MAURY USCG vessel records Sign in
← All vessels

UKPIK

UKPIK is a 1973 research vessel. The Coast Guard has recorded 58 inspections since 1985, most recently in March 2026, along with 49 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 17 March 2026.

Built
1973
Last inspected
17 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBI8340
Flag
UNITED STATES
367184280, 367486920 (licence lapsed)
Maury page id
psix-47541

Inspections, by type

…with no type recorded6
Years with a record 31 calendar years (1985–2026)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)48.5 ft × 15.2 ft × 6.3 ft
Registered tonnagegross 38 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUS. INC. · SEATTLE, WA, UNITED STATES · built 1973
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPRUDHOE BAY, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 March 2026 · expires 31 March 2027
Service, as the file records itResearch Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Regulatory (Subpart C or D), Gross Ton
25 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF7672MMSI 367486920 · expired · compulsorily equipped · granted 20 April 2011, cancelled 26 June 2021
WBI8340MMSI 367184280 · expired · compulsorily equipped · granted 1 May 2007, cancelled 23 September 2017 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 58

17 March 2026 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8329498
24 June 2022 ORV Letter of Designation · Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7486027
4 March 2020 Administrative Inspection · ORV Letter of Designation
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6939695
11 January 2018 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6368231
10 March 2016 ORV Letter of Designation · Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5831509
15 October 2010 Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3869811
6 October 2010 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3870742
22 September 2010 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3855883
18 March 2009 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3440632
16 January 2009 Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3394745
5 March 2008 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3160222
2 October 2007 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3086822
28 March 2007 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2890628
22 March 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2892624
9 February 2007 Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2869691
29 March 2006 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2618686
9 March 2005 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2276492
25 March 2004 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2012292
26 March 2003 Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1758926
12 March 2003 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1755714
14 February 2003 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1743792
18 March 2002 Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1492181
18 March 2002 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1606220
22 February 2002 Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1488982
23 February 2001 Hull Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1386980
14 February 2000 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 815930
18 March 1999 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1400952
26 February 1998 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1390725
28 February 1997 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1105248
13 February 1997 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1398612
7 November 1996 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1380690
7 March 1996 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1412985
28 March 1995 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 830580
8 March 1995 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1403916
14 November 1994 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1173336
24 February 1994 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1394067
18 March 1993 Re-Inspection · Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1385038
5 October 1992 Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1245645
17 April 1992 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1267749
10 April 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1260707
29 May 1991 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1228876
2 May 1991 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1224852
20 March 1990 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1221274
27 February 1990 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1213112
25 September 1989 Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 898577
18 September 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 889181
21 August 1989 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1193779
21 July 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1343849
11 May 1989 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1207841
26 August 1988 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1038768
3 August 1988 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1342161
12 May 1988 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1200920
14 March 1988 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1031337
5 November 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1021008
22 May 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1004924
10 June 1986 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1302258
6 June 1986 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1293026
15 May 1985 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1293482

Deficiency record · 49

Navigation › Piloting/Steering › Coast Guard Light List
Issued 22 September 2010 Resolved
Provide current USCG light list prior to carrige of passengers in accordance with 46 CFR 184.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 October 2010
Resolution: Current USCG Light List now onboard vessel.
Accommodation/Occupational Safety › Ventilation › General
Issued 22 September 2010 Resolved
Make all wire runs and piping holes thru engine room bulkhead vapor tight in accordance with 46CFR 177.405
Action required: 705 - Other - as specified
Due 6 October 2010
Resolved 6 October 2010
Resolution: All throughputs in foward engine room bulkhead are now vaportight.
Construction/Loadline › Structures › Deck Plating
Issued 22 September 2010 Resolved
Provide plans for strengthening decking above starboard engine.
Action required: 705 - Other - as specified
Due 6 October 2010
Resolved 6 October 2010
Resolution: O/O fabricated a support using multiple 2x4''s and it is in place under the decking in question. O/O will effect permanent repairs the decking at next drydock.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 28 March 2007 Resolved
Detection system wiring is not monitored for wire condition.
Action required: 705 - Other - as specified
Due 28 March 2008
Resolved 2 October 2007
Resolution: 02OCT07: Cleared requirement for installation of an electrically supervised fire detection system, installed system meets MOC Policy LTR 4-98.
Engineering › Bilge Water Management System
Issued 26 March 2003 Resolved
Repair and prove operation of bilge high level alarms in generator and engine rooms. This item to be completed prior to carriage of passengers, but not later than 26APR03.
Due 26 April 2003
Resolved 28 March 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 14 February 2003 Resolved
Make repairs to 7 areas on the hand rails. 5 on the starboard and 2 on the port. These areas need to be tighten or welded. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Due 14 April 2003
Resolved 26 March 2003
Accommodation/Occupational Safety › Potable Water System
Issued 14 February 2003 Resolved
Provide double clamp for the fresh water tank vents overboard fitting. LEGACY COMPONENT DESC: Vent Hose Clamp
Condition: Unknown
Due 14 March 2003
Resolved 12 March 2003
Engineering › Bilge Water Management System
Issued 14 February 2003 Resolved
Label the bilge manifold to show what compartments they serve. LEGACY COMPONENT DESC: Manifold
Condition: Unknown
Due 14 March 2003
Resolved 12 March 2003
Construction/Loadline › Penetrations
Issued 14 February 2003 Resolved
Tighten through hole fitting for the main engine bilge pump discharge over the side. LEGACY COMPONENT DESC: Through Hole Fittings
Condition: Improper/Lack of Maintenance
Due 14 March 2003
Resolved 12 March 2003
Construction/Loadline › Penetrations
Issued 14 February 2003 Resolved
Seal holes between the engine room bulkhead and the accommodations space, make fume tight. LEGACY COMPONENT DESC: Bulkhead
Condition: Unknown
Due 14 March 2003
Resolved 12 March 2003
Construction/Loadline › Penetrations
Issued 14 February 2003 Resolved
Fix pipe for the fish hold drain and provide clamps for the overboard through hole fittings. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 14 March 2003
Resolved 12 March 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 14 February 2003 Resolved
Provide double clamps on the starboard exhaust overboard fitting. LEGACY COMPONENT DESC: Exhaust hose
Condition: Improper/Lack of Maintenance
Due 14 March 2003
Resolved 12 March 2003
Construction/Loadline › Structures
Issued 28 March 2002 Resolved
Prove engine room hatches are watertight as per 46CFR171.124. These hatches must have latching mechanism and captive chain attached. LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Improper Installation
Due 28 April 2002
Resolved 9 April 2002
Resolution: O/O fitted port and starboard engine hatches with rubber gaskets and hatch securing devices. Keeper chain also installed. Both modifcation were satisfactory.
Lifesaving › Inflatable Liferafts
Issued 18 March 2002 Resolved
Provide documentation for the installed IBA indicating: mfg. number, serial number, lot number, and mfg. date (Zodiac) LEGACY COMPONENT DESC: Container Marking
Condition: Improper Installation
Due 18 April 2002
Resolved 28 March 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 18 March 2002 Resolved
Provide 2 each 1-ounce bottles of eye wash solution for the first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Due 18 April 2002
Resolved 28 March 2002
Lifesaving › Lifebuoys
Issued 18 March 2002 Resolved
Restencil vessel's name on ring buoy. LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Improper Installation
Due 18 April 2002
Resolved 28 March 2002
Pollution Prevention/Response › Prevention Equipment
Issued 18 March 2002 Resolved
Renew lower rubber sleeve on MSD tank overboard discharge. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Unknown
Due 18 April 2002
Resolved 28 March 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 18 March 2002 Resolved
Have all portable fire extinguishers professionally service and checked for 6yr/12yr maintenance/hydrotests. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2002
Resolved 28 March 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 18 March 2002 Resolved
Have the fixed CO2 system annually serviced, by professional service facility. LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2002
Resolved 28 March 2002
Documentation › Logs/Records
Issued 18 March 2002 Resolved
Provide record/log book to record inspections and testing of: EPIRB, life saving equipment (and fire equipment optional). Also to record fire and man overboard drills. LEGACY COMPONENT DESC: Logbook/Record (unofficial)
Condition: Unknown
Due 18 April 2002
Resolved 28 March 2002
Unknown
Issued 23 February 2001 Resolved
Operationally test radio, navigation, bilge, and steering systems to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 23 March 2001
Resolved 12 March 2001
Navigation
Issued 18 March 1999 Resolved
PROPERLY WELD CRACK IN RUDDER (PORTSIDE).
Condition: Unknown
Due 30 March 1999
Resolved 30 March 1999
Lifesaving
Issued 26 February 1998 Resolved
PERFORM REQUIRED DRILLS IN PRESENCE OF CG MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Unknown
Issued 13 February 1997 Resolved
PROVIDE A COAST GUARD APPROVED FIRST AID KIT OR EQUIVALENT.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Lifesaving
Issued 13 February 1997 Resolved
INSTALL RETROREFLECTIVE TAPE ON THE LIFE FLOATS AND LIFE RINGS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Electrical
Issued 13 February 1997 Resolved
INSTALL LOAD TO ELECTRICAL WIRES IN LAZARETTE OR REMOVE WIRE IN ITS ENTIRETY.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Construction/Loadline
Issued 13 February 1997 Resolved
PROVIDE WATERTIGHT CLOSURE FOR THE STBD THROUGH HULL FITTING IN THE TRANSOMFROM THE LAZARETTE.
Condition: Unknown
Due 18 February 1997
Resolved 18 February 1997
Electrical
Issued 13 February 1997 Resolved
REMOVE WIRE NUTS AND INSTALL TERMINAL BLOCKS OR OTHER ACCEPTED MEANS FOR THE BILGE SYSTEM, AND AS ELSEWHERE LOCATED ON THE VESSEL.
Condition: Unknown
Due 13 February 1997
Resolved 13 February 1997
Unknown
Issued 7 March 1996 Resolved
Properly display MARPOL I placard.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Unknown
Issued 7 March 1996 Resolved
Provided evidence of the date of purchase of the hydrostatic release devicefor the EPIRB, so the expiration date can be confirmed.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Unknown
Issued 7 March 1996 Resolved
Provide current documentation of membership in random drug testing program.
Condition: Unknown
Due 24 May 1996
Resolved 24 May 1996
Construction/Loadline
Issued 8 March 1995 Resolved
Prove proper operation of bilge pump. Complete affidavit and return to OCMI.
Condition: Unknown
Due 8 March 1995
Resolved 8 March 1995
Electrical
Issued 8 March 1995 Resolved
Prove proper operation of electronic equipment. Complete affidavit, and return to OCMI.
Condition: Unknown
Due 8 March 1995
Resolved 8 March 1995
Engineering
Issued 8 March 1995 Resolved
Prove proper operation of main engines. Complete affidavit and return to OCMI.
Condition: Unknown
Due 8 March 1995
Resolved 8 March 1995
Engineering
Issued 18 March 1993 Resolved
TEST MAIN ENGINE OF BILGE SYSTEM.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Construction/Loadline
Issued 18 March 1993 Resolved
PROVIDE ADEQUATE HOSE FOR HAND BILGE PUMP.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Navigation
Issued 18 March 1993 Resolved
PROVODE UPDATED CURRENT TABLE AND LIGHT LIST.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Navigation
Issued 18 March 1993 Resolved
TEST SSB.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Navigation
Issued 18 March 1993 Resolved
DOUBLE NUT STEERING BEAR TIE ROD.
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993
Electrical
Issued 17 April 1992 Resolved
INSTALL AMMETER IN BATTERY CHARGER CIRCUIT.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Lifesaving
Issued 17 April 1992 Resolved
INSTALL MOUNTING BRACKETS FOR BOTH LIFERINGS.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Electrical
Issued 17 April 1992 Resolved
DC POWER PANEL: LABEL CIRCUITS AND PROVIDE INFORMATION DRAWING FOR ELECTRICAL WIRING REVISION.
Condition: Unknown
Due 11 May 1992
Resolved 11 May 1992
Construction/Loadline
Issued 27 February 1990 Resolved
REFASTEN STARBOARD DECK BEAM IN ENGINE ROOM.
Condition: Unknown
Due 27 February 1990
Resolved 27 February 1990
Accommodation/Occupational Safety
Issued 27 February 1990 Resolved
REPAIR OR REPLACE TWO WASHDOWN VALVES IN LAZARETTE.
Condition: Unknown
Due 27 February 1990
Resolved 27 February 1990
Construction/Loadline
Issued 27 February 1990 Resolved
REPAIR OR REPLACE ENGINEROOM HATCH COVERS. PROVE WATERTIGHTNESS OF HATCHES IN PRESENCE OF COAST GUARD INSPECTOR.
Condition: Unknown
Due 27 February 1990
Resolved 27 February 1990
Construction/Loadline
Issued 27 February 1990 Resolved
PROPERLY LABEL BILGE MANIFOLD VALVES.
Condition: Unknown
Due 27 February 1990
Resolved 27 February 1990
Navigation
Issued 12 May 1988 Resolved
DEMONSTRATE OPERATION OF MASTHEAD LIGHT.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Accommodation/Occupational Safety
Issued 12 May 1988 Resolved
IN LIEU OF OPENING HOT WATER TANK FOR INTERNAL INSPECTION OR CONDUCTING A HYDROSTATIC TEST, PROVIDE A 100 PSI OR LOWER PRESSURE RELIEF VALVE.
Condition: Unknown
Due 12 May 1988
Resolved 12 May 1988
Construction/Loadline
Issued 5 November 1987 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, VESSEL IS TO BE DRYDOCKED.
Condition: Unknown
Due 5 November 1987
Resolved 5 November 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.