & INSPECTED AT CGCERTIFIED SERVICING FACILITY PRIOR TO 8 MAY 85 OR REMOVE FROM THE VESSEL
Condition: Unknown
Due 8 April 1985
Resolved 8 April 1985
Lifesaving
Issued 8 April 1985
Resolved
PROVIDE RETROREFLECTIVE TAPE ON THREE(3) CHILD'S PFD'S PRIOR TO 16 APRIL 85
Condition: Unknown
Due 8 April 1985
Resolved 8 April 1985