MAURY USCG vessel records Sign in
← All vessels

SEDCO K *

SEDCO K * is a 1973 mobile offshore drilling unit. The Coast Guard has recorded 4 inspections since 1984, most recently in December 1987, along with 12 deficiencies.

Records from 1984 to 1987. Most recent: inspection, 1 December 1987.

Built
1973
Last inspected
1 December 1987
Documentation
Invalid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-47542

Inspections, by type

…with no type recorded1
Years with a record 3 calendar years (1984–1987)
The 4 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 39 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)322.6 ft × 360.1 ft × 29.0 ft
Registered tonnagegross 3,733 / net 3,180
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · ORANGE, TX, UNITED STATES · built 1973
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNot recorded
Trade endorsementsRegistry
DocumentationInvalid
Service, as the file records itMobile Offshore Drilling Unit
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3733 - Regulatory (Subpart C or D), Gross Ton
3180 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 4

1 December 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1027418
7 May 1986 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1014236
17 January 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1294699
18 December 1984 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1284065

Deficiency record · 12

Fire Fighting
Issued 17 January 1986 Resolved
REPLACE 2-50 X 2 1/2" AND 1-100 X 2 1/2" FIRE HOSES AND PROVIDE 4-2 1/2 ALL PURPOSE FIRE FIGHTING NOZZLES.
Condition: Unknown
Due 6 March 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 17 January 1986 Resolved
PROVIDE FIREFIGHTING FOAM SAMPLE ANALYSIS REPORT THAT MEETS THE REQUIRMENTSOF 46 CFR 107.235(B)(2)(III).
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 17 January 1986 Resolved
SERVICE ALL INFLATABLE LIFERAFTS AT A U.S. COAST GUARD APPROVED FACILITY.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 17 January 1986 Resolved
REPLACE ALL FIREFIGHTING ALL PURPOSE NOZZLES THAT DO NOT MEET THE MATERIAL REQUIREMENTS (METAL INTERNALS) OF 46 CFR 162.027. (TEFLON VALVE BODIES ARENOT ACCEPTABLE).
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 17 January 1986 Resolved
PROVIDE ORIGINAL WALL THICKNESS READINGS FOR VESSELS MOTION COMPENSATORS AND GUIDE LINE TENTIONERS (APV BOTTLES) FOR COMPARSION WITH GAUGING REPORT OF OCTOBER 1985.
Condition: Unknown
Due 30 June 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 18 December 1984 Resolved
PROVIDE AND INSTALL PROPER CLOSURES FOR THE LOUVERS, DECK DRAINS, VENTILATION DUCTS, SUPPLY AND EXHAUST FANS, AND ELECTRIC CABLE PENETRATIONSIN THOSE SPACES PROTECTED BY THE FIXED CO2 SYSTEM.
Condition: Unknown
Due 18 December 1984
Resolved 18 December 1984
Electrical
Issued 18 December 1984 Resolved
PROPERLY SEAL ALL PIPE AND ELECTRICAL CABLE PENETRATIONS IN THE BOUNDRY BHD OF THE MUD PIT ROOM AND INSTALL "EYS" FITTINGS ON ELECTRICAL CABLE ENTRANCES TO EXPLOSION-PROOF EQUIPMENT.
Condition: Unknown
Due 1 June 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 18 December 1984 Resolved
PROVIDE TWO OXYGEN AND EXPLOSIVE METERS FOR FIREMAN OUTFITS OR REPAIR THOSETHAT ARE ON BOARD.
Condition: Unknown
Due 18 December 1984
Resolved 18 December 1984
Electrical
Issued 18 December 1984 Resolved
REPAIR OR DEMONSTRATE THE OVERSPEED TRIP ON THE EMERGENCY DIESEL GENERATOR.
Condition: Unknown
Due 18 December 1984
Resolved 18 December 1984
Lifesaving
Issued 18 December 1984 Resolved
PROVIDE AND INSTALL ONE ADDITIONAL LIFERAFT DAVIT. THE UNIT PRESENTLY HAS FOUR RECENTLY INSTALLED DAVIT-LAUNCHED LIFERAFTS.
Condition: Unknown
Due 18 December 1984
Resolved 18 December 1984
Fire Fighting
Issued 18 December 1984 Resolved
INSULATE WITH A-60 METERIAL THE AREA BEHIND ALL CO2 CYLINDERS IN THE CO2 ROOM THAT ARE ADJACENT TO THE SPACES THEY PROTECT (ENGINEROOM AND BOILER ROOM)
Condition: Unknown
Due 18 December 1984
Resolved 18 December 1984
Electrical
Issued 18 December 1984 Resolved
CORRECT THE FOLLOWING ON THE DRILL FLOOR: A) THE 2 LOWER ELECTRIC CABLE ENTRANCES INTO THE GEN ALARM PANEL REQUIRE "EYS" FITTINGS B) THE 2 ELECTRICCABLE ENTRANCES INTO THE GEN ALARM BELL REQUIRE "EYS" FITTINGS C) PROPERLY PURGE IAW NFPA $496 THE DRAW WORKS & DRILLERS CONSOLES.
Condition: Unknown
Due 18 December 1984
Resolved 18 December 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.