Records from 2013 to 2026. Most recent: inspection, 17 June 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 April 2026
No resolution recorded
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a dry dock inspection and an internal structural at least once every two years.
Vessel's drydock inspection and ISE were overdue as of March 31, 2026.
Vessel is no sailed until such time as a satisfactory drydock inspection is complete.
Action required: 17 - Rectify deficiencies prior to departure
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 May 2025
Resolved
Vessel had a through hull in the starboard, aft bunkroom that was not properly sealed. Showed vessel rep and he will correct the issue and notify local OCMI when repairs are complete.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2025
Resolution: Received photo of side shell opening sealed. All SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 May 2025
Resolved
(g) Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows:
(1) Spaces storing carbon dioxide—
‘‘CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.’’.
(2) Spaces protected by carbon dioxide—‘‘
CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.’’
(3) Spaces into which carbon dioxide might migrate—
‘‘CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. DISCHARGE INTO NEARBY SPACE CAN COLLECT HERE. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED VACATE IMMEDIATELY.’’
MI found no signage on CO2 protected spaces. Provide proper verbiage and signage to all CO2 spaces as required. Notify local OCMI once corrected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 24 June 2025
Resolution: Received photo of CO2 signage. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 July 2024
Resolved
Vessel's 50 person inflatable buoyant apparatus (IBA) is due for servicing. Remove IBA from vessel until it has been serviced. Total person count is reduced for oceans route to no more than 50 persons. Total person count is reduced for limited coastwise route to no more than 74 persons.
Action required: 705 - Other - as specified
Resolved 30 May 2025
Resolution: MI attended vessel. 03 life rafts onboard with 100 people capacity. All SAT.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 July 2024
Resolved
Starboard most remote fuel shutoff handle is inopperable. Repair the affected handle and demonstrate a satisfactory test of the shut off in the presence of a USCG marine inspector. To be rectified prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2024
Resolution: New handle was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2024
Resolved
Vessel only had 82 adult lifejackets available for inspection. Make remain lifejackets available for inspection. Total person count of vessel is reduced to 82 persons until this deficiency is rectified.
Action required: 705 - Other - as specified
Resolved 30 May 2025
Resolution: MI attended vessel. All SAT.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 24 July 2024
Resolved
Vessel does not have a general alarm or PA speakers in the lower berthing areas. Add PA system speakers in the lower berthing areas. To be rectified by 23 August 2024.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 October 2024
Resolution: New speakers installed.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 28 March 2024
Resolved
A vessel with installed toilet facilities must have a marine sanitation device that complies with 33 CFR part 159. Starboard toilet holding tank was leaking water from the piping connections at the tank into the bilge. Vessel is to secure water connection and is restricted from toilet use until defective piping and tank is examined and repaired to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2024
Resolved 24 July 2024
Resolution: Leak was repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 July 2023
Resolved
An inflatable life raft or inflatable buoyant apparatus must be serviced at a facility specifically no later than the month and year on its servicing sticker affixed under 46 CFR 160.151-57(n). Service dates on both inflatable life rafts were expired. Vessel is redistricted to no more than 74 passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2023
Resolution: Proof has been provided Life raft serviced at facility. Viking Service 07/31/2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 July 2023
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than a small buoyancy compartments. Bilge pump in lazarette was in-operable. 46CFR182.25-1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2023
Resolution: Bilge pump serviced and witnessed satisfactory test.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 July 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire. 02 wires in the aft void were not connected to anything and just had electrical tape on the end of them and could injury crew in the space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 July 2023
Resolution: Wires capped and ensured no power.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 January 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2023
Resolution: SYSTEMS INSTALLED AND TESTED
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 July 2022
Resolved
Main Engine serpentine belt rotating covers were not properly protected by cover, guard or rail. Must provide guard/cover over belt area to the satisfaction of the USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2022
Resolved 4 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 July 2022
Resolved
Each vessel that relies on electricity to power the loads to vessel vital systems must be arranged so that the loads can be energized from two sources of electricity. Vessel generators unable to take raw water cooling due to an inoperable pump and valve closure device. Must rectify to satisfaction of USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2022
Resolution: Rectified to satisfaction of attending MI: [name withheld]
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 20 July 2022
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. Flamescreen on starboard fuel vent is completely wasted. Must repair to satisfaction of USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2022
Resolved 4 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 July 2022
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Ring buoy on upper port side of vessel must be replaced and destroyed. Ring buoy on lower deck level must have vessel name stenciled on it.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2022
Resolved 22 July 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 April 2022
Resolved
Vessel is overdue for dry dock exam and internal structural exam. Complete a credit dry dock exam and internal structural exam prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2022
Resolution: Vessel completed satisfactory dry dock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 July 2021
Resolved
VSL’s main f/o service tank sightglass has been removed and piping was found open to atmosphere IVO the center cutout valves. Cap piping to ensure f/o does not enter engine space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 14 October 2021
Resolution: Capped
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 July 2021
Resolved
A wooden face plate was found on a electrical switch enclosure in the engine space. Replace with an metal type enclosure suitable for marine environments.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2021
Resolved 14 October 2021
Resolution: replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 July 2021
Resolved
Vessel was missing 20 adult lifejackets. Replace the missing adult lifejackets with ones approved by 46 CFR 160.002, 160.005, or 160.055. Total adult person count of the vessel is reduced to 20 until this deficiency is corrected.
Action required: 705 - Other - as specified
Resolved 14 October 2021
Resolution: [name withheld] received an email with pictures of the new life jackets.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 16 April 2020
Resolved
FUEL TANK SIGHTGLASS WAS FOUND UNSECURED AND COULD ALLOW FUEL TO SPILL INTO MACHINERY SPACE. REPLACE WITH SIGHTGLASS THAT IS ADEQUATELY PROTECTED FROM MECHANICAL DAMAGE WITH DEVICES THAT AUTOMATICALLY CLOSE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2020
Resolved 13 July 2020
Resolution: Master will keep valve closed until soundings are required.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 April 2020
Resolved
A BROKEN MACHINERY SPACE LIGHT WAS FOUND WHICH COULD IGNITE FLAMMABLE VAPORS. REPLACE OR REPAIR.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 April 2020
Resolved 13 July 2020
Resolution: Replaced broken lens
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 April 2020
Resolved
REPLACE LIFE JACKET LIGHTS FOUND INOPERABLE DURING INSPECTION.
Due 24 April 2020
Resolved 24 April 2020
Resolution: replaced while onboard
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 18 March 2020
Resolved
Repair broken port engine room hatch and treat rot.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2020
Resolution: hatch repaired
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 18 March 2020
Resolved
Remove rot and treat wood around engine room man hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2020
Resolution: rot repaired
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 18 March 2020
Resolved
Remove rot and seal transverse frame aft of tool box in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2020
Resolution: removed rot
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 18 March 2020
Resolved
Seal unused fuel fill fitting on main deck leading to engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2020
Resolution: fitting sealed
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 March 2020
Resolved
Remove rot and seal wood around bolt protruding from forward starboard section of hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2020
Resolution: rot removed
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 March 2020
Resolved
After refloating, make vessel available and conduct in water check ride with attending USCG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2020
Resolution: COI Inspection conducted
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 March 2020
Resolved
Mark upper deck with maximum allowed passengers (119).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2020
Resolution: Marked as required
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 18 March 2020
Resolved
Repair or replace (06) wasted upper deck rail stanchions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2020
Resolution: repaired
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 October 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2020
Resolved 19 November 2020
Resolution: Corrected
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 9 October 2019
Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously. Vessel has been instructed to operate with a look-out and watchman while conducting drift operations.
Action required: 10 - Deficiency Rectified
Due 9 October 2019
Resolved 9 October 2019
Resolution: Educated captain and crew
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 9 October 2019
Resolved
Provide accommodation compartment with additional 04 emergency exits lights at all exits.
Action required: 705 - Other - as specified
Due 9 January 2020
Resolved 24 April 2020
Resolution: exits marked
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 October 2019
Resolved
Provide all electrical panels with blank cover for missing breakers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2019
Resolved 19 August 2020
Resolution: blanks installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 October 2019
Resolved
Remove all solid copper cabling (Romex) from forward electrical sub panel and renew with proper sized stranded boat cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2019
Resolved 27 April 2020
Resolution: romex removed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 October 2019
Resolved
Remove or enclose dead ended cable fed from forward electrical sub panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2019
Resolved 19 August 2020
Resolution: removed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 October 2019
Resolved
Removed permanently installed extension cord from forward electrical outlet.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 November 2019
Resolved 19 August 2020
Resolution: Removed
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018
Resolved
CLSN: Vsl is broadcasting Invalid Call Sign, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 20 March 2020
Resolution: Cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 July 2018
Resolved
Renew two life rings on upper deck
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2018
Resolved 21 September 2018
Resolution: 02 Life rings renewed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 July 2018
Resolved
Provide complete but simple instructions for for the operation of a fixed gas fire extinguishing system at each pull box and in the space where the cylinders are stored.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2018
Resolved 21 September 2018
Resolution: Simple instruction were posted
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 23 July 2018
Resolved
Properly service and prove operation on the forward watertight hatch.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2018
Resolved 21 September 2018
Resolution: Proved proper operation on forward watertight hatch
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 23 July 2018
Resolved
Label all emergency hatches on both sides(at least 1" high "EMERGENCY EXIT, KEEP CLEAR"
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2018
Resolved 21 September 2018
Resolution: Emergency hatches were properly labeled
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 23 July 2018
Resolved
Properly secure port and starboard main engine raw water strainers
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2018
Resolved 21 September 2018
Resolution: Strainers are properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 23 July 2018
Resolved
Renew flexible hose for starboard main engine raw water inlet.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2018
Resolved 21 September 2018
Resolution: Flexible hose was renewed.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 23 July 2018
Resolved
Remove fire hazard on grill hood exhaust. Install leak proof ducting and properly drain
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2018
Resolved 21 September 2018
Resolution: Installed newed grill hood and installed grease drain.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 23 July 2018
Resolved
Repair portside main engine jack water cooling exchanger
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2018
Resolved 21 September 2018
Resolution: Jacket water cooler was properly repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2018
Resolved
Remove unauthorized electric chord on water maker and install marine type and properly sized cable.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2018
Resolved 21 September 2018
Resolution: Unauthorized wired was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 23 July 2018
Resolved
Properly secure water maker pump
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2018
Resolved 21 September 2018
Resolution: The water pump was properly secured.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 July 2018
Resolved
Renew portside fire hose and prove proper operation. (cleared on the 07/24/2018 CJB
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2018
Resolution: Renewed hose and prove proper operation.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 July 2017
Resolved
Provide UL1104 Anchor Light
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 12 July 2017
Resolution: Defciciency rectified to the satisfaction of the MI
Navigation › Piloting/Steering › Marine Charts
Issued 6 July 2017
Resolved
Provide current and correct charts for area of operation
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 12 July 2017
Resolution: Defciciency rectified to the satisfaction of the MI